MegaTrak MCU-9000 Harness Wiring

Similar documents
ADDENDUM FOR 20, 27, & 28 OPTIONS

Analog Input and Output Options for Syringe Pumps

THE CTB08D LIGHT CONTOLLER

CHAPTER Wi r i n g NOTICE:

Driver/Controller Development Assistance Package For IDEX Health & Science TitanHT TM Driver Board

Copy Machine Reader. Installation and Setup Guide

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

Defining the Future in Motion Control

Quick Start Installation Guide

Section 1 INTRODUCTION

Digital Lighting Systems, Inc.

716 Converter. Programmable Data Converter

Connecting a Cisco Reader Module

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

4 Connection and interface

BLU- CIF Interface Board

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

MODEL DRIVER Ic Ip VDC

Quick Start Installation Guide

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

Saab TransponderTech. INSTALLATION GUIDE J4N Junction Box for R4 Navigation System

NeXGen Controller Installation Guide for Bennett Equipment

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

PLC I/O wiring. PLC power supply cable and general control circuit wiring. Power lines. Ground to 100 Ω or less

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

BLU- CIF2 Interface Board

4 Connection and interface

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

SAB-QS Quick Start November 9, SAB-QS Quick Start SAB-QS TRANSDUCERS 1 X4. Figure 1: SAB-QS Connector and Jumper Placement

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

Digital Keypad Introduction

Suprex RS-485 SPX-7500 Wired Reader-Extender

MAXIMA + Series ROTARY LEVEL CONTROL

E-Learning, DC drives DCS800 Hardware D5 D7, part 2

CONTROL PROTOCOL Motorized Projection Screens

SMART VEND PR & PR/PD & SLIM TROUBLESHOOTING GUIDE

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

PXL-250 Tiger Controller

Blue Point Engineering

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

MaxStepper Serial Step and Direction Pulse Generator. User Manual

INSTRUCTION MANUAL. Dual-System Signal Interface

Operating Instructions Wiegand Decoder with SD Card

WIRING INSTRUCTIONS FOR HENRY SIGNS CONCERNING THE JOHN HANCOCK SIGN

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

TARA CONTROLS AGC-5. UCI Random Start USER S GUIDE. With Optional Warning Flashes for the Hearing Impaired. TARA CONTROLS by Cartessa Corporation

Installation & Operation Guide

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

Arrakis Systems 6604 Powell Street / Loveland, Colorado 80538

FX-485PC-IF RS485 Interface Unit Hardware Manual

Job Aid: Connector and Cable Diagrams (Pinout Charts)

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

FUEL MANAGEMENT SYSTEM SentryGOLD

CardMaster Installation Manual rev NE 177th Place, Woodinville, WA fax

PURE SINE WAVE INVERTER REMOTE GP-ISW-R-12/24

EFRP-x462 SERIES. Industrial Computer File Server System Raid Subsystem

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List

Lightning Stitch Assembly

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Quick Installation Guide MAC1000/MAC1000SR STANDALONE BIOMETRIC CONTROLLER

1%$6+2:7,0(*2/'(',7,21 1)/%/,7=*2/'(',7,21 &219(56,21.,7

Telephony Multi-Taps. 9000T-TP Series

Quadrature Encoder User's Manual. Specification and Installation Guide. NetLinc, TLAser400 & PTRBe. Oct 2015

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

BLU- CIF2 Interface Board

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

4.7 Expansion Module MAC00-FS1/FS4

MAXIMA + Series ROTARY LEVEL CONTROL

CHAPTER 3B: ELECTRONIC POWER STEERING

HOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA

USER S MANUAL. CNC Servo Stepper Motor Control Box CH4EV12-1 Rev. 1

Treadmill Embedded Touch Screen Won t Power Up

This document describes the procedure for doing a power trace on the SM5 and Gauntlet Stepmills.

Installing the H2 -EBC(100), H2 -EBC -F or H4 -EBC( -F)

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

Assembly Instructions scancontrol 2700/2750 (500)

RTU560 Remote Terminal Unit Connections and Settings

MS-5000: MiniStar Reader

For more details and updates go to our website, boatcommand.com.

