AEW Pulse Adapter. Building Technologies

Similar documents
AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

AEW36.2. Pulse Adapter. Siemeca AMR

AB Axis Industries. Use

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

RMZ790. Operator Unit. Building Technologies. Synco 700

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Interface converter for VAV compact controllers

Network node WTT56.. A6V _en--_c Building Technologies

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Mobile Data Collector

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Digital input modules

TXM1.8RB. TX-I/O Blinds module

Rotary actuators for ball valves

Room unit with PPS2 interface

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

Room unit with PPS2 interface

Air damper actuators

Rotary version, three-position control

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

Fast running actuators for air dampers

M-bus RF gateway. Meters and Energy Cost Allocation WTT563-0C0000

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

SEH62.1. Digital Time Switch

LON Module for Variable Speed Drive

Electromotoric actuators

BACnet/IP Web Interface

Room Temperature Controller

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Handheld Tool for VAV compact and modular controllers

M-Bus Central Unit. Use

Radiator Lockshield Valves ADN.. AEN..

Semi flush-mounted room temperature controllers with LCD

Extension module for lighting control

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

VAV modular controller

Heating Circuit Controller

Electromotive actuators for combi valves

9283P01. Extension module. Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Communication module to connect M-bus devices to POL6xx.xxx controllers.

ERF910. RF Repeater. Synco living

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RF adapter plugs, dimming

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

Super universal modules

Electromotoric actuators

Network nodes with gateway

Air Damper Actuators Modbus RTU

Electromotoric actuator

VAV compact controller

Immersion Temperature Sensors

Island bus expansion module

Power supply module, bus connection module

Room unit with PPS2 interface

WFZ16 WFZ166. Add-on radio module. Add-on modules for external water meters prepared for wireless transmission

24-hour room temperature controller

Heating Circuit Controller

Air Damper Actuators Modbus RTU

Rotary actuator for ball valves KNX / PL-Link

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Electrical Actuators

Electrical Actuators

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Web interface BACnet/IP

HOBO State Data Logger (UX90-001x) Manual

Operating instructions. Switching amplifier DN0210 DN / / 2015

Non-communicating room controllers

Solenvis SL80 Pulse to M-Bus Converters

MC 11 EB-2 Power supply cabinet with external bus, AC version

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

HOBO State Data Logger (UX90-001x) Manual

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Room unit with PPS2 interface

Operating instructions. Standstill monitor A / / 2011

USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL

MID approval no. DE-08-MI004-PTB004 Date of release

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

Switching module for AC V and up to three load stages, with manual switching

OCI Service Tool. Siemens Building Technologies HVAC Products. ACS plant operating software and OCI700 service interface

Airflow Pressure Sensor

Fume Hood Cable Sash Sensor

Electrical Actuators

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

Central control unit

Electrical actuators

Climatix programmable controller

Instruction Manual IF2004/USB. 4-Channel RS422/USB Converter

Accessories and options

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Temperature Controller

Non-communicating room controllers

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Installation Instructions

Impulse switching module

Transcription:

5 383 Pulse Adapter AEW310.2 The AEW310.2 pulse adapter acquires and handles the pulses from 1 or 2 consumption meters with pulse output and transmits the data to an M-Bus-network. For setting the parameters, the pulse adapter can be programmed via M-Bus interface before connecting to the network. Use The pulse adapter is a component of the M-Bus system. It is used when data of pulse output meters shall be collected by a M-bus system. Such devices can be meters for hot water, cold water, gas, electricity, etc. Functions Acquisition of the pulses delivered by the connected consumption meters Monitoring the connecting cable in the case of metering devices with NAMUR circuit Handling of pulses and storage of consumption data and set day values Transmission of data telegrams on demand to the M-bus master CE1N5383en Building Technologies

