Type Differential pressure transducer

Similar documents
Type Differential pressure transducer

Type Differential pressure transducer

Type Static differential pressure transducers

Homepage > Products > Control Systems > Control system EASYLAB > Control panels > Type BE-SEG. Type BE-SEG

Control engineering information VARYCONTROL VAV Units VAV Compact flow rate controller BC0 BF0

Typ FMS FOR THE MONITORING OF VOLUME FLOWS

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TS. Type TS

Type EASYLAB TCU3 EASYLAB CONTROLLERS FOR THE MOST DEMANDING CONTROL ENGINEERING TASKS

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Type Dynamic differential pressure transducers

Operating Instructions Differential Pressure Transducer PS27

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Control components for VAV terminal units

Assembly instructions FMS-1 / FMS-2. Monitoring system

Portable low-pressure controller Model CPC2000

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Multi-range pressure and differential pressure transmitter

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Type EM-BAC-MOD BACNET AND MODBUS INTERFACE FOR EASYLAB CONTROLLERS AND ADAPTER MODULES

Instruction Manual PU/PI and PS10 Differential Pressure Transducers

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

Relative, and differential pressure transmitter type 699

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Control systems. Efficient room control

Instruction Manual P82R Differential Pressure Transducer with Root- Extracted Characteristic Curve

Differential Pressure Controller DPC 200

C-Flow Coriolis Mass Flow Meter

InBin-P Pressure switches from 5 Pa Pa

DP DP2500 DP0250

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

Control components for VAV terminal units

ProcessCalibrator Model CPH6000

Assembly and operating instructions. Control panel. EASYLAB BE-SEG-02 and BE-SEG-03

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

Pneumatic Control/Feedback

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

Portable pressure calibrator Model CPH7600

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

Room unit with PPS2 interface

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Pressure range mbar / mbar

Pneumatic Control/Feedback

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

Immersion Temperature Sensors

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

CDD4 Duct Carbon Dioxide Transmitter

L Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Precision thermometer Model CTR5000

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

VAV compact controller KNX / PL-Link

TEPI11 P/I signal converter

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

MID approval no. DE-08-MI004-PTB004 Date of release

Zone Pressure Touch (ZPT) Sensor - Standard Range

Airflow Pressure Sensor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Duct humidity and temperature sensor for all HVAC duct applications. Designed for control and monitoring applications.

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H

Zone Pressure Touch Sensor - Standard Range

Model VDL 115 Vacuum drying chambers for flammable solvents

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Electronic pressure switch with display For sanitary applications Model PSA-31

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Universal Controller

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Heating Circuit Controller

Room Temperature Controllers

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

CLEAN ROOM PANEL - CRP5

ProcessCalibrator Model CPH6000

InReg Volume flow controller Pa

Level sensor Stainless steel version Model RLT-1000, for industrial applications

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

TM-2100 Series Room Command Module

TECHNICAL MANUAL PRESSURE TRANSDUCER TYPE MLP

PHOENIX CONTACT - 11/2008

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Float Switches with Permanent Magnet For Horizontal Installation Model HIF

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

InCos-P Pressure sensor 20 Pa Pa

Functional data Factory settings Variable Setting Torque Inhibiting torque

TROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K

Pneumatic precision pressure controller Model CPC6000

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Precision pressure indicator 1- or 2-channel version Model CPG2500

PTU300 Combined Pressure, Humidity and Temperature Transmitter

F-SENSOR LOW AIR VELOCITY SENSOR

Transcription:

Homepage > Products > Control systems > Control system EASYLAB - LABCONTROL > Sensors > Type Differential pressure transducers Type Differential pressure transducer FOR THE DIFFERENTIAL PRESSURE RECORDING AND CONTROL IN COMBINATION WITH EASYLAB Differential pressure transducers based on the static measurement principle for the room or duct pressure control in combination with EASYLAB controllers TCU3 or LABCONTROL controllers TCU-LON-II Suitable for air and non-aggressive media For use in laboratories, clean rooms in the pharmaceutical and semiconductor industries, operating theatres, intensive care units, and offices with very demanding control requirements Constructions with calibration certificate to meet GMP requirements

APPLICATION Application Differential pressure transducer for the LABCONTROL system For the room or duct pressure control in combination with EASYLAB controllers TCU3 or with TCU-LON-II For the room and duct pressure monitoring in combination with monitoring systems TPM For use in laboratories, clean rooms in the pharmaceutical and semiconductor industries, operating theatres, intensive care units, and offices with very demanding control requirements DESCRIPTION Variants 699: Measuring range ± 50 or ± 100 Pa 699-LCD: Measuring range ± 50 or ± 100 Pa, with differential pressure display GB404: Measuring range ± 100 Pa GB604-CAL: Measuring range ± 100 Pa, with calibration certificat to meet GMP requirements (Good Manufacturing Practice) Choose a sufficient measuring range above/below the setpoint pressure Maintenance Zero point correction once per year is recommended TECHNICAL INFORMATION Function, Technical data, Specification text, Order code, Related products FUNCTION Functional description Static differential pressure transducers function according to the static differential pressure measurement principle. The

sensor is a cylinder that consists of two chambers (one for positive pressure and one for negative pressure) separated by a diaphragm. If there is equal pressure in both chambers, the diaphragm is in the middle between the chambers and is not deformed. If there is a pressure difference, the diaphragm deforms towards the chamber with the negative pressure. The degree by which the diaphragm deforms is a measure for the differential pressure. This is why the voltage signal is proportional to the differential pressure. Principle of operation room pressure control 1 Controller EASYLAB TCU3 or LABCONTROL TCU-LON-II In a lab, the room pressure transducer is typically linked to the supply air controller; in a clean room, it is linked to the extract air controller. TECHNICAL DATA Static differential pressure transducer 699

