SL 200 INTEGRATING-AVERAGING SOUND LEVEL METER

Similar documents
Mini Sound Meter. Instruction Manual SPER SCIENTIFIC

Digital Sound Level Meter

TITLE PAGE I. Safety Information II. General Description III. Specifications IV. Controls V. Calibration Procedures VI. Measurement Preparation

Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

GM-200 HYDROMETER INTRODUCTION TECHNICAL DETAILS

GM-200 HYDROMETER INTRODUCTION TECHNICAL DETAILS

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

Pro II. Sound Level Meter V-9992

Personal Sound Level Meter

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

Model R8050. Instruction Manual. Sound Level Meter. reedinstruments. REED Instruments

Integrating Sound Level Datalogger Model

Digital Sound Level Meter with USB Model:

CM-140. Instruction Manual SOUND LEVEL METER G A L A X Y A U D I O

CONTENTS Safety Information Description Features Specifications Nomenclature And Function Operating Preparation Calibration Procedure

SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1

Sound Analyser Real Time 1/1 & 1/3 Octave band Analysis

Pocket type SOUND LEVEL METER Model : SL-4030

Sound Level Pen Instruction Manual

SOUND LEVEL CALIBRATOR DVM1356 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1356 SOUND LEVEL CALIBRATOR 1

TES-1358 INSTRUCTION MANUAL

1. GENERAL DESCRIPTION & SPECIFICATIONS

DIGITAL SOUND LEVEL METER. Instruction Manual

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

User's Guide. Digital Sound Level Meter. Model

DIGITAL SOUND METER WITH JUMBO DISPLAY

User's Manual Sound Level Alert Model SL130

CONTENTS Safety Information Description Features Specifications Nomenclature And Function Operating Preparation Calibration Procedure

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

Sound Level Meter SD Card real-time Datalogger

Digital Sound Level Meter

TES-1353S INSTRUCTION MANUAL

OPERATION MANUAL. SD card real time data Recorder, USB/RS232 SOUND LEVEL METER. Model : SL-4023SD. Your purchase of this

USER S MANUAL. Data Logger SOUND LEVEL METER.

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

USER GUIDE. Noise Dosimeter with PC Interface. Model

USER GUIDE. Model Noise Dosimeter with PC Interface

Noise Dosimeter, Datalogger, and Sound Level Meter With PC Interface

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

INSTRUCTION MANUAL REC FAST A/C

Torque Meter. Instruction Manual

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

Digital Sound Level Meter

Sound Level Calibrator

ATE-9051 User s Manual

HD 46 HME 46. Instructions for use

Sound Level Meter SL-4035SD. Operation Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Instruction Manual RS-1660

Contents. 1. Safety information 1 2. Description 2 3. Specifications 6 4. Operating instruction 8 5. Accessories 12

INSTRUCTION MANUAL SPL82 DATA LOGGER SOUND LEVEL METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING. CONTENTS Safety Information

Digital Sound Level Meter MODEL

User's Guide. Model Noise Dosimeter with PC Interface. Introduction

DSM403SD USER S MANUAL

Instruction Manual Digital Sound Level Meter

Manual Sound level indicator PCE-353

RS-232. ital Measurement Metrology, Inc ECISION IS OUR VISION LEVEL REC SETUP MAX MIN FAST SLOW INTV CLOCK.

SOUND LEVEL METER INSTRUCTION MANUAL

User Manual. Thermocouple Datalogging Thermometer. Model EA15

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

Visit us at Back to the Extech Product Page

! SCARLET TECH. Sound Level Meter ST-109/107S User Guide

User s Manual. Sound Level Meter. FSM 30Plus. Lo/Hi MAX HOLD S/F. S F db BAT. SOUND LEVEL: Lo=35~100dB Hi=65~130dB. 94dB

Light Meter with Bar Graph

Advanced Datalogging Sound Meter Instruction Manual

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

Torque Meter. Instruction Manual

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

TLKR T60/T61 OWNER'S MANUAL

HOLDPEAK Sound Level Meter Instruction Manual

SOUND LEVEL DATALOGGER. Instruction Manual - 1 -

INSTRUCTION MANUAL. Models: H100 Light Meter

Manual SOUND LEVEL METER PCE-322 A

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

Vibration Meter SD Card real-time datalogger

Indoor Air Quality Meter/Datalogger

EM10 TEMPERATURE / HUMIDITY /DEW POINT METER

Operation Manual for OLS-1315 Optical Light Source

Vibration Meter Instruction Manual

Digital Sound Level Meter

User's Manual. Digital Sound Level Meter. Model

testo Sound Level Meter Instruction Manual

UÊ, Ê* - 1 Ê Ê Ê " /",Ê

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter

Video Borescope Inspection Camera

Thank you for your purchase USER MANUAL

User Guide. Moisture Meter. Model MO250

True RMS AC Voltage/Current Datalogger

SD Model. Instruction Manual. Sound Level Meter/ Data logger. reedinstruments. www. com

Infrared Thermometer Remote Temperature Measurement ( Non-Contact ) TES-1326S INSTRUCTION MANUAL

