EnviroPro Configuration

Similar documents
5TM Sensor 2365 NE Hopkins Ct / Pullman, WA USA Volumetric Water Content and Temperature

ES-2. Electrical Conductivity & Temperature Sensor. Operator s Manual. METER Group, Inc. USA

RIC A. engineering. Specialist in remapping engine Management

User Manual SDI-12 Soil Moisture

Probe Interface Manual Version 1.1 (For firmware revision or above)

GS2 Greenhouse Sensor 2365 NE Hopkins Ct / Pullman, WA USA Volumetric Water Content and Temperature

UTelligent Management System UMS UMS-SH-A1 UMS-SH-B1. Quick Start Guide V1.4.0

SDI-12 Interface Cable. April 10, Built for:

Features. Target Applications. V1.6 TBS07 RS485 to SDI-12 Converter

Matric Potential Sensor 2 & NE Hopkins Ct / Pullman, WA USA Water Potential and Temperature

SDI-12 Interface Cable. August 1, Built for:

Updating Reader Firmware

VP-4 Sensor 2365 NE Hopkins Ct / Pullman, WA USA Vapor Pressure, Humidity, Temperature, and Atmospheric Pressure

ES-2. Electrical Conductivity & Temperature Sensor. Operator s Manual

Esensors. Websensor User Guide. Save trees. Print only when necessary

Instruction Manual. Power Meter PM01. AC line voltage monitor. Version 2.0

PIM Presco Interface Module

TBSMP02 Soil Moisture Probe Quick Reference Guide V1.0.doc V1.0. TBSMP02 Quick Reference Guide

B-Speech MiniPad User Manual. User Manual For Nokia Page 1 of 23

C-Bus Pascal Automation Controller

Instruction Manual. Replacing 2G GSM/GPRS Modem with GSM/3G MODEM CARD Model: DP-OPT-CARD-3G. Supplied by:

The watchdog is connected to the internal USB header and reset switch header on the majority of motherboards.

Unique Micro Design. Advanced Thinking Products. Model 164 Quad Coupler User Manual

Fetch Power Line Adapter User Guide. Stream Fetch through your home with Power Line Adapters

Pebble Manual. Please read these instructions before you begin installation to insure you have everything ready.

Features. Target Applications V1.6 JSMP01 SOIL MOISTURE PROBE MANUAL

PENTAIR ENVIRONMENTAL SYSTEMS

SMM Series - LTE / 3G Modem SMM-400. Firmware Release Notes

LD-RTD / LD-TC Temperature Controller

Select. Volume. Source

SDI-12 and the Decagon GS3 Soil Moisture Probe

CTD+DG Drain Gauge 2365 NE Hopkins Ct / Pullman, WA USA Water Depth, Electrical Conductivity, and Temperature

SLUG DATA-LOGGER MANUAL. YieldPoint Inc. JULY 2009

C-Bus Network Analyser Operating Instructions 5100NA

August International Ltd United Kingdom Telephone: +44 (0)

GV-Card Reader. User s Manual

JetI/O 6500 Demo Box

YSI EXO Series Multi-Parameter Water Quality Sondes

THUNDERBIRD INSTRUCTIONS HAND HELD ELECTRONIC TAG READER MODEL PR20

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

Local Stereo Input Module 3105LSIM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

AquaController Apex Probe Module 2

Copyright 2018 Xi an NovaStar Tech Co., Ltd. All Rights Reserved. No part of this document may be copied, reproduced, extracted or transmitted in any

Getting Familiar with Your FuzzyScan

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

Seanet System Serial Barometer Interface. Supplement

Neets Control QueBec P/N#: P/N#: User Manual

QHSE Integrated Solutions Customer Service System Manual

Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM)

HyQuest Solutions Pty Ltd. INSTRUCTION MANUAL FCD_App (TBRG FIELD CALIBRATION APPLICATION)

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VS-801USB 8x1 USB Switcher. P/N: Rev 3

Instruction Manual. HVAC Monitor Model EM32-F. Wi-Fi Websensor. Version 6.0

SKM 04. User Manual. 4-Port Keyboard, Mouse and Audio Switch with USB 2.0 Sharing

ARABLE BRIDGE QUICK START GUIDE

CONGRATULATIONS ON THE PURCHASE OF YOUR THUNDER BATTERY MONITOR

FA-2448 SIX POSITION Filter Wheel

Operation Manual for USB Autoscope Lite. Contents. USB Autoscope Lite Operation Manual

