DXp-10 and DXp-15 Weight Transmitter

Similar documents
LCp-100 Weight Indicator/Transmitter

DXP-40 FEATURES APPLICATIONS DESCRIPTION CONFIGURATION

Safe-Weigh Process Weighing System

LCt-104 FEATURES HTU MODE FEATURES APPLICATIONS DESCRIPTION CONFIGURATION

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

High Voltage DC Meter

BLH. DXp-40 Interface Manual Allen-Bradley Remote I/O WEIGH SYSTEM TECHNOLOGY. TM014 Rev D 6/1/11 Doc 35105

HIGH-VOLTAGE DC METER

Trident and Trident X2 Digital Process and Temperature Panel Meter

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Si 2035 Programmable Stepper Drive

ASTAT XB/XBm Remote Operator

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Product Description. Contents. Fusion Series. New Information December 2003

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

DTM Distributed Transmitter Monitor

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Digital Level Sensor. Consistent accuracy, unparalleled reliability. Answers for energy.

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

HTZ. Description. Features. Smart HART Humidity and Temperature Transmitter

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

SITRANS L Level instruments

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Digital Indicator Solutions

WEB TENSION TECHNOLOGY

MODCELL 2050R Single Loop Controllers

PD765 TRIDENT. Trident Series Process & Temperature Meters.

DISOMAT T Weigh Transmitter

LAUREL ELECTRONICS, INC.

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

SCADAPack Modbus multivariable transmitter

Weight Indicator. Model Intuition 22i FEATURES APPLICATIONS DESCRIPTION OPTIONS CONFIGURATION

LCI Load Cell Junction Box with Fault Monitor

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

LAUREL ELECTRONICS, INC.

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

Simplified information where and how you want it.

Carbon Monoxide Sensor - ModBus

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

MODEL 9250 Preliminary data sheet

PENKO Engineering B.V. When Weighing Counts FLEX Multi Channel Extended

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

ACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions

Explosion-Proof Gauge Pressure Transmitter

LCI User Manual mantracourt.com

UniPak UP448 Bridge Input Isolating Signal Conditioner

Isolated Process Current Input with Loop Power 7B35

/8 DIN Universal Process Indicator

4110 HART Level Encoder

PD765 TRIDENT. Trident Series Process & Temperature Meters.

SCADAPack Vision. Operator interface terminal. Vision10 Vision60

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Micro Motion Model 7950 and Model 7951 Signal Converters

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Technical specification

SIY. Features. PC-Programmable Signal Isolator/Converter

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.

Signal Isolators & Conditioners

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

HIT/HIX HART Isolator

Power and Performance for Weighing Applications

WI-I/O 9 Multi I/O Units

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

Shaft Speed: Shock: Vibration: Bump:

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

MODEL: GR8-EM. Communication Adaptor GR8 Series

DTM Distributed Transmitter Monitor

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

C500 Series Data Sheet

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

H704-42(H)(E), H704-42/1(H)(E)

DI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

HouseLINK HL-10A Installation and Operation Manual

EC Type-Approval Certificate

MMT330 Series Moisture and Temperature Transmitters for Oil

Measurement Systems Datascan Installation and User Guide

Analog signal to RS485 or RS232 Converter, A/D Converter

This Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs

VariTrans P The Problem The variety of tasks results in a large number of different devices.

3000 SERIES LOW PROFILE FLOOR SCALE.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Transcription:

Precision Force and Weight Measurement Technologies DXp-10 and DXp-15 Weight Transmitter Applica pplications: Inventory Weighing Process Weighing Web Tension Measurement Product Description l Microprocessor Based Weight Transmitter l Integral Multi-Cell Summing Circuit l Standard Digital RS-485 Output l Optional Analog 0-10V and 4-20 ma Outputs l Optional Modbus RTU or Allen Bradley Remote I/O Protocol l Fault Protected Transducer Excitation The DXp-10 and DXp-15 Transmitters are self-contained microprocessor based weight transmitters. Both units contain an internal multi-cell summing circuit, 10 or 15 volt excitation, and a digital RS-485 output. Analog 0-10 volt and 4-20 ma outputs are available as an option. DXp transmitters are designer to be field mounted within the standard cable length of the load cells and are available with NEMA 4, 4X, or explosion proof enclosures. The DXp-10 offers 20,000 counts of digital resolution with a response time of 400 milliseconds. For high speed batch and packaging applications, the DXp-15 offers 50,000 counts of digital resolution with a response time of 50 milliseconds. DXp-15 units are available with Allen-Bradley Remote I/O or Modbus RTU protocol for convenient interface with host PLC/DCS systems. BLH Electronics, Inc. An ISO 9001 Registered Company

