UPDATING THE SERVICE TOOL Updating the Service Tool with Prism 2

Similar documents
UPDATING THE SYSTEM MANAGER SD Updating the System Manager with Prism 2

UPDATING CONTROLLERS USING PRISM 2 Updating the VCB-X / VCC-X Controller

UPDATING CONTROLLERS USING PRISM 2 Updating the VCC-X Controller

USB-Link 2 Technical Guide

USB-Link Technical Guide

USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up

USB-Link 2 Technical Guide

USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up

CommLink IV Technical Guide

CommLink 5 Technical Guide

CommLink 5 Technical Guide

FLASH GUI. User Manual V1.4 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

IP Module Technical Guide

IP Module Technical Guide

IP Module Technical Guide

IP Module Technical Guide

IP Module Technical Guide

Dot Matrix Indicator Programming

Modular System Manager SD Quick Start Guide

Modular Service Tool SD Quick Start Guide

Graphical Interface Technical Guide

USB 2.0 Ultimate Card Reader

Import Version 4 Data into Version 8

Windows Me Plug-and-Play

Setting up the PC ready for BESA 11

Installation instructions for the PARTNER TECH PT 6215 Hardware with Corner Store POS

Moving HRtrack to a new computer

Internet Key Administration

Version S Cincinnati, Suite 105 Tulsa, OK (918) Fax (918)

Driver Installation and Computer Connection Instructions

C75/J75 Simple Image Quality Adjustment (SIQA) v2.0 Software Installation Instructions

linkzone User ManUal

Technical Information

Instructions to Upgrade Your UME-36 Pro

VISTA - CTI Multi-port Serial Adapter. Install Guide

User s Manual. Hi-Speed USB 2.0 Flash Disk

INSIGHT Installation Instructions

Flasher PC Application

Installing USB Drivers to Windows System

QUICK START GUIDE FOR FIRMWARE UPGRADE RS232-TO UART INTERFACE BOARD AND SOFTWARE

User Manual. Thermo Scientific Orion

tiptel 545/570 office tiptel 545/570 SD PC Software and Driver Installation in Windows XP/Windows 7 (32/64 Bit)

BankLink Books Clients

DP Color LCD Digital Photo Key Chain QUICK SETUP GUIDE

Introduction Features... Installation

1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically.

Graphical Interface Technical Guide

Roger D. Secura

WIFI Module setup guide

CodeLoader. Users Guide. P/N: Rev: OCT04

mce100+ getting started guide Install mce100+ The disc will run and display the below screen: Choose Install mce to continue

Scenario 1a Direct Serial Communication via a 9 Pin Serial/RS232 Port

Lab - Install Windows 7 or Vista

Please take the time now to check the contents of your package: HPS12U Print Server One CD-ROM Quick Installation Guide One power adapter

Mini USB to RS-232 Serial Adapter DB-9 Male Converter. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USBG-232MINI.

1. Installing the Drivers for Windows

Level One. User Manual V

SP LOCKER USER MANUAL. v1.0

Reno A & E, 4655 Aircenter Circle, Reno, NV (775) Release Date: February 5, 2008 All Reno A&E monitors. All versions of RaeComM.

QUICK START GUIDE PRINT MANAGER PLUS RELEASE STATION Software Shelf Computer Software. Take Control of Your Network Printing

Windows XP Software Installation Instructions GCC Elite Series Printers

Note that FLIP is an Atmel program supplied by Crossware with Atmel s permission.

USER MANUAL for USB Data Link

Setting up FT3000 and version on Windows 7. This is a step by step guide for setting up the FT3000 on a new Windows 7 or 8 PC

Windows NT Server Printer Driver Upgrade Instructions

StreetWise Partner. Version 3.0. Naztec Operations Manual. April For. Published by:

INSTALLING THE PS3 XBOX READY SOFTWARE:

UPGRADE INSTALLATION PROCEDURES

11814 South Election Rd., Suite 200, Draper, UT (801) FAX (801)

TPP Server INSTALLATION AND SET-UP

CHAPTER 17 COMPILING/SIMULATING/DOWNLOADING A PANEL APPLICATION

AN-77XX-XP 2K MCS77XX. Windows-2k & Windows-xp

Print Server Setup Guide (NF1ADV)

Generes and Associates. Desktop Setup Guide LANDTECH ONLINE

Centurion C4 Transfer Guide using C4 File Transfer Utility

M3099G\GX\GH\Fi-4860C\M4099D\Fi-4990C WinNT Installation Procedure

Tech Memo # Software Engineering. Normal PRIORITY: DATE: April 17 th, 2015

DIABLOSPORT PREDATOR REVISION UPDATE INSTRUCTIONS

Release Note - Updating Embedded NT Systems

CellSync Manager. User Manual F8V7D006-SS F8V7D008-SS. Get online and synchronize anywhere. Web Access. Phone Book Manager