NI SMD-7620/7621 Stepper Drives and NI 73xx Motion Controllers

MS-7000: SuperStar Reader

7I74 MANUAL 8 CHANNEL RS-422 INTERFACE

SRI-02 Speech Recognition Interface

INSTALLATION INSTRUCTIONS

MS-3000 MicroStar Reader

Installing Your 1394 Drive Interface Module

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

Topic: TB No.: Date: Aug/2017. Model UC4, UC10 & UC45 twin pump variants Regulated 24V Pump Power supply upgrade OVERVIEW

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Digital Power Probes, ACL120, ACL220, ACL Internal, and DCL5 (#30015, #30023, #30024, #30025)

2Installation CHAPTER TWO IN THIS CHAPTER. Checking Your Shipment Express Setup. Chapter 2 Installation 11

AX3000 Platine Terminal Ethernet TCP/IP

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

Trigger I/O Board for the LogiComm Gun Driver

Transcription:

MegaTrak MCU-9000 Harness Wiring Contents: 1. MCU9000 Connector Pin-Out Schematic 2. MCU9000 Connections when replacing an MCU3000 3. MCU9000 Connections Using 120VAC ( Hot ) Hook Switch (RS485 cable) 4. MCU9000 Connections Using 120VAC ( Hot ) Hook Switch (RS485 wires) 5. MCU9000 Universal Harness 6. MCU9000 Connections Using Dry Contact Hook Switch 7. MCU9000 Connections Using 12-16 VDC Truck Power 8. MCU9000 Connections for 120 VAC Bench Test Powering 9. Serial DB-9 (FML) to RJ-11 6P6C Adaptor Wiring 10. USB to RS485 Adaptor Hookup USOPTL4 11. MCU9000 Typical Pump Hookup 12. MCU9000 Pump Hookup using 120VAC Input Solid State Relay 13. MCU9000 Pump Hookup using Low Voltage Hook Switch 14. MCU9000 Wiegand Card Reader Hook-Up 15. MCU9000 ibutton Probe Hook-Up 16. MCU9000 Keri NXT Card Reader Hook-Up 17. MCU9000 Serial Mag Stripe Card Reader Hook-Up 18. Sub-Harness for MCU9000 Peripherals 19. MCU9000 Software House Wiegand Card Reader Hook-Up

P a g e 2 Pin-Out: 1 & 2 120VAC 3 Power System Earth Ground 4 & 5 Relay (Pump or Valve Control) 8A@120VAC 6 & 7 Pulser (dry contact or 5-20 VDC) FUEL FLOW PULSER (Dry Contact or DC) + 7 Note: Three contacts colored in BLACK are all COMMON GROUND 14 DATA B DATA A GROUND (SHIELD) 8 Hook switch (dry contact to ground) 9 & 10 Hook Switch (120VAC) 11 +12 VDC 12 Ground 13 Serial communications (A) (RS485) 14 Serial communications (B) (RS485) Note: If fuel pump or valve draws more than five (5) amperes, use a mechanical or SSR (solid-state relay) to control it. See Figure 12. 120 VAC FUEL PUMP NEUTRAL HOT GROUND 1 8 MOLEX 39-01-2140 w/ 44476-1112 FML pins (Looking at rear of connector) +12VDC HOT NEUTRAL DRY CONTACT HOOK SWITCH 120 VAC from HOOK SWITCH Figure 1 - MCU9000 Connector Pin-Out Schematic

Dry-Contact or DC Pulser (+) Pump Motor Or Valve Control 120VAC Mains NEUT HOT In-Line 3AG Fuse 6A @ 240VAC Not needed unless using hardwired RS485 communications 7 14 1 8 MOLEX 39-01-2140 w/ 44476-1112 FML pins (Looking at rear of connector) 120VAC Figure 2 - MCU9000 Connections when replacing an MCU3000 (Note: If the previous wiring did not use standard colors, use caution to make the correct electrical connections based on pin numbers.) P a g e 3 120VAC Hook Switch (if present)

Dry-Contact or DC Pulser In-Line 3AG Fuse 6A @ 240VAC Pump Motor Or Valve Control 120VAC Mains P a g e 4 Note: Three contacts colored in BLACK are COMMON GROUND RED DATA B BROWN 7 14 RS485 Communications Cable (optional) DATA A GROUND (SHIELD) ORANGE 1 8 GRAY PINK EARTH/GROUND GREEN MOLEX 39-01-2140 w/ 44476-1112 FML pins (Looking at rear of connector) 120VAC HOT from Hook Switch Note: Not all installations include a hook switch NEUTRAL WHITE HOT BLACK Figure 3 - MCU9000 Connections Using 120VAC ( Hot ) Hook Switch with shielded twisted pair communications cable

