Model Number Structure

Similar documents
G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Model Number Structure

Solid State Relays with Failure Detection Function

Model Number Structure

Model Number Structure

Model Number Structure

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Solid-state Timer H3YN

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Model Number Structure

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

Bulletin 700-SH Solid-State Relays. Overview/Product Selection. Bulletin 700-SH. Product Selection

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Voltage Current Front-mounting bracket

Safety Relay Unit (I/O Unit Type)

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

SRT2-ROC08, SRT2-ROC16

Thread length (overall length) material

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Inductive Proximity Sensor

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer

Model Number Structure

Switching Power Supply

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Inductive Proximity Sensor

Self-Powered Counters H7EC

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Model Number Structure

Model Number Structure

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Conductive Level Controller

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Model Number Structure

Solid-state Counter. Power supply Output No voltage input (short/open circuit) Voltage input (high/low voltage) 30 cps 1 kcps 30 cps 1 kcps AC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Three-phase Phase-sequence Phase-loss Relay

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

Model Number Structure

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM4JA01F current measurement relay RM4-J - range ma V AC

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

Terminal Relay types. Common note. Terminal Relay/Terminal SSR Mounted relays. Compact Terminal Relays/Terminal SSRs with four outputs

MOS FET Relay. Ordering Information. Application Examples G3VM- XN(F)/4N(F)

RE9RA21MW7 off-delay timing relay s V AC -

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Switch Mode Power Supply S8VT 120/240/480/960 W Models

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

DC562, digital input/output module,

Model Number Structure

DC561, digital input/output module,

RM4JA32MW current measurement relay RM4-J - range A V AC DC

Switching Power Supply

I/O delay. (0.32 in ±0.06 in)

S8VE (60/90/120/180/240-W Models)

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

Model Number Structure

DI572 Digital Input Module

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

DX561 Digital Input/Output Module

DI561 Digital Input Module

Solid-state Timers H3DK

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

Special-purpose Basic Switch

Programmable Relay ZEN V2 Units

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Solid-State Counter/Timer

Solid-state Timers H3DK

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Single-phase Voltage Relay

Transcription:

Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater control systems, and contributes to maintenance improvements by the user. Main detection items: SSR short-circuits and SSR open-circuits Alarm output possible to NPN/PNP-input devices. The failure-detection function is built-in and power is supplied from the main circuit power supply making wiring simple. Slim design (width: 22.5 mm) incorporating a heat sink. In addition to screw mounting, DIN track mounting is also possible. Certified by EC, UL, and CSA. Model Number Structure Model Number Legend G3PC-@@@-@ 1 2 3 4 5 1. Basic Model Name G3PC: SSR with Failure Detection Function 2. Rated Load Power Supply Voltage 2: 0 to 240 VAC 3. Rated Load Current 20: 20 A (carry current) 4. Terminal Type B: Screw terminals 5. Certification VD: Certified by UL, CSA, and VDE Ordering Information List of Models SSR Insulation method Zero cross function Indicators Rated output load Model number Phototriac coupler Yes Yes (See page 64) Note: When ordering, specify the rated input voltage. Accessories (Order Separately) Name Dimensions Model number Mounting Track 50 cm (l) 7.3 mm (t) PFP-50N 1 m (l) 7.3 mm (t) PFP-0N 1 m (l) 16 mm (t) PFP-0N2 20 A, 0 to 240 VAC (resistive load: AC, Class1) G3PC-220B-VD Solid State Relays with Failure Detection Function G3PC J-59