Part # Quick-Start Guide. SpeedStream 4200 Modem PPPoE Modem Router

Configuring Microsoft Outlook to Connect to Hosted Exchange Service

PMP Installation and Networking Instructions

Updating LCD Firmware for WattsOn-Mark II Metering Kit HMI

QEMU Manager: Computer on a Stick

Integrated Power Management for Microsoft Windows 7, Vista, and Windows server 2008, 2012 (x86&x64)

Touchscreen Driver Release Note

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

Requirements Instructions Configuring Cat ET to use the Wireless CA3 Radio... 12

COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED

SETTING UP NETWORKING FOR LOOKOUT 4.0

Setup Instructions for Upgrading the Windows XP Panasonic CF-19 Toughbook to Windows 7

Installation of fi-4110cu Scanner under Windows 2000

Instructions for Installing FlashUpdate and Downloading Updates for NPRT 2200 Noise Power Ratio Test Set

Bridge Cable User s Guide

BEFORE INSTALLATION: Thoroughly read this document to ensure you understand how to use this product.

Digidoc Icon Camera Installation

Install New Java Client, Release GL 3.1 For Workstations Currently without Java

CompuLEAD: Installing LeadLINK Plus!

Valley Library Consortium

Transcription:

Updating the Service Tool with Prism 2 Updating the Modular Service Tool SD with Prism 2 Version 4.5.0 and higher The Modular Service Tool SD is equipped with the ability to update its software with the use of a computer. You will need the following before you begin: Modular Service Tool SD in need of an update (powered up) CommLink 5 or USB-Link 2 Computer running Microsoft Windows TM operating system Prism 2 software from www.orioncontrols.com or wattmaster.com/techsupport Latest version of the Modular Service Tool SD software (e-mailed from our tech support staff or downloaded from http://techsupport.wattmaster.com) and software sheet USB_Silicon_Labs_Setup.zip driver from http:// techsupport.wattmaster.com or from CD-ROM Modular Service Tool DIN communication cable, USB cable, and adapter Follow these simple steps to update the Modular Service Tool SD: 1. Apply power to the Service Tool SD and press the <ON> button. 2. Turn on your computer and download the latest Prism 2 software from www.orioncontrols.com. 3. Either download and unzip the Service Tool SD hex file software from http://techsupport.wattmaster. com, or if you received an e-mail from Tech Support with the file, unzip and save the file to your computer. Record the path and name of the file for later use. Also, print the software sheet provided for future reference. 4. Download the USB_Silicon_Labs_Setup driver from http://techsupport.wattmaster.com or the CD-ROM so that Prism can communicate to the Service Tool. See page 3 for instructions. 5. Plug the DIN communication cable into the Service Tool s communication port and then into the CommLink 5 or USB-Link 2 and then connect the USB-Link 2 or CommLink 5 to the computer s USB port. Make sure the USB-Link 2 and Service Tool SD are set to High Speed and Stand-Alone. To connect the Service Tool to the CommLink 5, you will need to use the adapter that was supplied with your Service Tool. See Figures 1 & 2, pages 6-7. 6. Open Prism 2 and Login with the User Name admin and password admin. If successful, Administrator Access will appear at the lower right of the Prism program. 7. Click on the <Job-Site> icon. The Job-Sites Window will appear. In the Type of CommLink Dialog Box, select CommLink 5 or USB Link II. 8. In the Job-Sites Window, from the Serial Port drop down list, select the USB to UART Bridge Controller COM port. If you don t know the COM port number or if the number is 10 or higher, follow the directions on pages 4 & 5. 9, From Prism 2 s Communications tab, select Flash Selected Controller. And from the list select Main Controllers. Modular Service Tool SD 1

Updating the Modular Service Tool SD 10. The Flash Main Controller Window will appear. 11. Step #1: In the Loop and Unit fields, enter 1 for the Loop and 62 for the Unit. 12. Step #2: In the HEX File field, type in the path and name of the HEX file you downloaded and/or copied to your hard drive or click the <Select File> button to search for the file. 13 Step #3: Click on the <Program HEX> button. 14. Step #4: If successful, you should see the HEX File Progress bar showing the progress percentage. 15. Step #5: When the Progress Bar reaches 100%, the update should be complete. 16. You can verify the correct version of software in the Service Tool LCD display. 2 Modular Service Tool SD

