Forté Technology, Inc. World leaders in moisture measurement

Similar documents
GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

ACL 350 Digital Static Locator

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Relay Contact Output Modules

D-Pack 6 Classic ORDERCODE 50315

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

ZLS Corporation. ZLS Dynamic Meter for Marine Applications EXCELLENCE IN GRAVITY METERS. ZLS Dynamic Meter. Applications

Product Overview. System Overview

INSTRUCTION MANUAL HBPH DIFFERENTIAL 2-WIRE (4-20 ma) ph Sensor

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

CerePlex A. Instructions for Use. 630 Komas Drive Suite 200. Salt Lake City UT USA P F

EPS Power Supply

C-Rover Transmissometer

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

MODEL 245 / 345 DigiComp

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

STEP 1 Jumper Settings

4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part #

It s a Better Way to Weigh!

ENCORE /ST G4. Processor Upgrade Card for Power Mac G4 AGP Graphics. Quick Start Guide for Encore/ST G4

High Pressure E/P Regulator. ITVH Series

Input Power Selector Switch. Product Manual (Revision NEW) Original Instructions for use with Generator Set Control Assembly

VenScan LMS. Inline moisture measurement system for web-shaped materials (decorative papers, finish foils, overlays, underlays, laminates)

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Extended Range IR Illuminator Operator Manual

RibEye Multi-Point Deflection Measurement System 3-Axis Version for the SIDIIs ATD Hardware Manual for Model January 2010

MultiTherm Shaker. Operations Manual Item: H5000-H and H5000-HC

CONGRATULATIONS ON YOUR CHOICE

TD2100 Electric Gummed Tape Dispenser Owner s Manual

American Weigh Scales H-110. User Manual. H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4.

Operation Instruction for CNI Model with PSU-III-LCD

Antenna Distributor ORDERCODE D1444

FCS-30/60/150 kg (3 DIFFRENT SCALES) Shipping scale

Wiring Instructions for Replacement of 2301A Load Sharing and Speed Controls with 2301D Load Sharing and Speed Controls

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Dell MD1280 Storage Enclosure Getting Started Guide

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

LASER PLUS OPERATING INSTRUCTIONS

PAGE 1/6 ISSUE SERIES Micro-SPDT PART NUMBER R516 X3X 10X R 516 _ 1 0 _

Model 2380 Rack-Mount Kit

S82S (3/7.5-W Models)

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Application Note (Revision NEW) Original Instructions. EGCP-2 Differences

This application note is written for a reader that is familiar with Ethernet hardware design.

INSTALLATION AND OPERATING MANUAL BERTAN SERIES 602C, 603C, 605C, 606C, 612C

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

LCU-2S Liquid Supply System User Manual English

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

OPERATIONS MANUAL ACL 350 DIGITAL STATIC LOCATOR

User Manual GBS-1269BT. Body Scale 4.0. version:1.0. Distributed by: Informed Clinical Sciences Corporation 1 Joy Street, Boston, USA MA 02108

Compact data logger offering best-in-class noise resistance and communication function

2015 SIMMCONN LABS, LLC. All rights reserved. NewScope-T1 Operation Manual

CONTENTS. 1. Preface Features Technical Specifications Application of Dummy Plate Usage of Connector & Roller...

Service Instructions. Conductor 420

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

AUTOMATION. Operator s Manual. PG5 Digital Pressure Gauge

ECHO AIO TEST INTERFACE

Model 7705 Control Module

Fully-Automated Multi-Function Electrical Safety Compliance Analyzers

GM-200 HYDROMETER INTRODUCTION TECHNICAL DETAILS

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444

AS Channels Capacitive Touch Sensor IC From Santa Clara, United States of America

! User Manual Rev. 1

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Application Note (Revision NEW) Original Instructions. Wiring Instructions for 2301A Controls Replacing Caterpillar 2301 Controls

V /06/ Velleman nv

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Power Supply and Fan Module Installation

Using solderless breadboards

DCM Digital Control Modules

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

P2-04DA Analog Output. Removable Terminal Block Specifications

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Assembly Instructions

Observatory Automation Project

CSS1 Contractor Series Light Sources and CSM1 Contractor Series Optical Power Meters User s Guide

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Single Kernel Grain Moisture Tester PQ-520. (type PQ ) Operating Instructions

SATA II HDD Canister KISS DA 435 Quick Reference Guide

PV Module Installation Instructions

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz Product Overview

Characteristics and functioning

Car air purifier USER S GUIDE ver. 1.0 EN

700 Series 200 Amp Clamp Meters

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

GM-200 HYDROMETER INTRODUCTION TECHNICAL DETAILS

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

Keysight M8000 Series BER Test Solutions

Answers to Chapter 2 Review Questions. 2. To convert controller signals into external signals that are used to control the machine or process

NIR Moisture Analyzer KB-30

Installation and Operation Back-UPS Pro BR700G-TW

Transcription:

Forté Technology, Inc.

