Electrostatic Field Meter EFM 022

Similar documents
MANUAL. Electrostatic Field Meter EFM 022. System Prof. Dr.-Ing. Hans Kleinwächter

ELECTROSTATIC FIELDMETER

Wrist Strap & Shoe Tester WST 100

TEST AND MEASUREMENT SRM 200 SRM 200/EFM 51 STARTERKIT

OPERATIONS MANUAL ACL 350 DIGITAL STATIC LOCATOR

ACL 350 Digital Static Locator

MANUAL. Handgelenksband WST 100. Handgelenksband- und Schuhtester. performance test for Electrostatic Wrist Straps and Conductive Shoes

User's Manual. Autoranging Datalogging Insulation Tester (Megohmmeter) with PC Interface. Model

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

2 in 1 LAN Tester and Multimeter Model:

711 Charge Analyzer Operation and Maintenance

BC-7000 Field Calibration Procedure 55 AMP

BC-9000 Field Calibration Procedure CF1_FIELDCAL_BC9000 Revised 03/16/2013

Charge Analyzer 711. Operating Instructions. August

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

38 MHz Passive Voltage Probe R&S RT-ZP1X

BC-5000 Field Calibration Procedure 55 AMP

PGT 120. Personnel Grounding Tester. Wrist Strap and Footwear Tester. Users's Manual

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

TETRIS 2500 High Impedance Active Probe. Instruction Manual

CHARGED PLATE ANALYZER CHARGED PLATE ANALYZER KIT

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

RS Stock No Instruction Manual RS Input Data Logging Thermometer

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

User Guide True RMS Multimeter Extech EX205T

Net-Ritef Continuity and Wiremap Tester Trace-Ritef Tone Generator and Amplified Tone Tracer User's Guide.

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

To connect the AC adapter:

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

TC100 Precision Thermocouple Calibrator

Instruction Manual RS-1660

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

OPERATING INSTRUCTION

Model A Mini AC/DC Clamp Meter. User's Guide

RT-500 Megohmmeter Accurate - Best Value Today

Autoranging True RMS Multimeter User Manual

Zero Volt Monitor Installation, Operation and Maintenance

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

Light intensity measuring instrument

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

3M Static Sensor 718, 3M Air Ionizer Test Kit 718A. User s Guide

ESD protection for LED systems

HOBO State Data Logger (UX90-001x) Manual

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

HOBO Motor On/Off Data Logger (UX90-004x) Manual

650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight. user manual

Operating manual LRD 325. Conductivity measuring cell to be installed in pipelines

Helpline No. UK/Northern Ireland Rep. Ireland Web Support Model Number 82069

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Talk-N-Tracef Communication and Tracing Set. User's Guide.

OPERATION MANUAL ESD - GENERATORS

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

ACL 380 Resistivity Meter

MEASURING AND TESTING INSTRUMENTS

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Start Stop Relay ehb5040x

DPM Digital DC Power Meter with Data logging capability. User Manual

POCKET MULTIMETER Model No: MM18

Elecraft K3 KREF3 Output Level Modification

700 Series 200 Amp Clamp Meters

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Handbook ASI-PRG-ADR. AS-Interface Addressing Device. Festo AG & Co de 0004a

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

LSL250. Laser light! Do not stare into the beam or view directly with magnifiers. Class 2 laser EN :

Operating Manual. FSM-2 Field Strength Measuring Gauge Part Number

Replacing the Gateway M305 Optical Drive

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

English. Instruction and operation manual S 505. Dew point meter (portable)

HT-1A Dual Band CW QRP Transceiver. User Manual

Replacing the Gateway M275 Keyboard

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual

HOBO State Data Logger (UX90-001x) Manual

User s Guide. 600A AC Clamp Meter. Model 38387

User's Guide. Extech AM A AC Analog Clamp Meter

0.01kV (0 to ±0.99 kv)

