WiFi data logger system

Similar documents
WiFi data logger system

All measurement data. Always available. On any device. The WiFi data logger system testo Saveris 2. Analysis & Reports. Graphical presentation

WiFi data logger system

Measurement data monitoring system

Measurement data monitoring system

Measurement data monitoring system

F %RH. %rf CO 2. g/m 3. inch H₂O. hpa. Measure. Record. Monitor. Choose the right data loggers for your application now.

Measurement data monitoring system

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

Next Generation! We measure it. With the professional Testo data loggers, a new age begins for you. Logger series testo 174. Logger series testo 175

Next Generation! Committing to the future. With the professional Testo data loggers, a new age begins for you. Logger series testo 174

Measurement data monitoring system

We measure it. Everything under control: With testo Saveris TM, measurement data are under control everywhere.

VAC analysis measuring instrument

Measurement data monitoring system testo Saveris.

Measurement data monitoring system testo Saveris.

Miles Ahead of the Competition!

Infrared temperature measuring instrument

Measurement data monitoring system testo Saveris.

We measure it. Automated and uninterrupted measurement data recording. Flexible system set-up with wireless or Ethernet probes in many probe versions

Measure, document, issue alarms. Automated with testo Saveris. Committing to the future

Measurement Solutions for Climate Applications in Industry

Differential pressure measuring instrument

Differential pressure measuring instrument

Infrared temperature measuring instrument

Infrared temperature measuring instrument

Differential pressure measuring instrument

Infrared Temperature Measuring Instrument

Differential pressure measuring instrument

Differential pressure

testo 160 Instruction manual

testo 735 Compact Pro Series NEW! The working standard for temperature measurements

Humidity transmitter for critical climate applications

testostor 171 Instruction manual

Differential pressure measuring instrument

EBI 25 Wireless Data Logger System

DATA LOGGERS Reliable solutions for monitoring your processes

Log, Save, Print and Analyse Data On-Site Quickly and Efficiently

x testo 400 The reference measuring instrument for A/C and ventilation systems Additional information at

testo 175 Instruction manual

PRODUCT GUIDE. Your Data, Anytime, Anywhere.

Measuring Instruments for Humidity

The industrial humidity transmitter

The flue gas analyzer with Longlife sensors and integrated draught/gas zeroing

testo 175 Data loggers Instruction manual

Remote Temperature Monitoring

TR-7 Series. Network / USB Data Loggers TR-7wf/nw Series Infrared / USB Data Loggers. TR-7Ui Series

testo LL Flue gas analysis with increased convenience and reliabilty

ebro has expanded its wide range of loggers in the food sector even further: ebro Data Logger Family EBI 20

User s Guide. OM-EL-WiFi-TH. Shop online at omega.com. OM-EL-WiFi-TP-PLUS. Probe Data Logging Sensor

The industrial humidity transmitter

testo Probe series testo 661x The industrial humidity transmitter We measure it. SPECIFICATIONS testo Probe series testo 661x

EL-WiFi-TH -

User s Guide. OM-EL-WiFi-TH. Shop online at omega.com. OM-EL-WiFi-T-PLUS. Data Logging Sensor

recording Remote Temperature Monitoring remote temperature monitoring ThermaData loggers, WiFi or Bluetooth applications for remote monitoring

Multi-Function Measuring Instruments

testo 176 Data loggers

Precision digital measuring device PHYSICS 51

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

testo 176 Datenlogger testo 176 Data loggers testo 176 Enregistreur de données Bedienungsanleitung Instruction manual Mode d'emploi

Phone: Fax: For calls outside the US please call:

PHYSICS Digital Measuring Devices

Temperature Data Logger EBI 100

T5a, T5b & T5c Temperature Tags

Committing to the future. Measurement Solutions for Production, Quality Control and Maintenance

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

RMS Mini Wireless Data Logger

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

RCW-400A USER GUIDE. Version 1.1

Data Logging Solutions from Lascar Electronics

Testo refrigeration measurement technology: Intuitive, efficient, reliable.