Specifications Ratings (at an Ambient Temperature of 25 C) Detection Power Supply Rated power supply voltage Operating voltage range Current consumption Operating Circuit Input method Rated input voltage Operating input voltage range Must operate voltage Must release voltage Input current 0 to 240 VAC (50/60 Hz) 75 to 264 VAC (50/60 Hz) 15 ma AC max. (at 200 VAC) Voltage input 12 to 24 VDC 9.6 to 30 VDC 9.6 VDC max. 1 VDC min. 7 ma DC max. (at rated input voltage) Main Circuit Rated load voltage 0 to 240 VAC (50/60 Hz) Operating voltage range 75 to 264 VDC (50/60 Hz) Rated carry current 20 A (Ta = 40) Minimum load current 0.1 A Inrush current resistance (peak value) 220 A (60 Hz, 1 cycle) Permissible (I 2 t) 260 A 2 s Applicable load 4 kw (at 200 VAC) (with Class-1 AC resistive load) Alarm Output Output OFF collector voltage Maximum carry current Output form 30 VDC max. 0.1 A Independent NPN open collector Characteristics Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Main circuit Output ON voltage drop 1.6 V rms max. OFF leakage current ma max. (at 200 VAC) Alarm output Output ON voltage drop 1.5 V max. OFF leakage current 0.1 ma max. Insulation resistance 0 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: to 55 to Hz, 0.35-mm single amplitude Shock resistance Destruction: 294 m/s 2 Ambient temperature Operating: -20 to 60 C (with no icing or condensation) Storage: -30 to 70 C (with no icing or condensation) Ambient humidity 45% to 85% Weight Approx. 300 g Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3); Certified by VDE EMC Emission EN55011 Group 1 Class B Immunity ESD IEC947-4-3, EN600-4-2 4 kv contact discharge 8 kv air discharge Immunity Electromagnetic IEC947-4-3, EN600-4-3 V/m (80 MHz to 1 GHz) Immunity EFT IEC947-4-3, EN600-4-4 2 kv AC power-signal line Immunity Surge transient IEC947-4-3, EN600-4-5 2 kv Immunity RF disturbance IEC947-4-3, EN600-4-6 V (0.15 to 80 MHz) Immunity Dips IEC947-4-3, EN600-4-11 J-60 Solid State Relays with Failure Detection Function G3PC

Engineering Data Input Voltage vs. Input Current Input Voltage vs. Input Impedance Input impedance (kω) Input current (ma) Ta = +25 C 25 8 6 Load Current vs. Ambient Temperature 20 15 One Cycle Surge Current: Non-repetitive The figure will be less than 1/2 the rated value for repetitive input. 250 200 150 4 2 5 0 50 0 0 0 20 30 40-20 0 20 40 60 80 0 30 50 0 300 500 1,000 3,000 5,000 Input voltage (V) Ambient temperature ( C) Energized time (ms) SSR Input impedance Load current (A) Inrush current (A. Peak) Input current Solid State Relays with Failure Detection Function G3PC J-61

Operation Failure Detection Function Conditions for SSR Failure Detection Failure mode (See note 1.) Operating input (between terminals A1 and A2) Detection time Alarm display (See note 3.) Alarm display (between terminals X1 and X2) (See note 3.) SSR short-circuit OFF 0.5 s max. (See note 2.) Red Open collector transistor SSR half-wave short-circuit OFF output SSR open-circuit ON SSR half-wave open-circuit ON Note: 1. The contents of each of the above failure modes is as follows: SSR short-circuit: SSR output circuit remains in the ON state. SSR half-wave short-circuit: SSR output circuit remains in the ON state in one direction. SSR open-circuit: SSR output circuit remains in the OFF state. SSR half-wave open-circuit: SSR output circuit remains in the OFF state in one direction. In addition to the failure modes listed above, detection of circuit disconnections for the load circuit is also possible. (As a rough guide, circuit disconnection will be detected if the load impedance is greater than or equal to 1 MΩ.) 2. The same power supply is used for both the detection and for the output circuit and so detection is not performed during power interruptions. 3. If power supply (terminal 3) is in the open state, the SSR will still turn ON and OFF in the same way but the failure detection function and alarm display will not operate properly. Connection Diagrams (Main Circuit) The following diagrams show the applicable load connection configurations for SSR failure detection. Single Phase 3-phase Star Connection 3-phase Delta Connection (3-phase, 2-wire Switching) 3-phase V Connection G3PC G3PC G3PC G3PC G3PC G3PC G3PC G3PC Note: 1. With 3-phase connection, so that the power supply voltage is applied between the G3PC s terminals 1/L1 and 3, connect the desired phase to terminal 3. 2. Above mentioned products are 200V only. They are not suitable for three-phase 400V, but for three-phase 220V only. Timing Chart Main circuit power supply (load side) SSR failure detection SSR ON normally SSR OFF normally SSR short-circuit Reset (See note.) SSR open-circuit Reset (See note.) Circuit disconnection detection on the load side Load circuit disconnection Reset (See note.) Operating input (between terminals A1 and A2) Input LED (yellow) Load current RDY/ALM LED (Green: ; Red: ) Alarm output (between terminals X1 and X2) Note: After failure detection, if the detection conditions differ to the conditions given under Conditions for SSR Failure Detection, alarm output is reset. J-62 Solid State Relays with Failure Detection Function G3PC