USB Driver Installation USB Serial Converter and Serial Port Driver Installation 7. Double-click the WattMaster USB Drivers folder and then double-click the USBInstaller.exe program. Then double-click on the file USB Driver Setup.exe. 1. Insert the USB Driver CD-ROM into your CD-ROM drive or download the USB Driver software file from www.techsupport.wattmaster.com. If using the CD- ROM, go to Step 7. If downloading the file, double-click on the link USB Driver Setup.zip file for installing USB drivers for all WattMaster Products. 8. The following window will pop up: 2. Click <Open> when asked to save or open the file. 3. Extract and run (double-click) USB Driver Setup.exe. 4. Once you unzip the file, the WattMaster USB Driver Installation Window will appear. Click <Install>. This will unzip the driver installation files to C:\Temp\ Wattmaster USB Drivers. 9. Click <Begin Install> and the installation program will walk you through the rest of the steps. The program might prompt you to remove old USB drivers from your computer. Click <Yes> if so. Once installation is complete, you will need to reboot your computer to have the new settings take effect. 10. With successful USB driver installation, you can now connect your USB device. 5. Click your <Start> button and then click, <Computer>. 6. Double-click Local Disk (C:). Then double-click the Temp folder. Modular Service Tool SD 3

Updating the Modular Service Tool SD Finding What COM Port Number the CommLink or USB-Link is Using 5. Click on the plus sign next to Ports to see all of the common ports. 1. Left-click on <Start>, located on the bottom left of the Windows Tool Bar. 2. Select <Control Panel>. 3. Double-click the System Icon. 4. Click the <Hardware> tab and then click the <Device Manager> button. 6. Locate the USB Serial Port (COM#). The COM# in parentheses is the port it is located on. Write this COM port number down. You will need to know this when setting up the Prism software. 7. If the COM port number is 10 or greater, go to Changing the USB COM Port Number on page 5. 4 Modular Service Tool SD

Updating the Modular Service Tool SD Changing the USB COM Port Number When the CommLink or USB-Link is first plugged in, it will be assigned a COM port number to be used for communicating with the Prism software. If the port number is 10 or greater, it needs to be changed to a value less than 10 to be recognized by Prism. 4. To assign a port number less than 10, click on <Advanced>. The Advanced Settings Window will appear. 1. Click <Start>, click <Control Panel>, click <System>, click the <Hardware> tab, and then click <Device Manager> to get to the Device Manager Window. 2. Click on the plus sign next to Ports to see all of the COM ports. 5. In the COM Port Number drop box, select which COM port you wish to use. Make sure you select a COM port number that is not currently in use (you can see the ports in use in the Device Manager Window). Select a port that is less than 10. NOTE: Windows will assign a port number to every device that has ever been installed on your computer. So if there are no available ports below 10, choose a port number less than 10 for a device listed that you know you are not currently using. 3. Right-click on USB Serial Port (COM#) and select <Properties>. In the Properties Window, select the <Port Settings> tab. 6. Once you select the correct COM port number, click <OK> and close any windows opened in the process of changing the port number. Make note of this number because you will need it for your Prism setup. Modular Service Tool SD 5

STAND ALONE NETWORK UPDATING THE SERVICE TOOL Modular Service Tool SD With USB-Link 2 Connection Mini-DIN Cable Supplied With USB-Link 2 And Modular Service Tool SD Modular Service Tool SD Connect Mini-DIN Cable End To Mini-DIN Port On USB-Link. USB-Link 2 Computer With Prism 2 Software Installed Communication Speed Switch Must Be Set To High Speed Configuration Switch Must Be Set To Stand Alone Connect Type B Cable End To USB Port On USB-Link 2. USB Cable Supplied With USB-Link 2 Connect Type A Cable End To USB Port On Desktop Or Laptop Computer. NOTE: USB Drivers Supplied With The USB-Link 2 Must Be Installed On Your Computer Before USB-Link 2 Can Be Used. Figure 1: Modular Service Tool SD With USB-Link 2 Connection 6 Modular Service Tool SD

Modular Service Tool SD With CommLink 5 Connection Mini-DIN Cable Supplied With USB-Link And Modular Service Tool SD Modular Service Tool SD Connect Mini-DIN Cable End To PL101904 Adapter. Computer With Prism 2 Software Installed Back of CommLink 5 Set Baud Rate Switch To High PL101904 Adapter Supplied With Service Tool. Connect to To RS485 Communication Bus On CommLink 5. MULTIPLE SINGLE HIGH LOW R (+) SHLD T(-) GND 24V SERIAL # LOOP BAUD Set Loop Switch To Single Connect Type B Cable End To USB Port On CommLink 5. USB Cable Supplied With CommLink 5. Connect Type A Cable End To USB Port On Desktop Or Laptop Computer. NOTE: USB Drivers Supplied With The CommLink 5 Must Be Installed On Your Computer Before CommLink 5 Can Be Used. Figure 2: Modular Service Tool SD With CommLink 5 Connection Modular Service Tool SD 7

Form: OR-STSDBOOT-TGD-01B Printed in the USA March 2017 All rights reserved. Copyright 2017 WattMaster Controls Inc. 8500 NW River Park Drive Parkville, MO 64152 Phone: 866-918-1100 www.orioncontrols.com Fax (816) 505-1101