Electronic Vibration Switch PMC/BETA 440 & 450

Similar documents
MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

Vibration Switches viib

Vibration Switches. For 24/7 Protection of Cooling Towers, Fin Fans, HVAC Systems, Blowers, Motors and Other Critical Machinery

CSI 9330 Vibration Transmitter

Level-Lance Model 5400A

Vibration Switches. kmo turbo GmbH Friedrichstr Friedrichshafen Germany

Electronic, Digital and Mechanical Vibration Switches

SKF Machine Condition Transmitters (MCT) Series

Description. Specifications and Ordering Information 9200, 74712, Seismoprobe Velocity Transducer System

Family of Water Cut Analyzers

DTM Distributed Transmitter Monitor

Si 2035 Programmable Stepper Drive

Type 330SA High-Performance Electric Actuator

VMS Co., Ltd. VMS Reliability Systems - Korea

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

DD1590 Series Proximity Driver. Connection Technology Center, Inc. Vibration Analysis Hardware. DD1590 Series. Proximity Probe Driver.

YTM Series Digital-Transmitter-Monitor

Industrial Vibration Monitoring

Velomitor * Piezo-velocity Sensor

Reliable Electronic Vibration Switch Protection At the Low Price of a Mechanical Switch!!!!

TPE 1464 Series Pressure Transducer

Portable vibration calibrator Model 28959G

78 Series Electromechanical Relay Selection Guide

Proximity Vibration / Position / Phase Reference Transmitters

Model 720 Electromechanical Hour Meter

DTM Distributed Transmitter Monitor

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

9200, Seismoprobe* Velocity Transducers

Velomitor* CT Velocity Transducer

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC.

VS102 Electronic Vibration Switch

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

9200, Seismoprobe

SW6000 SEISMIC VIBRATION SWITCH Installation Manual

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

9200, Seismoprobe * Bently Nevada* Asset Condition Monitoring

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

DM28 - Economical Digital Process and Strain Gauge Panel Meters

Photoelectric Sensors 20 Series

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

ReferenceMate handheld shaker Applications and specifications

MACHINERY CONDITION MONITORING World Class Sales & Service Support

and High Temperature Velomitor * System

and High Temperature Velomitor * System

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

Tachometer Panel, PE3

Sensors and Systems. Short Form. that protect your plant...

Large DIspLay process Meters

955 ebrik INSTALLATION MANUAL. Series ebrik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS LINEAR DISPLACEMENT TRANSDUCERS

Telephony Multi-Taps. 9000T-TP Series

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

XM-720 Machine Monitor

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

INSTALLATION INSTRUCTIONS

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Digital Indicator Solutions

991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring

NETRONICS HS3500 CONTROLLER

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

Protection Cards for AMS 6500 Classic Systems

991 Thrust Transmitter Bently Nevada* Asset Condition Monitoring

Ground Fault Protection

PRO VPR100 Series ViPR Multi Channel Monitoring System

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Installation, Operation and Maintenance Instructions

Proximity Transducers, Seismic Sensors and Accessories

440 / 450 Electronic Vibra on Switches Datasheet

EMS467 Monitoring System. Installation and Operations Manual Section 40

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

Sensors and Systems. Short Form. that protect your plant...

+GF+ SIGNET ph/orp Transmitter Instructions

DM200 Dual-Channel A/V/D Vibration Monitor

Magnetically Actuated Safety Interlock Switches

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

PGR-3200 MANUAL INSULATION MONITOR

Introduction Circuit Protection

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

Signet Pressure Transmitter

FieldLink process networking

407B 1/16 DIN Multi-Mode Timer

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

IS-3000-LS-ABB INFRARED SCANNER

8mm, 5mm Proximity Probe TM0180 and TM0105 Systems

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

T E M P O S O N I C S I I I INSTALLATION

dual-line 6-dIGIt process MeteR

Compliance with API Standard 670 the PRO Product Standard for Proximity Probes

Transcription:

