Step Motor Controller

Similar documents
Step Motor Controller

Step Motor Controller

Multi-Axis Step Motor Controller

Step Motor Controller

4 Axis Step Motor Controller

Programless Controller (With Stroke Study) How to Order

Multi-Axis Step Motor Controller

Connection Guide. SMC Corporation. EtherCAT(R) Machine Automation Controller NJ-series

Controller/Driver. Series LECP6. Series LECA6. Series LEC-G. Series LECPMJ. Series LECP1. Series LECPA. Step Data Input Type Page 386

Controller/Driver. Series LECm. Step Data Input Type Page 551. Gateway Unit Page 563 Programless Type Page 567

No.JXC -OMU0008-A PRODUCT NAME. EtherCAT Direct input type Step Motor Controller (Servo 24VDC) Model / Series / Product Number JXCE1

No.JXC -OMT0006-A PRODUCT NAME. PROFINET Direct input type Step Motor Controller (Servo 24VDC) Model / Series / Product Number JXCP1

No. JXC -OMU0026. Product name. 3-axis Step Motor Controller (EtherNet / IP TM type) MODEL/ Series/ Product Number. JXC92 Series

EX120/121/122 Series Some protocols are not CE-compliant.

Multiply your control Multi-axis step motor controller JXC92, JXC73/83/93 Series

Series LECP6. Step Motor Controller (Servo/24 VDC) LEHZ LEHF LEHS. LECP6 Specific Product Precautions. Options. I/O cable PLC

240 g. 290 g. Compact and lightweight Rod Type Series LEPY. Electric Actuators. New. Series LEPY/LEPS

Power supply unit PLC. Gateway unit. 4 axes

Step Motor Controller (Servo / 24 VDC) LECP6 Series

Doc. no.lec-om PRODUCT NAME Programless controller Step motor (servo 24 VDC ) MODEL/ Series LECP1 Series

Information. For Electric Actuators Fieldbus-compatible Gateway (GW) Unit

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

For Output. Series EX120/121/122. Small unit compatible with maximum 16 outputs Compatible with a variety of communication networks

Electric Actuator Slider Type

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

EX12 -SCS1 EX12 -SCS2 EX12 -SSL1. SSL1: 0/16 SSL2: 0/8 Not provided 11 to 25 VDC 15 to 30 VDC 14 to 26.4 VDC 24 VDC+10%/ 5% 24 VDC+10%/ 5%

Fieldbus System (For Input/Output)

Motor controllers CMMO-ST

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Measuring modules CPX-CMIX

Motorized Linear Slides/ Motorized Cylinders Common Controller

Doc. no. LEC-OM PRODUCT NAME Programless controller (with stroke study) Step motor (servo 24 VDC ) MODEL/ Series LECP2 Series

Controller CMXH-ST2 Key features

Electric Slide Table. Series LES. Compact, Space-saving (61% reduction in volume compared to the SMC conventional products)

Series EX120/121/122. Integrated Type/For Output. How to Order SI Unit SV1000/2000/3000/4000 SY3000/5000 SY3000/5000 VQ1000/2000.

Step Motor Driver (Pulse input type)

Information. EX260 Integrated Type (For Output) Serial Transmission System 5 Port Solenoid Valve mm. Series SY/SV/VQC/S0700

Control block CPX-CM-HPP

RCP2 Quick Start Guide

9mm. Card Motor. New. New. Just input 3 parameters: Positioning time, Target position, Load mass. 3 functions in 1 unit 6 N.

Electric Actuator Low profile Slider type

ACSI ACTUATOR CONTROL SOLUTIONS

Electric Actuator Guide Rod Slider

3-position, AC100/200V controller for RCP2/RCP3 Series. 3 position, AC100V controller for RCA/RCA2/RCL Series. Controller. Power supply.

Controller. Network-Compatible Products, Controller F-9 F-9 SCX11. Overview of Controllers F-10 SCX11 F-12. Network- Compatible Products Overview

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet gateway for PROFINET, EtherNet/IP and Modbus TCP BL67-PG-EN-V3

TM3AI4 module TM3-4 analog inputs

Charge Control C Datasheet

RSTI-EP Slice I/O. EtherCAT Network Adapter Module EPXETC001. GFK-2967B Septembery 2016

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

PIO type (PNP Specification) Controller that moves by designating position numbers with PNP PIO via PLC. 16 points

EtherCAT Slave. EtherCAT Data Transition. EtherCAT Tool: TwinCAT. Taiwan Pulse Motion Co.,Ltd

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

Controller setting kit Software (ACT Controller)

TM3TI4 module TM3-4 inputs temperature

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

The transportation, pushing and length measurement systems have been miniaturized through the use of a linear motor. Maximum stroke 50mm

CSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.

