Philips MRI Protocol Dump Created on Comment Software Stream

Similar documents
ADNI, ADNI_QH, SURVEY. Geometry. connection

ADNI GO - ADNI 2 Human7 (9) 38:30.1

SIEMENS MAGNETOM Avanto syngo MR B15

SIEMENS MAGNETOM Avanto syngo MR B15

SIEMENS MAGNETOM Verio syngo MR B17

COBRE Scan Information

SIEMENS MAGNETOM Verio syngo MR B15V

SIEMENS MAGNETOM Skyra syngo MR D13

Page 1 of 9. Protocol: adult_other_adni3basichumanprotocol25x_ _ _1. 3 Plane Localizer. 3 Plane Localizer PATIENT POSITION

SIEMENS MAGNETOM TrioTim syngo MR B17

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2008

SIEMENS MAGNETOM Symphony syngo MR A30

HST.583 Functional Magnetic Resonance Imaging: Data Acquisition and Analysis Fall 2006

SOP: Brain MRI Inital version Gorm Greisen. CONTENT 1.0 Timing of Brain MRI Informed consent...1

Orthopedic MRI Protocols. Philips Panorama HFO

Lab Location: MRI, B2, Cardinal Carter Wing, St. Michael s Hospital, 30 Bond Street

Dynamic Contrast enhanced MRA

MRI. When to use What sequences. Outline 2012/09/19. Sequence: Definition. Basic Principles: Step 2. Basic Principles: Step 1. Govind Chavhan, MD

MRI image formation 8/3/2016. Disclosure. Outlines. Chen Lin, PhD DABR 3. Indiana University School of Medicine and Indiana University Health

MRI Physics II: Gradients, Imaging

Fast Imaging Trajectories: Non-Cartesian Sampling (1)

Siemens AG, Healthcare Sector. syngo MR D13 0. Supplement - Parameters and image text 0.

A Virtual MR Scanner for Education

Role of Parallel Imaging in High Field Functional MRI

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Diffusion MRI Acquisition. Karla Miller FMRIB Centre, University of Oxford

Tina Pavlin 12 March 2013

CHAPTER 9: Magnetic Susceptibility Effects in High Field MRI

fmri Image Preprocessing

Functional MRI. Jerry Allison, Ph. D. Medical College of Georgia

Fast Imaging UCLA. Class Business. Class Business. Daniel B. Ennis, Ph.D. Magnetic Resonance Research Labs. Tuesday (3/7) from 6-9pm HW #1 HW #2

An Introduction to Image Reconstruction, Processing, and their Effects in FMRI

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

TOPICS 2/5/2006 8:17 PM. 2D Acquisition 3D Acquisition

Field Maps. 1 Field Map Acquisition. John Pauly. October 5, 2005

Head motion in diffusion MRI

New Technology Allows Multiple Image Contrasts in a Single Scan

8/11/2009. Common Areas of Motion Problem. Motion Compensation Techniques and Applications. Type of Motion. What s your problem

Following on from the two previous chapters, which considered the model of the

Lucy Phantom MR Grid Evaluation

MR Advance Techniques. Vascular Imaging. Class III

Scan Acceleration with Rapid Gradient-Echo

Breast MRI Accreditation Program Clinical Image Quality Guide

I.e. Sex differences in child appetitive traits and Eating in the Absence of Hunger:

MRI Hot Topics Motion Correction for MR Imaging. medical

surface Image reconstruction: 2D Fourier Transform

Patient Specific. Protocol Identification Number (PID) Must be on each individual. MRI Image

SPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney.

(a Scrhon5 R2iwd b. P)jc%z 5. ivcr3. 1. I. ZOms Xn,s. 1E IDrAS boms. EE225E/BIOE265 Spring 2013 Principles of MRI. Assignment 8 Solutions

Module 5: Dynamic Imaging and Phase Sharing. (true-fisp, TRICKS, CAPR, DISTAL, DISCO, HYPR) Review. Improving Temporal Resolution.

Correction for EPI Distortions Using Multi-Echo Gradient-Echo Imaging

Module 4. K-Space Symmetry. Review. K-Space Review. K-Space Symmetry. Partial or Fractional Echo. Half or Partial Fourier HASTE

Error! Bookmark not defined. Error! Bookmark not defined.

