SH RK 100S SH RK 200S

Similar documents
Electronic Submeter with Advanced WiFi Ethernet Capability

NEW MODERNSTE TECHNOLOGIE. Elektronische Messgeräte mit hoher WiFi Ethernet Leistungsfähigkeit. Führende Technologie in der Industrie

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

NEW Industry Leading Technology. Includes Modbus and DNP 3.0 A G G R E S S I V E T E C H N O L O G Y. High End Meter Performance

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

Industry Leading Performance From Simple to Sophisticated The Leader in Power Monitoring and Control

Industry Leading Performance From Simple to Sophisticated The Leader in Power Monitoring and Control

Industry Leading Performance From Simple to Sophisticated Highly Accurate Metering Technology

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

UW Purchase Specification Section

Nexus Cyber Secure Energy Panel Meter with Advanced Power Quality & Multiport Communication. Advanced Power Quality Analysis

Multilin EPM 6010 YEAR. GE Grid Solutions. Building Automation Power Meter with BacNET /IP Communications. Monitoring & Metering

CoPilot EXT. Electro Industries/GaugeTech. Installation & Operation Manual Revision PDA Based Software

UPGRADABLE FULLY FEATURED POWER & ENERGY METER

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET

Series 3000 Advanced kwh Meter Kits

UPGRADABLE FULLY FEATURED POWER & ENERGY METER

Power Xpert Branch Circuit Monitor

Electronic Submeter with WIFI Ethernet Capability and Datalogging. Installation & Operation Manual Revision 1.01

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

ACUREV 2000 Multi-Circuits Networked Multifunction Power Energy Meter

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Multifunction Transducer MT440

MIC-2 MKII, Multi-instrument DATA SHEET

EPM Multilin ADVANCED POWER QUALITY METER. High Performance Power Quality and Transient Recorder Meter KEY BENEFITS APPLICATIONS FEATURES

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

Multilin EPM High Performance Power Quality Analysis Socket Meter. Monitoring & Metering. Advanced Communications. Key Benefits.

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

Voltage Transducer UMT516 / MT516

Current Fault Signatures and Analysis Auto-calibrating metrology means the meter maintains its accuracy over temperature and time

Nexus 1262/1272. High Performance Utility Billing Meters with Communication and Advanced Power Quality. Highly Advanced Revenue Meter

Nexus 1262 /1272. Electro Industries/GaugeTech. Installation & Operation Manual Revision High Performance Socket Meter

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

EPM Multilin POWER QUALITY METER SERIES. High Performance Power Quality Analysis Device KEY BENEFITS APPLICATIONS FEATURES.

PSL. Power Quality & Energy Monitoring. PQube power quality & energy analyzer. Low-Cost, High-Precision

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

Nexus 1262/1272. High Performance Utility Billing Meters with Communication and Advanced Power Quality. Highly Advanced Revenue Meter

SECTION ELECTRIC METERING

EM QUICK START GUIDE. Quick Start Guide EM BG0504 REV.A2

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

USER MANUAL 2012 V1.1

MW/MVAR Transducer Specifications

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Nexus Advanced Performance Smart Power Meter. and Substation Data Acquisition Node. For Smart Grid and Substation Automation

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

FP-5000 Feeder Protection

WM20. Power analyzer for three-phase systems. Benefits. Description

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

MODULAR CIRCUIT MONITORING SYSTEM

Nexus Next Generation Power Meter for Critical Energy Circuits. Advanced Metering and Communication

EngyVolt RV12 and RV15

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter

Nexus Next Generation Power Quality Meter for Critical Energy Circuits. Advanced Metering and Communication

ACUREV Three-Phased DIN-Rail Multifunction Meter FEATURES

Revenue Grade General Specifications

Digital metering instruments and current transformers

Nexus 1262 / Electro Industries/GaugeTech. Installation & Operation Manual Version High Performance Socket and Switchboard Meters

Multilin EPM 9650 & 9450

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Energy Management Energy Transducer Type ET112

EM6400 series Multi-Function meters

PMC 530 Series Advanced Multifunction Meter

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Nexus Transient Recorder and Power Meter With Advanced Power Quality and Communication. Communication, I/O and User Interface