Type summary Standard version AEW310.2: Connection of 2 meters to the connecting cable by means of the cable connectors supplied with the unit. Ordering When ordering, please give type reference: AEW310.2 Equipment combinations When installing, the pulse adapter must be programmed with the data set delivered with the parameter setting software for the respective meter. If meters not contained in the meter data base shall be connected, a new data set must be requested. With the correct data set installed, the following types of meters can be connected: Water meters with pulse output Heat meters with pulse output Gas meters with pulse output Steam meters with pulse output Electricity meters with S0 interface (note: an additional S0 converter is required, e.g. z.b. IC-2, available by Nordwestdeutsche Zählerrevision Ing. Aug. Knemeyer GmbH & Co. KG, Heideweg 33, 49196 Bad Laer) Technical design The pulse adapter handles only pulses from potential-free pulse sources, according with the following specification: Pulse source limit values (if parameters are appropriately set) blue / red to AEW Electronic outputs (Open Collector, Open Drain) residual voltage when switched max. frequency min. pulse width < 0.7 V < 17 Hz 30 ms Mechanical switches (Reed contact, relays) bounce time max. frequency min. pulse width < 1 ms < 2 Hz 260 ms R2 R1 Mechanical switches with NAMUR circuits resistor R1 resistor R2 2.2 k 5.6 k The inputs are protected against overvoltages. Open collector outputs must be connected with the correct polarities: Channel 1: + blue, ground, Channel 2: + red, ground Power supply The pulse adapter is powered by a lithium battery which has a service life of 12 + 1 years. It cannot be changed in the field. During connection to M-bus the pulse adaptor will be powered from M-bus. Data transmission Data are transmitted inside M-Bus network to the central unit on demand.. Engineering notes Length of connecting cable For immunity reasons, the total length of the connecting cable may not exceed 10 m. 2/6

Mounting notes Electrostatic Sensitive Devices Mounting f All modules integrated in the meters are electrostatically endangered components. The freely accessible contacts (cable end, plug connector) are only partially protected against interference. Skilled personnel should avoid wearing polyester clothing and shoes with plastic soles as this type of clothing promotes electrostatic charging. Electrostatic charging of skilled personnel must be deflected when handling open components e.g. by touching an earthed piping system. When installing the meter, insert 1 wire of the pulse adapter s connecting cable and 1 wire of the meter s connecting cable into one of the cable connectors supplied with the unit. Then, squeeze the connector with a pair of pliers. This connection cannot be separated and offers degree of protection IP54. Only for AEW310.2/DK: With the housing cover open, insert the meter connecting cables with the O-ring from the rear of the unit into the cable strain relief and connect the cables to the terminal block. Then, close the housing. Commissioning notes The pulse adapter has to be programmed during installation. A first select the data set of the meter. Following data are determined: Type of medium (gas, water, etc.), physical variable (kwh, m 3, etc.) and pulse valency per input Type of pulse source (Reed switch, Reed switch with NAMUR, Open Collector, etc.) per input Then some additional data have to be programmed per input: Set day (1 set day per year), meter readings when commissioning the pulse adapter, meter number (identification number) The parameterization has to be done via wire-bound (M-Bus) before connecting adapter to the network. For parameterization, a laptop (Windows XP), the ACT20 parameter setting software and the WFZ.MBM programming adapter or USB-Toolset WHZ3.USB are required. Disposal The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Dispose of empty batteries in designated collection points. HVAC Products 14.12.2007 3/6

Technical data Operating voltage DC 3 V Life expectancy 12 +1 years Max. cable length pulse input 10 m Bus load 1 unit load (power supplied by M-Bus) Degree of protection IP 54 to EN 60 529 Safety class III to EN 60 950 Product standard EN 60950-1 Safety of information technology equipment Electromagnetic compatibility (Applications) For use in residential, commerce, light-industrial and industrial environments EU conformity (CE) CE1T5383xx *) Product environmental declaration (contains CE1E5383 *) data on RoHS compliance, materials compo sition, packaging, environmental benefit, disposal) Perm. ambient temperature Transport and storage Operation Weight 25 +60 C 0 55 C 0.3 kg *) The documents can be downloaded from http://siemens.com/bt/download. Connection diagrams INP 1 INP2 U1 Connection of any type of meters with pulse output blue red P1 P2 U1 AEW310.2 pulse adapter P1, P2 Meter with pulse output AC 230 V INP 1 INP2 U1 blue OUT INP N1 red OUT INP N2 Connection of electricity meters with S0 interface 1) e.g.ic-2 from Nordwestdeutsche Zählerrevision Ing. Aug. Knemeyer GmbH & Co. KG, Heideweg 33 49196 Bad Laer S0 P1 S0 P2 U1 AEW310.2 pulse adapter P1, P2 Electricity meters with pulse output N1, N2 SO pulse converter 1) 4/6

39,5 79 Dimensions 3,5 79 90 95,5 27,3 Connecting cable length is 350 mm. Dimensions in mm HVAC Products 14.12.2007 5/6

Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2007 Delivery and technical specifications subject to change 6/6