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

Sources of Distortion in Functional MRI Data

Midterm Review

A Spatio-temporal Denoising Approach based on Total Variation Regularization for Arterial Spin Labeling

MRI Imaging Options. Frank R. Korosec, Ph.D. Departments of Radiology and Medical Physics University of Wisconsin Madison

Motion Artifacts and Suppression in MRI At a Glance

SPM8 for Basic and Clinical Investigators. Preprocessing. fmri Preprocessing

QIBA PET Amyloid BC March 11, Agenda

Exam 8N080 - Introduction MRI

SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER

Accelerated MRI Techniques: Basics of Parallel Imaging and Compressed Sensing

Imaging Notes, Part IV

Basic fmri Design and Analysis. Preprocessing

Cocozza S., et al. : ALTERATIONS OF FUNCTIONAL CONNECTIVITY OF THE MOTOR CORTEX IN FABRY'S DISEASE: AN RS-FMRI STUDY

45 µm polystyrene bead embedded in scattering tissue phantom. (a,b) raw images under oblique

Sampling, Ordering, Interleaving

Short Tutorial for ODIN, the Object-oriented Development Interface for NMR

Functional MRI in Clinical Research and Practice Preprocessing

Magnetic Resonance Angiography

Super-resolution Reconstruction of Fetal Brain MRI

Digital Imaging and Communications in Medicine (DICOM) Supplement 116: 3D X-Ray Storage SOP Class

EPI Data Are Acquired Serially. EPI Data Are Acquired Serially 10/23/2011. Functional Connectivity Preprocessing. fmri Preprocessing

SPM8 for Basic and Clinical Investigators. Preprocessing

Sparse sampling in MRI: From basic theory to clinical application. R. Marc Lebel, PhD Department of Electrical Engineering Department of Radiology

XI Signal-to-Noise (SNR)

Dynamic Autocalibrated Parallel Imaging Using Temporal GRAPPA (TGRAPPA)

High Spatial Resolution EPI Using an Odd Number of Interleaves

M R I Physics Course

3-D Gradient Shimming

7D Cardiac Flow MRI: Techniques & Automation of Reconstruction

VXRE Reconstruction Software Manual

This Time. fmri Data analysis

Sampling, Ordering, Interleaving

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Parallel Imaging. Marcin.

Marquette University Iain P. Bruce Marquette University, M. Muge Karaman Marquette University

MB-EPI PCASL. Release Notes for Version February 2015

Single Breath-hold Abdominal T 1 Mapping using 3-D Cartesian Sampling and Spatiotemporally Constrained Reconstruction

A Novel Iterative Thresholding Algorithm for Compressed Sensing Reconstruction of Quantitative MRI Parameters from Insufficient Data

3D3C & 2D3D Velocity Measurements Using Magnetic Resonance Velocimetry

Outline: Contrast-enhanced MRA

Applications Guide for Interleaved

Statistical Analysis of Image Reconstructed Fully-Sampled and Sub-Sampled fmri Data

A Tutorial Guide to Tribology Plug-in

Optimizing MR Scan Design for Parameter Estimation (with Application to T 1, T 2 Relaxometry)

Transcription:

Page 1 of 5 Philips MRI Protocol Dump Created on 2/17/2011 4:11:01 PM Comment Created by ExamCard_to_XML with inputs: "J:\ADNI GO - ADNI 2 Phantom5.ExamCard" on system (BU SCHOOL OF MEDICINE :: 192.168.71.10) Software Stream 2.6.3.4 Expand All Collapse All (1) (1) (4) Hospital (1) ADNI GO - ADNI 2 Phantom5 (4) 13:38.4 3 Plane Localizer 00:31.5 Ref_HC_8 00:29.7 QC Phantom MPRAGE 05:34.2 QC Phantom fmri 07:03.0