PMC/BETA & Features Built-in alarm time delay Reduce false triggering Velocity triggering provides protection at all frequencies Displacement triggering available for low speed machinery Sensitivity is not affected by rotating speed of machinery Analog dial for setting limits Solid state relay contacts used for alarm and/or shutdown Field settable for N.O. or N.C. Remote reset capability Provision for self-test and calibration - ma output available Built-in transducer or optional remote transducer Cast aluminum enclosures meet NEMA,, and standards Explosion-proof models ( Series) available PMC/BETA electronic switches utilize a solid state crystal accelerometer which provides an electrical output when it is deformed by the vibration forces. The output is electronically converted to a signal proportional to velocity. This signal is compared with a preset limit and triggers a solid state relay if the limit is exceeded. There are no moving parts in the vibration switches except when configured with mechanical relays. While the costs more than a mechanical switch, it uses the same technology as sophisticated remote monitoring systems and provides most of the capabilities of these systems at / to / the cost per monitor point. An important feature of PMC/BETA switches is the built-in time delay. This prevents triggering of the alarm or shutdown functions from transient increases in vibration levels. It also avoids shutdown due to transitory vibrations occurring during start-up. Almost all machines experience a few seconds of high vibration during start-up before reaching operating speed. When no time delay function is included, as with mechanical switches, this start-up vibration causes a trip. Frequently, the operator turns the trip setting up until he can get through start-up. The resultant trip level is too high to afford protection at the machine s operating speed. Three-second alarm trip delay is standard on PMC/BETA switches. Alarm time delays are independently adjustable in the field over a range of to seconds. Built-in piezoelectric transducer module with integral amplifier provides to, Hz capability. Calibrated set point controls enable operator to set specific velocity trip points. Test position sets in minimum set point so that any vibration will cause trip condition. Light will come on immediately, and trip will occur after duration of the time delay, proving that the complete system is operational. If test position is maintained for less than the duration of the time delay, trip will not occur, thus permitting system test without shutdown. VDE approved terminal strip accepts # wire. Screw adjustable clamping yoke rather than screw terminal permits easy, vibration proof connection. All hardware is captive. Light comes on immediately when vibration exceeds set point (alarm or shutdown will trip after second time delay). Adjustable time delay of - seconds. Factory set at seconds. Each solid-state contact is independently field settable to open on alarm (N.C.) or close on alarm (N.O.).. www.metrix.com sales@metrix.com Sales & Service Tel: -- Fax: --8 /

PMC/BETA & Specifications Weight & Dimensions No. of Trips: S & SR: ONE: for alarm or shutdown. Set in in/sec (velocity model) or mils (displacement model). D & DR: TWO: One for alarm and one for shutdown. Shutdown set in in/sec (velocity model) or mils (displacement model). Alarm set as percent of shutdown. Analog Output for Trending and Remote Indication: S & D: N/A SR & DR: ± % accuracy over - ma DC range. Absolute Option: ma = vibration; ma = Full scale range of switch. (Recommended) Dependent Option: ma = vibration; ma = set point; ma is % of set point. Termination load resistance, less than ohms. Velocity Set Point:. to. in in/sec or. to in/sec peak. Metric ranges: to mm/sec or to 8 mm/sec peak Displacement Model: to mils or to mils peak to peak. Metric ranges: µm to µm or µm to mm peak to peak Frequency Range: to Hz Time Delay: Field adjustable - sec. Factory set for sec unless specified otherwise Alarm or Shutdown Output(s): Solid state relay (triac). One in S & SR; Two in D & DR. Isolated (dry) contact. Each triac field settable for close on alarm (N.O.) or open on alarm (N.C.). A continuous, A for msec. Max. off-state leakage current: ma Min holding current: ma typical Max. voltage across SS relay: VAC (8VAC on V input units) NOTE: If the relay output is connecting to a PLC or DCS, DO NOT use A Triac. See How To Select D & E. Remote Reset: Connection between terminals and latches triac output in alarm state after setpoint is exceeded. Opening the connection will reset the output to non-alarm state. Set Point Accuracy: ± % of setting with repeatability of ± %. Circuitry utilizes RMS detector Vibration Sensitive Axis: Perpendicular to base. Unit can be mounted in any orientation without affecting setting Temperature Limits: - F to + F (- C to + C) including internal transducer. - F to +9 F (- C to +88 C) for optional external transducer Humidity: % to % (non-condensing) Input Power: - VAC / Hz standard. - VAC / Hz optional. DC input power optional. S, Watt, D, Watt Enclosure: Rugged, water-tight, dust-tight, cast aluminum. Meets NEMA,, and standards. Optional CSA mark for Class I, Div, Grps B-D, Or explosion-proof Model. Weight: -. kg (. lbs); -. kg ( lbs) Mounting: / hardware, mounting bosses Terminals: All terminals will accept # AWG wire in clamping type yoke without need for termination hardware. ALL hardware is captive. Self Test: Test position on set point control and light emitting diode provide functional test of trip circuitry, time delay and triac closure. Also permits on-line calibration of switch. Circuitry: Proprietary hybrid circuitry throughout for minimum size and maximum reliability in vibration environment. Remote Transducer Option: The standard includes a built-in transducer. A separate transducer can be specified. Please request separate transducer when placing order. See How To Select page. The SA accelerometer ( mv/g) is recommended. 89 [.] SENSITIVE AXIS. [.8] 89 [.]. [.] 9. [.] SHUTDOWN ADJUST SHUTDOWN LED SHUTDOWN DELAY SET N.O./N.C. SLIDE SWITCH (SHUTDOWN) 8 [.] [.] 89 [.] Weight:. kg [. lbs] Dimensions in mm [inches] / - NPT ALARM ADJUST ALARM LED ALARM DELAY SET N.O./N.C. SLIDE SWITCH (ALARM) GROUNDING TERMINAL NOTE: For single limit units, shutdown output is used.. [.] X.9 [.]. [.] See Weight & Dimension drawing on pg.. www.metrix.com sales@metrix.com Sales & Service Tel: -- Fax: --8 /.