DTB-1. Digital Thermometer Battery Powered

REFERENCE MEASURING INSTRUMENT

Hand-Held Thermometer Model CTH 6200

Supplied with. Calibration certificate. HD 200 Hygrometer

TR-7wf Series. and Infrared / USB Data Loggers TR-7Ui Series

RMS WIRELESS MINI LOGGER

3. Analytical measurement and testing Thermometers/Temperature logger-timing/timers

Quick intervention before it is too late Automatic documentation

Committing to the future. Measuring Instruments for Temperature

Input for universal probe* Inputs for thermocouple probes

Measuring Instruments for Humidity

DTE. Digital Thermometer. battery powered. measuring. monitoring. analysing. O O Universal Pt100 or thermocouple sensors Battery powered

TEMPERATURE HUMIDITY PRESSURE ALL FOR YOUR WIRELESS MEASUREMENT AND DATA COLLECTION FROM ONE PROVIDER!

PI 500 Hand-held instrument for industry

DP 500/DP 510 Portable dew point meters with data logger

EL-WiFi-TH WiFi Temperature & Humidity Data Logging Sensor

USB-500/600 Series Low-Cost Data Loggers and Accessories

testo Probe series testo 661x The industrial humidity transmitter Committing to the future

ProcessCalibrator Model CPH6000

Dual channel temperature logger with display Instruction Manual

RMS Mini Wireless Data Logger

Data-Loggers DATA-LOGGERS. for recording temperature or humidity. what are data-loggers? applications for data-loggers

KISTOCK DATALOGGER KT 320 / KTT 320

MMT330 Series Moisture and Temperature Transmitters for Oil

Insertion RTD temperature probe

Wireless Open / Closed Sensor

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.

Temperature logger with internal sensor Instruction manual

Precision digital gas density indicator Model GDI-100-D

Transcription:

Data sheet Saveris 2 WiFi data logger system Saveris 2 temperature, humidity and CO 2 monitoring re-thought C Data transfer by wireless LAN All measurement data always available, anywhere, on any instrument %RH CO₂ Alarms when limit values are violated With Saveris 2 App for easier configuration, push alarms and WiFi range analysis Cost-free online data store (Testo Cloud) mbar Saveris 2 App for free download The Saveris 2 WiFi data logger system is the modern solution for monitoring temperature and humidity values as well as CO 2 concentration in storerooms and work rooms. Installing the system is child's play, and can be carried out either via a browser, or with the Saveris 2 App. The WiFi data loggers reliably record temperature, humidity and CO₂ concentration at adjustable intervals and transmit the measurement values directly by wireless LAN to the Testo Cloud. The readings stored can be analyzed at any time, anywhere, using an internet-enabled smartphone, tablet or PC. Limit value violations are immediately reported by e-mail, optionally by SMS or via the Saveris 2 App as a push notification. This allows critical processes to be kept always under control, even if you are not on site. The long battery life additionally ensures that the Saveris 2 system needs to be serviced only rarely. www..com

Saveris 2 Climate monitoring re-thought The data logger system Saveris 2 allows you full and easy control of ambient conditions at all times no matter where you are. %RH CO₂ mbar 21.5 41.5 715 1013 WiFi data loggers PC Smartphone C Tablet Local wireless LAN router Saveris 2 Cloud Our packages The Testo Cloud is the core operating element for setting up your Saveris 2 system. Here you can configure your WiFi data loggers, set limit value alarms and analyze your measurement data. You must first register at www.saveris.net to have access to the Testo Cloud. Depending on the desired range of functions, you have a choice between the free Basic and more extensive Advanced functionality for use of the Testo Cloud. In both packages, you have access to an API interface, in order to export measurement data to your systems. cycle Basic 15 min to 24 h Free Advanced 1 min to 24 h Communication cycle 15 min to 24 h Data storage Max. 3 months Max. 2 years Manual (.pdf/.csv) Manual (.pdf/.csv) Automatic (.pdf/.csv) Reports 1 min to 24 h For one measurement channel in each case For up to 10 measurement channels simultaneously Number of users per account 1 10 Number of WiFi data loggers per account Unlimited Unlimited Upper/lower alarm limits Upper/lower alarm limits Alarm delay Time control of alarms Notification of low battery Radio link interrupted Power supply interrupted Notification of low battery Radio link interrupted Power supply interrupted Data analysis Alarm options System notifications E-mail alarm SMS alarm Yes Yes No Including 25 SMS per logger and year Option of purchasing additional SMS packages 12-month licence Order no. 0526 0735 24-month licence Order no. 0526 0732 36-month licence Order no. 0526 0733