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

light-drive elite Setup Manual

User's Guide. Digital Multimeter. Model MN42

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

Display Panel BAT 100 LSN. en Operation Guide

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Visit us at

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

RGU Main Control Board Replacement Firmware Version 3.01

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

Junos WebApp Secure 5.0 Hardware Guide

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Digital Multimeter User's Manual

KEZ-c1TR28V12XIR HD-TVI 720p Low Light Varifocal IP66 EXIR Turret Cameras with OSD, CVBS Test Output and UTC Control

Electrostatic Fieldmeter Model 775

Transcription:

Manual Electrostatic Field Meter EFM 022 System Prof. Dr.-Ing. Hans Kleinwächter

Manual EFM 022 2 Contents 1. General Information on Electrostatics... 3 1.1. Origin of Electrostatic Charge. 3 2. Product Description... 3 2.1. Specifications.. 4 2.2. Measuring Range. 4 2.3. Caption 4 3. Manual... 5 3.1. Measuring Principle 5 3.2. Application Areas 5 3.3. Button Features 5 3.4. Initiation.. 5 3.5. Hold. 5 3.6. Measurement Ranges.. 6 3.7. Changing the Measurement Distance.. 6 3.8. Spacers. 7 3.9. Display. 7 3.10. Battery Monitoring 7 3.11. Grounding.. 7 4. Maintenance.. 8 4.1. Battery Replacement 8 4.2. Zero Point 8 4.3. Accuracy Adjustment.. 8 4.4. Guarantee Items.. 9 4.5. Disposal of Batteries and Accumulators.. 9 4.6. Disposal of Device.. 9 5. Scope of Delivery.. 10 6. Warning Notices 10 7. Calibration. 10

Manual EFM 022 3 1. General Information on Electrostatics Nowadays ESD 1 is a problem at many workstations, because modern microelectronics 2 is easily destroyed by the sequels of ESD. Other branches of industry like e.g. telecommunications, plastics, and explosive material industry are also heavily affected by ESD. ESD causes losses of time as well as high financial losses and can endanger the human health. Charges of over 10000 Volts can emerge on people, clothes, materials and equipment. Devices that are sensitive to electrostatics can be damaged by electrostatic discharges of less than 100 Volts. Charges of 3000 Volts and more can cause sparks. In endangered areas that can cause explosions. 1.1. Origin of Electrostatic Charge Triboelectricity 3 is caused by attrition of different materials. Electrons are transferred from one material to the other. As electrons are charged negative the material that releases electrons is charged positive. The material admitting electrons is charged negative. There are different ways to avoid or to discharge electrostatic charges. But to find an effective and reasonable solution first of all the emergence, amount and polarity of the charge have to be found. Our devices are suitable for that purpose and for the supervision of favored charge. 2. Product Description The unit is housed into an EMV plastic enclosure. The influence electrode is star shaped. In front of it in a small distance apart a rotating grounded modulation propeller with the same shape as the electrode is located. The influence electrode is enclosed by a ring electrode system that is used as mechanical shield for the propeller wheel and the sensor plate. A 2 x 12 digit alphanumeric LC display is located at the front of the device. The device has an integrated micro computer with the following functions: Conversion of the measured field intensity over the adjusted measurement distance to the charge in Volts One button operation Permanent supervision of the battery voltage with automatic shut-down Charge plate mode 4 1 electrostatic discharge 3 Greek: tribeia = friction 2 integrated circuits 4 with optional CPS kit

