Application Note: Using VIVOTEK Fisheye Cameras with Milestone XProtect For Plugin rev. 3.0

Similar documents
iviewer Monitoring Application for ipad, ipod,and iphone

Monitoring Application for ipad, ipod, iphone and Android phones and tablets

User Guide. VIVOCloud. Cloud Monitoring Application for ipad, ipod, iphone R R. and Android phones and tablets. Rev. 1.0

Integration Guide: innovi XProtect

How to Use Milestone with Hikvision Devices V1.0.0

MILESTONE INTEGRATION 1.4

XProtect Remote Client 3.7 User s Manual

Guide to Powering Agent Vi Analytics on Milestone s XProtect. savvi 5.3

VSPlayer Software User Manual

SD Card Player User Guide. Explains the program for searching and playing data stored on an SD memory card by Hanwha Techwin Network Camera/Encoder.

Milestone Systems XProtect Smart Client User's Manual

Paxton Net2 Integration for Milestone Access Installation and Configuration Guide

VAST 2.0. User Guide. version or above. Rev. 1.2

Milestone Systems. XProtect Smart Client User Manual

User Manual of VSPlayer Software. VSPlayer Software. User Manual UD06784B

Milestone Systems. XProtect Smart Client 2018 R2. User Manual

Milestone Systems. XProtect Smart Client 2017 R1. User Manual

Certified Solution for Milestone

IP Camera user guide

Easy Installation Guide

2017 R3. Milestone Systems. XProtect Web Client 2017 R3. User Manual

AEOS-Milestone plugin installation manual

Milestone Systems Milestone Mobile 2013 (Server)

XProtect Bosch Intuikey Keyboard Smart Client Plug-in User s Manual

Table of Contents Surveillance Center Overview...3 Log...30 Live Camera Panel...31 Live Camera Panel Explained I...32

USB Control Module Software Utilities

IPVideo Corporation. Mosaic TM Smart Client 2016 R2. User Manual

Viewer for Luma Fisheye IP Surveillance Camera. Software Manual

Vess A2000 Series. NVR Storage Appliance. Milestone Plug-in Guide. Version PROMISE Technology, Inc. All Rights Reserved.

Milestone Systems. XProtect Web Client 2018 R2. User Manual

Milestone Systems. XProtect Web Client 2018 R1. User Manual

XProtect Corporate Integration with C CURE 9000 v2.60 User Manual April 25, 2018

Operating Manual. Pelco Analytics on the edge integration. Pelco Edge Analytics Milestone MIP Plugin User Manual

Bosch Video Management System. User Manual

GV-IP Decoder Box Plus User s Manual

Milestone Dynamic Stream Selection Plug-in User s Manual

COMMAND STATION PC SOFTWARE

GV-Eye Mobile App. Contents

Milestone Systems. Quick guide: Search and export video evidence. XProtect Smart Client 2017 R3

XProtect Go 2016 R2. Specification Sheet

SMARTPROTECT INTEGRATIONS. SmartProtect Q-Guard Event Integration. Installation and Configuration Guide V 1.0.0

IP / CCTV OUTDOOR SPEED DOME CAMERA

Milestone Systems. XProtect VMS 2017 R2. System Architecture Document. XProtect Corporate XProtect Expert XProtect Professional+ XProtect Express+

Lens Selection Software. User Manual

Raytec Milestone Plug-in User Guide Document Revision 3.0

AVI321 / 311 Network Camera Series Quick Guide

Mirasys NVR. User s Guide

Milestone Systems XProtect Advanced VMS System Architecture. 1

Genie XMS Central Management Software

SETUP GUIDE BioStar 2 Integration for Milestone XProtect English

GV-Eye Mobile App. Contents

SAPPHIRE Viewer: The Collaboration Tool

HikCentral Control Client. User Manual

Milestone XProtect. Professional 7.0 Administrator s Getting Started Guide

XProtect Essential 2017 R1 Specification Sheet. Specification Sheet

INSIGHT Installation Instructions

Secure Guard Central Management System

Bosch Video Management System

Avigilon Gateway Web Client User Guide. Version 6.10

Warning Before Installation. Package Contents EN - 1. Refer to your user s manual for the operating temperature.

User manual. SmartPSS. Manual includes

VideoViewer (Browser-based Client)

+ milestone. Milestone Systems. Milestone Mobile client 2017 R3. User Guide

Client User Manual. Smarter Surveillance for a Safer World

GV-FE520 5MP H.264 Fisheye IP Camera

Milestone XProtect Enterprise ioimage Analytics Events Integration Manual

KNOWLEDGE BASE ARTICLE DISPLAYING SMARTVIS FACE LIVE IN A MILESTONE ENVIRONMENT

Milestone Systems. Milestone Mobile client 2017 R1. User Guide

GV-FE4301 4MP H.264 WDR Fisheye IP Camera

VAST 2. VMS for Small-to-Medium Scale Operations. Plug & Play Auto Setup Thumbnail & Smart Search 2.5D Visualization emap Problem Feedback Mechanism

icms Pro USER s MANUAL Ver 1.0

Milestone XProtect Corporate ioimage Analytics Events Integration Manual

AXIS Perimeter Defender with Milestone VMS. User Manual

Milestone Systems Milestone Mobile 2013 (Client)

EXERCISE: GETTING STARTED WITH SAV

GV-FE520 5MP H.264 Fisheye IP Camera

Overlap Checker & ENC Coverage User Manual

milestone XProtect VideoViewer for Gallagher 2.1; Administrator's Manual

Setting Windows File Associations to Open.JNLP Files Properly

USB DRIVER INSTALLATION GUIDE

GV-FE420 4MP H.264 Fisheye IP Camera

How to Troubleshoot Panopto Viewing Issues

set for a fixed view. Install the PTZ camera and the stationary camera in close proximity of each other