Supply voltage 24 V AC ± 15 % or 13.5 33 V DC Power rating 1 VA Output signal 0 10 V DC, 1 ma max. Media non-aggressive gases Measuring range ± 50 Pa factory set, can be changed to ± 100 Pa Measurement accuracy ± 2 % of full scale Overload protection for negative pressure measurement: 400 Pa at P1, for positive pressure measurement 10000 Pa at P1 Connections for tubes Ø 6.2 mm (for flexible tubes 6 mm) Operating temperature 0 70 C (non-condensing) IEC protection class III (protective extra-low voltage) Protection level IP 54 (with cover) EC conformity EMC according to 2004/108/EC Dimensions (B H T) 92 75 48 mm Weight 0.1 kg Static differential pressure transducer GB604

Supply voltage 24 V AC, 24 V DC ± 10 % (switching is possible) Power rating 1.8 VA Output signal 0 10 V DC; 2 ma max. Media non-aggressive gases Measuring range ± 100 Pa Measurement accuracy ± 0.5 % of full scale Maximum operating pressure 70 kpa Connections for tubes for flexible tubes 4 mm Operating temperature 20 to 65 C IEC protection class III (protective extra-low voltage) Protection level IP 54 EC conformity EMC according to 2004/108/EC Dimensions (B H T) 122 120 58 mm Weight 0.3 kg SPECIFICATION TEXT Differential pressure transducer for the LABCONTROL system, for the measurement of room or duct pressure. When the transducer is connected to a room controller, the supply air or extract air flow is controlled based on the differential pressure.

ORDER CODE Order example: PT-GB604-CAL Measuring range ±100 Pa, with calibration certificate PT Type Differential pressure transducer Variants 699 Measuring range ±50 or ±100 Pa 699-LCD GB604 Measuring range ±50 or ±100 Pa, with pressure display Measuring range ±100 Pa GB604-CAL Measuring range ±100 Pa, with calibration result Variants VARIANTS

699 Application Differential pressure transducer for the LABCONTROL system For the room or duct pressure control in combination with EASYLAB controllers TCU3 or with TCU-LON-II For the room and duct pressure monitoring in combination with monitoring systems TPM Variants 699: Measuring range ± 50 or ± 100 Pa 699-LCD: Measuring range ± 50 or ± 100 Pa, with differential pressure display Special characteristics Supply voltage: A.C. or D.C. voltage (ideal for EASYLAB with EM-TRF-USV) Adjustable measuring ranges Short circuit proof and with reverse voltage protection Parts and characteristics Plastic casing Connections for tubes Push button for zero point reset Adjustable measuring ranges 699-LCD: Differential pressure display Construction features Fixing points at the outside, for mounting to a wall or ceiling Materials and surfaces Transparent plastic casing GB604 Application Differential pressure transducer for the LABCONTROL system

For the room or duct pressure control in combination with EASYLAB controllers TCU3 or with TCU-LON-II For the room and duct pressure monitoring in combination with monitoring systems TPM Variants GB604: Measuring range ± 100 Pa GB604-CAL: Measuring range ± 100 Pa, with calibration certificat to meet GMP requirements (Good Manufacturing Practice) Special characteristics Supply voltage: A.C. or D.C. voltage, switching between A.C. and D.C. is possible Parts and characteristics Plastic casing Zero point potentiometer Construction features Fixing points at the inside, for mounting to a wall or ceiling Capacitive stainless steel measuring cell Materials and surfaces Plastic casing, light grey Differential pressure transducer 699

Differential pressure transducer GB 604 MF

Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-01-24 TROX GmbH

Homepage > Products > Control systems > Control system EASYLAB - LABCONTROL > Sensors > Type Differential pressure transducers Installation details INSTALLATION DETAILS Installation and commissioning Choose a suitable installation location (reference room with stable pressure) Ensure sufficient cross section and careful placing of the measuring tubes Connect the differential pressure transducer to the controller or monitoring system Supply voltage from the EASYLAB TCU3 controller or TCU-LON II (supply voltage for the differential pressure transducer must be equal to the supply voltage provided by the controller) Cosider the warm-up time of the sensor Do not install the sensor near sources of interference such as transformers, senders, motors, or heat sources Choose a stable installation location as shocks or vibration may distort the output signal Installation should be vertical, with connections pointing downwards; this installation position corresponds to the factory setup for calibration; it also prevents the ingress of condensate from the pressure tubes. Zero point correction required 699, Terminal connections Ο: Ground +: Supply voltage : Actual value signal Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-01-24 TROX GmbH

Homepage > Products > Control systems > Control system EASYLAB - LABCONTROL > Sensors > Type Differential pressure transducers GB604, Terminal connections 1 ~, +: Supply voltage 2, -: Ground, neutral 3 +: Actual value signal 4 : Actual value signal, ground Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-01-24 TROX GmbH

Homepage > Products > Control systems > Control system EASYLAB - LABCONTROL > Sensors > Type Differential pressure transducers TROX GmbH Online-Services Service-Hotlines Heinrich-Trox-Platz D-47504 Neukirchen-Vluyn Tel.: +49 (0)2845 202-0 Fax: +49 (0)2845 202-265 Order-Status (My TROX NET) TROX Academy Catalogue Download Your contact partner Online fault report BIM Sales Germany and technical consulting +49 (0)2845 202-0 Contact Technical service +49 (0)2845 202-400 Contact Home Contacts Imprint Delivery and payment terms Privacy Disclaimer 2018-01-24 TROX GmbH