Manual EFM 022 4 2.1. Specifications Dimensions(L x W x H): Approx. 70mm x 122mm x 26mm Weight: Approx. 130g Calibration in parallel plate capacitor: 200mm x 200mm, distance 20mm Calibration accuracy: <5% Battery: 9V alkaline or NiMH battery Operating time: Approx. 10h with alkaline battery 2.2. Measuring Range Distance Measuring range Max. resolution 1cm 0 10kV 1V 2cm 0 20kV 2V 5cm 0 50kV 5V 10cm 0 100kV 10V 20cm 0 200kV 20V 2.3. Caption 1 6 2 3 7 4 8 5 9 1 Cover cap 6 Spacer 2 Accuracy adjustment trimmer 7 Zero point trimmer 3 Modulator system 8 Alphanumeric LCD display 4 Button <function/on> 9 Battery case(on the back) 5 Grounding jack

Manual EFM 022 5 3. Manual 3.1. Measuring Principle The electrostatic field meter is a parametric amplifier. The electric field influences a current proportional to the electrostatic field. The current is amplified and measured with a selective amplifier. No energy is taken from the field over time means. No radioactive matters are used! 3.2. Application Areas Detection and control of electrostatic field resp. charges, Measuring of electric charges, Electrostatic charges, Very high-resistance voltage sources. 3.3. Button Features Power On Press <function/on> 1 time shortly Hold Press <function/on> 1 time shortly to switch on or off Distance Press <function/on> until change cm appears Press <function/on> 1 time shortly to change to a new distance or to CPS mode, wait approx. 2s to select the displayed function Power Off Press <function/on> 2 times in quick succession 3.4. Initiation By pressing the <function/on> button on the front panel the device is switched on. By pressing the <function/on> button twice in normal operation the device is switched off. Power on device firstly then the black cover cap on the modulator system has to be removed before measuring! If the <function/on> button is not pressed for about 3.5 min, the device switches off to save power and to prevent discharge of the accumulator. 3.5. Hold The device has a hold function to freeze the current measuring value. By pressing the <function/on> one time the value measured at that time remains in the display. The upper line shows Hold and in the bottom line the result is displayed. By pressing the <function/on> button again the hold function is switched off and the current result is displayed.

Manual EFM 022 6 3.6. Measurement Ranges After switching the device on the distance selected distance is 2cm. If you want to measure with that distance 5 you just have to place the device 2cm in front of the object to be measured. For most cases this distance is ideal because charges up to 16kV can be measured (see specifications). But there are cases in which the measuring distance should be changed. In case of very high charges or very rough surfaces the distance should be increased. In case of very low charges the smallest distance (1cm) should be selected. 3.7. Changing the Measurement Distance Press <function/on> until the lower line shows change distance (approx. 2sec). In the upper line the current distance is shown in cm. By pressing <function/on> the distance can be changed in the following order: 2cm 5cm 10cm 20cm CPS 1cm 2cm Mode To select the displayed value wait (without pressing <function/on> ) until the current measurement value is displayed in the bottom line. In the upper line the new distance is displayed. Continue measuring using the new distance. The distance is measured from the plate behind the modulator blade. The plate is located 6.4mm in front of the device front plane. After switching the device off and on always 2cm distance are selected! The electrostatic field meter measures the direct voltage field strength. Over the selected distance the field strength is converted to the charge on the object: Example: displayed value [V] = field strength [V/m] x distance [m] With a distance of 10cm and a displayed value of 1000V the field strength is: E = 1000V / 0.1m = 10000V/m 5 entspricht dem mitgelieferten Abstandhalter

Manual EFM 022 7 3.8. Spacers The shipment includes 2 spacers for the measurement distance 2cm. Those can be screwed in the front plate. 3.9. Display The display is a double-spaced alphanumeric LCD display with 12 digits in each row (2 x 12). In the upper line the selected distance is displayed in cm. In the bottom line the measured charge is displayed in Volt from 999V on the display changes to kv display. The displayed value is always triple-digit: Examples: 578V 3,85kV 24,0kV 274kV If overflow is displayed, the distance has to be increased 3.10. Battery Monitoring The device has permanent battery voltage monitoring. By undercutting a battery voltage of 7.6V the upper line displays Low Battery!. In that case the 9V battery has to be charged or renewed. By undercutting 7.1V the display shows auto off for about 2s and the device powers off to prevent further damage. Attention: Exclusively use 9V alkaline or NiMH batteries. Rechargeable batteries have to be charged outside the device in a suited battery charger. Please pay attention to manufacturer instructions! Used batteries can be returned to us or have to be disposed professionally. 3.11. Grounding The device has to be grounded properly to measure the amount and the polarity of an electrostatic field. For that purpose the device has to be connected to ground by using the grounding jack (5). Grounding the device by a grounded person (e.g. over conductive shoes or wrist strap) touching the grounding jack suffices under most circumstances.