IP Mini PTZ CAMERA USER GUIDE

GV-Eye Mobile App. Contents

DocumentDirect for the Internet. User s Guide

Quick Start Guide GV-VMS

Luma Surveillance Mobile App. Owner s Guide. Version

Dell Storage Center Update Utility Administrator s Guide

TECHNICAL DOCUMENT FRONT PAGE DOCUMENT TYPE:

Technical Application Note

Guide VIGIL Server Quick Start Guide

Lens Selection Software. User Manual

User Manual of MIP HikAssistant Plug-ins. MIP HikAssistant Plug-ins. User Manual

QVR Pro Client 1.2. User Guide

Milestone. XProtect Basis milestone. milestone

XProtect Access 2017 R2 Specification Sheet

Avigilon Control Center Web Client User Guide

Milestone Paxton Integration Component User s Manual

Milestone Parcel Tracking 3.1 User s Manual

Transcription:

For Milestone XProtect Users: Application Note: Using VIVOTEK Fisheye Cameras with Milestone XProtect For Plugin rev. 3.0 A proprietary plug-in is available for users who install Fisheye cameras in a deployment managed by Milestone XPortect Corporate or Enterprise IP solutions. The plug-in enables image dewarp, pan, tilt, and zoom in/out over a video feed using a mouse or joystick. NOTE: The plug-in applies to: XProtect Professional/ XProtect Enterprise/ XProtect Expert/ XProtect Corporate / XProtect Express The plug-in does not apply to: XProtect Go/ XProtect Essential Complete the following procedure as the prerequisites for installing Milestone's SmartClient and the plug-in: 1. Download VIVOTEK's fisheye plug-in from VIVOTEK's Fisheye cameras' download page for appropriate plug-ins (for x64 or x86 versions*). 2. Install the.net framework 4.0 client profile**. The.NET framework is essential for installing SmartClient. 3. Install the DirectX runtime (9.29.1974)*** and above. The DirectX runtime is also necessary to the plug-in for managing DirectX components especially for older Windows XP systems. 4. Install the Milestone XProtect SmartClient 2014 9.0b or above (especially using plug-in v.2.0.0.0). 5. Unzip and execute the Fisheye Enhancer installer from a zip file: 5-1. By default, a sub-folder named MIPPlugins is available under the Milestone SmartClient 7.0 installation path. The default file path should look like the following: C:\Program Files\Milestone\MIPPlugins\VivotekFisheyeEnhancer 5-2. If you changed the SmartClient's installation path, use the Browse button to locate the MIP Plugins sub-folder. 5-3. Click Install to proceed with installation. * OS supports extends from Windows XP to Windows 10. ** http://www.microsoft.com/download/en/details.aspx?id=17851 *** http://www.microsoft.com/en-us/download/details.aspx?id=8109 Rev. 1.2

Prerequisites for Fisheye cameras: 1. To authenticate the use of the plug-in functionality, you must turn on a watermark on VIVOTEK's fisheye cameras: 1-1. Open a browser session with the camera. 1-2. Upgrade firmware to version 0100f or above. 1-3. Use the following URL command to turn the watermark on or off: ON: http://<camera_ip_address>/cgi-bin/admin/setparam.cgi?videoin_c0_enablewatermark=1 OFF: http://<camera_ip_address>/cgi-bin/admin/setparam.cgi?videoin_c0_enablewatermark=0 To enable the plug-in: 1. Make sure your fisheye cameras have already been added as Hardware Devices in the XProtect Enterprise/Corporate server's Management Application. 2. Start the XProtect Smart Client. 3. On the Live view window, click on Setup. 4. On the Setup window, search for the "VivotekFisheyeEnhancer" plug-in by dragging the pull-down menu on the System Overview pane to the bottom. Note that if you install the plugin when your SmartClient is started, re-start the SmartClient utility.

5. Click and drag the VivotekFisheyeEnhancer to a view cell. When done, the view cell will be highlighted by a light blue out frame. 6. Locate the Properties pane, and click on the Item Picker pane. An Item Picker window will prompt. Unfold the device tree and select a VIVOTEK fisheye camera. 3 2 1

7. Select appropriate camera Mount Type, Dewarp Type, and Camera Model. Select the Overlay Camera Information checkbox to enable a camera ID caption on the view cell. IMPORTANT: Make sure you select the correct Camera model for the one you selected on the Item Picker window. The working theories of different dewarp types are illustrated below: Rectilinear 1R View (Single Regional View) Zoom In Zoom in/out & all-directional navigation control Zoom Out

Double Panorama 2P View (Panoramic View) Converted to rectilinear view (Dewarp) Right hemi Left hemi 8. Although all fisheye camera lens have been adjusted before shipping, sometimes fields of views can be away from the center, or that a larger fisheye lens can cover the edges of a dome cover. You can then use the Dewarp Region tool to slightly adjust the Dewarp Region in order to produce a more comprehensive view. 9. You can now click on the Setup button to return to the Live view or Playback window, and exert control on the view cell using a mouse or joystick. Click on a view cell, hold down the mouse button, and swipe your mouse around to change view angle. Use scroll wheel to zoom in or out. This revision also provides a PiP control window for instaneous control of the Rectilinear display. You can click and drag the rectilinear area around the full coverage of view to a preferred location. You can also zoom in/out, or click and hold down the mouse button to swipe the dewarped view. This PiP window appears at the lower right corner on a Rectilinear view cell (when selected). Zoom In Zoom Out

Shown below is the availability of Dewarp modes for different Mount types: Dewarp mode \ Mount type Wall Ceiling Floor Rectilinear Yes Yes Yes Full Panorama Yes Yes Yes Double Panorama N/A Yes Yes None (Original Circular) Yes Yes Yes