Electric Actuator / Low profile slider type

1.5 axis motion controller

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

Operating Manual FPGA-based High-Speed Micro-PLC

Installation Instructions

PMC-1HS/PMC-2HS Series

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

Servo Motor Controller (24 VDC) LECA6 Series

TTA Series. Tabletop Robot. ZR-Axis Type Series Added

INTEGRATED MICROSTEPPING MOTOR DRIVER AND HIGH PERFORMANCE MACHINE/PROCESS CONTROLLER

KFC-200. Installation Guide

Data Sheet MEM 22. Absolute Encoder Multiturn

Mounting Card MC1XDZPC01

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

ACSI ACTUATOR CONTROL SOLUTIONS

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

Motor controllers CMMS-ST, for stepper motors

Rotary Measurement Technology Absolute Encoders, Singleturn

TM3TM3 module TM3-2 temperature inputs and 1 analog output

Controllers. Stepping Motors C-269. Stepping Motors Introduction AS ASC. EMP400 Series SG8030J. EMP400 Series C-274 SG8030J C-289

EtherCAT Remote I/O Terminal GX series

Data Sheet MEM 16. Absolute Encoder Multiturn

Enhanced communication

TM3TI8T module TM3-8 inputs temperature

Rotary Measuring Technology Absolute encoders, Multiturn, DeviceNet

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Communications & Networking

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

EY-RU 355: Room operating unit, ecounit355

Program controller for operating RCA2/RCA Series actuators. One unit can handle various controls. Up to 2 axes

Electric Actuator Miniature Rod Type Miniature Slide table Type. LEPY Series

FLEX Ex Spring Clamp Terminal Base

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Doc. no. LEC-OM00501 PRODUCT NAME. Teaching Box for Electric actuator. MODEL / Series. LEC-T1 Series. Applicable models : For Series LECP, Series LECA

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

TS-X/TS-P. Features. 1 Main operation patterns

Transcription:

INFORMATION Step Motor Controller New New New Type Type RoHS Type Type Two types of operation command Transition wiring of communication cables Step no. defined operation: Operate using the preset step data in the controller. Numerical data defined operation: The actuator operates using values such as position and speed from the. Two communication ports are provided. * For the DeviceNet type, transition wiring is possible using a branch connector. Numerical monitoring available Numerical information, such as the current speed, current position, and alarm codes, can be monitored on the. Application Examples Both air and electric systems can be established under the same protocol. Air Cylinders Electric Actuators EX260 Communication protocol <Applicable electric actuators> Slider type LEF Series Electric slide table LES/LESH Series Low profile slider type LEM Series Miniature type LEPY/LEPS Series Guide rod slider Rod type LEL Series LEY/LEYG Series Electric gripper LEH Series Rotary table LER Series JXCE1/91/P1/D1 Series 15-E667

JXCE1/91/P1/D1 Series System Construction Electric actuators LEY/LEYG Series LEF Series LES/LESH Series LER Series LEL Series LEPY/LEPS Series LEH Series LEM Series Communication plug connector for DeviceNet P.6 Straight type T-branch type JXC-CD-S JXC-CD-T Actuator cable Standard cable LE-CP- -S Robotic cable LE-CP- To ENC To SI Power supply for controller 24 VDC To PWR Power supply plug (Accessory) To MOT P.6 Options Conversion cable P.6 Teaching box (With 3 m cable) LEC-T1-3JG or Controller setting kit Controller setting kit (Communication cable, conversion unit, and USB cable are included.) LEC-W2 Communication cable (3 m) Conversion cable 1 P5062-5 (0.3 m) P.6 The conversion cable can be used for connecting this controller to the optional teaching box [LEC-T1] or the controller setting kit [LEC-W2] offered with the LEC series. PC USB cable (A-mini B type) (0.3 m) 1 To connect the teaching box or LEC controller setting kit communication cable to the controller, a conversion cable is required. 1

