User Manual. KE-Relay or KD-Relay Profibus DPV0 Communication Module. Page 1 / 18. KE-PROFI-DP0 Version (NE_NC-KE-PROFI-DP0_MAN_01_10_FN04)

Similar documents
User Manual. KD-Relay Remote Display 4x20 Display. KD-RDU-420 Version (NE_KD-RDU-420_MAN_00_11_FN02) 01 February 2011

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators

User Manual. KD/KE-Relay Man Machine Interface 4x20 Display. (Explosion Proof) KE-MMI-420-EP Version (NE_KX-MMI-420_MAN_01_10_FN01) 14 June 2010

EMIS ProLoc II Motor Protection Relay. User Manual

SK TU4-PBR Part number:

SK CU4-PBR-C Part number:

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

Operator Manual for Profibus

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

SMART RELAY SRW 01 V4.0X

General information. Supply voltage

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

PACSystems* RX3i IC695PBM300

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

Earth Continuity Monitor

General information. Supply voltage. Input current

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

M550 & M560 MOTOR PROTECTION RELAY

MU110-6U. Analog output module 6 channel. User guide

SK TU4-CAO-C Part number:

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

VersaMax IP Input Module

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Basics of setting up. PROFIBUS-PA networks. Martin Ruck Siemens. Jason Nicholl Phoenix. Kris Hardaker United Utilities

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

SIOX Four I/O Mini Module

Product type designation. General information. Supply voltage

SK CU4-PNT-C Part number:

Product type designation. General information. Supply voltage. Input current. Power loss

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

Intrinsically Safe Barriers

Operation manual. HDOM-Profibus-V0. More options please visit;

SIPLUS CPU 313C-2DP. Function

FPU-16 A-B PROTOCOL/DATA LOGGER MANUAL

SK CU4-CAO Part number:

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

EL731 PROFIBUS INTERFACE

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

G3 Series PROFIBUS DP Technical Manual

SIRIUS Motor Management and Control Devices

SK CU4-ECT-C Part number:

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

Product Description. Altus S. A. 1

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

SK CU4-EIP-C Part number:

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

Metasys N2 Instruction Manual VLT Adjustable Frequency Drive. 12/ Revision B

Copyright: December 2017 Nidec Issue: E

Protection relays.

GE Power Management. MMII Intelligent MCC Controller

Data sheet VIPA CPU 115DP (115-6BL22)

Max Felser. PROFIBUS Manual. mmww. swwmt. A collection of information explaining. PROFIBUS networks

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

AS-i Safety Output Module, IP20

Optidrive Applications Support Library

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

H 250 with PROFIBUS-PA signal converter ESK3-PA

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

CAN 300 PRO, Communication Module

Quick installation guide

USER GUIDE ARDBOX ANALOG

Electronic earth leakage protection relay

PAC BI-DP BIM and 8701-CA-BI Carrier

MODBUS PLUS TO SIEMENS G110/G120/MM440 APPLICATION

RSTI-EP Slice I/O. Digital Output Module

LM10 to MM200 Retrofit

DUAL LOOP DETECTOR WITH MODBUS COMMUNICATIONS

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

INTRODUCING THE S V ADJUSTABLE SPEED DRIVE

PROFIBUS Workshop EN B U I L D I N G P R O C E S S M A N U F A C T U R I N G EUROPEAN FIELDBUS STANDARD. Chapter 1 Date 11/04/99, page 1

MIC-2 MKII, Multi-instrument DATA SHEET

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

PROFIBUS Technology Products

Accessories. Embedded Control. Order number: Flash-RAM memory module, 128 K x 16 (for 680I) Accessories

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Data sheet CC 03, Commander Compact (603-1CC21)

vacon nx ac drives brake chopper unit (bcu) application user s manual

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

- 15G0078B110 - PROFIBUS MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

MIC-2 Multi-instrument DATA SHEET

Profinet Module. User Manual. Contents

General information. Supply voltage. Input current

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

VLT 2800 DRIVE SPECIFICATIONS

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

CIO-777-PR Programming Guide

Optidrive Applications Support Library

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

SIMATIC. ET 200S IM CPU Interface Module. Introduction. New features 2. Technical specifications 3. Product Information 06/2007 A5E