Dual Moisture Meter Pin / Pinless Moisture Meter

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

USER GUIDE Turbidity Meter Model TB400

INSTRUCTION MANUAL Sound Level Meter NL-27

Important Instructions for Use

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume

Operation Manual for OPM-1315 Optical Power Meter

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

7032 Digital-Analog Multimeter

HMEC Instructions for use

USB DIGITAL SOUND LEVEL DATA LOGGER USER S MANUAL DSM20

Transcription:

SL 200 INTEGRATING-AVERAGING SOUND LEVEL METER 1. Introduction SL-200 is a high performance, integrating-averaging sound level meter with an easy-to-use interface for quick and simple measurements. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Features include: Simple sound level checks Complies with IEC61672-1 CLASS 2 Standard Single measurement range 30 to 130 db Fast, slow time weighting settings A and C frequency weighting settings Record max/min values over time Storage for last ten measurements Adjustable backlight Auto power-off Adjustable measurement time up to 10 hours Quasi-analogue bar graph Large LCD display screen for easy reading Tripod mountable Frequency range 31.5 Hz - 8 khz

2. Meter description (1) A/C Frequency weighting button (menu up) (2) Power button (3) FAST/SLOW (F/S) time weighting button (menu down) (4) ½ inch microphone (5) LCD display: (a) Sound pressure level value (LAF,LAS,LCF or LCS) (b) A/C: frequency weighting indicator (c) F/S: (Slow/Fast) time weighting indicator (d) min: minimum sound level reading (e) max: maximum sound level reading (f) Bar graph represents the current sound level (2.5dB resolution) (5) (g) LAeq: equivalent continuous sound level indicator (h) LAeq: equivalent continuous sound level reading (i) Elapsed time indicator: Displays the amount of time that has passed since measurement (j) Battery indicator (k) db: sound level unit (decibel) (l) Measurements status indicator: - calculations are being made - calculations are stopped (1) (4) (2) (3) LCD display description Main screen (LAF,LAS,LCF or LCS) (j) (f) (a) (d) (c) (k) (b) (e) Measurement screen (LAeq) (j) (h) (f) (d) (i) (l) (g) (e)

3. Menu description Press and hold the F/S button for 3 seconds to access the menu. Buttons are used to navigate through the items. Press the button to access desired position. You can choose from the following menu items: <Measurement time> <View results> <Backlight> <Language> <Calibration> <System information> <Default settings> <Exit> <Measurement time> With this function you can set measurement time. Use the buttons to set desired hours. Press the button to move to the next parameter (minutes), repeat this procedure until the desired minutes and seconds have been set. <View results> This option allows you to see the last ten saved measurement results. Press the scroll through the list of results. Press the button to go back to the menu. <Backlight> Press the buttons to increase/decrease the backlight level. Press the setting and back to the menu. buttons to button to save the To extend battery life during measurement, the meter automatically turns off the display backlight if you do not press any button for 6 minutes. To turn the backlight on again, press any button. <Language> Use the buttons to switch between languages (English, Deutsch, Nederlands). Press save the setting and go back to the menu. to <Calibration> Calibrating the Integrating Sound Level Meter (SL-200) requires an acoustical calibrator which provides a stable sound pressure at 1kHz and 94dB. Using the buttons, you can select one of the two types of calibration: 1. Factory Select this option if you want to use the meter factory calibration set during manufacture. 2. User Select this option if you want to use your own calibration. If you decide to select option "User," you will be able to choose between a new calibration (NEW press button F/S ) and the calibration of the user stored in the device's memory (CURRENT press button A/C ).

Option "NEW" allows you to perform a new calibration as follows: 1. Stand away from loud sound sources that may interfere with the calibrator's signal. 2. Fit Sound Level Calibrator carefully onto the sound level meter and rest the assembly on the table or other flat surface as shown in fig.3.1. 3. Switch on the calibrator and wait approximately 5 seconds for all levels to stabilize. 4. Press the F/S button to START calibration. 5. Wait until the display shows the value in the range of 93.8-94.0 db. If after a five-second wait, the result is not within the range of 93.8 94.0dB press the 6. To confirm and save the calibration, press the A/C F/S button again. button. fig.3.1 Sound Level Calibrator fitted onto your sound level meter. <System information> This option is used to display information about the system which includes: firmware version date of production counter starts total working time Press the button to go back to the menu. <Default settings> This option is used to restore default settings. Press the to go back to the menu. This option sets to the default: measurement time 30 minutes language English backlight 100% calibration factory removes the list of saved 10 results <Exit> Press the F/S button to confirm the reset or the button button to back to main screen. A/C