PMC/BETA & How To Select Special modifications and options will receive an M number, assigned by the factory. Model - Epoxy coated NEMA, and CSA Class I, Div., Grps B-D except w/ mechanical relays and external transducer Model - Epoxy coated NEMA, and CSA, Class I, Div., Grps B-D; Class II, Grps, E-G A B C D E F G H I J K L M N - - - A B C D E F G H I J K L M N - - - A Single or Dual Trip/Analog Signal Output E Alarm Circuit (Always if A = S or SR) B C D S SR D DR 8* = Single Trip = Single Trip, Analog Signal Output = Dual Trip = Dual Trip, Analog Signal Output Analog Signal Output = None = - ma, dependent (legacy) = - ma, absolute (recommended) = - Vdc, absolute = - Vdc, dependent = - Vdc, absolute = - Vdc, dependent Scale =. -. in/sec =. -. in/sec = - mm/sec = - 8 mm/sec = - mils displacement, pk-pk = - mils displacement, pk-pk = - microns displacement, pk-pk =. - mm displacement, pk-pk = - ma *NOTE: For use with a Vdc loop-powered transmitter. * Shutdown Circuit = Triac, A, SPST (for switching heavy AC loads) = ma, Volts, Pk, analog, SPST switch, good selection for use with PLC or DCS = OBSOLETE,. Amp SPDT relay (replace w/ x, A SPST relay) = A SPDT relay = A DPDT relay where A = S or SR only = A, V pk, Analog Switch = ma, V, pk, Analog Switch F G H 8 = None = Triac, A Standard = ma, Volts Pk, Analog SPST Switch (Use for PLC or DCS) = OBSOLETE,. Amp SPDT relay (replace w/ x, A SPST relay) = A SPDT relay Alarm Only = OBSOLETE, A DPDT Relay, Internal Xducer only = V, pk, A Analog Switch = ma, V, pk, Analog Switch Enclosure = Standard, CSA, Class I, Div, Grps B-D* = OBSOLETE, All s have epoxy paint = Pushbutton reset = OBSOLETE, See F = or = OBSOLETE, All s are Grps B,C & D = Velocity signal out via BNC connector, 8 mv, rms/ips, pk = Pushbutton reset and Velocity out = Acceleration signal out via BNC connector, mv/g = Pushbutton reset and BNC Accel. out *Note: Except for mechanical relays, external transducers and BNC connectors. Input Power = Vac, / Hz = Vac, / Hz = Vdc ± % = OBSOLETE, Vdc ± % = OBSOLETE, 8 Vac, / Hz Lockout Function = None = Lockout = sec startup, lockout delay = OBOLETE, -9 sec variable startup, lockout delay = OBSOLETE, Vdc enabled lockout, input power must be Vdc Continued on next page. www.metrix.com sales@metrix.com Sales & Service Tel: -- Fax: --8 /

PMC/BETA & / How To Select Continued I External Transducer Option = Internal = A or E Accelerometer (legacy sensor) = 8 Velocity Transducer (legacy sensor) = SV Piezo-Velocity Transducer = Explosion-proof Accelerometer - see option = SA Constant Current Accelerometer - Recommended = 8E X-proof velocity transducer - see option = Other Constant Current mv/g Accelerometer 8* = Vdc loop-power transmitter Model D NEMA, Class I, Div., Grps. B,C & D J *NOTE: Available with to % of transmitter input range or to impacts. Other Special Model S/S (Single Trip) One limit for alarm or shutdown. Leave blank if not applicable = CE mark for only Model SR/SR (Single Trip w/- ma output) One limit for alarm or shutdown, and - ma output for remote vibration readout or computer interface. K External Transducer Scale - use when applicable = to pk = RMS = pk to pk = ma Model D NEMA, Class I, Div., Grps. B, C & D L M N External Transducer Sensitivity mv/unit use when applicable 8 = mv/g = mv/ips = mv/ips = mv/ips = mv/ips = mv/ips = mv/g, rms (legacy sensor) = 8 mv/ips, rms (legacy sensor) Model D/D (Dual Trip) One limit for alarm, a second limit for shutdown. Note: Model SAA (mv/g) or SV (mv/ips) is recommended for use with - switches. Please contact factory for options and pricing. Model DR/DR (Dual Trip w/- ma output) One limit for alarm, a second limit for shutdown, and - ma output for remote vibration readout or computer interface. www.metrix.com sales@metrix.com Sales & Service Tel: -- Fax: --8 /.