Company History 1956 - Established to measure moisture in cashmere. 1965 - Expanded into pulp industry. 2008 - Facility moved to Taunton, MA. Present - Serving clients worldwide in over 40 countries. Experienced in a wide variety of applications including: Pulp Textiles Tobacco Food Rubber More

Why Measure Moisture? Quality Control An even moisture distribution can help prevent sheet breaks. Ensure that your customers are shipped pulp that meets their needs. Increased Profits Your customers will never complain if the pulp you sell is dryer than expected. They will complain, however, if it is too wet. If you never get customer complaints, chances are, you are giving away pulp. Accurate moisture measurement can increase profits!

Functions Lead to Increased Profit Accurate Invoice Weights allow precise billing so you can invoice every kilogram of pulp that you ship. Real time measurements allow adjustments to be made within minutes instead of hours. Reduce energy costs by not over drying. Reduce sample collecting and testing which corresponds to reduced operations labor.

Other Benefits of the Forté System 1. Instantaneous, non-destructive measurement test. 2. Automated testing with minimal human interface. 3. 100% of product tested for accurate determination of Invoice Weight. 4. A reliable solution for delivering more consistent bales to customers. 5. Provides archived data for identifying changes in moisture over time. 6. User friendly and configurable.

Forté Series 8760 Functions Calculates Moisture, Air-dry, and Invoice Weight for every bale produced. Builds units and lots to track production. Assigns bale serial numbers and lot numbers. Tracks bale origin and designates count. Records gross and net weights of each bale. Provides production reports, graphs and data for trend reports that can be analyzed for future production control.

F r =k/(lc) 1/2 Principle of Operation C = kaε/d k 1 = proportional constant L = tank circuit inductance C = tank circuit capacitance F r = Resonant Frequency Fixed values k 2 = proportional constant A = area of smaller plate d = distance between plates ε = dielectric constant Bale moisture is determined by the change in resonant frequency (F r ). The resonant frequency changes based on the dielectric constant of the bale. Water has a high dielectric constant of about 80. A dry bale of pulp has a dielectric constant of about 2-7. The electrode in the press constitutes a portion of the tank circuit capacitance. Forte electronics create a non-destructive RF field. The different dielectric constants create a shift in the resonant frequency. Two frequency readings are taken. The first reading is taken when the bale is slightly compressed. The second reading is taken after the bale has been compressed 4 inches (101.6 mm) more than the first reading. The second reading is subtracted from the first reading, obtaining the Forté number. This two step method reduces the effects of oscillator drift. The Forté number can be correlated into a moisture reading with these equations and several lab air-dry data points determined by oven tests.

Forté 8760 Hardware Bale Press Electronics Forté Main Console* 1. Pulp Oscillator 1. Industrial Computer 2. Electrode/Cover plate assembly with Bleeder Resistor 3. Photo Control unit 4. Vane (customer supplied) 5. Photo Reset Switch with reflector 6. Remote Power Supply 2. DC Power Supply 3. Rack with Opto-isolated Discrete I/O Modules 4. I/O Connectors 5. Communication Interface 6. Uninterruptable Power Supply (UPS) *Items can be supplied in a console or separately. If separately, industrial computer needs to be kept in a control room.

Forté Main Console

Forté Main Console - Components 1. Industrial Computer 2. Uninterruptible Power Supply 3. Communications Interface with DC power supply and Opto rack with modules 4. I/O Connectors 5. LCD Display 6. Rocket Port Interface

Bale Press Electronics BLEEDER RESISTOR REMOTE POWER SUPPLY

Typical Bale Press Oscillator Signal Generator Passes the signal through the entire bale Reflects beam of photo switch Electrode Reflector Photo switch Resets the software so it is ready for the next bale when the beam is broken

Typical Bale Press Accepts and transmits the 2 frequency readings Photo Control Unit Vane (supplied by customer) Triggers 2 frequency readings to be taken.

Typical Bale Press Oscillator Bleeder Resistor Signal Generator Discharges any stored up potential energy

Remote Power Supply Supplies voltage to other Forté Equipment.

Industrial Computer Components Windows XP Professional operating system Dual hard drives - RAID 1 AC5 Interface Card Rocket Port Interface Card Optional Analog Interface

Rocket Port Interface - RS232/RS422

Features of the Forte Software Application Easy to learn and use. Familiar Windows pull down menus. User definable fields. Configurable summaries, reports, screen displays. Several methods of output to mill-wide information system. Utilizes SQL databases. Archives bale and measurement data for two years. Remote displays available. Optional input of Quality data. System log for ease of troubleshooting.