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Transcription:

Page 1 / 18 KE-Relay or KD-Relay Profibus DPV0 Communication Module User Manual Version 01.04 (NE_NC-_MAN_01_10_FN04) 28 June 2010 NewElec Pretoria (Pty) Ltd Head Office: c/o 298 Soutter street & Maltzan street Pretoria West South-Africa 0182 GPS: 25 45'12''S 28 09'46''E Http://www.newelec.co.za

Page 2 / 18 Content 1. ABSTRACT...3 2. SPECIFICATIONS...4 2.1 Technical Specifications of...4 2.2 Structure Of The Parametrization Telegram...5 2.2.1 KE-Relay Pointer Table...8 2.2.2 Input Pointers 1...10 2.3 Cyclic Out Byte...12 2.4 Diagnostics...13 3. DEFINITIONS AND TERMINOLOGY...14 4. FUNCTIONAL DESCRIPTION...15 5. OPERATING INSTRUCTIONS...16 5.1 Getting Started...16 5.1.1 Setting Up The...16 5.1.2 Installing Of NC-MK1-PROFI-DP1 GSD File...16 6. DIAGRAMS...17 6.1 Block Diagram of NC-MK1-PROFI-DP1...17 7. PROFIBUS GSD REGISTERED...18

Page 3 / 18 1. ABSTRACT The (KE or KD-Relay Profibus DPV0) acts as a translator between the Profibus SCADA and the KE or KD-Relay. It is advisable to read the KE or KD user manual, as some of the topics will require knowledge on the KE or KD. It is also advisable to have knowledge on profibus. Information on profibus can be found at the web site www.profibus.com. The communication protocol between the and SCADA is Profibus DPV0 class 1. Communication protocol between the KE-PROFI-DP1 and the KE or KD Relay is a NewElec proprietary protocol. Enabling the PLC to communicate with the KE or KD-Relay via Profibus DPV0.

Page 4 / 18 2. SPECIFICATIONS 2.1 Technical Specifications of General Data Mounting Positions External module. Allowed Ambient Temperature Operation : 0 ºC to +60 ºC Humidity < 87% NC-MK1- PROFI-DP0 Power Supply 220 Vac 110 Vac Consumption 180 ma Communication Mediums Profibus RS232 Profibus Protocol Profibus DPV0 Baud Rate 9600 bit/s to 12 Mbit/s Cable Length @ Baud Rate 1200 m @ 9600 bit/s to 45450 bit/s 1000 m @93.75Kbit/s to 187.5Kbit/s 400 m @ 500 Kbit/s 200 m @ 1.5 Mbit/s 100 m @ 3 Mbit/s to 12 Mbit/s Termination Resistor 220 Ohm. (Termination resistors must be connected at the beginning and end of bus) Indication Type Light Emitting Diode (LED) Lights LED Indications SCADA Communication KE or KD Communication

Page 5 / 18 2.2 Structure Of The Parametrization Telegram The parametrization telegram data will look as follow: Byte Addr Parameter Name 1 Profibus Config A Description Configuration byte of the : Bit 0 = Parametrize Settings. Bit 1 = Parametrize Logic Function. Bit 2 ~ 6 = Reserved. Bit 7 = Fail Safe Disabled. Range 2 Din Amount of words from the Relay to the SCADA. 1 ~ 5 3 ~ 7 Word 1 ~ 5 To SCADA Pointer to KE-Relay Pointer Table (2.2.1). 0 ~ 12 8 Unbalance Trip Level Trip level for unbalance in %. 0 ~ 100 9 Unbalance Trip Delay Unbalance trip delay in seconds. 0~99 10 Voltage selection Select the line voltage of the relay. 0 = Auto. 1 = 110 Vac. 2 = 400 Vac. 3 = 525 Vac. 4 = 1050 Vac. Set 0 ~ 4 11 Volt. Sym. Trip Level Voltage symmetric trip level in %. 0 ~ 100 12 Starts Per Hour Amount of starts that can be taken in a hour. 1 ~ 30 13 Consecutive Starts Amount of starts to be take after a failed start attempt. 1 ~ 3 14 ~ 15 Earth Leak Trip Level Earth leakage trip level in ma. 0 ~ 999 16 ~ 17 Earth Leak Trip Delay 18 Earth Leakage Trip Type Delayed time for earth leakage in ms with 50 ms incremental. Type of earth leakage trip. 0 = Instantaneous. 1 = IDMT. 100 ~ 1000 0 ~ 1 19 Max. Load Setting Maximum load setting of the relay in %. 10 ~ 100 20 TC Curve Thermal capacity curve selected in %. 3 ~ 40 21 TC Reset Threshold Thermal capacity reset level in %. 1 ~ 10 22 ML Reset Timer Time to reset the relay after minimum load trip. 0 = Manual. 1 = 10 Seconds. 2 = 5 Minutes. 3 = 10 Minutes. 4 = 20 Minutes. 0 ~ 9