Translink Controller Installation Manual V1.0

SpecWare 9 Pro and Basic Software Quick Start Guide

User manual CCV Mini (Android)

DS-2 Sonic Anemometer 2365 NE Hopkins Ct / Pullman, WA USA Wind Speed, Direction, and Gusts

OPERATING MANUAL. WINDOWS Temperature Controller. Digi -Sense

Solar Panel Kit 40W. Model Number ARS INSTRUCTION MANUAL

HDRF BRIDGE. v User Guide

User Guide Set up your new ACN nbn Broadband service

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Mondo TC. Quick Reference & Setup Guide

USER MANUAL. VS-21HDCP-IR 2x1 DVI Switcher MODEL: P/N: Rev 5

WIRELESS WI-FI SPEAKER

Home Control Gateway Troubleshooting

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

MILAN VORTEX WIRELESS REPEATER USER MANUAL

product manual H-4114.MCU EDG Calibration Module

MLC. Semi Metal USB. Generation 5 / 5L HERCULES-PB Series. Product Specification MLC. Semi Metal USB Flash Disk Generation 5/5L

Biometric finger print entry system.

Revision: 0.30 June Intel Server Board S2600CP4 UEFI Development Kit Firmware Installation Guide

USB Gaming Keyboard. What your 1 year warranty means

Using a HP02 with the Eagle Batching System

GETTING CONNECTED Installation instructions for your NBN Modem Sagemcom 5356

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

User Manual ADAM-6100EI Series. EtherNet/IP I/O Modules

USB-to-I2C. Professional Hardware User s Manual.

DPM-3221 Digital DC Power Meter with data logging capability.

SMD Series Integrated Stepper Driver and Motor Revision 1.3

Model R5H-RS PC CONFIGURATOR (model: R5HRSCFG)

Firmware/Bootloader Update Manual

V1.0 TBSST02 SDI-12 SOIL TEMPERATURE SENSOR

CONTROLLER (Dimensions are approximate) CTS HAND HELD II

3G/4G Wireless N150 Router m2

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM-1.0 Version /8/2011 USER MANUAL

MTX-D Ethanol Content and Fuel Temperature Gauge User Manual

Revision: 0.30 June Intel Server Board S1200RP UEFI Development Kit Firmware Installation Guide

Model B3HU. PC CONFIGURATOR Model: B3HUCFG. Users Manual

Quick Start. MyAir4 User Manual. This section will give you a brief description about each of the buttons found on the home screen.

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VS-401USB 4x1 USB Switcher. P/N: Rev 1

Microsoft Pocket PC 2003 Windows Mobile 5.0 Phone Edition

AquiStar CT2X (SDI-12 & Modbus )

Taurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2

Taurus Series Multimedia Players XI'AN NOVASTAR TECH CO.,LTD. Common Problems & Remedies Document Version: V1.4.0 Document Number: NS

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

Transcription:

MANUAL Version 1.13 1. Notices...2 2. Introduction...3 3. Equipment Required...3 4. Terminal Emulator...4 5. Terminal Emulator Settings...4 6. Connecting the EPCU to a PC or Laptop...5 7. Required USB Drivers...5 8. Connecting the EPCU to the EnviroPro Soil Moisture Probe...5 9. EnviroPro Wiring...5 10. Using the Terminal Emulator...6 11. EPCU Firmware Version...6 12. Probe ID...7 13. Probe ID Number Breakdown...7 14. Changing the Probe Address...8 15. Probe Measurements...9 16. Upgrade the EnviroPro with EC...10 17. Testing Upgraded EnviroPro...12 18. Explore SDI-12 Line...13 19. Advanced Options...14 20. Transparent Mode...14 21. Examples of SDI-12 Commands...15 22. Advanced Options 2-4...17

notices Copyright All rights reserved. No part of this document may be reproduced, transcribed, translated into any language or transmitted in any form electronic or mechanical for any purpose whatsoever without the prior written consent of Enetelechy Pty Ltd. All intellectual and property rights remain with Entelechy Pty. Ltd. All information presented is subject to change without notice. EnviroPro is a registered trademark of Entelechy Pty. Ltd. 2016 Entelechy Pty. Ltd. Contact Warranty Entelechy Pty Ltd offers a 12 month, return-to-factory warranty on this product. The warranty applies to hardware and firmware defects only. The warranty does not cover acts of misuse by the user or third parties, including misuse arising from failure to install or operate a system or its components in accordance with relevant system documentation, or failure to seek advice from Entelechy regarding correct installation or operation of a system or its components. This product is guaranteed against faulty workmanship or defective material for a period of 1 (one) year from date of purchase. Entelechy Pty Ltd ACN 611 963136 ABN 59 611 963 136 4 /8 Aristotle Close Golden Grove, South Australia 5125 Phone: +61 8 8251 7559 Facsimile: + 61 8 8251 5519 Internet: Email: sales@enviroprosoilprobes.com 2. 2.