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems

Hot pluggable communication modules

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

SECTION ( ) LIGHTING CONTROL PANELBOARD

PowerLogic EM4000 series

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

CompuScope Ultra-fast waveform digitizer card for PCI bus. APPLICATIONS. We offer the widest range of

ABB NETWORK ANALYSER M2M. Quick set-up guide

DIN Rail Smart Meter for Single and Three Phase Electrical Systems

Series 3000 User Manual and Product Features

SECTION SWITCHBOARDS

FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY

1.2. All new meters will be one of the following meter forms: 2S for single-phase, and 9S for multi-phase.

Nexus1252. Advanced Performance Power Meter and Data Acquisition Node. New Technology! Total Web Solutions

Digital Multifunction Meters. Digital Multifunction Meters

SUBJECT TO CHANGE WITHOUT NOTICE

PM800 series. Applications

Nexus1262/1272. High Performance Utility Billing Meters. With Communication & Advanced Power Quality. Accu-Measure Auto-Calibrating Metrology

U niversal Measuring Device NEW! UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs.

Designed For Reliability Manufactured To Last

KS5 SYNCHRONIZATION METER

Energy Management BUS Adapter Type VMU-B 01

!"!#$!%&'()!%*+,-%./0/123&&45&

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

AP25-1DO METER (MID CERTIFIED) User Manual - Issue 1.0

Transcription:

SH RK 100S SH RK 200S ELECTRONIC SUBMETERS WITH WIFI ETHERNET CPBILITY Shark 200S Meter NEW INDUSTRY LEDING TECHNOLOGY High Performance Metering Technology Shark 100S Economical WiFi Submeter Real Time Monitoring Only 0.2% ccuracy Class Highly ccurate Revenue Certifiable Test Pulse with KYZ Output www.electroind.com IEEE 802.11 Wireless Ethernet Capability 10/100BaseT Ethernet RJ45 Modbus RS485 or Modbus TCP For Commercial Building, Industrial and Shopping Mall pplications 2 Megabytes Flash Memory for Extensive Datalogging (Shark 200S Submeter) Shark 200S dvanced Datalogging WiFi Submeter Onboard Logging, utomated Billing Electro Industries/GaugeTech The Leader in Power Monitoring and Smart Grid Solutions MV90 COMPTIBLE

Feature Summary 0.2% Class Revenue Certifiable Energy and Demand Submeter Meets NSI C12.20 (0.2%) and IEC 6205322 (0.2%) Classes Multifunction Measurement Capability Bright Red LED Display with three.56" lines % of Load Bar for nalog Meter Perception Ethernet or Wireless Ethernet (Modbus TCP) Serial RS485 Communication (Modbus RTU/SCII) Direct Interface with Most Building Management Systems Very Easy To Install Extensive Datalogging and larm Recording (Shark 200S Submeter) Highly ccurate Metering, Simple Communication Technology pplications Universities Commercial Buildings Shopping Malls irports Industrial Submetering Government Facilities Military Energy Efficiency OEMs Introduction Electro Industries introduces the most advanced series of electrical submeters available. These high performance products measure revenue grade electrical energy usage and communicate back information using RS485, RJ45 Ethernet or IEEE 802.11 WiFi Ethernet connections. Place a unit anywhere within a facility and it can communicate back to central software quickly and automatically. The units use standard 5 or 1 mp CTs (either split or donut). They surface mount to any wall and are easily programmed in minutes. Use Ethernet or WiFi to easily meter any facility 2