Saveris 2 Ordering data WiFi data loggers T1 H1 T1; WiFi data logger (wireless LAN) with display and internal NTC temperature sensor, incl. USB cable, wall bracket, batteries and calibration certificate H1; WiFi data logger (wireless LAN) with display for measuring temperature and relative humidity, internal capacitive sensor incl. USB cable, wall bracket, batteries and calibration certificate Order no. 0572 2031 Order no. 0572 2034 T2 H2 T2; WiFi data logger (wireless LAN) with display for measuring temperature, two connections for external NTC temperature probes or door contacts, incl. USB cable, wall bracket, batteries and calibration certificate H2; WiFi data logger (wireless LAN) with display for measuring temperature and relative humidity, connection for one external humidity probe, incl. USB cable, wall bracket, batteries Order no. 0572 2032 Order no. 0572 2035 T3 T3; WiFi data logger (wireless LAN) with display for measuring temperature, two connections for external TC temperature probes (Types K, T, J), incl. USB cable, wall bracket, batteries and calibration certificate 160 IAQ 160 IAQ WiFi air quality logger with display and integrated sensors for temperature, humidity, CO 2 and atmospheric pressure Order no. 0572 2033 Order no. 0572 2014 Saveris 2 - set for temperature monitoring in refrigerators T2; WiFi data logger (wireless LAN) with display for measuring the temperature, two connections for external NTC temperature probes or door contacts, incl. two ribbon-cable temperature probes, two temperature simulation flasks for filling with a temperature buffer suitable for each respective area of application, USB cable, wall bracket, batteries and calibration certificate Order no. 0572 2103 Please note that in order to use the WiFi data logger system Saveris 2, a WiFi data logger, registration in the Testo Cloud (www.saveris.net) and a wireless LAN-capable network are absolutely necessary.