Page 2 of 5 Hospital (1) ADNI GO - ADNI 2 Phantom5 (4) 13:38.4 3 Plane Localizer 00:31.5 Total scan duration 00:31.5 Act. TR/TE (ms) 11 / 4.6 ACQ matrix M x P 256 x 128 ACQ voxel MPS (mm) 0.98 / 1.95 / 10.0 REC voxel MPS (mm) 0.98 / 0.98 / 10.0 Scan percentage (%) 50 TFE shots 2 TFE dur. shot / acq (ms) 1166.0 / 712.4 TFE shot interval (ms) 1166.044 Min. TI delay 402.423 Act. WFS (pix) / 3.496 / 124.3 Min. WFS (pix) / Max. 1.045 / 415.8 Min. TR/TE (ms) 11 / 2.4 SAR / head < 9 % / 0.3 Whole body / level 0.0 / rmal B1 rms [ut] 0.6881929 PNS / level 16 % / rmal Sound Pressure Level 1.293028 Cardiac synchronization Navigator respiratory Flow fmri echo stabilisation Motion smoothing Angio / Contrast enh. Quantitative flow Dynamic study Arterial Spin labeling Preparation phases auto Manual Offset Freq. B0 field map/dixon B1 field map MIP/MPR Images M,,, Calculated images,,, Save raw data Hardcopy protocol Ringing filtering rectangular Geometry correction default Multi coil Homogeneity correction ne CLEAR FOV FH (mm) 250 AP (mm) 250 stack RL (mm) 50 Voxel size FH (mm) 0.9765625 AP (mm) 1.953125 Slice thickness (mm) 10 Recon voxel size (mm) 0.9765625 Fold-over suppression Reconstruction matrix 256 SENSE k-t BLAST Stacks 3 current A type parallel slices 3 slice gap user defined gap (mm) 10 slice orientation sagittal fat shift direction F Slice scan order default Stack scan order ascend Move table per stack Stack alignment Stack display order PlanAlign Interactive positioning Stacks 3 current A -20 FH (H=+mm) 20 Ang. AP (deg) 0 RL (deg) 0 FH (deg) 0 Scan mode M2D Contrast enhancement T1 Fast Imaging mode TFE shot mode multishot TFE factor 64 startup echoes default shot interval shortest profile order linear partial echo yes shifted echo TE in-phase (ms) 4.602995 Flip angle (deg) 15 TR shortest Halfscan (pixels) 3.5 Shim default Fat suppression Water suppression TFE prepulse invert slice selection shared delay user defined (ms) 800 PSIR MTC T2prep Research prepulse Diffusion mode PNS mode low Gradient mode regular SofTone mode

Page 3 of 5 Hospital (1) ADNI GO - ADNI 2 Phantom5 (4) 13:38.4 Ref_HC_8 00:29.7 Total scan duration 00:29.7 Act. TR/TE (ms) 4.0 / 0.79 ACQ matrix M x P 96 x 49 ACQ voxel MPS (mm) 4.69 / 6.04 / 6.00 REC voxel MPS (mm) 4.69 / 4.69 / 3.00 Scan percentage (%) 77.60416 Packages 1 Act. WFS (pix) / 0.215 / 2025.1 Min. WFS (pix) / Max. 0.209 / 2083.3 SAR / local torso < 2 % / 0.2 Whole body / level 0.0 / rmal B1 rms [ut] 0.2545432 PNS / level 30 % / rmal Sound Pressure Level 17.64667