VSwitch Technology Measurement Upgrade Packs The Shark 100S/200S submeters are equipped with EIG s exclusive VSwitch technology, a virtual firmwarebased switch that allows you to enable meter features through communication, even after installation. Using VSwitch keys, you can purchase what you require now and field upgrade functionality as needed. This allows you to optimize your metering investment. Begin with a simple energy billing submeter and upgrade it to a full functionality energy billing meter with power quality and alarm measurements. Shark Series Submeter ccuracy (Class 10) Measured Values Voltage LN Voltage LL Current ccuracy 0.1% of Reading 0.1% of Reading 0.1% of Reading +/ Watts 0.2% of Reading +/ Wh 0.2% of Reading +/ VRs 0.2% of Reading +/ VRh 0.2% of Reading vailable VSwitches: V3 (100S only) Volts, mps, kw, kvr, PF, kv, Freq, kwh, kvh, kvrh V4 (100S only) Volts, mps, kw, kvr, PF, kv, Freq, kwh, kvh, kvrh, %THD Monitoring and Limit Exceeded larms V33 (200S only) Volts, mps, kw, kvr, PF, kv, Freq, kwh, kvh, kvrh, 2 Megabytes Datalogging memory and Limit Exceeded larms Note: The Shark 200S submeter does not have an upgrade for harmonic measurements. Generate Cost llocation and Billing Using Electro Industries EnergyReporter EXT software, you can track energy usage data to provide utility bills for usage and demand. You can also customize rate structures and aggregate multiple meters for billing. The EnergyReporter EXT application produces bills utilizing either Energy Manager HMI EXT logging or from data stored in Shark 200S logs. For simple bill generation we highly recommend using the Shark 200S submeter with internal logging. V Vh PF Frequency 0.2% of Reading 0.2% of Reading 0.2% of Reading 0.03 Hz (100S) / 0.007 Hz (200S) Lower demand cost Provide meter billing services Provide user accountability for actual usage %THD (Shark 100S only) 5.0 % Load Bar +/ 1 Segment Traceable WattHour Test Pulse for ccuracy Certification To be certified for revenue metering, power providers and utility companies need to know that the billing energy meter will perform to its stated accuracy. To verify the meter s performance and calibration, power providers use field test standards to insure that the unit s energy measurements are correct. Since the Shark 100S/200S submeters are traceable revenue meters, they contain a utility grade test pulse allowing power providers to verify and confirm that the meters are performing to their rated accuracy. This is an essential feature required of all billing grade meters. 3

Utility Peak Demand Metering The Shark 100S/200S submeters provide userconfigured Block Window or Rolling Window Demand. This allows you to set up a particular utility demand profile. Block Window Demand is demand used over a fixed userconfigured demand period (usually 5, 15 or 30 minutes). Rolling Window Demand is a fixed window demand that moves for a user specified subinterval period. n example is a 15minute demand using 3 subintervals, providing a new demand reading every 5 minutes based on the last 15 minutes. Readings for kw, kvr, kv and PF are calculated using utility demand structures. Other parameters offer max and min capability over the userselectable averaging period. Voltage provides a nonrolling instantaneous max and min reading, displaying the highest surge and lowest sag seen by the meter. dvanced Communication Capability with IrD Interface Standard Modbus RS485 Communication Standard communication includes an RS485 output speaking Modbus protocol. This allows the unit to be connected to any serial RS485 bus using the Modbus interface. The unit communicates easily with most building automation or other software systems. Baud rates are up to 57.6K baud to provide fast update times. WiFi or Land Based Ethernet The unit offers two Ethernet options either an RJ45 or WiFi connection. The WiFi option allows the 100S/200S submeter to be used on standard WiFi base stations. The unit is assigned an IP address; it communicates Modbus protocol over Ethernet TCP/IP. IrD Port Use an IrDequipped laptop PC to program and read the Shark 100S/200S submeter. KYZ Pulse For applications in which a pulse is needed, the unit also provides a KYZ output which pulses proportional to the amount of energy consumed. This feature is used for pulse counting applications or for building management systems where serial or Ethernet protocol is not available. Wireless ntenna IrD for Laptop PC Communication % of Load Bar for Current Loading Easy View LED Display High ccuracy Measurement Circuitry Voltage & Current s WiFi Ethernet RJ45 Ethernet/Modbus TCP KYZ Pulse RS485 Modbus 4

