Model XS1000 TCP/IP to RS232/422/485 Device Server User s Manual

Similar documents
NordField Electronics

Industrial Serial Device Server

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

SERIAL TO ETHERNET CONVERTER E-P User Manual

Serial to Ethernet Converter HL-SE02P-V1. User s Manual V3.606

Tel: Fax:

EX-6014WI RS232 to WiFi Wireless Adapter, w/ Mounting Kit

Industrial Device Server IDS-3010 Fiber Series

TCP/IP Converter. EX-9132 Operation Manual for 8051 Series

User s Guide. Ethernet Module for Barcode Printer

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

LM300 Bluetooth Ethernet Access Point/Server 3 Simultaneous Bluetooth SPP Connections

e-net TCP/IP Converters

Operation Manual of EX-9132C-2. Serial to TCP/IP Converter

GEM80 & ewon Setup Quick Guide

ACE PLUS CORP. APCON100 series Operation Manual RS-232 to Ethernet Converter

Operation Manual of EX9132CST-Series

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Serial to Ethernet Converter

1 port RS-232 Device Server

1 Port RS232 Serial over IP Ethernet Device Server

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

Operation Manual EX-9133C-2-MTCP

LM300 Bluetooth Ethernet Access Point/ Server 3 simultaneous Bluetooth SPP connections

Universal ipulse Ethernet Adapter. User Manual

Modbus Gateway User's Manual ADM-5850G

TRP-C37 User s Manual

PX Serial - Quick Start Guide

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

STE100A Single Port IP to Serial Device Server

TRP-C34H. Ethernet to 4 RS232/422/485 Converter. User s Manual. Printed Sep Rev 1.1

NetCom Mini. SCADA system Building automation system Self-service banking system Other remote and distributed serial devices control

User Manual A08. User Manual

Ethernet Serial Server

ECOV-110 User s Manual

BF-430 User Manual Document Version 1.0 Web Version realcom Firmware Version ,Apr

SERIAL TO WiFi CONVERTER EX-9486C-W User Manual

SSE232-LE Serial Server- User s Manual

NetBiter Serial Server User Manual

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

WIZ107SR User Manual

LM300 Manager User Manual. Document Version: 1.1 LM300 Firmware Version: Bluetooth Firmware Version:

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6

DGH A3000 Configuration Guide For use with DGH Modules

SERIAL TO TCPIP CONVERTER E-P232-X. User Manual

USR-TCP User Manual

WiFi to RS-232 adapter user manual

RS-232/422/485 Over IP Adapter

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

CHIYU. Product Specification BF-450(M)/BF-430. RS232/RS485/RS422 To TCP/IP Converter Module. Release 1.0

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

GEM-10 GPRS/Modbus Gateway User Manual. Rev /2012

STE100A Single Port IP to Serial Device Server

TRP-C37M User s Manual

MSD-SRF2XM Multi-port RS-232 to Ethernet Data Gateway User Manual

Ethernet to Serial Port Module RS-232/422/485 to Internet Gateway

SICOM3171 Series Managed Traffic Ethernet Serial Server. Software Operation Manual

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway

TRP-C37M User s Manual

Industrial Device Server User s Manual

User Manual Anybus Serial Server

International Headquarters. European Headquarters

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

International Headquarters. European Headquarters

ezconfig User s Manual

3-7 Tiny Serial-to-Ethernet Device Server & Modbus Gateway

USR-TCP User Manual

Serial to TCP/IP Converter

WIZnet PRODUCT GUIDE.

Lantech IRC-0101 RS-232/422/485 TO TCP/IP CONVERTER. User Manual

5600 Series. 8 and 16-port Serial Device Servers. Features. Internet Readiness for up to 16 Serial Devices

Serial Device Server- Dual Port Quick Installation Guide

On the left hand side of the screen, click on Setup Wizard and go through the Wizard.

Quick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network.

tgw-700 Series User Manual

Chapter1. Interface Introduction

USER MANUAL FOR GS100/GS1003G

Overview. Table of contents

eztcp Configuration Software ezmanager Manual Version 1.9 Sollae Systems Co., Ltd.

