OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4

Similar documents
High Pressure E/P Regulator. ITVH Series

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts.

Varispeed SERIES OPTION CARD DeviceNet COMMUNICATION INTERFACE CARD USER'S MANUAL Model: SI-N1

Doc. No.: EX**-OMC0024. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1 SMC CORPORATION

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

SI unit for IO-Link device

SI unit for EtherNet/IP TM EX250-SEN1

SI unit for IO-Link device

Fieldbus system Analog unit

Fieldbus system EtherCAT compatible SI unit

Ethernet ITV Modbus TCP

Digital Gap Checker. ON: Placed. Workpiece. Large gap. Workpiece. Workpiece. Small gap. Detection surface Detection nozzle. Air

EtherNet/IP TM SI unit

Operating instructions. Switching amplifier DN0210 DN / / 2015

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

No.EX##-OMN0030-A. Fieldbus system DeviceNet TM compatible SI unit PRODUCT NAME. EX600-SDN#A EX600-ED# MODEL/ Series

Flow Monitor PF2A20# PF2W20# PF2D20#

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Operating instructions. Speed monitor D / / 2014

Digital Pressure Switch

RS-FS-N01 Wind speed transmitter user's Guide (485type)

No.EX##-OMJ0001. SI unit for ControlNet PRODUCT NAME. EX250-SCN1 Series MODE/ Series

Suitable for detecting transparent films or transparent bottles

Electrostatic Sensor Monitor IZE11

INSTALLATION MANUAL For authorized service personnel only.

Pressure Sensor Controller PSE300

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

No.EX##-OMN0028. Fieldbus system PROFIBUS DP compatible SI unit PRODUCT NAME. EX600-SPR#A EX600-ED# MODEL/ Series

Fieldbus system EtherNet/IP TM compatible SI Unit

Digital Pressure Switch

DeviceNet Expansion Board

EtherNet/IP TM Compatible Fieldbus System

EX120/121/122 Series Some protocols are not CE-compliant.

Fieldbus system PROFIBUS DP compatible SI unit

Actuator Position Sensor. D-MP# series

Operating instructions IO-Link master CabinetLine AL19xx

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

Controller setting kit Software (ACT Controller)

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

RS-FX-N01 wind transmitter user's Guide (485type)

MPCR Series DeviceNet Technical Manual

No.EX##-OMN0034. Fieldbus system CC-Link compatible SI unit PRODUCT NAME. EX600-SMJ# EX600-ED# MODEL/ Series

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

No.EX##-OMN0032. Fieldbus system EtherNet/IP TM compatible SI unit PRODUCT NAME. EX600-SEN# EX600-ED# MODEL/ Series

Fieldbus system EtherNet/IP TM compatible SI unit

Multi Channel Pressure Sensor Controller PSE200

Fieldbus system (SI unit compatible CompoNet)

NU-DN1. User s Manual. DeviceNet Compatible Network Unit

: EX##-OMC0024-A. Instruction Manual. SI Unit / DI Unit EX240-SDN2 EX240-IE1

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

One step ahead in performance and mounting ease

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

Operating instructions. Standstill monitor A / / 2011

01325T -- Robot Welder

Reduced wiring system. PROFIBUS-DP Compatible GW unit. Operation Manual EX510-GPR1. URLhttp://

Fieldbus system (DeviceNet compliant)

Installation Instructions for DeviceNet E50 Limit Switches

JXC-W1 (JXC#3 Series)

No.EX##-OMN0036. Fieldbus system Digital unit PRODUCT NAME. EX600-DX## EX600-DY## EX600-DM## MODEL/ Series

- 15G0078B120 - DEVICENET MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

DeviceNet Interface Option "OPC-E1-DEV"

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

INSTRUCTION SHEET. Eaton Logic Controller DeviceNet Distributed I/O Adapter Module. [Applicable Distributed I/O Adapter Module] ELC-CADNET

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

DeviceNet Interface Card "OPC-F1-DEV"

Operating instructions. ProcessLine analogue module AC / / 2012

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

LCD Readout Digital Pressure Switch

GB MIX COMUNICAZIONE - MI. Digital Electro-pneumatic Regulator ER Series

Overview of types. Technical data

E2K-X4ME1 2M E2K-X4ME2 2M

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Type Quickstart

MAC VALVES, INC. A ENGINEERING RELEASE TRJ B EDS UPDATE / NAME CHANGE BI 284 TJR/KD. User s Manual for MAC Valves DeviceNet

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

SMI-100 Stack Monitoring Interface Installation & Operation Manual

DeviceNet PCI Card Instructions Manual

Data Sheet PS1C Pressure Display and Switch Device

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

EP/2 Installation Instructions

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost.