Page 6 / 18 5 = 30 Minutes. 6 = 45 Minutes. 7 = 1 Hour. 8 = 3 Hours. 9 = 6 Hours. 23 ML Current Trip Level Minimum load trip level in %. 0 ~ 100 24 ML Power Trip Level Minimum load power trip level %. 0 ~ 100 25 ML Startup Trip Delay Time to delay minimum load trip at start up in seconds. 1 ~ 200 26 ML Trip Delay Delay run time trip delay in seconds. 0 ~ 10 27 ~ 28 Running Stall Level Running stall trip level in %. 110 ~ 300 29 ~ 30 Run. Stall Hold Time Running stall hold off time in seconds. 0 ~ 200 31 Control Byte A 32 Control Byte B 33 Control Byte C Control byte A: Bit 0 = Minimum load disabled. Bit 1 = Under voltage disabled. Bit 2 = Over voltage disabled. Bit 3 = Voltage Symmetric disabled. Bit 4 = Fail safe disabled. Bit 5 = Unbalance disabled. Bit 6 = Phase rotation disabled. Bit 7 = Short circuit disabled. Control byte B: Bit 0 = Single phase disabled. Bit 1 = Running stall disabled. Bit 2 = ML = power factor selected. Bit 3 = Earth leakage disabled. Bit 4 = Low pass filter disabled. Bit 5 = Insulation lockout disabled. Bit 6 = Frequency disabled. Bit 7 = Auto calc. TC reset disabled. Control Byte C: Bit 0 = Starts per hour disabled. Bit 1 = Phase rotation reversed. Bit 2 = Vectorial stall disabled. Bit 3 = Auto reset. Bit 4 ~ 7 = Reserved. 34 Logic Function 1 Mask Logic function 1 mask register. 0 ~ 255 35 LF 1 A Input pointer Input Pointers 1 (2.2.2). 0 ~ 50 36 LF 1 B Input pointer Input Pointers 1 (2.2.2). 0 ~ 50 37 LF 1 C Input pointer Input Pointers 1 (2.2.2). 0 ~ 50

Page 7 / 18 38 Logic Function 2 Mask Logic function 2 mask register. 0 ~ 255 39 LF 2 A Input pointer Input Pointers 1 (2.2.2). 0 ~ 50 40 LF 2 B Input pointer Input Pointers 1 (2.2.2). 0 ~ 50 41 LF 2 C Input pointer Input Pointers 1 (2.2.2). 0 ~ 50 42 Logic Function 3 Mask Logic function 3 mask register. 0 ~ 255 43 LF 3 A Input pointer Input Pointers 1 (2.2.2). 0 ~ 50 44 LF 3 B Input pointer Input Pointers 1 (2.2.2). 0 ~ 50 45 LF 3 C Input pointer Input Pointers 1 (2.2.2). 0 ~ 50 46 ~ 47 Timer A Time Out Time for timer A to time out in seconds. 0 ~ 3000 48 Timer A Start Input Ptr Input Pointers 1 (2.2.2). 0 ~ 50 49 Timer A Stop Input Ptr Input Pointers 1 (2.2.2). 0 ~ 50 50 ~ 51 Timer B Time Out Time for timer B to time out in seconds. 0 ~ 3000 52 Timer B Start Input Ptr Input Pointers 1 (2.2.2). 0 ~ 50 53 Timer B Stop Input Ptr Input Pointers 1 (2.2.2). 0 ~ 50 54 RTC Start Hour Real time clock start hours. 0 ~ 23 55 RTC Start Minutes Real time clock start minutes. 0 ~ 59 56 RTC Stop Hour Real time clock stop hours. 0 ~ 23 57 RTC Stop Minutes Real time clock stop minutes. 0 ~ 59 58 Relay 2 Input Ptr Input Pointers 1 (2.2.2). 0 ~ 50