Page 4 of 5 Hospital (1) ADNI GO - ADNI 2 Phantom5 (4) 13:38.4 QC Phantom MPRAGE 05:34.2 Total scan duration 05:34.2 Act. TR/TE (ms) 6.7 / 3.1 ACQ matrix M x P 244 x 228 ACQ voxel MPS (mm) 1.11 / 1.11 / 1.30 REC voxel MPS (mm) 1.05 / 1.05 / 1.30 Scan percentage (%) 100 TFE factor 228 TFE dur. shot / acq (ms) 1671.8 / 1525.0 Min. TI delay 796.2259 Act. WFS (pix) / 1.811 / 239.9 Min. WFS (pix) / Max. 0.464 / 936.1 SAR / head < 10 % / 0.3 Whole body / level 0.0 / rmal B1 rms [ut] 0.7446711 PNS / level 60 % / rmal Sound Pressure Level 13.38483 Cardiac synchronization Navigator respiratory Flow fmri echo stabilisation Motion smoothing Angio / Contrast enh. Quantitative flow CENTRA Dynamic study Arterial Spin labeling Preparation phases auto Manual Offset Freq. B0 field map/dixon B1 field map MIP/MPR Images M,,, Calculated images,,, Save raw data Hardcopy protocol Ringing filtering rectangular Geometry correction default Elliptical k-space shutter default CLEAR yes body tuned FOV FH (mm) 270 AP (mm) 253.125 RL (mm) 221 Voxel size FH (mm) 1.11 AP (mm) 1.11 RL (mm) 1.3 Recon voxel size (mm) 1.054688 Fold-over suppression Slice oversampling default Reconstruction matrix 256 SENSE yes P reduction (AP) 1 P os factor 1 S reduction (RL) 1.8 k-t BLAST Overcontiguous slices slices 170 slice orientation sagittal fat shift direction F Chunks 1 PlanAlign Interactive positioning -7.38014 RL (L=+mm) 1.671578 FH (H=+mm) 15.46823 Ang. AP (deg) -1.783733 RL (deg) -0.07435598 FH (deg) -2.387414 Scan mode 3D Contrast enhancement T1 Fast Imaging mode TFE 3D n-selective shot mode single-shot TFE startup echoes default shot interval user defined (ms) 2500 profile order linear turbo direction Y partial echo shifted echo TE shortest Flip angle (deg) 9 TR shortest Halfscan (pixels) 1.8 Shim auto Fat suppression Water suppression TFE prepulse invert slice selection delay user defined (ms) 900 PSIR MTC T2prep Research prepulse Diffusion mode PNS mode low Gradient mode maximum SofTone mode

Page 5 of 5 Hospital (1) ADNI GO - ADNI 2 Phantom5 (4) 13:38.4 QC Phantom fmri 07:03.0 Total scan duration 07:03.0 Act. TR/TE (ms) 3000 / 30 Dyn. scan time 00:03.0 ACQ matrix M x P 64 x 59 ACQ voxel MPS (mm) 3.31 / 3.37 / 3.31 REC voxel MPS (mm) 3.31 / 3.31 / 3.31 Scan percentage (%) 98.33334 Packages 1 Min. slice gap (mm) 0 EPI factor 59 Act. WFS (pix) / 18.051 / 24.1 BW in EPI freq. dir. (Hz) 1886.2 Min. WFS (pix) / Max. 10.222 / 42.5 Min. TR/TE (ms) 2943 / 13 SAR / head < 29 % / 0.9 Whole body / level < 0.1 / rmal B1 rms [ut] 1.248067 PNS / level 61 % / rmal Sound Pressure Level 17.81354 Cardiac synchronization Navigator respiratory Flow Temporal slice spacing minimal fmri echo stabilisation Angio / Contrast enh. Quantitative flow Dynamic study individual dyn scans 140 recon multiplier 1 dyn scan times shortest dummy scans 0 immediate subtraction fast next scan synch. ext. device dyn stabilization prospect. motion yes corr. Keyhole Arterial Spin labeling Preparation phases full Manual Offset Freq. B0 field map/dixon B1 field map MIP/MPR Images M,,, Calculated images,,, EPI 2D phase correction reuse memory Save raw data Hardcopy protocol Ringing filtering default Geometry correction 2D Homogeneity correction ne CLEAR FOV RL (mm) 212 AP (mm) 198.75 FH (mm) 159 Voxel size RL (mm) 3.3125 AP (mm) 3.3125 Slice thickness (mm) 3.3125 Recon voxel size (mm) 3.3125 Fold-over suppression Reconstruction matrix 64 SENSE k-t BLAST type parallel slices 48 slice gap user defined gap (mm) 0 slice orientation transverse fat shift direction P Minimum number of 1 packages Slice scan order ascend PlanAlign Interactive positioning -6.54402 RL (L=+mm) 1.671578 FH (H=+mm) 21.73913 Ang. AP (deg) -1.783733 RL (deg) -0.07435598 FH (deg) -2.387414 Scan mode MS Contrast enhancement Fast Imaging mode EPI shot mode single-shot partial echo shifted echo TE user defined (ms) 30 Flip angle (deg) 80 TR user defined (ms) 3000 Halfscan (pixels) 18.049 Shim auto Fat suppression SPIR strength strong frequency offset default Water suppression MTC Research prepulse Diffusion mode PNS mode moderate Gradient mode maximum SofTone mode