Step Motor Controller JXCE1/91/P1/D1 Series Actuator + Controller How to Order LEFS16B-100 Actuator type Refer to How to Order in the actuator catalog. For compatible actuators, refer to the table below. Example: LEFS16B-100B-R1C917 R1 CD17T Controller JXC D 1 7 T LEFS16B-100 Precautions for blank controllers (JXC 1 -BC) A blank controller is a controller to which the customer can write the data of the actuator it is to be combined and used with. Use the dedicated software (JXC-BCW) for data writing. Please download the dedicated software (JXC-BCW) via our website. Order the controller setting kit (LEC-W2) separately to use this software. SMC website http://www.smcworld.com Compatible actuators Electric Actuator/Rod LEY Series Electric Actuator/Guide Rod LEYG Series Electric Actuator/Slider LEF Series Electric Slide Table LES/LESH Series Electric Rotary Table LER Series Electric Actuator/Guide Rod Slider LEL Series Electric Actuator/Miniature LEPY/LEPS Series Electric Gripper LEH Series Electric Actuator/Low Profile Slider LEM Series * Only the step motor type is applicable. Caution [CE-compliant products] EMC compliance was tested by combining the electric actuator LE series and the JXCE1/91/P1/ D1 series. The EMC depends on the configuration of the customer s control panel and the relationship with other electrical equipment and wiring. Therefore, compliance with the EMC directive cannot be certified for SMC components incorporated into the customer s equipment under actual operating conditions. As a result, it is necessary for the customer to verify compliance with the EMC directive for the machinery and equipment as a whole. Communication protocol E EtherCAT 9 EtherNet/IP P PROFINET D DeviceNet For single axis Mounting 7 Screw mounting 8*1 DIN rail *1 DIN rail is not included. It must be ordered separately. (Page 6) Refer to the Web Catalog. Actuator cable type/length Nil Without cable S1 Standard cable 1.5 m S3 Standard cable 3 m S5 Standard cable 5 m R1 Robotic cable 1.5 m R3 Robotic cable 3 m R5 Robotic cable 5 m R8 Robotic cable 8 m*1 RA Robotic cable 10 m*1 RB Robotic cable 15 m*1 RC Robotic cable 20 m*1 *1 Produced upon receipt of order (Robotic cable only) * The standard cable should only be used on fixed parts. For use on moving parts, select the robotic cable. Controller Nil Without controller Cm1mm With controller C Communication protocol E EtherCAT 9 EtherNet/IP P PROFINET D DeviceNet D For single axis 1 Mounting 7 Screw mounting 8*1 DIN rail 7 T *1 DIN rail is not included. It must be ordered separately. (Page 6) Communication plug connector for DeviceNet Nil Without plug connector S Straight type T T-branch type * Select Nil for anything other than DeviceNet. When selecting an electric actuator, refer to the model selection chart of each actuator. Also, for the Speed Work Load graph of the actuator, refer to the LECPMJ section on the model selection page of the electric actuators Web Catalog. Communication plug connector for DeviceNet Nil Without plug connector S Straight type T T-branch type * Select Nil for anything other than DeviceNet. Actuator part number Without cable specifications and actuator options Example: Enter LEFS16B-100 for the LEFS16B- 100B-S1mm. BC Blank controller*1 *1 Requires dedicated software (JXC-BCW). When selecting an electric actuator, refer to the model selection chart of each actuator. Also, for the Speed Work Load graph of the actuator, refer to the LECPMJ section on the model selection page of the electric actuators Web Catalog. 2

JXCE1/91/P1/D1 Series Specifications Model JXCE1 JXC91 JXCP1 JXCD1 Network EtherCAT EtherNet/IP PROFINET DeviceNet Compatible motor Step motor (Servo/24 VDC) Power supply Power voltage: 24 VDC ±10% Current consumption (Controller) 200 ma or less 130 ma or less 200 ma or less 100 ma or less Compatible encoder Incremental A/B phase (800 pulse/rotation) Applicable Protocol EtherCAT *2 EtherNet/IP *2 PROFINET*2 DeviceNet system Version*1 Specification Version 2.32 Communication specifications Conformance Test Record V.1.2.6 Volume 1 (Edition 3.14) Volume 2 (Edition 1.15) Volume 1 (Edition 3.14) Volume 3 (Edition 1.13) 10/100 Mbps*2 Communication speed 100 Mbps*2 (Automatic negotiation) 100 Mbps*2 125/250/500 kbps Configuration file*3 ESI file EDS file GSDML file EDS file I/O occupation area Input 20 bytes Input 36 bytes Input 36 bytes Input 4, 10, 20 bytes Output 36 bytes Output 36 bytes Output 36 bytes Output 4, 12, 20, 36 bytes Terminating resistor Not included Memory EEPROM LED indicator PWR, RUN, ALM, ERR PWR, ALM, MS, NS PWR, ALM, SF, BF PWR, ALM, MS, NS Cable length [m] Actuator cable: 20 m or less Cooling system Natural air cooling Operating temperature range [ C] 0 to 40 (No freezing) Operating humidity range [%RH] 90 or less (No condensation) Insulation resistance [MW] Between all external terminals and the case 50 (500 VDC) Weight [g] 220 (Screw mounting) 210 (Screw mounting) 220 (Screw mounting) 210 (Screw mounting) 240 (DIN rail mounting) 230 (DIN rail mounting) 240 (DIN rail mounting) 230 (DIN rail mounting) *1 Please note that versions are subject to change. *2 Use a shielded communication cable with CAT5 or higher for the PROFINET, EtherNet/IP, and EtherCAT. *3 The files can be downloaded from the SMC website: http://www.smcworld.com MTrademark EtherNet/IP is a trademark of ODVA. DeviceNet is a trademark of ODVA. EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. Example of Operation Command In addition to the step data input of 64 points maximum in each communication protocol, the changing of each parameter can be performed in real time in the numerical data defined operation. <Application example> Movement between 2 points No. Movement mode Speed Position Acceleration Deceleration Pushing force Trigger LV Pushing speed Moving force Area 1 Area 2 In position 0 1: Absolute 100 10 3000 3000 0 0 0 100 0 0 0.50 1 1: Absolute 100 100 3000 3000 0 0 0 100 0 0 0.50 <Step No. defined operation> Sequence 1: Servo ON instruction Sequence 2: Instruction to return to origin Sequence 3: Specify step data No. 0 to input the DRIVE signal. Sequence 4: Specify step data No. 1 after the DRIVE signal has been temporarily turned OFF to input the DRIVE signal. <Numerical data defined operation> Sequence 1: Servo ON instruction Sequence 2: Instruction to return to origin Sequence 3: Specify step data No. 0 and turn ON the input instructions flag (position). Input 10 in the target position. Subsequently the start flag turns ON. Sequence 4: Turn ON step data No. 0 and the input instructions flag (position) to change the target position to 100 while the start flag is ON. The same operation can be performed with any operation command. Sequence 1 Sequence 2 Sequence 3 Sequence 4 3 0 10 100