Saveris 2 Technical data Temperature measurement T1 T2 T3 H1 H2 160 IAQ Sensor type NTC internal NTC TC Type K TC Type J TC type T NTC internal NTC range -30 to +50 C -50 to +150 C -195 to +1350 C -100 to +750 C -200 to +400 C -30 to +50 C range and accuracy correspond to probe 0 to +50 C Accuracy ±1 digit ±0.5 C ±0.3 C ±(0.5 + 0.5 % of m.v.) C ±0.5 C ±0.5 C Resolution 0.1 C 0.1 C Humidity measurement range 0 to 100 %RH 0 to 100 %RH Accuracy ±2 %RH range and accuracy correspond to probe ±2 %RH at +25 C and 20 to 80 %RH ±3 %RH at +25 C and <20 %RH and >80 %RH ±1% RH hysteresis ±1% RH / year drift Resolution 0.1 %RH CO₂ measurement range 0 to 5 000 ppm Accuracy ±(50 ppm + 3 % of m.v.) at +25 C Without external power supply: ±(100 ppm + 3 % of m.v.) at +25 C Resolution 1 ppm Pressure measurement range 600 to 1100 mbar Accuracy ±3 mbar at +22 C Resolution 1 mbar Temperature/humidity measurement via external probes External probe connection External temperature probes External temperature probes External humidity/ temperature probe General technical data Operating temperature -30 to +50 C 0 to +50 C Storage temperature (without batteries) -40 to +70 C -20 to +50 C Protection class IP65 IP65 IP54 IP30 IP54 IP20 cycle Depends on the Cloud licence / Basic: 15 min to 24 h / Advanced: 1 min to 24 h Communication cycle Depends on the Cloud licence / Basic: 15 min to 24 h / Advanced: 1 min to 24 h Memory 10000 readings/channel 32,000 readings (sum of all channels) Standards / permits EN 12830 EN 12830 Battery life 12 months (typical value, depending on the wireless LAN infrastructure) at +25 C, 15 mins measurement rate and standard communication rate at -30 C, 15 mins measurement rate and standard communication rate with Energizer batteries 0515 0572 12 months Voltage supply Dimensions 4 x AA AlMn Mignon batteries; mains unit optional; for temperatures under -10 C please use Energizer batteries 0515 0572 95 x 75 x 30.5 mm 115 x 82 x 31 mm 95 x 75 x 30.5 mm 4 x AA alkali manganese batteries 1.5 V, alternatively mains unit via USB connection 117 x 82 x 32 mm Weight (including batteries) 240 g 250 g 240 g 269 g Door contact No Optional No Communication Signal transmission: wireless; frequency band: 2.4 GHz; supported wireless LAN standards: IEEE 802.11 b/g/n and IEEE 802.1X WiFi (wireless LAN) Possible encryption methods: without encryption, WEP, WPA, WPA2, WPA2 Enterprise The data loggers communicate via the standard protocol MQTT and are SNTP time synchronization-capable.

Saveris 2 Saveris 2 App With the App for ios and Android, you now operate the wireless LAN data logger system Saveris 2 even more easily and flexibly via your smartphone. More efficient commissioning*: Easy recognition and selection of the WiFi network Faster parallel commissioning of several loggers Easy network analysis*: Test the strength and range of your WiFi network Create and send status reports Reliable alarm functions: Push notifications of limit value violations Combinable with e-mail or SMS alarms * These functions are available only in the Android version of the Saveris 2 App. Ordering data for accessories Accessories Door contact for T2 WiFi data logger Mains unit for Saveris 2 WiFi data loggers Battery for WiFi probes (4 x AA alkali manganese Mignon batteries)) Batteries for operating WiFi data loggers Saveris 2 below -10 C (4 x Energizer L91 Photo-Lithium) Magnetic adapter for Saveris 2 wall bracket, for attachment to magnetic surfaces Wall bracket for 160 IAQ Deco-cover for 160 IAQ ISO temperature calibration certificate, temperature probe; calibration points -18 C, 0 C, +40 C; per channel/instrument DAkkS temperature calibration certificate; temperature probe; calibration points -18 C, 0 C, +40 C; per channel/instrument ISO humidity calibration certificate; calibration points 11.3 %RH and 75.3 %RH at +25 C/ +77 F; per channel/instrument DAkks humidity calibration certificate; humidity probe; calibration points 11.3 %RH and 75.3 %RH at +25 C; per channel/instrument ISO calibration certificate CO2, calibration points 0; 1000; 5000 ppm Order no. 0572 2152 0572 2020 0515 0414 0515 0572 0554 2001 0554 2015 0554 2012 0520 0153 0520 0262 0520 0076 0520 0246 0520 0033