Superior Ethernet Simplifies Meter Connectivity These submeters harness the latest Ethernet technology by providing a simple, overthecounter wireless architecture. The submeter communicates over any existing wireless or wired Ethernet infrastructure. Just install the unit, plug in its IP address, and the device automatically connects to your LN wirelessly. You can extend the network simply by adding WiFi access points. Wireless Ethernet is reliable and easy to integrate, making it the superior solution for mass meter deployment. Shopping Mall or Commercial pplication Store 1 Store 2 Store 3 WiFi BSE Ethernet ccess Point to Network IEEE 802.11 WiFi Ethernet Store 4 Store 5 Store 6 Shark Submeter Benefits of Wireless Ethernet over Dedicated 900 MHz Spread Spectrum Standard Infrastructure (No Dedicated Hardware) PC Software Reading Meters to Network WiFi BSE Ethernet ccess Point nchor Low Cost to Deploy and Expand Superior Speed Over Dedicated Wireless Networks Significantly Easier to Configure and Maintain PC Connected nywhere on Ethernet (Internet or Intranet ccess) Standard Modbus TCP Data Stream Can Be Easily Integrated Through the Internet WiFi Ethernet the simplest way to implement a fast, reliable metering project Shark 200S dvanced Logging Features Extensive Datalogging Capability The Shark 200S submeter has 2 Megabytes of Flash memory that gives it extensive datalogging capability. The 200S offers three Historical logs, a Limits (larm) log, and a System Events log. The unit has a realtime clock that allows for timestamping of all the data in the instrument when log events are created. Historical logs: Each of the three historical logs can be programmed with unique parameters consisting of any measured reading. Up to 64 parameters can be recorded per log. Limits (larm) log: The Limits log provides magnitude and duration of an event. 2048 events are available; the log provides timestamp and alarm value. System Events (antitampering) log: To protect critical billing information, the meter records and logs the following with a time stamp: Demand/Energy/Log resets Password requests System startup Log reads Changes to meter s programmable settings larm Log Historical Trending 5

Dimensional Drawings 3.70 9.4cm 7.53 19.1cm 5.60 14.2cm MOUNTING PLTE 7.90 20.1cm 7.90 20.1cm 0.50 0.27cm 5.95 15.1cm ntenna Length: 4.4 (11.2cm) 3.11 7.9cm Installation Opened Opened Closed Circuit Board Circuit Board Lockable Revenue Seal 6 Open for Installation Close for Operation

Wiring Diagrams N LINE N LINE Electronic Circuits Electronic Circuits CT Shorting Block Ia+ Ia Ib+ Ib Ic+ Ic CN1 CN2 CT Shorting Block Ia+ Ia Ib+ Ib Ic+ Ic CN1 CN2 Va Vb Vc Vref L1 L2 PE Va Vb Vc Vref L1 L2 PE FUSES 3 x 0.1 Va Vb Vc Vref L1 L2 FUSE 3 GND FUSES 3 x 0.1 Va Vb Vc Vref L1 L2 FUSE 3 GND L(+) N() L(+) N() Power Supply Power Supply N LOD N LOD 3 Phase 4 Wire WYE Direct 3 Phase 4 Wire WYE with PTS LINE LINE Electronic Circuits Electronic Circuits CT Shorting Block Ia+ Ia Ib+ Ib Ic+ Ic CN1 CN2 CT Shorting Block Ia+ Ia Ib+ Ib Ic+ Ic CN1 CN2 Va Vb Vc Vref L1 L2 PE Va Vb Vc Vref L1 L2 PE FUSES 3 x 0.1 Va Vb Vc L1 L2 FUSE 3 GND FUSES 2 x 0.1 Va Vb Vc L1 L2 FUSE 3 GND L(+) N() L(+) N() Power Supply Power Supply LOD LOD 3 Phase 3 Wire Delta Direct 3 Phase 3 Wire Delta with PTS 7

