DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

Similar documents
DATA SHEET. Advanced Power Meter, APM 380 & APM 305

Installation and Operating Instructions

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

MIC-2 Multi-instrument DATA SHEET

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Jiaxing Eastron Electronic Instruments Co.,Ltd. Tel: Fax:

MIC-2 MKII, Multi-instrument DATA SHEET

Siemens AG Measuring Devices and E-Counters. Configuration Manual 10/2010 SENTRON. Answers for infrastructure.

DATA SHEET Selectable AC transducer, TAS-331DG

User Manual V1.0 SDM230-DR. Single-Phase Two Module DIN rail Meters

Measuring Devices and

DATA SHEET Selectable AC transducer, TAS-321 DG

IPM-S500 Series MID SINGLE PHASE AND THREE-PHASE ENERGY COUNTERS

USER MANUAL 2012 V1.1

User Manual V1.1. SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter

MID Energy Counters. Getting together is a beginning, staying together is a progress, working together is an achievement.

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

SUBJECT TO CHANGE WITHOUT NOTICE

SDM530CT-Modbus USER MANUAL 2015 V1.6. Three Phase Multi-function DIN rail meter. Eastron SDM530CT-Modbus User Manual

Energy Management Energy Transducer Type ET112

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

SDM530-Modbus USER MANUAL 2015 V1.5. Three Phase Multi-function DIN rail meter. Eastron SDM530-Modbus User Manual

Digital Multifunction Meters. Digital Multifunction Meters

EM270. Multi-channel power analyzer. Benefits. Description

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

/ Type approved according to:

AP25-1DO METER (MID CERTIFIED) User Manual - Issue 1.0

Multifunction Transducer MT440

COUNTIS E05. Single-phase energy meter Direct - 40 A M-BUS. Instruction manual. en/countis-e0x

EngyVolt RV12 and RV15

DIN Rail Smart Meter for Single and Three Phase Electrical Systems

Electrical Energy Meter with integrated Serial Modbus interface

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

Leader in DIN rail measurement and communication instruments

DZT Line Deutsche Zähler Technik

EM271. Multi-channel power analyzer. Benefits. Description

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

DATA SHEET IOM 200 analogue interface for AGC 200

Controls Division. Mounting. Mounting Terminal connections main circuit. Terminal connections control circuit. Insulation characteristics

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Multifuncion Measuring Device 96x96 mm, connection via CT

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

OB735 Smart Energy Meter

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

DEIF A/S. Generator Paralleling Controller multi-line L. Type GPC / GS. Compact system in one unit

CEM-C6 INSTRUCTION MANUAL (M187B B)

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

CEM-C30 INSTRUCTION MANUAL (M017B A)

02/11/2015

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

FU2200B FU2200B V Ethernet Power Meter with Data Logger. Features. Applications

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

with Backlight Graphic LCD Screen

ANALIZZATORE DI RETE TRIFASE 90A

SINGLE PHASE AMR ELECTRONIC METER MEM Electric meter has the following functions: Technical information

TECHNICAL DESCRIPTION WM1 6, WM1M6

User s Manual. Single phase electrical energy meter WM1 6 Single phase electrical energy meter WM1 6Z Single phase electrical energy meter WM1M6

DATA SHEET Compact Genset Controller, CGC 200

Data sheet Single phase Energy meter with integrated S-Bus interface

Leader in DIN rail measurement and communication instruments

MultiCube Single Phase Multi-Function Electricity Meter. Installation and Operation

Power Meter PowerMonitor 500

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

DATA SHEET. AGC PM Automatic Genset Controller, Plant Management

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM35TF V AC

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

02/11/2015

Generator Protection Unit, GPU-3 Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

DATA SHEET Advanced Graphical Interface, AGI 100 series

Generator Protection Unit, GPU-3 Gas Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

Generator Paralleling Controller, GPC-3 Gas Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

NEMO HD MULTI-FUNC METER BASE (MF96001)

E-STOP relays, safety gate monitors

DI572 Digital Input Module

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Transcription:

DATA SHEET Advanced Energy Meter, AEM 380 & AEM 305 Easy installation MID-approved 5 optional communication interfaces Phase error detection Low power consumption Two tariffs Two-pulse output DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4921210134B SW version: N/A

1. General information 1.1. Application and overview...3 1.1.1. Application...3 1.1.2. Overview...3 1.1.3. Functionality...3 1.1.4. AEM 380 standard module housing...4 1.1.5. AEM 305 standard module housing...5 2. Technical information 2.1. Technical data...6 2.1.1. General characteristics...6 2.1.2. Dimensions and circuit diagrams...11 3. Ordering information 3.1. Order specifications and disclaimer...12 3.1.1. Order specifications...12 3.1.2. Disclaimer...12 DEIF A/S Page 2 of 12

General information 1. General information 1.1 Application and overview 1.1.1 Application The energy meters with a green back-lighted LCD screen for perfect reading are used to measure threephase systems or single-phase like in Residential, Utility and Industrial applications. Monitoring of the energy consumption goes via a S0 pulse output. The products can be set up to communicate with LAN, Modbus RTU/ASCII, MBus, and KNX interfaces are used to analyse the energy consumption to reduce the running cost to a minimum for Industrial plants and buildings like offices, hospitals, universities etc. 1.1.2 Overview Active energy meters for three-phase alternating current with one 7.1 digit digital counter. These meters have 2 S0 output generating pulses for remote processing of the instantaneous energy active and reactive measurements for 2 tariff. Green backlighted LCD For direct connection 80 A, or for transformer.../5 A For transformer primary current of 5 A to 10.000/5 A. Input is in 5 A increments 7.1 digit display for energy values indication Parameter also readings from front mounted IR in accordance with EN 62056-21 Detection of connection errors (phase transposition) Accuracy class 1 for active energy according to EN 50470-3 (B) Accuracy class 2 for reactive energy according to EN 62053-23 The standard versions are designed to be combined with communication interfaces Energy register for import and export Instantaneous power active and reactive display Sealable terminal covers 4 DIN modules wide (72 mm) 1.1.3 Functionality Readouts Active energy Tariff 1 Tariff 2 Reactive energy Tariff 1 Tariff 2 kwh kwh kvarh kvarh Unit ID Energy absorbed or supplied Energy absorbed or supplied Energy absorbed or supplied Energy absorbed or supplied Active power (k-m) W Utilisation and instantaneous value Reactive power (k-m) var Utilisation and instantaneous value Connection errors PHASE Err Primary transformer 5... 10.000/5 A CT (current transformer) DEIF A/S Page 3 of 12

General information Display The AEM 380/305 has been fitted with a liquid crystal display with illuminated green background. 1.1.4 AEM 380 standard module housing The standard module housing is suitable for DIN rail mounting, direct connection 80 A. 1. Backlighting makes the display easy to read 2. Optic control IR for external communication 3. Precision control LED 4. Supply terminals 80 A direct connection 5. Terminals S0 pulse outlet and tariffs change command 6. Space for the certification data can be provided on request 7. Readout selection push-button DEIF A/S Page 4 of 12

General information 1.1.5 AEM 305 standard module housing The standard module housing is suitable for DIN rail mounting, connection through CT.../5 A till 10.000/5 A. 1. CT selection (5 to 10,000/5 A - 5 A step) 2. Backlighting makes the display easy to read 3. Optic control IR for external communication 4. Precision control LED 5. Supply terminals CT connection (5 to 10,000 A) 6. Terminals S0 pulse outlet and tariffs change command 7. Space for the certification data can be provided on request 8. Readout selection push-button DEIF A/S Page 5 of 12