PMC/BETA & Machine Transducer Model / Switch Model / Switch Machine Model 8- Meter Remote sensors with Model /. The standard / includes a built-in transducer. For some applications, a separate transducer is available as an option in place of the internal transducer. The can then be mounted in any convenient location up to, feet away. The / can be configured for a single remote sensor input, from a variety of sensor types or transmitters. Remote indicator with Model / vibration switch. The Model 8- meter will provide continuous readings of vibration level from the - ma dependent output of the SR or the DR. The meter reads from to % of shutdown setpoint. The - ma output can also be used to drive a strip chart recorder or PLC input. Single or Dual Trip Switches Provide Early Warning The Model S provides a single switch closure which can be used for alarm or shutdown. However, it is often desired to provide a warning before shutdown. The Model D is ideal for this requirement. It provides two trips: one for alarm and one for shutdown. The first trip is set at a vibration alarm level to provide early warning that the condition of the machine is deteriorating. When the alarm trip occurs, the operator can evaluate the condition and schedule corrective maintenance - at a time that does not interrupt the production schedule. If the machine condition continues to deteriorate, the shutdown trip provides protection against catastrophic failure. The / as a Vibration Transmitter The - ma output available on the model SR and DR can be utilized to drive a remote display or to interface to a PLC or other plant computer for trending of vibration. For trending applications the ABSOLUTE analog output option is recommended. In this configuration ma is equal to the full scale range of the switch. Velocity Trip The different causes of machinery failure (imbalance, misalignment, bearings, etc.) result in increased vibration at different frequencies (CPM) on a given machine. Typical Installations Therefore, it is important that the vibration protection device be equally sensitive to damaging vibration at all frequencies. International standards for rotating machinery (ISO, 9) specify that vibration severity is directly related to vibratory velocity. The PMC/BETA / series electronic vibration switches measure and trip on velocity. In mechanical switches, sensing and tripping are inherently limited to impact/acceleration. Since severity (damage potential) is proportional to velocity, acceleration tripping is oversensitive to some frequencies and not sensitive enough to others - with the result of either false trips in some cases, or not enough protection in others. Why Use Remote Sensors Vibration switches can be configured to work with external sensors (accelerometers, velocity pickups or transmitters). When an external sensor is used, the internal accelerometer is not present. Mounting location size, temperature considerations, vibrating environment and application would determine when to use an external sensor. For example, if the vibration switch is too large to fit a machine location, consider using a remote accelerometer and an interconnecting cable. SWITCH LOCATIONS SWITCH CENTRIFUGAL PUMP / MOTOR ENGINE COMPRESSOR. www.metrix.com sales@metrix.com Sales & Service Tel: -- Fax: --8 /

PMC/BETA & Available Transducers Mating Connector/Cable Assemblies SA Accelerometer, available with two pin MS style connector or integrated cable. Replaces A & E. See pg.. SA High Temp. Accelerometer, available with two pin MS style connector. (8 & A ) See pg.. ST8E (pg.) or VTS (pg.8) Velocity Transmitter, available with flying leads, terminal blocks or MS connector. Additional Accessories -X, Magnetic Mounting Base, /- UNC,. x. x., /-8 UNF, painted steel, for use with any switch (A or 8 remote sensors for temporary applications only). 9-, Remote Indicator, Analog panel meter calibrated from to % of shutdown setpoint. For use with any with dependent - ma. Panel cutout dim:.(.) w x.(.) h. Weight:. kg ( lb.) Weight & Dimensions 898--XXXX, Splashproof Cable Assembly* Two () pin socket connector with integral, molded splash proof boot with. mm (. ) diameter polyurethane jacketed cable with twisted shielded pair wires. xxx.x = Cable length in meters. 9--XXXX-YYYY, Splashproof Cable Assembly w/stainless Steel Armor* Two () pin socket connector with integral, molded splash proof boot with. mm (.8 ) diameter, SST armored jacket with cable, twisted shielded pair wires. xxx.x = Armor length in meters. yyy.y = Cable length in meters. 898--, Connector Assembly Two () pin socket connector with cable strain relief, no cable. L-XXX, Three () pin socket MS style connector with cable. (8) 8L-XXX, Four () conductor cable required. (A) 98-, Cable only, Specify Length. (E) *Note: Constant current type accelerometers with pin MS connectors.. [.] 8 [.] Weight:. kg ( lbs) 8 [.]. [.] X Ø.9 [.] SENSITIVE AXIS 9. [.]. [.].9 [.]. [.] /- NPT www.metrix.com sales@metrix.com Sales & Service Tel: -- Fax: --8 /.