DeviceNet Drive Profile CFW-09

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

Sigma DeviceNet Tool Change Systems USER S GUIDE Rev 05

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Thread length (overall length) material

Series P215DP Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

DC I/O Conversion Module

Transcription:

OPERATION MANUAL E/P REGULATOR MODEL NAME ITV*0*0 *0*0-DE**** series Series For DeviceNet TM CONTENTS TM Contents Safety Instructions P1 P2 Precautions for Handling P3-4 Wiring and LED display P5-6 Mounting and Installation Switch setting P6 P7 Pressure setting and output monitoring / communication data P8 System configuration / Applications / Specifications Communication specification / Maintenance and inspection P9 P10 SMC Corporation 4-14-1,Sotokanda,Chiyoda-ku,Tokyo 101-0021 JAPAN Tel:+81 3 52078249 Fax:+81 3 52985362 URL http://www.smcworld.com 1

Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of CAUTION AUTION WARNING ARNING or DANGER ANGER. To ensure safety, be sure to observe ISO 4414 and other safety practices. Definition Label Meaning of label!! WARNING CAUTION Operator error could result in serious injury or loss of life. Operator error could result in injury or equipment damage.! WARNING 1 The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment. 2 Only personnel with appropriate training should operate machinery and equipment. Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. 3 Do not service machinery/equipment or attempt to remove the product until safety is confirmed. A. Inspection and maintenance of machinery / equipment should only be performed once measures to prevent falling or runaway of the driver objects have been confirmed. B. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply pressure for this equipment and exhaust all residual compressed air in the system. C. Before machinery / equipment is restarted, take measures to prevent shooting-out of cylinder piston rod, etc. 4 Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. A. Conditions and environments beyond the given specifications, or if product is used outdoors. B. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuit in press applications, or safety equipment. C. An application which has the possibility of having negative effects on people, property, or animals requiring special safety analysis. 2

Precautions for Handling! CAUTION If the power supply for this product is cut due to a power failure during controlling, the output of the secondary side is held temporarily. If the secondary side output is released to the atmosphere, air will keep coming out. Handle with care. If the pressure supply is cut while power is supplied, the built in solenoid valve will keep operating and may make a buzzing noise. This may affect the life of the solenoid valve. Be sure to cut the power supply to the product when cutting the pressure supply. The product is adjusted to each specification at the time of shipment from the factory. Avoid unnecessary disassembly or removal of parts, as this may cause failure. 3

! CAUTION Take the following measures against malfunction due to noise. 1) Install a line filter in the AC power supply line to remove noise. 2) Separate the signal lines from any intense electric field such as motor lines and power transmission lines as far as possible so as not to be affected by noise. 3) For inductive loads such as solenoid valves and relays, make sure to take measures against load surge. 4) Ensure the power supply is cut before removing the connector, to avoid the impact of chattering. The right angle cable connector does not rotate. Do not rotate it. 4

Wiring and LED display Pin assign of ITV side connector! CAUTION 1 Incorrect wiring may lead to breakage. 2 Insert/pull out the connector after cutting the power supply. 3 In the communication cable(5 pins)is connected to the connector for the power supply cable(4 pins) by mistake, the internal substrate can break. Pay attention for connecting the cable. 4 The right angle cable connector does not rotate. Do not rotate it. Item Pin assign Wire color (Note 1) 4 1.+24[V] Brown Power supply 3 2.N.C. - connector 1 3.GND Blue 2 4.N.C. - 4 1.DRAIN - 3 2.V+ Red Communication 3.V- Black connector 1 5 2 4.CAN_H White 5.CAN_L Blue Note1) Wire color when the option cable is used. Connection to external equipment Communication wiring diagram Master PLC 1:DRAIN 2:V+ 3:V- 4:CAN_H 5:CAN_L Power supply wiring diagram + Power Supply DC24V - 2:N.C. 1:+24V N.C. Note2 4:N.C. 3:GND N.C. Note2 Note 2: The power cable recommends the 2-wire cable P398020-504-3(S type) or P398020-505-3 (L type). Please never wire for neither pin 2 nor pin 4 when you use other 4-wire cables. An internal substrate might be damaged. The communications cable recommends the use of our company PCA-1557633. Select a DC power supply with adequate capacity with low ripple. Ex. : Class 2 voltage source. UL1310 compliant. For communication master (PLC), we recommend using a product for Device Net communication with SELV circuit which is compliant to IEC 60950-1, electrical safety standard. 5

POWER LED MOD/NET LED Connector for Communication Connector for Power supply Switch cover LED indication Item Turning ON Blinking Turning OFF POWER Power ON(Green) Power OFF ON line(green) Communication unestablishment (Green) MOD/NET Fatal error(red) Negligible error(red) (I/O connection time out) OFF line Mounting and Installation Installation Direct mounting When the product is mounted directly onto the panel or device, use screws suitable for the thread holes below. (See drawing on the right) Series Mounting thread Tightening hole torque ITV1000 M4 0.7 (Depth 6) 2~3N m ITV2000, M5 0.8 (Through) 5~6N m ITV3000 Bracket mounting When the bracket is mounted to the product for mounting it onto the panel or device, Direct mounting Bracket mounting fix the bracket to the product with the screws provided. (See table above for tightening torque). The hole of φ7 has become empty in the bracket for a fixed screw. Connector mounting When mounting the connector with cable to the product, match up the position of the connector groove (cable side) and key (product side). Communication connector key Power supply connector key 6