Technical information 2. Technical information 2.1 Technical data 2.1.1 General characteristics Technical data In compliance with EN 50470-3, EN 62053-23 and EN 62053-31 General characteristics Direct connection 80 A CT connection till 10,000/5 AA Housing DIN 43880 DIN 4 modules 4 modules Mounting EN 60715 35 mm DIN rail DIN rail Depth mm 70 70 Reference standard - Operating features Connectivity Storage of energy values and configuration Display tariffs identifier Supply Rated control supply voltage Un EN 62053-23-31 EN 62053-23-31 EN 62053-23-31 to single/three-phase network digital display (EE- PROM) for active and reactive energy n wires 2-3-4 2-3-4 - yes yes n 2 T1 and T2 T1 and T2 VAC 230 230 Operating range voltage V 184... 276 184... 276 Rated frequency fn Hz 50 50 Rated power dissipation Pv Overload capability Voltage Un continuous phase/ phase VA (W) <8 (0,6) <8 (0,6) V 480 480 1 second: phase/phase V 800 800 continuous phase/n V 276 276 1 second: phase/n V 460 460 Current Imax continuous A 80 6 momentary (0,5 s) A - 120 momentary (10 ms) A 2400 - DEIF A/S Page 6 of 12

Technical information Technical data In compliance with EN 50470-3, EN 62053-23 and EN 62053-31 Display (readouts) Connection errors and phase out discernible from phasesequence indic. Direct connection 80 A CT connection till 10,000/5 AA - PHASE Err PHASE Err Display type LCD n digits 8 (1 decimal) 8 (1 decimal) Active energy: 1 display, 8 digit + display import or export (arrow) Reactive energy: 1 display, 8-digit + display import or export (arrow) Instantaneous active power: 1 display, 3-digit Instantaneous reactive power: 1 display, 3-digit Instantaneous tariff measurement Transformer primary current digit dimensions mm x mm 6,00 x 3 6,00 x 3 tariffs 2 kwh 0000000,0... 9999999,9 overflow kwh 9999999,9... 0000000,0 tariffs 2 kvarh 0000000,0... 9999999,9 overflow kvarh 9999999,9... 0000000,0 W, kw or MW var, kvar or Mvar 0000000,0... 99999999 99999999... 0000000,0 0000000,0... 99999999 99999999... 0000000,0 000... 999 000... 999 000... 999 000... 999 1 display, 1-digit - T1 or T2 T1 or T2 A - 5... 10,000 Display period refresh s 2 2 Measuring accuracy at 23 ±1 C, referred to nominal values Active energy and power acc.to EN 50470-3 class 1 ±1% (B) ±1% (B) Reactive energy and power Measuring input acc.to EN 62053-23 class 2 ±2% ±2% Type of connection direct transformer.../5 A Voltage Un phase/phase V 400 400 phase/n V 230 230 Operating range voltage phase/phase V 319... 480 319... 480 phase/n V 184... 276 184... 276 Current Iref A 15 - Current In A 80 A 5 Current Imin A 0,75 0,05 DEIF A/S Page 7 of 12

Technical information Technical data In compliance with EN 50470-3, EN 62053-23 and EN 62053-31 Operating range current (Ist... Imax) Transformer current Direct connection 80 A direct connection A 0,025... 80 - CT connection till 10,000/5 AA transformer connection A - 0,010... 6 primary current of the transformer smallest input step adjus. in 5 A steps A - 5...10,000 A - 5 Frequency Hz 50 50 Input waveform - sinus. symm. sinus. symm. Starting current for energy measurement (Ist) Pulse output SO acc.to EN 62053-31 Pulse output for act. and react. energy T1 and T2 Terminal output for direct connection 80 A depending on the transf. factor, adjus. ma 25 10 - yes yes Imp/kWh 500 - Imp/kWh - 100-10-1 Pulse duration ms 50 ±2 ms 50 ±2 ms Required voltage min. (max.) VAC (DC) 5... 230 ±5% (5... 300) Permissible current Permissible current Optical interfaces Front side (accuracy control) pulse ON (max. 230 V AC/DC) Imp. OFF (leak. cur. max. 230 V AC/DC) ma 90 90 ìa 1 1 LED imp/kwh 1000 10 5... 230 ±5% (5... 300) Safety acc. to EN 50470-1 Indoor meter - yes yes Degree of pollution - 4 4 Operational voltage V 600 600 Impulse voltage test 1,2/50 is-kv 6 6 Housing material flame resistance UL 94 class V0 V0 DEIF A/S Page 8 of 12

