B63/ NS MS. EtherNet/IP LINK

Similar documents
B61/ LTU350/1 SE352M LTU350/1 SE352 INT EXIT. Reset. Reset. Reset XDN2 X1S2 VM350

Mobile Particle Counter

Installation manual plugs and connectors with screw connection (16/32 A)

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

SolConeX extra-low voltage flange socket

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

User Manual. Printer P-52RUE

ETAM3 XETK/FETK ECU Adapter, SAMTEC FFSD - SAMTEC SFM (10fc - 10fc), 0m11 User s Guide

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating instructions IO-Link master CabinetLine AL19xx

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

* * Agilent Power Distribution Unit (PDU) Installation Guide

Serial PROFIBUS Interface

CNVT-USB-RS485 MODBUS TO USB CONVERTER. Operating instructions

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

Operating instructions. Switching amplifier DN0210 DN / / 2015

PX Series Balances. Quick Start Guide. Please download the user manual from

INSTALLATION INSTRUCTIONS 07/2018

CPCI-PS24 24V-Power Supply

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

MANUAL. Document Version 1.0/March LOGIClink

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

WA4204-G2/G3 and WA4304-G2/G3

User Manual Gateway component for EtherNet/IP

MDM 011-Z1 Regen Resistor

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

1. Safety Precautions (Read these precautions before use.)

E65C CU-E20, E22. User Manual. Communication Industrial and Commercial

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Operating instructions. Speed monitor D / / 2014

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

Deckblatt von Marketing / Foto fehlt

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

CMC III Temperature/Humidity Sensor

Technical Manual Room temperature controller

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Mounting and Operating Instructions EB EN. Electric Actuators Type 5824 without fail-safe action Type 5825 with fail-safe action

MINI MCR-SL-MUX-V8-FLK 16

CMC III Universal Sensor

BK MIKRO. Air Barrier Adapter. Assembly Instructions Issue 1.00 dated

ISG Isolated DIN Rail Mount Signal Conditioner Issue: Revision A Technical User Manual

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Explosion proof UL certified VoIP telephone. FernTel IP Z2 UL. Tabletop unit. Manual FHF BA /12

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Expansion module EM-BAC-MOD-01. Installation manual

Powerline Adapter Set

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

Channel Switch CS. General Operating, Maintenance and Installation Manual

icore Kiosk system Installation Guide

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

TVAC25100 TVAC25110 User manual

RТTH DUAL ROOM SWITCH

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

PRODUCT MARKING AND BARCODE IDENTIFICATION. up to Serial No Barcode/Label printer MACH4. Service Manual. Edition 11/06

2260B-RMK-Series Rack Mount Kit

Installation Job Aid for Ethernet Routing Switch 3600 Series

Cube LAN Gateway. Operating manual BC-LGW-O-TW

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

Agilent 70612B K18 Switch Matrix

Daily use. indicating that the loud speakers

Installation Job Aid for VSP 4850GTS

a:touch Universal control panel for Allen thermal transfer printers OPERATING INSTRUCTIONS

Operating Manual FPGA-based High-Speed Micro-PLC

HST -S1 Switching element (Translation of Original Manual)

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

PTZ Control VMC Joystick

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

Temposonics Magnetostrictive Linear Position Sensors

Flow Sensor SONOFLOW CO.55

Demo Kit Quick Start Guide

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Accessory GP-EXT. EXTERNAL USB PRINTER User's Manual

Troubleshooting Manual

MODEL C-HOMWA-1 CONNECTIVITY KIT, CONNEX (USB)

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

MANUAL. Document Version 1.0/March SLIMdrive-500

UTAH-100/XHDA SERIES

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Perle MCR200 Installation Guide

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

Operating Manual. Guardian Series Safety Compliant Melt Pressure Transducer

HV-CS kv Edge Mount Triaxial Jack

Transcription:

3 609 929 B63/ IMenip 2008-09 NS MS EtherNet/IP LINK

3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 15/76 Table of Contents About this document................. 16 General safety instructions............ 16 Delivery contents.................... 18 Product description.................. 18 Transport and storage................ 20 Assembly.......................... 20 Commissioning..................... 22 Operation.......................... 22 Maintenance and repair............... 22 Decommissioning................... 22 Disassembly and replacement......... 23 Disposal........................... 24 Extension and conversion............. 24 Troubleshooting..................... 24 Technical data...................... 25 Service and sales.................... 26 The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. This document was written in German. ENGLISH ENGLISH SVENSKA PORTUGUÊS ESPAÑOL ITALIANO FRANÇAIS

16/76 Bosch Rexroth AG IMenip 3 609 929 B63/2008-09 1 About this document This manual contains important information on the safe and appropriate assembly, transportation, commissioning, operation, maintenance, disassembly and simple troubleshooting of the IMenip interface module. Read these instructions completely, especially the chapter 2 General safety instructions on page 16 before working with the IMenip interface module. Related documents The IMenip interface module is a system component. Also observe the instructions for the other system components. Also observe the generally applicable, legal or otherwise binding regulations of the European or national legislation and the rules for the prevention of accidents and for environmental protection applicable in your country. 2 General safety instructions The IMenip interface module has been manufactured according to the accepted rules of current technology. There is, however, still a danger of personal injury or damage to equipment if the following general safety instructions and the warnings before the steps contained in these instructions are not complied with. Read these instructions completely and thoroughly before working with the IMenip interface module. Keep these instructions in a location where they are accessible to all users at all times. Always include the operating instructions when you pass the IMenip interface module on to third parties. Intended use The IMenip interface module is a component in terms of the machine directive 98/37/EC and is not a ready-for-use machine. The product is exclusively intended for being integrated in a machine or system or for being assembled with other components to form a machine or system. The product may be commissioned only if it is integrated in the machine/system for which it is designed and the machine/system fully complies with the EC machine directive. Observe the operating conditions and performance limits specified in the technical data. The IMenip interface module is a work appliance and not designed for private use. Intended use includes having read and understood these instructions, especially the chapter 2 General safety instructions. The IMenip interface module is intended for installation in components for the Tightening System 350. Improper use Any use of the IMenip interface module other than described in chapter Intended use is considered as improper. Personnel qualifications Assembly, commissioning and operation, disassembly, service (including maintenance and repair) require basic electrical and mechanical knowledge, as well as knowledge of the appropriate technical terms. In order to ensure operating safety, these activities may therefore only be carried out by qualified technical personnel or an instructed person under the direction and supervision of qualified personnel.

3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 17/76 Qualified personnel are those who can recognize possible hazards and institute the appropriate safety measures due to their professional training, knowledge, and experience as well as their understanding of the relevant conditions pertaining to the work to be done. Qualified personnel must observe the rules relevant to the subject area. Safety instructions in this document In this manual, there are safety instructions before the steps whenever there is a danger of personal injury or damage to the equipment. The measures described to avoid these hazards must be observed. Safety instructions are set out as follows: SIGNAL WORD Type of RISK! Consequences Precautions Safety sign (warning triangle): draws attention to the risk Signal word: identifies the degree of hazard Type of risk: identifies the type or source of the hazard Consequences: describes what occurs when the safety instructions are not complied with Precautions: states how the hazard can be avoided This warning symbol cautions against dangers to your health. Observe all the safety instructions that follow this symbol to avoid possible injuries or death. This warning symbol cautions against dangers to your health caused by electrical voltage or currents. Observe all the safety instructions that follow this symbol to avoid possible injuries or death. The signal words have the following meaning: CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury or damage to equipment. Adhere to the following instructions General safety instructions Only accessories and add-on units that have been approved for use in Rexroth tightening systems may be used therein. Non-approved components may neither be added nor connected to the system. The same applies to cables and lines which belong to the Rexroth tightening system. Otherwise, functional and system safety is jeopardized. Observe the regulations for accident prevention and environmental protection for the country where the product is used and at the workplace. Exclusively use Rexroth products in good technical order and condition. Check the product for visible defects, for example damage to the circuit board, components, housing, and plug connectors or missing screws. ENGLISH ENGLISH SVENSKA PORTUGUÊS ESPAÑOL ITALIANO FRANÇAIS