Switch setting Safety Instructions for Setting Turn off the power supply while setting the switch. If there is foreign matter or water droplets around the switch cover, clean it off before opening the cover. Refer to the drawing below for the setting at the time of shipment from the factory. Confirm the condition of switches before use and reset if necessary. Setting procedure 1Loosen the screws of the switch cover. 2Open the cover from the bottom upwards (See drawing) 3Set switch referring to the setting procedure below. 4After setting the switch, tighten the switch cover 90 in the reverse order of the above procedure. (Tightening torque 0.6 to 0.8Nm) Setting of DIP switch Please execute the settings of the range of MAC ID and the baud rate, with the dip switch in ten poles. 1 2 3 4 5 6 7 8 9 10 1 0 MSB MAC ID=0~63 Baud rate 00:125 kbps 01:250 kbps 10:500 kbps LSB Note Setting method 0:Setting by switch 1:Setting by software MAC ID and baud rate is set by way of the network. When the communication error 0:Clear output pressure 1:Hold output pressure Note: 1.This switch is selected to hold or clear the output pressure. When the D-Net line causes a communication error do to disconnection. 2.When switching off the power supply to ITV in the communication, output pressure is maintained. The condition that the communication begins from power supply re-investing time depends on the setting of dip switch No.9. Setting when factory is shipped OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF 1 2 3 4 5 6 7 8 9 10 7

Pressure setting and output monitoring Pressure can be set by sending the input data, in which F.S. consists of 12 bits, to the E/P regulator through master PLC(target value to word area). Setting Date 0000h 0FFFh [(a/f.s.) 4095] HEX Output pressure 0% F.S.(=0) 100% F.S. a EX.) To set pressure at 0.3MPa by ITV2030(for 0.5MPa type) (0.3MPa/0.5MPa) 4095=2457(DEC)=999(HEX) 0.3MPa of pressure is set by sending input data of 999 to the electromagnetic regulator through the master PLC. Pressure 100% 75% 50% 25% 0% 0 1023 2047 3071 4095 (DEC) 000 3FF 7FF BFF FFF (HEX) Input data Communication data I/O data(poll command sending and receiving data) Output Input Item (Poll request) (Poll response) Data size 2Byte(16bit) 2Byte(16bit) Communication data b 15,b 14, b 1,b 0 b 15,b 14, b 1,b 0 The I/O data occupies two bytes respectively. The pressure is set (output) or is monitored(input) by the data of b 15, b 1,b 0. Subordinate position 12bit b 11 b 0 corresponds to 100%FS of pressure. The pressure setting is assumed that data 17FEh of 150%FS is a limit value. The accuracy guarantee : to 100%FS. 8

System configuration / Applications This product is connected to the field bus (DeviceNet TM ) as a slave. Master Power SUP.(DC24V) DeviceNet Slave1 Slave2 The compress air is supplied from the first side. The pressure proportional to the signal on the second side is obtained. < Example of system configuration > As shown in the structure example above, this product is to control air pressure for pneumatic equipment. Do not use it for any other application. Specifications Model Minimum supply pressure ITV1010 ITV1030 ITV1050 - ITV2010 ITV2030 ITV2050 ITV2090 ITV3010 ITV3030 ITV3050 - Set pressure + 0.1MPa Set pressure -13.3kPa Maximum supply pressure 0.2MPa 1.0MPa 1.0MPa -101kPa Set pressure range 0.005~0.1MPa 0.005~0.5MPa 0.005~0.9MPa -1.3~-80kPa Power Voltage DC24V±10% source Current consumption 0.14A or less Linearity Hysteresis Repeatability Sensitivity ±1%F.S. or less 0.5%F.S. or less ±0.5%F.S. or less 0.2%F.S. or less Temperature characteristics Operating temperature Standards Enclosure ±0.12%F.S. or less/ 0 to 50 (No dew condensation) CE marking, UL(CSA) IP65 Model ITV10 0 ITV20 0 ITV30 0 ITV2090 Size (mm mm mm) 50 50 109 50 50 131 66 66 152 50 50 137 Weight (No option) 320g 420g 720g 460g 9

Communication specification Item Specifications Remarks Field bus DeviceNet TM Volume1(Edition3.8) Volume3(Edition1.5) EDS file ITV-A.EDS Slave type Group 2 Only Device type 00h(Generic Device) MAC ID 0 to 63 Due to the dip switch or the master Baud rate (Note) 125k/250k/500k/ bps Due to the dip switch or the master Consumed connection size 2byte (pooled I/O connection) Target value of pressure Produced connection size 2byte (pooled I/O connection) Pressure monitor value Support message Polled I/O Explicit Note) Baud rate relates to communication distance. Maintenance and inspection Turn off the power supply, stop the supplied air, exhaust the residual compressed air and verify the release of air before performing maintenance. Foreign matter caught in the inlet of piping or exhaust may interfere with normal operation. Periodic cleaning is necessary. Do not use solvents such as benzene, thinner etc. to clean the product including the switch cover. Use a soft cloth to remove stains. This document describes the general purpose product. Some parts may differ for particular special products. This manual is subject to change without prior notice. 10 ITV2-OM000 OM00095