Step Motor Controller JXCE1/91/P1/D1 Series Dimensions JXCE1 ø4.5 For body mounting (Screw mounting) 32.5 67 1.2 193.2 (When removing DIN rail) 187.3 (When locking DIN rail) 170 152.5 161 64.2 84.2 Mountable on DIN rail ( mm) 17.5 4.5 For body mounting (Screw mounting) (77) JXC91 ø4.5 32.5 67 1.2 (11.5) 193.2 (When removing DIN rail) 187.3 (When locking DIN rail) 170 152.5 161 64.2 84.2 Mountable on DIN rail ( mm) 17.5 4.5 77 4

JXCE1/91/P1/D1 Series Dimensions JXCP1 67 (11.5) ø4.5 32.5 1.2 193.2 (When removing DIN rail) 84.2 187.3 (When locking DIN rail) 170 152.5 161 64.2 Mountable on DIN rail ( mm) 17.5 77 4.5 JXCD1 67 (11.5) ø4.5 32.5 1.2 84.2 193.2 (When removing DIN rail) 187.3 (When locking DIN rail) 170 152.5 161 64.2 Mountable on DIN rail ( mm) 17.5 77 4.5 L 12.5 (Pitch) 5.25 7.5 () (25) 5.5 L Dimensions [mm] No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L 23.5 48 60.5 73 85.5 98 110.5 123 1.5 148 160.5 173 185.5 198 210.5 223 2.5 248 260.5 1.25 5 No. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 36 37 38 39 40 L 273 285.5 298 310.5 323 3.5 348 360.5 373 385.5 398 410.5 423 4.5 448 460.5 473 485.5 498 510.5

Step Motor Controller JXCE1/91/P1/D1 Series Options DIN rail AXT100-DR- For, enter a number from the No. line in the table. (Page 5) Refer to the dimension drawings (Page 5) for the mounting dimensions. Conversion cable P5062-5 (Cable length: 0.3 m) DIN rail mounting adapter LEC-3-D0 (with 2 mounting screws) This should be used when a DIN rail mounting adapter is mounted onto a screw mounting type controller afterwards. Power supply plug JXC-CPW The power supply plug is an accessory. 300 Communication plug connector for DeviceNet Straight type JXC-CD-S T-branch type JXC-CD-T Communication plug connector for DeviceNet Terminal name Details V+ Power supply (+) for DeviceNet CAN_H Drain CAN_L Communication wire (High) Grounding wire/shielded wire Communication wire (Low) V Power supply ( ) for DeviceNet Power supply plug Terminal name Function Details 0V Common supply ( ) 6 3 M24V terminal/c24v terminal/emg terminal/ LK RLS terminal are common ( ). M24V Motor power supply (+) Motor power supply (+) of the controller C24V Control power supply (+) Control power supply (+) of the controller EMG Stop (+) Connection terminal of the external stop circuit LK RLS Lock release (+) Connection terminal of the lock release switch 5 2 4 1 1 C24V 2 M24V 4 0V 5 N.C. 3 EMG 6 LK RLS 6

Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.