Remote Terminal Unit ER1000 APPLICATION FEATURES

Similar documents
SCADAPack ES. Smart RTU

SCADAPack ES. Smart RTU

MINER-S Station Controller. Substation Automation

extending the boundaries of technology evolution of proven technology FEATURES

Scout-S Station Controller

MINER-S Station Controller

RTU32S RTU32S Series Small Compact Utility RTU

RTU32S RTU32S Series Small Compact Utility RTU

NTX Series Product Comparison

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

Bus Bar Protection Relay B-PRO 4000

BITRONICS 878 DIOD Product Description BITRONICS 878 DIOD DISTRIBUTED INPUT/OUTPUT DEVICE

Transformer Protection Relay

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

Communication Gateway COM 610. Product Guide

I/A Series HARDWARE Product Specifications

CPU6501 REV1.0 1 WILLOWGLEN MSC BERHAD

Telecontrol and Automation Systems

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

5OOO Series. Expansion & Communication Modules. Product Selection Guide. Expansion. Communication CONTROL MICROSYSTEMS

RTU & FRTU OF DFE Innovation, Passion, Collaboration, Integrity

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

RTU32R. The versatile RTU and SNMP Alarm and Control Device with advanced control and communication options. Data Sheet. Doc No Version 1.

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

Redundant System Redundant System P9-1-1

VersaMax Micro and Nano Technical Product Presentation

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

Local LCD HMI - View and force I/O, and make simple configuration changes without a computer!

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

ROCON RPC 116. SUBSTATION AUTOMATION Central unit for substation automation

Netcon 500. The Cyber Secure RTU Gateway

Ovation Ethernet Link Controller Module Data Sheet

Asset Management. Facility Management. Total Solutions. Supply Chain Management. Utilities. Series 4500

Data sheet CC 03, Commander Compact (603-1CC21)

An all-in-one module. Archiving Up to 50,000 data items time-and-date stamped and saved to flash memory

D20 Status Input Module

Compact Telecontrol System TM 1703 mic. SICAM 1703 flexible for all applications. Answers for energy.

SCADAPack Smart RTU

SCADAPack 530E 535E. remote Programmable Automation Controller

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Preconfigured SCADA solution: Easy & Powerful

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Orion. An Overview of the Orion Automation Platform

STAND ALONE MERGING UNIT (AMU)

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

IDM DATA ACQUISITION SYSTEM

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

SOLUTIONS FOR AN EVOLVING WORLD RFL GARD Protective Relay & Communications System RFL GARD SFPLC 1

W315 - W320 remote management modules

HECM Modular Input/Output

CG Automation Solutions User Newsletter

PRICOM Power Communication and Control Systems

Features and Benefits. Certifications

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

Hadron Xtorm Series Remote Terminal Units

Features and Benefits. Certifications

SICAM RTUs Ready for the Future

M-2001D DIGITAL TAPCHANGER CONTROL SUGGESTED SPECIFICATIONS

OrionLX. An Overview of the OrionLX Product Line

SCADAPack 350E 357E. Smart Remote Terminal Unit

SCADAPack. I/O Expansion & Communication Modules

Overview. Complete Application-Ready Platforms for General Motion Control Tasks. AMONet - Advantech Distributed Motion Control Solutions 14-2

SEL-2030 Communications Processor

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

TCP. Control and Protection Terminal Data sheet

For Transmission, Distribution and Machinery protection.

RTU300 SERIES HARDWARE MANUAL

Digital Grid Products At a Glance Protection, Substation Automation, Power Quality

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

RTU modules Create your infrastructures with peace of mind!

FEATURES DESCRIPTION FEATURES

RIGHTWON PLUS DESCRIPTION. RightWON Plus Datasheet RWR0x00000-SP-en

CI521 Modbus Communication Interface Module

Appendix D2-262 CPU. In This Appendix...

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Prisma II Platform. Optoelectronics

////// SUBSTATIONS. Control command and local Scada

ProfiMessage. NEW Modular. Secure. Adaptable.

SAGE A powerful distribution automation platform with all the functionality of a gateway. Make the most of your energy SM

Making the decision to switch from PLC to PC-based Control has gotten even easier with the introduction of MachineLogic Control Software.

Multilin P30 Phasor Data Concentrator

CI541 PROFIBUS Communication Interface Module

Programmable Logic Controllers. and Components for Industrial Automation. altus. evolution in automation.