4. Making a Measurement 1. Press the button to switch the meter on. 2. Press the A/C button to select the desired frequency weighting. 3. Press the F/S button to select the desired response time. 4. The numeric level indication on the display shows the currently measured sound level. The reading is updated depending on the chosen FAST/SLOW response time. FAST 0.5s SLOW 1.0s 5. The quasi-analogue bar graph shows current sound pressure level. The reading is updated depending on the chosen FAST/SLOW response time. FAST 0.125s SLOW 1.0s 6. The max indicator shows the maximum sound level encountered during the measurement period; the min indicator shows the minimum sound level. Press the button to reset min and max value. In order to access the measurement screen (LAeq - measurement), press and hold the button for 2.5 seconds. A/C By default, the LAeq (Equivalent continuous sound level) measurement is stopped. Press the button to start measurement. The current measurement time is displayed at the top of the display. You can press the button F/S to save measurement. You can press and hold the F/S button for 2.5 seconds to check the total measurement time. You can go back to the main screen any time when measurement is running by pressing the A/C button. When the measurement ends, the measurement status indicator changes form to.the measurement time and the LAeq will be automatically stored in the meter's memory. To start measurement again press the twice. Note. When measurement is running you cannot change frequency weighting filter and access to the menu. In this case you will see on the display warning Option locked when measurement is active!. To unlock this option, go back to the measurement screen and stop measuremet (press the button ).

Switching off the instrument In order to switch the equipment off, press and hold the button for approx. 3 seconds. Note that switching off the equipment is only possible from the main screen. The measuring instrument can switch off automatically after 6 min. If the battery conditions are so low that in fact it could lead to errors during the measurement the equipment will automatically switch off, which is signaled earlier by the battery empty indicator. 5. Maintenance and Service SL200 is designed and constructed to provide many years of reliable operation. However, if a fault occurs that impairs the meter's correct function, then remove the batteries to prevent rish of futher damage. For more information about preventing faults or damage to your sound level meter, please read the Instrument Care section below. Warranty Notwithstanding the statutory warranty claims, CAISSON provides a warranty in accordance with the laws of the Customer's country for a period of at least two years from the date of sale of the device to the end user. The warranty covers only those faults which are caused by defects in material or workmanship. A warranty claim must be accompanied by a proof of purchase with the date of sale specified. Warranty repairs shall only be performed by an authorized distributor of CAISSON. The following are excluded from the warranty: Use of force, damage caused by external factors or foreign bodies such as sand or water Damage caused by failure to comply with the instructions for use Normal wear and tear The warranty does not cover devices that are partially or entirely disassembled. Instrument Care Protect the instrument from impact. Do not drop it or subject it to rough handling. Transport it in the supplied carrying case. Never mix fresh and partially-used batteries. Do not attempt to remove the mesh cover from the microphone as this will cause damage and affect the accuracy of the instrument. Protect the instrument from water, dust, extreme temperatures, high humidity and direct sunlight during storage and use. For long-term storage, remove the batteries. Do not leave exhausted batteries in the instrument, as they may leak and cause damage. If the instrument casing becomes dirty, then wipe it with a lightly dampened cloth. Do not use abrasive cleansers and solvents. Do not allow moisture to enter the microphone, connectors or casing.

Power supply The SL200 is powered by two AA batteries. You may use either disposable or rechargeable batteries. The Battery status indicates the battery charge level. If an empty battery icon is displayed, replace the batteries. Batteries should be replaced with a new set of batteries of the same kind. Do not use a rechargeable battery in combination with a disposable battery or a partially discharged battery with a full battery. The figure below shows the location of the batteries in the battery compartment.

6. Specifications STANDARDS Conforms with the following: IEC61672-1 CLASS 2 Standard Update Cycle: 0.5 s (numeric), 0.125 s (bar graph) Fast 1 s (numeric), 1 s (bar graph) Slow ACCURACY ± 1.0 db (ref. 94dB@1kHz, 125Hz, 4kHz) ± 2.0 db ( < 100Hz ) Elapsed Time Display: from 00h 00m 00s up to 10h 00m 00s FREQUENCY RANGE 31.5 Hz to 8 khz DYNAMIC RANGE 100 db MEASURING RANGES RMS: Total range 30 130 db Peak: 30 133 db NOISE FLOOR Below measurement range < 29 db FREQUENCY WEIGHTINGS A-weighting (RMS) C-weighting (Peak) TIME WEIGHTING 'F' (Fast) 'S' (Slow) MICROPHONE Micro-Electro-Mechanical Systems (MEMS) Sensitivity: -46dBFS SNR: 65dbA Maximum SPL level: 160dB DISPLAY LCD showing: Input signal level indicated with a quasianalogue bar Warnings for: low battery Frequency and time weighting Minimum and maximum peak sound pressure level SETTLING TIME Less than 4 s REFERENCE CONDITIONS Reference Sound Pressure Level: 94dB Reference Temperature: 22 C Reference Frequency: 1000Hz Reference RH: 55% ENVIRONMENTAL EFFECTS Storage Temperature: -30 to 55 C Operating Temperature: -5 to 50 C BATTERIES Two 1.5V LR6/AA-size alkaline batteries Power Consumption During Normal Operation: Less than 300mW Lifetime (at room temperature): Approximately: 20h PHYSICAL CHARACTERISTICS Dimensions: 162 x 79 x 25 including microphone Weight: 190 g (143 g) including batteries ORDERING INFORMATION Type SL100 Sound Level Meter Type SL200 Integrating-averaging Sound Level Meter Included Accessories: Two alkaline batteries