WIZ220IO / WIZ220IO-EVB User s Manual (Ver. 1.0)

EZL-400S User s Manual

User s Manual ICS-100 / ICS-102 / ICS-102S15. RS-232/RS-422/RS-485 over 100Base-FX / 10/100Base-TX Media Converter

tsh-700 Series User Manual

SB72EX User's Manual

ETH002-2 Relays at 16A Technical Documentation

User s Manual ICS-100 / ICS-102 / ICS-102S15. RS-232/RS-422/RS-485 over 100Base-FX / 10/100Base-TX Media Converter

Communication adapter RS485/422 over the Ethernet ELO E222. User manual

Real/Virtual COM. JetPort Commander

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

WiFi to RS-232 adapter user manual

SerialComm ETH-SER-EE9 Serial Device Server / Ethernet to Serial Converter User Manual

ecov-110 User s Manual (V0.9f_Eng)

WiFi to RS-422/485 adapter user manual

Super Port User Guide Contents Serial to Ethernet converter(super Port) Introduction Overview Features Applications

Transcription:

Model XS1000 TCP/IP to RS232/422/485 Device Server User s Manual 3.0. Hardware Installation & Initial Setup 3.1 RS-232 Configuration:(DB9 Male) (DB9Male) Signal I/O PIN2 RXD IN PIN3 TXD OUT PIN5 GND - PIN7 RTS OUT PIN8 CTS IN 3.6 Connection Diagram RS-232 Connection 1.0 Introduction The XS1000 is a cost effective and highly integrated Serial-to-Ethernet 10/100Mbps device server. Embedding a 8051CPU with 64KB OTP ROM and 32KB SRAM. The serial interface supports handshake signals RTS and CTS. The XS1000 can access a serial RS232/422/485 device located virtually anywhere (via Ethernet or Internet). It automatically finds devices on the network and can be configured by a web-browser. 2.0 Features: 3-in-1 RS-232/422/485 interface Max.230Kbps Serial interface and 10/100 Mbps Ethernet. Supports 4- and 2-wire RS-485 with AUTO-SEND. Terminal block for easy RS-422/485 serial wiring Supports IP configuration by MAC address. Supports Driver, TCP Server/Client, UDP Server/Client and Pair Connection protocols. Easy and powerful configuration management. Approvals: CE, RoHS. 3.2 RS-422/485 Configuration:(terminal header) Terminal No 1 2 3 4 5 6 RS-422 T+ T- R+ R- VIN GND RS-485 485+ 485- - - VIN GND 3.3 Connecting to 10/100M: Use a standard Ethernet cable to connect the XS1000 to an Ethernet switch, or use a cross-over cable if you connect it directly to a PC. 3.4 Power Supply: The XS1000 needs a 9 to 24VDC 1000mA power supply. 3.5 XS1000 LED indication: LINK: Ethernet Link established. ACT: Data flow TX/RX. PWR: Power ON. RS-422 Connection RS-485 Connection

4. Configuration and Operation A. Assign a static IP address to your computer in the 192.168.2.2 to 192.168.2.254 range. Subnet mask 255.255.255.0. This is necessary to ensure that your computer can communicate with your XS1000. Your computer must have an Ethernet card and TCP/IP installed. 4.1 The menu features as below: DHCP. These types are listed in the Web page for the IP Configuration settings. Each setup screen and available features will differ depending on what kind of IP connection types you select. Default is Static IP B. The default IP address of the XS1000 is 192.168.2.1. Open your web browser and enter this IP address to connect to the XS1000. C. UDefault user name is admin and the password is system.u Click OK. The setup screen will then appear, and you can now configure the settings. D. Create a new COM port using VCOM.exe. Menus explained: 4.2 Administrator Setup Main admin window. 4.3 Authentication The user can change the username and password to prevent unauthorized access. Login ID and password authentication, the maximum number of characters is 15, (characters and numbers). User Name: default admin Password: default system 4.3 System IP The XS1000 support two IP connection types: Static IP and Static (or Fixed) IP IP Address: default U192.168.2.1U Subnet mask: default U255.255.255.0 Gateway: default U192.168.2.254 Primary DNS: defaultu 192.168.2.253U If you are connecting through a static or fixed IP from your network environment, perform these steps: Step 1: Enter IP address Step 2: Enter Subnet mask Step 3: Enter Gateway IP address Step 4: Enter Primary DNS IP address Step 5: click Update button 4.6 DHCP Host Name (Optional): default NETUART, maximum length 15 characters. If there is a DHCP Server existing in your network environment, you can set the IP configuration to DHCP to get a dynamic IP address. The Host Name is an optional item, depending on your DHCP Server setting.