Page 8 / 18 2.2.1 KE-Relay Pointer Table Values that can be routed to for the PLC words in 1 to 5. Address Name 0 TC remaining 1 Current Level. 2 Red Phase Voltage Level. 3 White Phase Voltage Level. 4 Blue Phase Voltage Level. 5 Actual Power 6 Alarm Flags Bit 0 = In Service. Bit 1 = Earth Leakage. Bit 2 = Over Current. Bit 3 = Running Stall. Bit 4 = Unbalance. Bit 5 = Single Phase. Bit 6 = Minimum Load. Bit 7 = Short Circuit. Bit 8 = Voltage Present. Bit 9 = Over Voltage. Bit 10 = Under Voltage. Bit 11 = Voltage Symmetric. Bit 12 = Insulation Lockout. Bit 13 = Low Frequency. Bit 14 = High Frequency. Bit 15 = Earth Fault. 7 Trip Flags Bit 0 = Over Current. Bit 1 = Running Stall. Bit 2 = Unbalance. Bit 3 = Single Phase. Bit 4 = Minimum Load. Bit 5 = Short Circuit. Bit 6 = Phase Rotation. Bit 7 = Earth Fault. Bit 8 = Over Voltage. Bit 9 = Under Voltage. Bit 10 = Voltage Symmetric. Bit 11 = Insulation Lockout..

Page 9 / 18 Bit 12 = Low Frequency. Bit 13 = High Frequency. Bit 14 = Earth Fault. Bit 15 = Starts Per Hour. 8 Voltage Symmetric Level 9 Earth Leakage Level. 10 Frequency 11 Insulation Lockout 12 Function Flags. Bit 0 = Logic Function 1. Bit 1 = Logic Function 2. Bit 2 = Logic Function 3. Bit 3 = Timer A. Bit 4 = Timer B. Bit 5 = Real Time Clock. Bit 6 = Main Trip Relay. Bit 7 = Relay 2. 13 Apparent Power Consumption 14 Real Power Consumption

Page 10 / 18 2.2.2 Input Pointers 1 It is signals that can be routed to the inputs of the logic functions, timers and relays. Address Name 0 Constant Zero 1 Constant One 2 In Service Flag 3 Voltage Present Flag 4 Over Current Alarm Flag 5 Short Circuit Alarm Flag 6 Running Stall Alarm Flag 7 Unbalance Alarm Flag 8 Single Phase Alarm Flag 9 Earth Fault Alarm Flag 10 Earth Leakage Alarm Flag 11 Minimum Load Alarm Flag 12 Over Voltage Alarm Flag 13 Under Voltage Alarm Flag 14 Voltage Symmetric Alarm Flag 15 High Frequency Alarm Flag 16 Low Frequency Alarm Flag 17 Insulation Lockout Alarm Flag 18 Over Current Trip Flag 19 Short Circuit Trip Flag 20 Running Stall Trip Flag 21 Unbalance Trip Flag 22 Single Phase Trip Flag 23 Earth Fault Trip Flag 24 Earth Leakage Trip Flag 25 Minimum Load Trip Flag 26 Over Voltage Trip Flag 27 Under Voltage Trip Flag 28 Voltage Symmetric Trip Flag 29 High Frequency Trip Flag 30 Low Frequency Trip Flag 31 Insulation Lockout Trip Flag 32 Phase Rotation Trip Flag

Page 11 / 18 33 Starts Per Hour Trip Flag 34 Timer A Output 35 Inverted Timer A Output 36 Timer B Output 37 Inverted Timer B Output 38 RTC Output 39 Inverted RTC Output 40 Logical Function 1 Output 41 Inverted Logical Function 1 Output 42 Logical Function 2 Output 43 Inverted Logical Function 2 Output 44 Logical Function 3 Output 45 Inverted Logical Function 3 Output 46 Restart Flag 47 Frozen Contact Flag 48 PLC Bit 0 49 PLC Bit 1 50 TC > TC warning level.