Technical information Technical data In compliance with EN 50470-3, EN 62053-23 and EN 62053-31 Safety-sealing between upper and lower housing part - yes yes Direct connection 80 A CT connection till 10,000/5 AA Plug-and-play technology - LAN (TCP/IP) Ethernet 802,3-10/100 Mbps 10/100 Mbps Modbus RTU, Ascii RS-485-2 wires - up to 19,200 bps up to 19,200 bps MBus 2 wires - up to 9,600 bps up to 9,600 bps KNX KNX-standard - up to 9,600 bps up to 9,600 bps Connection terminals Type cage main current paths screw head Z +/- Adaptor for Communication POZI- DRIV Type cage pulse output blade for slotted screw mm 0,8 x 3,5 0,8 x 3,5 Terminal capacity main current paths Terminal capacity pulse outlet Environmental conditions PZ2 PZ1 solid wire min. (max.) mm2 1,5 (35) 1,5 (6) stranded wire with sleeve min. (max.) mm2 1,5 (35) 1,5 (6) solid wire min. (max.) mm2 0,14 (2,5) 0,14 (2,5) stranded wire with sleeve min. (max.) mm2 0,14 (1,5) 0,14 (1,5) Mechanical environment - M1 M1 Electromagnetic environment - E2 E2 Operating temperature C -25... +55-25... +55 Limit temperature of transportation and storage Relative humidity (not condensation) Vibrations 50 Hz sinusoidal vibration amplitude C -25... +70-25... +70 % <80 <80 mm ±0,075 ±0,075 DEIF A/S Page 9 of 12

Technical information Technical data In compliance with EN 50470-3, EN 62053-23 and EN 62053-31 Degree protection housing when mounted in front (term.) (*) For the installation in a cabinet at least with IP51 protection. Direct connection 80 A CT connection till 10,000/5 AA - IP51(*)/IP20 IP51(*)/IP20 DEIF A/S Page 10 of 12

Technical information 2.1.2 Dimensions and circuit diagrams Overall dimensions AEM 380 AEM 305 Overall dimensions Circuit diagrams Circuit diagrams DEIF A/S Page 11 of 12

Ordering information 3. Ordering information 3.1 Order specifications and disclaimer 3.1.1 Order specifications Type Order details AEM 380 Three phase energy meter, 80A, 2S0, 2 tariffs, MID approved. Aux. supply: 230V AC / 50Hz DEIF no. 1217010002 EAN no. 5703727110063 AEM 305 Optional interfaces Three phase energy meter, CT../5A, 2S0, 2 tariffs, MID approved, Aux. supply: 230V AC / 50Hz DEIF no. 1217010004 EAN no. 5703727110070 Modbus Interface MODBUS -Rtu/ASCII for energy and power communication. Aux. supply: 230V AC / 50Hz DEIF no. 1217030001 EAN no. 5703727110100 MBus Interface KNX Interface M-BUS for energy and power communication DEIF no. 1217030002 EAN no. 5703727110117 KNX for energy and power communication DEIF no. 1217030003 EAN no. 5703727110124 LAN Interface LAN TCP/IP server for energy and power measurements. Aux. supply: 230V AC / 50Hz DEIF no. 1217030004 EAN no. 5703727110131 SD Datalog Interface SD Power supply SD-card Data logger, 2GB SD card. Aux. Supply: 12-24V AC/DC DEIF no. 1217030006 EAN no. 5703727110148 Power supply, 12 VAC 3VA (up to 6 SD Datalog interfaces) DEIF no. 1217030007 EAN no. 5703727110155 3.1.2 Disclaimer DEIF A/S reserves the right to change any of the contents of this document without prior notice. DEIF A/S Page 12 of 12