Mill Interface Product information transferred manually or automatically Drop information Moisture Weight Data transfer Bale Stenciler Control Room

Main Application

Schematic View of Measuring Window User configurable display includes Stock, Bale and Lot data.

Console View of Measuring Window Optional view includes large number displays for ease of viewing.

Summary Window Displays user configurable bale and measurement data.

Stock Operations Define Stocks. Assign calibrations. Enter Tare Weights. Define %AD and weight cautions and limits for a digital ouput.

Defaults Enter default data in the event that communication is lost.

Calibration Purpose - As with any secondary measurement, the Forte system requires calibration. This is necessary to convert the Forte number to an accurate Air-Dry. How - The Forte is calibrated using the oven dry method. Importance The better the oven-dry data, the more accurate the moisture, air-dry reading determined by the Forté system.

Proper Calibration - Samples Product - Collect samples from standard bale production. - Low, medium, and high moisture levels. - Use new bales that are the same size. Quantity - At least 10 bales (preferably from different bale positions). - 5-10 samples per bale (including the outside and center while avoiding the top layer and edges).

Proper Calibration - Procedure Method - Record Forté Number and Bale Weight for each sample bale. - Perform standard lab oven-dry tests. - Enter Forté Number, Bale Weight, and Air-Dry into Forté calibration program. Type - Each material requires a separate calibration. (Example: hardwood, softwood) - Calibrations are saved on the hard drive by the Forté software.

Input lab data for each sample. Calibration Calibration coefficients are automatically calculated or can be entered manually.

Calibration - Recommendation The Forté engineer will help with the initial calibration during the system installation. Forté recommends two calibration samples be collected every month for the first year to verify that the calibration continues to be accurate. After the first year, a verification calibration once a year is sufficient. The additional samples added to the calibration, reduce the standard deviation, ensuring the most accurate moisture content readings.

% Air-Dry Graph across a Drop This graph displays a drop of twelve bales. This can be used by the Wet End operator to control the dryer and prevent sheet breaks.

% Air-Dry Graph by Bale Position and Drop This carpet graph displays several drops

Trends by Drop Position The last 300 bales are displayed by drop position. This allows the user to view trends in moisture or weight both horizontally and vertically across the pulp web.

Devices View the status of connected devices.

Alarm The on screen alarm alerts the user to any system malfunction or, optionally, the alarm will display if bale weight or %AD exceeds the defined limits.

Security Standard operation does not require anyone to be logged into the system. There are 5 windows that require a user to be logged on in order to access restricted areas. There are 9 different access levels. The Forté system automatically logs every user off after 15 minutes to help prevent unauthorized changes to the Forté system. A user with sufficient access needs to be logged on in order to shut down the Forté system.

Maintenance Electrode and cover plate should be cleaned with ammonium chloride or isopropyl alcohol at least once a year, more often if hydraulic fluid and grease are prevalent at bale press. Reset photo switch and reflector need to be kept aligned and free from contaminates. Inspect all external cables and ground connections for wear and abuse. Clean the conveyor passageway through the test cell, removing stray pieces of product and wrapper material.

Troubleshooting The first place to look if a problem arises is in the System Info Log. This Log shows all of the steps the system has gone through, and any warnings that have occurred. The log may help determine the cause of the problem.

Troubleshooting If the System info log does not go back far enough, or the Forté software will not boot up at all, go into the ASCII Log. The ASCII Log can be found in C:\ForteSystem\Realtime\ASCIIlog. The ASCII Log goes back further than the Systems log to help determine the root cause of a problem.

Recommendations Shut the program and computer down properly, do not just power off or the Forte databases may become corrupted. If the B value in the calibration needs to be adjusted frequently, there may be another problem. Check to see if the electrode needs to be cleaned. Wipe down the photo switch, reflector, and sides of electrode every couple of weeks. Create back ups.

Are you using all of the features the Forté system offers? 1. Production data input to Forté manually or via barcode, ethernet, etc. 2. Output of Forté data to a remote database through a shared file (text or Excel) or through ODBC interface. 3. Output of data to existing stenciller device. 4. Output to remote display or external alarm. 5. SQL database for process control. FORTÉ SAVES YOU TIME & MONEY BY PROVIDING A RELIABLE SOLUTION FOR FULLY INTEGRATING MOISTURE MEASUREMENT INTO YOUR PRODUCTION AND SALES PROCESSES.

Forté Technology, Inc. Contact Information Forté Technology, Inc. 125 John Hancock Road Suite 9 Taunton, MA 02780 Phone: 1-508-802-9634 Fax: 1-508-824-2085 Web: www.forte-tec.com Email: info@forte-tec.com