Page 12 / 18 2.3 Cyclic Out Byte The message from the PLC to the slave will look as follow: Byte :: Bit Description 0::0 PLC bit 0 0::1 PLC bit 1 0::2 ~ 5 Reserved 0::6 Reset Relay 0::7 Fail safe communication between relay and slave is disabled

Page 13 / 18 2.4 Diagnostics Diagnostic message will look as follow: Byte Description 0 ~ 2 Station status as per DP specifications. 3 Master profibus address. 4 ~ 5 Manufacture ID. 6 Diagnostic Length. 7 ~ 8 Alarm Flags. 9 ~ 10 Trip Flags. 11 Function Flags 12 Profibus Status. Bit 0 = Communication failure with KE or KD-Relay. 13 ~ 14 Startup Counter. 15 ~ 16 Trip Counter. 17 ~ 18 Running Hour Counter. 19 ~ 20 Apparent Power Consumption. 21 ~ 22 Real Power Consumption.

Page 14 / 18 3. DEFINITIONS AND TERMINOLOGY EEPROM Flash memory In service Intrinsic safe LED Motor protection relay Dout Din KE-PROFI-DP1 PLC Electrical Erasable Programmable Read Only Memory (non volatile) Similar to EEPROM (only block write - non volatile) When the current rise above 10% of full load current it is assumed that the motor is running. It is a protection technique for safe operation of electronic equipment in explosive atmospheres. The concept was developed for safe operation of process control instrumentation in hazardous areas. The theory behind intrinsic safety is to ensure that the available electrical and thermal energy in the system is always low enough that ignition of the hazardous atmosphere cannot occur. Light emitting diode (It is used as visual indicators) It is an intelligent (computerized) unit monitoring an electric motor's current and voltage supply. In case of overloading, phase lost etc. the power supply of the motor will be interrupted by the protection relay to prevent damage to the motor. Data send from the PLC to the slave device. Data received by the PLC from a slave device. KE / KD-Relay Profibus module with DPV0 capability. Programmable Logic Controller.

Page 15 / 18 4. FUNCTIONAL DESCRIPTION The can be broken down into the following function blocks: Micro-Controller KE / KD-Relay Interface. Profibus Interface. Light Emitting Diodes (LED) Micro-Controller Is the core of the system. The micro-controller ensures that the operation of the gets executed. The micro-controller acts as a bridge between the KE / KD-Relay and the PLC. KE / KD-Relay Interface Is the communication bus between the KE / KD-Relay and KE- PROFI-DP0. With the KE / KD-Relay interface it is possible for the two micro-controllers KE / KD-Relay and to exchange data. Profibus Interface Allows the KE / KD-Relay to communicate with the PLC. With the profibus interface it is possible to update the with new values as well as the PLC. Light Emitting Diodes Allows the to indicate conditions to the operator.

Page 16 / 18 5. OPERATING INSTRUCTIONS 5.1 Getting Started 5.1.1 Setting Up The Following must be done via the front-end: Connect the to the front-end via the RS232 port. Set the address of the. Transmit the data to the. 5.1.2 Installing Of NC-MK1-PROFI-DP1 GSD File Following steps must be taken to install the GSD File: Import the NewElec NEWEFF881.gsd into the STEP7 GSD directory. Insert the device into the hardware configuration of the STEP7 program. Set the stations address in the PLC hardware configuration. The address must match the address in the. Set the parametrization of the. Make sure that the cyclic Din matches those of the parametrization bytes.

Page 17 / 18 6. DIAGRAMS 6.1 Block Diagram of NC-MK1-PROFI-DP1 KE / KD-Relay Interface Micro-Controller With Memory Profibus Interface LED

Page 18 / 18 7. PROFIBUS GSD REGISTERED ----ooooo----