Dimensions G3PC-220B-VD 130 max. 114.4 Terminal cover 22.5 max. Tow, 4.6 dia. Mounting Holes Three, 4.5 dia. or M4 13.5 68 8.5x3 0 max. 90±0.2 80 90±0.3 4.6x5.6 elliptic hole 13±0.3 Accessories (Order Separately) Mounting Tracks PFP-0N, PFP-50N 84.2 Note The above diagram is for when the terminal cover is open. PFP-0N2 Note The above diagram is for when the terminal cover is closed. 4.5 15 25 25 25 25 1,000 (500) (see note) 7.3±0.15 15 (5) (see note) 35±0.3 27±0.15 4.5 15 25 25 1,000 25 25 15 16 35±0.3 27 24 29.2 1 1.5 Note Values in parentheses indicate dimensions for the PFP-50N. SSR Solid State Relays with Failure Detection Function G3PC J-63

Installation External Specifications Terminal Arrangement Terminal name Terminal number Screw size Main circuit terminals 1/L1, 2/T1 M4 (output) Detection power supply 3 terminal (input) Operating circuit terminals A1, A2 M3.5 (input) Alarm output terminals (output) X1, X2 Indicators Name Symbol Color Meaning Status indicators RDY Green SSR normal ALM Red SSR failure detection and circuit disconnection detection Input indicator INPUT Yellow Operating Note: The same indicator is used as both the power supply indicator and the alarm indicator. Connection Example Appearance 1/L1 3 A1(IN+) A2(IN ) X1(ALM+) X2(ALM ) 2/T1 RDY/ALM INPUT (See note 1.) Display Labels Voltage output for Temperature Controller, sequencer 12 to 24 VDC 1 3 A1 IN A2 L1 AC Input for Temperature Controller, sequencer X1 ALM X2 30 VDC min. 2 T1 (See note 2.) Note: 1. If the detection power supply terminal (terminal 3) is not connected, failure detection is not performed and so be sure to connect this terminal. 2. If the load is connected to terminal 1/L1, failure detection may not operate correctly and so connect the load to terminal 2/T1. 3. With inductive loads (relay coil, etc.), connect back-current prevention diodes to both sides of the load. J-64 Solid State Relays with Failure Detection Function G3PC

Safety Precautions Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Mounting Method DIN Track Mounting When mounting to a DIN track, mount the G3PC until it clicks into place, otherwise it become loose during use and fall. Fix both ends with end plates. Panel Mounting When mounting directly to a panel, observe the following conditions: Screw diameter: M4 Tightening torque: 0.98 to 1.47 N m Make sure that all lead wires are of a thickness appropriate for the current. The output terminals are charged, and touching them may result in electric shock, even when the G3PC is OFF. Separate the outputs from the power supply by installing a circuit-breaker at a higher level in the circuit. Tightening Torque Be sure to tighten the screws to the specified torques given below. Not doing so may result in malfunction. Terminal number Screw terminal Tightening torque diameter A1, A2, X1, X2 M3.5 0.59 to 1.18 N m 1/L1, 2/T1, 3 M4 0.98 to 1.47 N m Vertical Mounting Horizontal Mounting Panel Vertical direction Panel Note: Use the G3PC at a load current of 50% of the rated load current when it is mounted horizontally. Close Mounting Wiring duct 80 mm min. 5 mm Wiring duct 80 mm min. Note: Use the G3PC at a load current of 80% of the rated load current when it is mounted side by side. Wiring When using crimp terminals, observe the terminal clearances shown below. SSR Main Circuit Power Supply (Terminals 1 to 3) 7.0 Operating Input/Alarm Output (Terminals A1, A2, X1, and X2) 12.4 M3.5 Solid State Relays with Failure Detection Function G3PC J-65

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J127-E1-03 In the interest of product improvement, specifications are subject to change without notice. J-66 Solid State Relays with Failure Detection Function G3PC