DXp Advanta antages Applications The DXp-10 and DXp-15 transmitters are designed for inventory and process weighing, as well as web tension measurement systems requiring analog and/or digital transmission of high accuracy weight data to a computer or other control device. Availability of a wide variety of digital interface options simplifies communication of weight data to a host computer or PLC. The result is improved product quality and material control. Serial Communication The RS 485 serial output is DIP switch selected to transmit one of four data formats. The transmit-only mode is designed for simple point-to-point communication to a single receiver. The optional interface mode is available for connection to a terminal for calibration or for operation on a multi-vendor baseband network. Available MODBUS RTU protocol or the Allen-Bradley Remote l/o interface options provide a seamless interface to most DCS and PLC systems (DXp-15 only). Analog Communication The optional analog voyage and current outputs are based on a 12 bit D-A conversion providing up to 4096 counts of gross weight resolution. The isolated analog output will drive up to a 1000 ohm load for connection to an analog input card, loop controller and/or digital indicator. Because the analog weight data is based on a digitized weight signal it can be ranged to any portion of the gross weight capacity. This solves many problems previously encountered with high dead-load/small live-load applications. Set-Up and Calibration Simple set up and calibration of both the analog and digital outputs is accomplished without a programmer by using the various internal switches to set zero, span, etc.. In addition, an internal calibration circuit with a Check Cal switch is provided. Remote calibration can be accomplished using the LCp-40 Network Controllers or with a terminal capable of transmitting ASCII in an RS 485 format. Hybrid Technology Mating a muhi-cell summing unit to a transmitter with both analog and digital output capabilities offers the user the flexibility of using traditional analog control strategies with existing equipment and the opportunity to take future advantage of digital control networks without replacing the transmitter. DXp-10/15 Control Panel

Outline and Wiring Diagrams ams DXp-10/15 Outline Dimensions (inches)

DXp-10/15 Specifications Performance Resolution: DXp-10 20,000 counts DXp-15 50,000 counts Sensitivity: DXp-10 1.0 microvolt/count DXp-15 0.5 microvolt/count Full Scale Range 25 or 35 mv (selectable) Dead Load Range 100% Input Impedance 10 M-ohms, min Load Cell Excitation (Selectable) Linearity Humidity Common Mode Rej. Normal Mode Rej. Conversion Speed Temperature Effects Span Zero Operating Temperature Storage Temperature 10 V for up to eight 350 ohm load cells (250 ma) 15 V for up to six 350 ohm load cells (260 ma) +/- 0.01% of full scale 5 to 90% rh, non-condensing 100 db or better at or below 35Hz 100 db or better at or below 35Hz DXp-10-400 msec DXp-15-50 msec +/-2ppm/ C typical, 7ppm/ C max +/-2ppm/ C -10 to 55 C (12 to 131 F) -20 to 85 C (4 to 185 F) Enclosure Dimensions (NEMA 4/4X) Explosion Proof OPTIONS Isolated Analog Output Type Voltage Current 11.5 x 8.0 x 4.3 HWD 12.875x 10.875x8.188 HWD 12 bit D/A conversion 0 to 10 volt (25K ohm min load) 4 to 20 ma (1000 ohm max load) SERIAL COMMUNICATION Simplex Data Output (Standard) Interface Type RS-485 (simplex) Data Format simplex ASCII data 7 Data Bit Even Parity 1 Stop Bit Terminal/Computer Interface (Optional) Interface Type RS-485 Half Duplex (Standard) Baud 1200 or 9600 Protocol ASCII duplex command/ response format Modbus RTU Protocol (DXp-15 Option Only) See manual TM002 for function codes and register locations Electrical Voltage Power Parameter Storage EMI/RFI 117/230 + 15% 50/60 Hz 10 watts max EEPROM Shielded from typical industrial interference Allen-Bradley Remote l/o (DXp-15 Option Only) See manual TM010 or technical note TD078 for details PLC and Allen-Bradley are trademarks of Allen-Bradley Co, Inc. Modbus is a trademark of Schneider Automation. BLH is continually seeking to improve product quality and performance. Specifications may change accordingly. PD 668 June 1999

Ordering Specification Code DXP-10- [M]-[C]-[P]-[S] Blind Weigh Transmitter with 20,000 Count Resolution DXP-15- [M]-[C]-[P]-[S] Blind Weigh Transmitter with 50,000 Count Resolution DXP-10 DXP-15 [M] MOUNTING [1] NEMA 4 PAINTED STEEL ENCLOSURE STD STD [2] NEMA 4X STAINLESS STEEL ENCLOSURE [3] NEMA 7/9 EX ENCLOSURE [Class I II, Div 1 2, Group BCDEFG] [8] #1 & FM/CSA Approved [Class l ll lll, Div 2, Group ABCD FG] [9] #2 & FM/CSA Approved [Class l ll lll, Div 2, Group ABCD FG] [C] COMMUNICATION [1] RS-485 DIGI-SYTEM ENABLED STD STD [2] #1 & RS-485 ASCII PROTOCOL N/A [4] ALLEN-BRADLEY REMOTE I/O ( NOTE: [1] & [2] DELETED ) N/A [5] #1 AND MODBUS RTU PROTOCOL * N/A [P] PROCESS OUTPUTS [1] NO PROCESS OUTPUT STD STD [2] 0-10 V & 4-20 ma ANALOG [S] SOFTWARE [1] STANDARD STD STD [2] DYNAMIC DIGITAL FILTERING N/A ACCESSORIES: Conduit Fitting Kit (6 connectors) P/N 465231 Cable Fitting Kit (6 connectors) P/N 465232 * May Require RS-485 to RS-232 Serial Converter. See Section VI