manual 2. Introduction Thank you for purchasing an EnviroPro Unit (EPCU) from Entelechy. This guide tells you how to use and operate your EPCU correctly. 3. Equipment Required 1 x EnviroPro Unit V1.13 (1) 1 x USB cable (2) 1 x 3.5mm stereo plug to 3 x Alligator cable assembly (3) 1 x EnviroPro Soil Moisture Probe 1 x PC / Laptop running a Terminal Emulator Figure 1 Figure 2 Figure 3 3.

4. Terminal Emulator The EPCU requires a Terminal Emulator to be installed on a computer or laptop. There are many Terminal Emulators available from various vendors. For example: https://sites.google.com/site/terminalbpp/ http://ttssh2.osdn.jp/index.html.en http://www.commfront.com/commfront-downloads.htm 5. Terminal Emulator Settings Open the Terminal Emulator. (The appearance of the Terminal screen will vary depending on the software being used). Check the settings of the Terminal Emulator. COM PORT : Ensure correct port is selected BUAD RATE : 9600 DATA BITS : 8 STOP BITS : 1 HANDSHAKING : None DATA FORMAT : ASCII NOTE: Some terminal emulators require the Add line feed to carriage return enabled (CR+LF) in order to display commands sent and responses received correctly. 4.

6. Connecting the EPCU to a PC or Laptop Connect the EPCU to the computer using the USB cable supplied to any available USB port. The EPCU will initialise a self-test after which the Green Idle LED will flash slowly indicating the EPCU is now ready. 7. Required USB Drivers A USB driver may be required if using the EPCU first time. Please allow the computer to install automatically or download and install the USB driver manually. Drivers are can be downloaded at: https://www.silabs.com/products/mcu/pages/usbtouartbridgevcpdrivers.aspx 8. Connecting the EPCU to the EnviroPro Soil Moisture Probe Ensure the 3.5mm stereo plug is fully inserted into the EPCU 3.5mm socket. Connect the 3 x alligator clips matching each colour of each alligator clips to the coloured wires on the EnviroPro soil probe. NOTE: DO NOT connect or disconnect the probe from the EPCU while the RED Powered LED or ORANGE Active LEDs are on. Only connect and disconnect when the GREEN Idle LED is flashing slowly 9. EnviroPro Wiring Function PWR [+6 V to +15 V] DATA GND [0 V] Not used EnviroPro Wiring Red Blue Black Yellow 5.

10. Using the Terminal Emulator Press Connect on the Emulator Terminal. 11. EPCU Firmware version NOTE: Send commands (shown in red) Responses (shown in blue) To check the EPCU firmware version type? (without quotation marks) The following will be returned showing the EPCU firmware version and firmware date. EnviroPro CONFIG V 1.13, (2015.08.31) NOTE: If you are using an earlier version please return to your supplier or Entelechy Pty. Ltd. for a free upgrade. This manual is written for EPCU V1.13 only. 6.

12. Probe ID Press the space bar. The following response will be received. CHECKING PROBE, PLEASE WAIT SDI-12 MODE, A=1, ID=113EP100GL-08 01151108151545 Options: 0=CHANGE_ADDRESS 1=MEASURE 2=UPGRADE 3=EXPLORE_SDI-12_LINE 4=ADVANCED 13. Probe ID Number Breakdown A= address of probe ID= Type of probe connected and unique identification serial number ID= 013 EP100 G L -08 01151108151545 Series C D E F G Depth 04 = 40cm 08 = 80cm 12 = 120cm 16 = 160cm Serial No. SDI Version 012 = Version 12 013 = Version 13 Version = Moisture, Temperature & Salinity L = Moisture, Temperature 7.

14. Changing the probe address To change the address of the EnviroPro Probe From the main menu select 0 and enter the required address number. For example 1 Options: 0=CHANGE_ADDRESS 1=MEASURE 2=UPGRADE 3=EXPLORE_SDI-12_LINE 4=ADVANCED CHANGE ADDRESS ADDRESS=1 CHECKING PROBE PLEASE WAIT SDI-12 MODE, A=1, ID=113EP100GL-08 01151108151545 A=1 showing the probe address changed to 1 8.