Dry-Contact or DC Pulser In-Line 3AG Fuse 6A @ 240VAC Pump Motor Or Valve Control 120VAC Mains P a g e 5 RED BROWN Note: Three contacts colored in BLACK are COMMON GROUND 7 14 PURPLE RS485 Communication Connections (Optional) YELLOW GREEN DATA B DATA A GROUND (SHIELD) ORANGE 1 8 GRAY PINK EARTH/GROUND GREEN MOLEX 39-01-2140 w/ 44476-1112 FML pins (Looking at rear of connector) 120VAC HOT from Hook Switch Note: Not all installations include a hook switch NEUTRAL WHITE HOT BLACK Figure 4 - MCU9000 Connections Using 120VAC ( Hot ) Hook Switch with wires for RS485 serial communications

Dry-Contact or DC Pulser In-Line 3AG Fuse 6A @ 240VAC Pump Motor Or Valve Control 120VAC Mains RED (+) BROWN (-) ORANGE GRAY EARTH/GROUND NEUTRAL WHITE HOT BLACK Note: Three contacts colored in BLACK are COMMON GROUND PURPLE 7 14 YELLOW GREEN RED/WHITE GREEN 1 8 MOLEX 39-01-2140 w/ 44476-1112 FML pins (Looking at rear of connector) PINK BLUE GRN/WHITE Note: Un-used wires MUST BE CAPPED-OFF! Figure 5 - MCU9000 Universal Harness P a g e 6 DATA B DATA A GROUND (SHIELD) +12VDC OUT/IN 120VAC HOT from Hook Switch 120VAC COMON Low Voltage or Dry Contact Hook Switch to Ground

Dry-Contact or DC Pulser In-Line 3AG Fuse 6A @ 240VAC Pump Motor Or Valve Control 120VAC Mains P a g e 7 Note: Three contacts colored in BLACK are COMMON GROUND RED DATA B BROWN 7 14 12 RS485 Communications Cable (optional) DATA A GROUND (SHIELD) ORANGE GRAY EARTH GREEN 1 8 MOLEX 39-01-2140 w/ 44476-1112 FML pins (Looking at rear of connector) Dry-Contact Hook Switch Note: Not all installations include a hook switch NEUTRAL WHITE HOT BLACK Figure 6 - MCU9000 Connections Using Dry Contact Hook Switch

Dry-Contact or DC Pulser RED BROWN 7 Note: Three contacts colored in BLACK are COMMON GROUND 14 In-Line 3AG Fuse 5 Ampere 12 Pump Motor Or Valve Control 10-16 Volts DC from Vehicle Power ORANGE GRAY GREEN(- or CHASSIS) RED/WHITE (+) 1 8 MOLEX 39-01-2140 w/ 44476-1112 FML pins (Looking at rear of connector) Figure 7 - MCU9000 Connections Using 12-16 VDC Truck Power P a g e 8 Dry-Contact Hook Switch Note: Not all installations include a hook switch

Use this adaptor to power-up the MCU-9000 for bench testing or re-programming. If MCU is set for 240 VAC operation, jumpers will need to be changed to 120 VAC settings during bench powering. 7 14 12 120 VAC Outlet USE CAUTION! 1 8 MOLEX 39-01-2140 w/ 44476-1112 FML pins (Looking at rear of connector) Figure 8 - MCU9000 Connections for 120 VAC Bench Test Powering P a g e 9

This adaptor is used to program the MCU-9000 assembly from an RS232 computer port. And RS232-to-USB adaptor may also be required if the computer is not equipped with an RS232 DB-9 serial port. Pin #1 N/C RXD Rear of DB-9 FML Connector TXD DTR N/C Figure 9 Serial DB-9 (FML) to RJ-11 6P6C Adaptor Wiring Rear of Modular RJ-11 Style 6-Pin Jack P a g e 10

Standard USB Cable Note: All four DIP switches should be set to ON position on rear of unit. USB TD ULINX TDA(-) TDB(+) RD Model USOPTL4 USB-to-RS485 Isolated Coupler USB To Computer Software USB driver comes on CD ROM with unit. Figure 10 USB to RS485 Adaptor Hookup USOPTL4 P a g e 11 To MCUs

MCU9000 Electrical Earth Ground Power Source A/C HOT PUMP MOTOR or FUEL VALVE Switched HOT Pulser 2341.5 BROWN (Common) A/C HOT 120VAC Hook Switch (if present) Figure 11 MCU9000 Typical Pump Hookup w/o Solid State Relay Register P a g e 12