5.0 System Status This screen shows the XS1000 s current status. All of the information provided is read-only. Kernel Version: the installed version of the kernel. MAC Address: The present device MAC Address. Nickname: the product s NetUART model name. 5.0 Load default setting Allows the user to reset the XS1000 to default settings. The MAC Address will not be updated. 5.1 Telnet Currently not supported. 5.2 Operation mode The XS1000 supports four operation modes: TCP Server, TCP Client, UDP Server and UDP Client. These modes are listed in the Web page for the Operation Mode setting. Each setup screen and available features will differ depending on what kind of operation mode you select. Default is TCP Server. 5.3 TCP Server Port Number: default 23, range 0 to 65535 If your device is acting as a passive device to accept commands from a remote device and the data needs to be guaranteed to be received by the peer is your concern, then you can set the XS1000 as TCP UServerU. Be sure the value of the setting Port Number is same as your remote control application using. Client mode inactive timeout (minutes): default 20 ( 0=Disable) If you want to keep the connection between XS1000 and your remote control application always on, then set the value of item Client mode inactive timeout (minutes) to 0, otherwise, when the inactive time of no traffic on the line reach the configured value, the XS1000 will terminate the connection. 5.4 TCP Client Remote Connection Port Number: default 23, range 0 to 65535 Remote Host IP Address: default 210.200.181.102 If your device is acting as an active device to report real-time status to remote devices and the data needs to be guaranteed to be received by the peer is your concern, then you can set the XS1000 as TCP UClientU. Be sure the value of the setting Remote Connection Port Number is same as your remote control application using the correct value of Remote Host IP Address. 5.5 UDP Server Local Port Number: default 21, range 0 to 65535 If your device is acting as a passive device to accept commands from a remote device and the data needs to be guaranteed to be received by peer is not your concern, then you can set XS1000 as UDP Server. Be sure the value of item Local Port Number is same as what your remote application is using. 5.6 UDP Client Remote Connection Port Number: default 21, range 0 to 65535 Remote Host IP Address: default 192.168.2.2 If your device is acting as an active device to report real-time status to a remote device and the data be guaranteed to be received by the peer is not your concern, then you can set XS1000 as TCP Client. Be sure the value of item Remote Connection Port Number is same as your remote control application using the correct value of Remote Host IP Address. 6.0 UART Control (RS-232) Use VCOM for creating a new COM port. The XS1000 support three serial types: RS232, RS422 and RS485. Baud Rate: default 57600, range 300bps to 230.4Kbps. Character Bits: 5, 6, 7, 8 (default). Parity Check: None (default), even, odd, space, mark. Stop Bits: 1 (default), 1.5 or 2. Hardware Flow Control: None (default) or Hardware.

Mechanical dimensions 5mm 32,5mm XS1000 25m 94mm 15mm 45mm 14mm All mounting holes: Ø3.5mm 66mm 26mm Note to Admin Panel s UART Control advanced settings: Character 1 and 2: These are HEX numbers. Default value: 00FF. When sending data from serial to TCP the data is fist stored in the cache, not until the value of character 1 or 2 is received from the serial side the data is released from the cache and sent to TCP. Silent time: If there is no data sent or received for the number of milliseconds specified the connection is dropped. Drop character: Drops the delimiter character of the serial port when sending to TCP, (the receiver doesn't display the character).

How to hardware reset XS1000 1. Disconnect the Ethernet cable. 2. Disconnect the serial cable. 3. Disconnect the power supply. 5. Locate the small hole next to the power supply jack. The reset button is inside the hole. 6. Press the reset button (using a paperclip or small screwdriver) and hold the reset button. 7. While pressing/holding the reset button connect the power supply. 8. The red Power LED light will come on and the green Link LED light will light up dimly for about 1 second. 9. Hold the reset button for about 10 seconds and release it. No LED light indication will show when the unit has been reset, you just have to hold the button for 10 seconds. 10. The XS1000 now has been reset to factory settings. Notice: the unit can also be reset from the web interface. To access technical support, please visit the U.S. Converters website at: www.usconverters.com Here you will find: - Latest drivers and updates for download - Technical tips - Documentation - Configuration support - and much more Feel free to contact our technical support team at mail@usconverters.com with any issues.