15. Probe measurements To take a measurement from the main menu select 1 Options: 0=CHANGE_ADDRESS 1=MEASURE 2=UPGRADE 3=EXPLORE_SDI-12_LINE 4=ADVANCED The probe will output moisture, salinity* and temperature in C and F measurements from each sensor. *Salinity readings will be 0 for lite version (NO EC) 1C! moisture 01: 001.62 %VWC 02: 000.95 %VWC 03: 000.79 %VWC 04: 000.41 %VWC 1C1! salinity 01: 00.000 ds/m ECe 02: 00.000 ds/m ECe 03: 00.000 ds/m ECe 04: 00.000 ds/m ECe 1C2! temperature 01: 025.81 degc 02: 025.84 degc 03: 025.70 degc 04: 025.96 degc 1C5! temperature 01: 078.19 degf 02: 078.26 degf 03: 077.99 degf 04: 078.46 degf Example of 4-sensor probe reply 9.

16. Upgrade the EnviroPro with EC NOTE: An EC upgrade key will be required. Please obtain the ID number from each probe and contact your supplier to purchase an EC upgrade key. Each probe will require its own unique EC upgrade key. Once the ID number has been provided to Entelechy an EC upgrade key that is unique to that probe will be supplied. For example: 0801151108151545 ; 16 digit probe ID KEY 64429 ; EC key for upgrade via EPCU XKEY FBADE841 ; EC Xkey for remote upgrade* (*for probes version G or later) To upgrade the probe with EC (salinity) ensure the EPCU and probe are connected as described at the beginning of this manual. From the main menu select option 2 and enter the EC key supplied, for example 64429 Options: 0=CHANGE_ADDRESS 1=MEASURE 2=UPGRADE 3=EXPLORE_SDI-12_LINE 4=ADVANCED Serial No.0801151108151545 KEY: 64429 UPGRADE 0801151108151545 PLEASE WAIT EP100G-08 01151108151545-1 CHECKING PROBE, PLEASE WAIT SDI-12 MODE, A=1, ID=113EP100G-08 01151108151545 CHECKING PROBE PLEASE WAIT SDI-12 MODE, A=1, ID=113EP100G-08 01151108151545 SUCCESS The new ID is EP100G-08 confirms the probe is now a G = Full EC version (GL = Lite (no EC) version 10.

Remote Upgrade - Version G Only The following SDI-12 extended commands enable remote upgrade of the EnviroPro sensor to measure EC using telemetry/loggers that support transparent mode. For example: ID=013EP100GL-0801151108151545 XKEY FBADE841 ; probe ID ; EC Xkey for remote upgrade (supplied by Entelechy) In transparent mode send the extended command 0XUFBADE841! via the logger or telemetry system. Where 0 is the probe address followed by the command XU and then the 8 digit Xkey. (Note the upgrade Xkey is not case sensitive). Once transmitted the probe will then be upgraded to a full EC version and will return the following message: 01 PASS The new ID will display 013EP100G-0801151108151545 confirming the probe has been successfully upgraded with EC measurements enables (G = Full EC version). If the message 00 FAIL is received the probe ID will still show GL meaning the probe has not been upgraded with EC. 11.

17. Testing upgraded EnviroPro To test the EC upgrade hold the probe with one hand or place the probe into a saline solution. While holding the probe with one hand or while in a saline solution from the main menu select 1 to measure. Options: 0=CHANGE_ADDRESS 1=MEASURE 2=UPGRADE 3=EXPLORE_SDI-12_LINE 4=ADVANCED In the example below the probe was being held by hand at the very end where the 8th sensor is located (80cm depth). Note the value at sensor 08 which shows some salinity was measured off the hand 1C1! salinity 01: 00.000 ds/m ECe 02: 00.000 ds/m ECe 03: 00.000 ds/m ECe 04: 00.000 ds/m ECe 05: 00.000 ds/m ECe 06: 00.000 ds/m ECe 07: 00.000 ds/m ECe 08: 00.732 ds/m ECe 12.