Specifications Voltage Inputs 20416 Volts Line To Neutral, (Shark 100S meter), 20576 Volts Line to Neutral (Shark 200S meter) 0721 Volts Line to Line Universal Voltage Input Input Withstand Capability Meets IEEE C37.90.1 (Surge Withstand Capability) Programmable Voltage Range to ny PT ratio Supports: 3 Element WYE, 2.5 Element WYE, 2 Element Delta, 4 Wire Delta Systems Burden: 0.36V per phase Max at 600V, 0.014V at 120 Volts Current Inputs Class 10: 5 mp Nominal, 10 mp Maximum Class 2: 1 mp Nominal, 2 mp Secondary Programmable Current to ny CT Ratio Burden 0.005V per phase Max at 11mps 5m Pickup Current for Class 10 1m Pickup Current for Class 2 Current Surge Withstand: 100/10 Seconds at 23 C Isolation ll Inputs and Outputs are galvanically isolated to 2500 Volts C. Environmental Rating Storage: (20 to +70) C Operating: (20 to +70) C Humidity: to 95% RH (Noncondensing) Sensing Method RMS Sampling at 400+ Samples per Cycle on all channels measured readings simultaneously Harmonic %THD (% of Total Harmonic Distortion) Shark 100S meter only Update Rate Watts, VR and V Every 6 cycles (e.g., 100ms @ 60Hz) ll other parameters Every 60 cycles (e.g., 1s @ 60Hz) (1 second for Current Only measurement, if reference voltage is not available) Power Supply (90 to 400) Volts C and (100 to 370) Volts DC. Universal C/DC Supply Burden: 16V max. Communication Format 2 Com Ports RS485 Port IrD (Through Faceplate) Protocol Modbus RTU, Modbus SCII Com Port Baud Rate: (1200 to 57600) Com Port ddress: 0247 8 Bit, Parity setting: Odd, Even, None Modbus RTU or SCII Protocols Ethernet 802.11b Wireless 10/100BaseT Ethernet (RJ45) Modbus TCP Protocol Dimensions and Shipping Weight: 4 lbs / 1.81 kg 7.9H x 7.5W x 3.1D in 20.1H x 19.1W x 7.9D cm Meter ccuracy See page 3 Compliance: IEC 6205322 (0.2% ccuracy) NSI C12.20 (0.2% ccuracy) NSI (IEEE) C37.90.1 Surge Withstand NSI C62.41 Burst EN6100062 Immunity for Industrial Environments: 2005 EN6100064 Emission Standards for Industrial Environments: 2007 EN613261 EMC Requirements: 2006 Certified to UL 610101 and CS C22.2 No. 610101, UL File: E250818 CS C22.2 No. 610101, UL File: E250818 RECH/RoHS Compliance Ordering Information To order, please fill out ordering guide: Option Numbers: Example: Shark 100S Model Frequency Current VSwitch TM Communication Class Pack Format 60 10 V3 485 Shark 100S 50 10 V3* 485 50 Hz 5 mp Default with RS485 System Secondary Energy Counters (Shark 100S) Shark 200S 60 2 V4* WiFi 60 Hz 1 mp bove with Wireless or System Secondary Harmonics and Limits LN Based Ethernet (Shark 100S) * Shark 100S meter only ** Shark 200S meter only dditional ccessories Communication Converters CB 6490 USB to IrD dapter for Programming Unicom 2500 RS485 to RS232 Converter Unicom 2500F RS485 to RS232 to Fiber Optic Converter Modem Manager, Model # MM1 RS485 to RS232 Converter for Modem Communication V33** MultiFunction Meter with 2 MB Datalogging Memory (Shark 200S) CT400K 400/5 Ratio, 1.25 Window, 3 CTs CT800K 800/5 Ratio, 2.06 Window, 3 CTs CT2000K 2000/5 Ratio, 3.00 Window, 3 CTs CT Specifications: Frequency: 50 to 400Hz; Insulation: 600 Volts, 10kV BIL Flexible Leads: UL 1015 105 C, CS pproved, 24 Long, #16WG Compliance Documents Certificate of Calibration, Part #: CCal This provides Certificate of Calibration with NIST traceable Test Data. Current Transformer Kits CT200K 200/5 Ratio 1.00 Window 3 CTs Electro Industries/GaugeTech 1800 Shames Drive Westbury, NY 11590 1 877EIMETER (1 8773463837) EMail: sales@electroind.com Tel: 5163340870 Web Site: www.electroind.com Fax: 5163384741 Software Option Numbers COMEXT4P Communicator EXT Software, Single License * Consult factory application engineer for additional transformer ratios, types or window sizes. EnergyReporter EXT Software utomated usage reporting and bill generation software for Shark 200S Submeter only. E145722 110916 V.1.14