SEL-3332 Intelligent Server

POINT I/O Family. Chapter. Overview

Voltage Transducer UMT516 / MT516

Distributed Control I/O System ADAM-8000 Series

iswitch imotor Compact QR

The PowerLogic range. Gain energy insight and control

Controller Modules Main Feature Part Number MOXoc Dynamic CPU 1x Ethernet MX

Relion 611 series. 611 series Type Test Certificate

protocol can be used. The SB2WEB24 is also equipped with an RS485 port for communication

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

PMC 530 Series Advanced Multifunction Meter

SCADAPack 312E 313E. Smart RTUs for water

Z-PC Line Z-RTU. User Guide

Transcription:

Remote Terminal Unit ER1000 ERL with more than three decades of expertise in Power System Protection have developed state of the art Automation Solutions. The whole family of ERL s Remote Terminal Unit (RTU) and Feeder Remote Terminal Unit (FRTU) covers a broad spectrum of use with products of different sizes for various applications. The ER1000 is specifically architected for use with medium to large numbers of data points, and is well suited across a range of power system applications. ER 1000 Remote Terminal Unit (RTU), the building block of ERL Substation Automation system is designed to meet the present day utility and industry demands. The RTU is built on internationally well proven hardware and software platform. The standard hardware platform gives the necessary ruggedness and the RTOS (Real-Time Operating System) provides the multi-tasking and Real-Time data handling capability. This makes the ER 1000 the state of the art Automation Product of the 21st century APPLICATION ü Gateway for communication between IEDs and Master station. ü Data concentrator for storing data from the IEDs and transferring it to master station. ü Automation unit for building soft logic. ü Station level RTU for hardwired inputs. Add on serial I/O s (RS232 / RS485 software configurable). Add on parallel I/Os (DI, DO, AI, RTD, AO counters etc) High Speed Back Plane Architecture. Equipped with Real-Time Operating System. Equipped with various industrial protocol stacks both at Bay level and Station level. Highly modular in hardware and software design. Redundancy in CPU / Power Supply / Communication Port available. User friendly Configuration Tools for ease of Configuration and Management. FEATURES Flexible soft logic programing 32-bit High performance RISC (Reduced Instruction Set Computing) operating at >80 MHz Core Frequency. Memory SRAM (64Kbytes Internal and 2MB External) FLASH (512Kbytes). On board 10/100 Mbps Fast Ethernet Controller. On board 6 serial I/Os (RS232 and RS485) and 1 Debug Port.

HARDWARE: The Major Hardware Components are 1. Central Processing Unit. 2. Digital Input Module 3. Digital Output Module 4. Analog Input Module 5. Analog Output Module 6. Power Supply Module 7. High Speed Back Plane Serial I/O Module Apart from 6 no of Serial I/O supported by CPU additional serial I/O card (each card supporting 8 no s of RS232 / 485 Software configurable) expansion is possible. Digital Input Module Central Processing Unit 16 Opto Isolated Channels supporting direct field input voltages of 24 / 48 / 110 / 220 VDC. Software Programmable Debounce Timers. Protection against reverse polarity. 1 common for a group of 8 channels. LED indication for each channels for identification of healthiness of field signal and also separate card healthiness indication. The design incorporates dedicated processors to manage the time critical intensive Real-Time process involved in computer control and monitoring environment. (Cold Fire core Processor delivering 76 MIPS at 80 MHz running from internal flash memory with Enhanced Multiply Accumulate (MAC) Unit and hardware divider). The dedicated communication processor provides Real-Time exchange between IEDs of multiple protocols to SCADA systems. The CPU has on board Ethernet port and multiple serial ports and Memory Module. CPU healthiness, Communication Indications etc are provided for easy diagnosis. CPU card supports 6 Serial (2 X RS232, 1 X RS485, 2 X RS232/RS485, 1No. of X RS232 debug port), 1No. of 10/100 Mbps Fast Ethernet and high precision IRIG-B interface for Time Synchronization. On board GPS receiver is supported as an optional feature. Digital Output Module:

16 Single pole relays with one normally open (NO) contact. 8 single pole relays with 1 common. Supports wide range of Inputs such as 24 / 48 / 110 / 220 VDC. Power supply healthy Indication is provided on the Facia. NO and NC contact are provided for alarm Indication. The digital outputs can be configured for single / double / set point outputs on the same module. Rated Current 8A and Breaking Capacity of 2000VA. Rack & Back Plane Analog Input Module 16 Isolated Analog Channels for Measuring Current and Voltages. Both Unipolar and Bipolar Configuration supported for a single card type. Current Range Supported are +/- 20, +/- 10, 0-20 and 4-20 mamp. Voltage Range Supported are +/- 5V, +/- 10V. Power Supply Module The Rack is provided with a high speed intelligent back plane and supports Slot Concept (any card at any slot). Backplane design supports redundancy of CPU and Power Supply modules. Rack and back planes are available in different sizes of 4U 19 and 4U 19/2 (inches) with flush mount arrangement. SOFTWARE Communication Protocol Standard IED Protocols IEC 60870-5-103 Master (Serial) IEC 60870-5-101 Master (Serial) IEC 60870-5-104 Master (TCP/IP) Modbus Master (RTU Serial) IEC 61850 Client (Optional) Standard SCADA Protocols IEC 60870-5-101 Slave (Serial) IEC 60870-5-104 Slave (TCP/IP) DNP 3.0 Slave (Serial and TCP/IP) IEC 61850 Server (Optional)

Standard Time Synchronization Protocols IRIG-B (BNC Connector Amplitude Modulated) Simple Network Time Protocol SCADA Protocol Based (IEC 101 / 104, DNP 3.0 Slaves). A wide range of communication media is supported with options such as: Leased line modem Dial-up PSTN modem CDMA/GPRS/GSM modules Fiber optic interface Interface for connection to PLC s radios, satellite, etc. Reliability Since the Remote Terminal Unit is the component of a SCADA/control system exposed to the most severe environmental conditions, reliability has been a key consideration throughout the development of ER1000. The unit is self-monitoring and in the unlikely event of a malfunction, this is reported to the master station at the first possible opportunity. Modular architecture for performance and flexibility The ER1000 has a modular design of both hardware and software. It can be equipped with input & output modules and power supply circuitry to match the specific requirements of each application. RTU CAPACITY Single rack supporting up to 208 I/O s. Multiple rack expansion supported over Ethernet. Up to Five racks can be stacked for better performance supporting 1040 I/O s. Up to 16 IEDs on Legacy RS485 bus for optimum performance. 1000 SOE record storage is supported in chronological order. +/- 1 msec I/O scanning resolution and time stamping. Easy Commissioning and Maintenance Tools ER1000 is as easy to use, as it is flexible. Installation is quick and uncomplicated also commissioning and testing is likewise simple. Parameter setting and testing The software used for parameter setting / configuration of the ER1000 is based on easy to understand menus and features extensive help manual. Protocol permitting, parameterization can also be done by down loading files from the central station (LAN / WAN). The tools make it possible to test the RTU locally / remotely (Ethernet based Config Tool) to diagnose malfunctions, confirm the configuration or check process connections.

Maintenance The ruggedness and reliability of the ER1000 make it maintenance free and requires no further attention once installed. ENVIRONMENTAL COMPLIANCE ER 1000 has been designed to meet the requirements for environmental conditions and performance of Remote terminal Unit and is type tested to the following standards IEC-60810-2-1 LEVEL 3 DAMPED OSCILLATORY MAGNETIC FIELD POWER FREQUENCY MAGNETIC FIELD POWER FRFQUENCY WITHSTAND TEST PULSE MAGENTIC FILELD 1.2/50 IMPULSE VOLTAGE TEST INSULATION RESISTANCE CLOD TEST DRY HEAT TEST DAMP HEAT TEST HIGH VOLTAGE TEST IEC-60255-5 IEC-61000-4-9 IEC-60255-5 IEC-60068-2-1 IEC-60068-2-2 IEC-60068-2-3 MFG SPEC LEVEL 3-4 LEVEL 4 LEVEL 3 LEVEL 3 LEVEL 3 2 KV FOR 1 MIN LEVEL 5 2 KV >100M0hm 0 0-10 &-25 C FOR 2 HRS 0 +55 C FOR 72 HRS AND + 0 70 C FOR 2 HRS 0 95 % RH @40 C FOR 96 HRS 300VAC

Guaranteed Technical Particulars

Ordering Code: FACT/ER1000/05-11/REV.2 " Easunreyrolle- ERL, the ERL Logo and any alternative version thereof are registered trademarks and service marks of Easun Reyrolle".