Saveris 2 Temperature probes for T2 Probe type Dimensions probe shaft/probe shaft tip range Accuracy t 99 Order no. Stump probe, IP 54 35 mm -20 to +70 C ±0.2 C (-20 to +40 C) ±0.4 C (+40.1 to +70 C) 15 s 0628 7510 Ø 3 mm Stationary probe with aluminium sleeve, IP 65, fixed cable 2.4 m 40 mm -30 to +90 C ±0.2 C (0 to +70 C) ±0.5 C (remaining meas. range) 190 s 0628 7503 Ø 6 mm Accurate immersion/penetration probe, cable length 6 m, IP 67, fixed cable 40 mm Ø 3 mm Ø 3 mm -35 to +80 C ±0.2 C (-25 to +74.9 C) ±0.4 C (remaining meas. range) 5 s 0610 1725 Surface probe fixed cable, 2 m 40 mm -50 to +80 C ±0.2 C (0 to +70 C) 150 s 0628 7516 8 x 8 mm Penetration probe NTC with ribbon cable, cable length 2 m, IP 54, fixed cable 60 mm 30 mm Ø 5 mm Ø mm -40 to +125 C ±0.5 % of m.v. +100 to +125 C) ±0.2 C (-25 to +80 C) ±0.4 C (remaining meas. range) 8 s 0572 1001 Pipe wrap probe with Velcro tape for pipe diameters up to max. 75 mm, Tmax. +75 C, fixed cable 300 mm -50 to +70 C ±0.2 C (-25 to +70 C) ±0.4 C (-50 to -25.1 C) 60 s 0613 4611 External temperature probe 12 mm, plug-in, without cable 105 mm Ø 12 mm -30 to +50 C ±0.2 C (-30 to +50 C) 0572 2153 Ø 20 mm More probes at www..com!

Saveris 2 Temperature probes for T3 Probe type Dimensions probe shaft/probe shaft tip range Accuracy t 99 Order no. Stationary probe with stainless steel sheath, TC Type K 40 mm Ø 6 mm -50 to +205 C Class 2* 20 s 0628 7533 Connection: Fixed cable 1.9 m Penetration probe TC with ribbon cable, Type K, cable length 2 m, IP 54 60 mm Ø 5 mm 30 mm Ø mm -40 to +220 C Class 1 7 s 0572 9001 Magnetic probe, adhesive power approx. 10 N, with magnets, for higher temperatures, for measurements on metal surfaces, TC Type K Pipe clamp probe for pipe diameters 5 to 65 mm, with replaceable measuring head, measuring range short-term up to +280 C, TC Type K Pipe wrap probe with Velcro tape, for measuring temperatures on pipes with diameters up to max. 120 mm, Tmax +120 C, TC Type K Flexible, low-mass immersion measurement tip, ideal for measurements in small volumes such as Petri dishes or for surface measurements (e.g. fixed with adhesive tape), TC Type K, 2 m, FEP-insulated thermal wire, temperature-proof to 200 C, oval cable with dimensions: 2.2 mm x 1.4 mm 75 mm Ø 21 mm Connection: Fixed cable 1.6 m Connection: Fixed cable 1.2 m 395 mm Connection: Fixed cable 1.5 m Ø 0.25 mm 500 mm 20 mm -50 to +400 C -60 to +130 C -50 to +120 C -200 to +1000 C Class 2* 0602 4892 Class 2* 5 s 0602 4592 Class 1* 90 s 0628 0020 Class 1* 1 s 0602 0493 * Acc. to norm 60584-2, the accuracy of Class 1 refers to -40 to +1000 C (Type K), Class 2 to -40 to +1200 C (Type K), Class 3 to -200 to +40 C (Type K). Humidity/temperature probes for H2 Probe type Dimensions Probe shaft/probe shaft tip range Accuracy Order no. Humidity/temperature probe 12 mm, fixed cable, cable length 1.3 m -30 to +70 C 0 to 100 %RH ± 0.3 C ±2 %RH at +25 C (2 to 98 %RH) ± 0.03%RH/K ± 1 digit 0572 2155 External humidity/temperature probe 12 mm, plug-in, without cable 105 mm Ø 12 mm -30 to +50 C 0 to 100 %RH ± 0.3 C ±2 %RH 0572 2154 Ø 20 mm More probes at www..com!

Saveris 2 Subject to change without notice. 1981 2014/msp/I/01.2018 www..com