18. Explore SDI-12 Line To explore and list all SDI-12 units connected to the SDI-12 data line select option 3 from the main menu. Options: 0=CHANGE_ADDRESS 1=MEASURE 2=UPGRADE 3=EXPLORE_SDI-12_LINE 4=ADVANCED The following example found one EnviroPro soil probe at address 1 0I! 1I! 113EP100G-08 01151108151545 2I! 3I! 4I! 5I! 6I! 7I! 8I! 9I! AI! BI! CI! DI! EI! FI! GI! HI! II! JI! KI! LI! MI! NI! OI! PI! QI! RI! SI! TI! UI! VI! WI! XI! YI! ZI! ai! bi! ci! di! ei! fi! gi! hi! ii! ji! ki! li! mi! ni! oi! pi! qi! ri! si! ti! ui! vi! wi! xi! yi! zi! CHECKING PROBE, PLEASE WAIT SDI-12 MODE, A=1, ID=113EP100G-08 01151108151545 13.

19. Advanced Options From the main menu select option 4 Options: 0=CHANGE_ADDRESS 1=MEASURE 2=UPGRADE 3=EXPLORE_SDI-12_LINE 4=ADVANCED A new menu called ADVANCED Options will be displayed ADVANCED Options: 0=TRANSPARENT_MODE 1=SDI-12_or_CMOS 2=NINE_SENSORS 3=DEMO_SET 4=VERSION_D_ FIX 20. Transparent Mode In transparent mode any valid SDI-12 command can be entered via a keyboard. For more information regarding the SDI-12 protocol and standard please visit: http://www.sdi-12.org/current%20specification/sdi-12_version1_3%20january%2028,%202016.pdf Select option 4 from the main menu Options: 0=CHANGE_ADDRESS 1=MEASURE 2=UPGRADE 3=EXPLORE_SDI-12_LINE 4=ADVANCED wi! xi! yi! zi! Select 0 for transparent mode or when finished press Q to exit ADVANCED Options: 0=TRANSPARENT_MODE 1=SDI-12_or_CMOS 2=NINE_SENSORS 3=DEMO_ SET 4=VERSION_D_FIX TRANSPARENT_MODE, press Q to exit 14.

21. Examples of SDI-12 commands Below are examples of SDI-12 commands that can be sent while in transparent mode. NOTE: Send commands (shown in red) Responses (shown in blue)?! 1 ; query probe address ; probe response (Address = 1) 1I! 113EP100G-08 01151108151545 ; request probe ID ; probe response 1A0! 0 ; change probe address from 1 to 0 ; probe response (Address = 0) 0C! 000208 0D0! 0+001.84+001.52+001.58+001.61+000.96+000.04+000.00+000.05 ; measure moisture with salinity compensation ; time taken 0002 seconds, 08 sensors measured ; read probe data ; eight moisture measurements as a percentage % of VWC returned 0C1! 000208 0D0! 0+00.000+00.000+00.000+00.000+00.000+00.000+00.000+00.000 ; measure salinity ; time taken 0002 seconds, 08 sensors measured ; read probe data ; eight salinity measurements in ECe, ds/m returned 15.

21. Examples of SDI-12 commands (cont.) Below are examples of SDI-12 commands that can be sent while in transparent mode. NOTE: Send commands (shown in red) Responses (shown in blue) 0C2! 000208 0D0! 0+028.06+027.97+027.90+028.08+029.05+028.77+028.05+027.02 ; measure temperature in C ; time taken 0002 seconds, 08 sensors measured ; read probe data ; eight temperature measurements in C returned 0C3! 000208 0D0! 0+001.80+001.56+001.62+001.58+000.95+000.02+000.00+000.03 ; measure moisture without salinity compensation ; time taken 0002 seconds, 08 sensors measured ; read probe data ; eight moisture measurements as a percentage % of VWC without salinity compensation returned 0C4! ; reserved (factory use only) 0C5! 000208 0D0! 0+082.48+082.30+082.22+082.49+084.26+083.61+082.30+080.39 ; measure temperature in F ; time taken 0002 seconds, 08 sensors measured ; read probe data ; eight temperature measurements in F returned * Older M commands are also supported however, if number of enabled sensors exceeds nine (9) than C commands are recommended. **C6 to C9 commands reserved for future features. 16.

22. Advanced Options 2-4 ADVANCED Options: 0=TRANSPARENT_MODE 1=SDI-12_or_CMOS 2=NINE_SENSORS 3=DEMO_SET 4=VERSION_D_FIX NOTE: There are a number of additional functions in the Advanced menu (Options 1 to 4) It is recommended these only be used if advised by Entelechy to do so. 17.