18/76 Bosch Rexroth AG IMenip 3 609 929 B63/2008-09 Only use the product within the performance range provided in the technical data. Persons who assemble, operate, disassemble or maintain Rexroth products must not consume any alcohol, drugs or pharmaceuticals that may affect their ability to respond. The warranty only applies to the delivered configuration. The warranty will not apply if the product is incorrectly assembled or handled or not used as intended. Do not expose the product to any mechanical loads under any circumstances. Do not place any objects on it. During assembly Make sure the relevant system component is not under pressure or voltage before assembling the product or when connecting and disconnecting plugs. Protect the system against being switched on. Lay cables and lines so that they cannot be damaged, are in accordance with the bending radiuses, and no one can trip over them. Before commissioning, make sure that all the plug connectors are installed correctly, undamaged, and that all screws are tightened. During commissioning Let the product acclimate itself for several hours before commissioning, otherwise water may condense in the housing. Make sure that all electrical connections are either used or covered. Commission the product only if it is installed completely. Never use solvents or aggressive detergents. Only clean the product using a slightly damp, lint-free cloth. Only use water to do this and, if necessary, a mild detergent. Disposal Dispose of the product in accordance with the currently applicable national regulations in your country. 3 Delivery contents The delivery contents include: 1 IMenip interface module 1 instruction manual for the IMenip interface module 4 Product description Performance description A tightening system is controlled by this interface. It can transfer cyclic I/O data. The IMenip interface module is directly supplied with power via the components in the System 350. During cleaning Cover all openings with the appropriate protective equipment in order to prevent detergents from penetrating the system.

3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 19/76 Device description Transfer rates of 10 MBit/s or 100 MBit/s are supported. Suitable connection plugs Use connection plugs in accordance with standard IEC 61158. 1 2 3 4 Display elements The NS LED indicates the Ethernet status. Table 2 NS NS Fig. 1: IMenip interface module, front view (socket) 1 NS LED (network status) 2 Ethernet interface 3 LINK LED (connection/activity) 4 MS LED (module status) 5 Screws Interface connection assignment The interface has an 8-pin RJ45 socket design. Table 1 MS LINK Pin Signal Description/function 1 Transmit + Ethernet transmission cable 2 Transmit Ethernet transmission cable 3 Receive + Ethernet reception cable 4 NC 5 NC 6 Receive Ethernet reception cable 7 NC 8 NC 5 LED display Off Green Flashing green Red Flashing red Meaning No voltage, not initialized or invalid IP address Online, one or more connections to master established (CIP class 1 or 3), ready for operation Online, no connection to master established Double IP address or blocking error Timeout reached in one or more connections (CIP class 1 or 3) The LINK LED indicates the connection or activity via Ethernet. Table 3 LINK LED display Off Green Flashing green Meaning No connection, no activity Connection established, ready for operation Connection/activity ENGLISH ENGLISH SVENSKA PORTUGUÊS ESPAÑOL ITALIANO FRANÇAIS

20/76 Bosch Rexroth AG IMenip 3 609 929 B63/2008-09 The MS LED indicates the interface module status. Table 4 MS LED display Off Green Flashing green Red Flashing red Meaning No voltage or not initialized Module controlled by a scanner during operation Not configured or scanner in idle mode Error (exception error or blocking error) Self-acknowledged error 5 Transport and storage For storing and transporting the product always observe the ambient conditions specified in the technical data (see Technical data on page 25). Assembling the IMenip interface module CAUTION Risk of damage to persons and property! Assembly of the IMenip interface module requires basic mechanical and electrical knowledge. y Only qualified personnel (see Personnel qualifications on page 16) are authorized to assemble the IMenip interface module. y Measures to prevent electrostatic discharge (ESD protection) must be undertaken to protect the module and system components during all assembly work. CAUTION 6 Assembly When installing the product always observe the ambient conditions specified in the technical data (see Technical data on page 25). Required tools TX9 screwdriver Risk of injuries when assembling under voltage! If you do not switch off the power supply before assembling the IMenip interface module, you may get injured or the device or system components may be damaged. y Always switch off the power supply to the relevant system component before assembling the IMenip interface module.