Manual EFM 022 8 4. Maintenance The modulator system or parts of it must not be touched. Those parts have to be protected of dust, isolating impurity layers, color or paint haze and condensate. If required the modulator system can be cleaned with ethyl alcohol and a lint-free cotton cloth. 4.1. Battery Replacement When Low Battery appears in the display the 9V battery has to be charged (accumulator) or renewed (alkaline). For this the device has to be turned off and the battery case has to be opened by sliding down. The battery has to be taken out and the battery clip pulled off. The clip needs to be plugged to the new battery and put back with the battery into the device. Finally the battery case should be closed again. 4.2. Zero Point Under normal circumstances a zero point adjustment is not necessary. If the device does not show U = 000V while the modulator system is screened (e.g. mounted cover cap) the zero point can be adjusted using the trimmer (7) on the right side of the device. The last digit of the display may be ignored as that error is smaller than the admissible tolerance. Trimmer (7) On the right side of device 4.3. Accuracy Adjustment If there is a big measuring error when calibrating the device, the accuracy adjustment is available by using the trimmer (2) which is under QC label on the left side of the device. There need a reference DC voltage output equipment to calibrate the device. Adjusting accuracy into +/-5% of reference DC voltage by rotating trimmer (2). Trimmer (2) On the left side of device

Manual EFM 022 9 4.4. Guarantee Items We provide a 12 month guarantee in case of proper application according to the manual. Excluded of the guarantee are: The battery resp. the accumulator, damage by electric shock, wrong grounding and mechanical damage of the device. The guarantee expires if the device was opened. 4.5. Batteries and accumulators are not allowed in the household waste! Every consumer must by law, dispose of all batteries and accumulators at a municipal or commercial collection center, free of charge. Thereby, the disposal will be environmentally friendly. Batteries and accumulators are marked with the following symbol: This crossed out garbage bin means that you may not dispose of batteries and Accumulators in the household waste. Under this sign you may also find Sometimes, in addition, the following abbreviations related to the materials Contents: Pb = lead, Cd = cadmium and Hg = mercury. 4.6. Electrical and electronic equipment are not allowed in the household waste! When the equipment is not used anymore, every consumer must by law, separate the equipment from the household waste and bring it to a municipal collection center. Old electrical equipment is accepted there free of charge. This will ensure that the old equipment is handled by experts and it will avoid negative impact on the environment. Electrical equipment is marked with the following symbol: The black bar under the crossed out garbage bin indicates that the equipment was put into circulation after August 13, 2005.

Manual EFM 022 10 5. Scope of Delivery The basic equipment of the electrostatic field meter includes the following components: Soft bag Electrostatic field meter 9V alkaline battery Grounding cable with alligator clip Manual Certificate of calibration Optional: Carrying case 9V NiMH accumulators Plug-in charger EC109 6. Warning Notices The electrostatic field meter must not be opened. By opening the guarantee expires! The electrostatic field meter must not be used in explosive areas. No admission for explosive area! If high charges are possible the electrostatic field meter must be grounded. An adequate distance must be kept! Flashovers on the modulator system must be avoided! The use of the device in power plants or comparable areas is prohibited! The device can not measure alternating fields > 1Hz! 7. Calibration A check of the measurement values is recommended annually. 2011 - Kleinwächter GmbH