MCU9000 Electrical Earth Ground Power Source A/C NEUT Solid-State Relay with 120 VAC Input A/C HOT Switched 120VAC ABB R126/25 or Equiv 25A@280VAC Pulser 2341.5 Register A/C HOT 120VAC Hook Switch (if present) Figure 12 MCU9000 Pump Hookup using 120VAC Input Solid State Relay P a g e 13 High-Current Motor Control

MCU9000 Electrical Earth Ground Power Source A/C HOT PUMP MOTOR or FUEL VALVE Switched HOT Pulser 2341.5 Register BROWN (Common) LVHSW 12VDC Hook Switch Figure 13 MCU9000 Pump Hookup using Low Voltage Hook Switch P a g e 14

P a g e 15 MCU-9000 Wiegand (HID) Connections Wiegand format card or token readers connect to the MCU-9000 using four wires. Two provide power for the reader and two are data connections. Readers may have numerous additional wires, but none of these are used at this time. These extra wires should be tied-off so that they cannot short-circuit to ground or the other wires. See the Cables and Harnesses document for more details. From +12 VDC MCUINT board +12VDC GROUND +12VDC wires must be doubled-up in this connector +12V DATA0 DATA1 From Wiegand Reader D0 D1 CPM BOARD on rear of MCU assembly These are standard wire colors for Wiegand readers. Check the reader manufacturer for wire color details. Insulate and tie-off all other un-used conductors from reader. D0 = DATA0, D1 = DATA1 Figure 14 MCU9000 Wiegand (HID) Card Reader Hook-

MCU-9000 ibutton Probe Hook-Up w/led LED(K) LED(A) Ground Rear of ibutton Probe Assembly OW Data Figure 15 MCU9000 ibutton Probe Hook-Up P a g e 16 +12VDC DATA0 DATA1 CPM BOARD on rear of MCU assembly OWD VCC LED

P a g e 17 MCU-9000 Keri NXT Series RS495 Reader Hook-Up Keri brand card readers in the NXT series use RS495 instead of Wiegand to communicate. When we use a Keri NXT reader, we wire it to unique terminals in the MCU9000 and use MPIC firmware that supports it. From +12 VDC MCUINT board +12VDC GROUND AUX1 +12VDC wires must be doubled-up in this connector AUX2 RED From Keri NXT Card Reader GREEN WHITE BLACK The shield wire should be connected together with the BLACK (ground) wire or to a chassis ground. CPM BOARD on rear of MCU assembly Figure 16 MCU9000 Keri NXT Card Reader Hook-Up

MCU-9000 Serial Mag Stripe Reader Hookup GROUND +12VDC AUX1 AUX2 SERIAL DATA POWER CPM BOARD on rear of MCU assembly POWER Figure 17 Serial Mag-Stripe Card Reader Hook-Up P a g e 18

P a g e 19 MCU-9000 Rotary Encoder Pulser Hook-Up Encoder-to-MCU Colors: Red -> Yellow (+5V) Green -> Brown (Ground) Orange -> Red (Signal) Yellow -> No Connect Electrical Installation: Disconnect and remove the old pulser assembly. Cap-off any old power wires that ran to the old pulser amplifier. The RED and BROWN wires connect to the same colored wires coming from the MCU in the wiring harness. These used to go to the old pulser amplifier. The YELLOW wire has to be run up to the MCU and connected to the 4-terminal connector on the back of the MCU assembly. BROWN RED YELLOW Yellow wire into 2 nd terminal New yellow wire running from the pulser up into to the MCU housing GROUND (BROWN) PULSER (RED) These wires are in the existing MCU harness assembly already installed Plugs onto rear of MCU Mechanical Installation: The pulser shaft connects to the once-around-per-gallon shaft on the pump register assembly. Make sure the shaft and the coupler are free to rotate 360 degrees, and the pulser case is tied so that it will not rotate. The MCU must be set for 128 pulses-per-gallon using the setup key.

P a g e 20 MCU-9000 Software House Wiegand Reader Hookup From +12 VDC MCUINT board +12VDC GROUND +12VDC wires must be doubled-up in this connector BEEP +12V D1 D0 GREEN RED 1 12 SWH-4000 or SWH-4100 Multi-card Reader (10 or 12 pin connector) D0 D1 These are standard wire colors for Wiegand readers. Check the reader manufacturer for wire color details. Insulate and tie-off all other un-used conductors from reader. D0 = DATA0, D1 = DATA1 DATA0 DATA1 CPM BOARD on rear of MCU assembly Figure 19 MCU9000 Software House Wiegand Card Reader Hook-Up