3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 21/76 1. Always switch off the power supply to the relevant system component before assembling the IMenip interface module. 2. Insert the IMenip interface module into the appropriate slot on the system component until it catches (example in Fig. 2). 3. Tighten the torx screws on the front until the front panel is flush. The circuit board is locked by turning the screw. This lock is only fully functional once the interface has been properly tightened (see Fig. 3). ENGLISH Fig. 2: Example: Inserting the interface module ENGLISH Fig. 3: Lock effect 1 Lock 1 SVENSKA PORTUGUÊS ESPAÑOL ITALIANO FRANÇAIS

22/76 Bosch Rexroth AG IMenip 3 609 929 B63/2008-09 7 Commissioning CAUTION Risk of damage to persons and property! Commissioning of the IMenip interface module requires basic mechanical and electrical knowledge. y Only qualified personnel (see Personnel qualifications on page 16) are authorized to commission the system. Before commissioning, check that all plug-in connections have the correct seat. Once the system has been switched on and the module has been initialized, it is then ready for communication on the network and waits to be connected by the Ethernet IP scanner. The NS LED and MS LED run through a test sequence following system boot up. The ESD file (device master data) corresponding to the interface module can be created with the BS350 operating software. 9 Maintenance and repair Cleaning and care Maintenance CAUTION Any dirt or liquids penetrating the device lead to malfunctions! Safe function of the IMenip interface module is no longer ensured. y Always provide for absolute cleanness when working on the IMenip interface module. The IMenip interface module is maintenancefree if used as intended. Spare parts Please refer to the address directory under www.boschrexroth.com and in chapter 16 Service and sales on page 26 for the addresses of our foreign subsidiaries. 8 Operation Operation is not necessary while the system is running. 10 Decommissioning For details about how to disassemble or replace your IMenip interface module please refer to chapter 11 Disassembly and replacement on page 23.

3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 23/76 11 Disassembly and replacement Required tools TX9 screwdriver Proceed as follows to disassemble the IMenip interface module: Disassembling CAUTION Disconnecting the IMenip interface module while under voltage Damage to the IMenip interface module! y Always switch off the power supply to the relevant system component before removing the IMenip interface module. 1. Make sure the relevant system components are not under voltage. 2. Loosen the front torx screws. The IMenip interface module may only be removed once the lock has been completely released (see Fig. 4). 3. Assemble a dummy panel, if necessary. ENGLISH ENGLISH Fig. 4: Releasing the lock 1 Lock 1 SVENSKA PORTUGUÊS ESPAÑOL ITALIANO FRANÇAIS

24/76 Bosch Rexroth AG IMenip 3 609 929 B63/2008-09 12 Disposal Environmental protection Careless disposal of the IMenip interface module could lead to pollution of the environment. Therefore dispose of the device in accordance with the currently applicable regulations in your country. You can also send the device to Bosch Rexroth for disposal. 13 Extension and conversion Do not convert the IMenip interface module. 14 Troubleshooting Malfunctions and information on errors are displayed in the tightening system, e.g. in the BS350. The NS LED indicates the Ethernet status. Table 5 NS LED display Red Flashing red Meaning Double IP address or blocking error Timeout reached in one or more connections (CIP class 1 or 3) The MS LED indicates the interface module status. Table 6 MS LED display Red Flashing red Meaning Error (exception error or blocking error) Self-acknowledged error If you should not be able to remedy an occurring defect, please contact one of the addresses that you can find under www.boschrexroth.com or in the address directory in chapter 16 Service and sales on page 26.

3 609 929 B63/2008-09 IMenip Bosch Rexroth AG 25/76 15 Technical data Table 7 General data IMenip Order number 0 608 830 271 Dimensions (width x height x depth) 50.1 x 22.3 x 56.8 mm Weight 30 g Operating temperature range Designed for operation in System 350 components Storage temperature range 20 C to 70 C Permissible humidity for application 20% - 90%, non-condensing Permissible humidity for storage 20-95% Protection class in acc. with EN 60529/IEC529 IP 20 (~NEMA 1) when installed Mounting orientation Any ENGLISH SVENSKA PORTUGUÊS ESPAÑOL ITALIANO FRANÇAIS ENGLISH