Innovative hardware...

Similar documents
ProfiMessage. NEW Modular. Secure. Adaptable.

Product catalogue 2012 / Measuring. Testing. Automation.

The new Expert Logger 400: Industry 4.0 ready!

A NEW DATA LOGGER Stand alone. Secure. Fast.

Eurotherm advanced controllers providing solutions for simple to demanding applications...

PMA Rail Line. Product Brochure.

PRECISE STAND ALONE ADVANCED MEASUREMENT TECHNOLOGY. Innovative data logger. Modern. Powerful. Maintenance free.

Luminaire testing device

Z-GPRS2-SEAL THE SIMPLEST REMOTE MANAGEMENT SYSTEM FOR UNIVERSAL APPLICATIONS GSM/GPRS DATALOGGER WITH BUILT-IN I/O S AND TELECONTROL FUNCTIONS

Dew point. Dew point set DS 400. Special features: Dew point set DS 400. Technical data DS 400. Technical data FA 410

IRIS POWER TURBO. Machine Condition Monitoring System for Turbo Generators

X-Log Expert Data Logger

with Backlight Graphic LCD Screen

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

NF760 Batch Controller

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

SHCM SMALL HYDRO CONDITION MONITORING. Web HMI (real time data, trends, spectrums, alarms )

IRIS POWER HYDRO. Machine Condition Monitoring System for Hydro Generators

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Keeping the Lights On: Machine Monitoring Basics

INSTRUCTION MANUAL V1. 2x A

4-20 ma Transmitter vs. Machine Saver s VTBNet

FEATURES DESCRIPTION FEATURES

Efficient. Innovative. Sustainable.

DATA LOGGER MODELS DL-1080/1081

NOVUS AUTOMATION 1/92

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

DATA LOGGER MODELS DL-1080/1081

Max. I/O units. consumption

enod4 Weighing controller for automated systems

Condition monitoring systems. Vibration monitoring systems

AUTARKIC PROCESS MANAGEMENT

1500ct Pump Controller

General information. Display. Supply voltage

1500ct Pump Controller

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

GenIP : Intelligent gateway dedicated to most critical industrial applications

S-Line HIGH BRIGHTNESS AND ACCURACY DIGITAL LED INDICATORS MODULAR INDICATORS / TOTALIZERS WITH UNIVERSAL ANALOG INPUT

PROSMART Parts and Services Catalog

RS-485 I/O Modules: ADAM-4000

General information. Display. Supply voltage

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Multifunction controller GHM-ONE MSR9696H. Multifunction controller. Features. ... professional Instruments M ADE IN GERMANY

CHP GAS MONITOR GDR 1404

INTAB FLEXIBLE SYSTEM MANUAL. INTAB INTERFACE-TEKNIK AB GJUTAREVÄGEN 1, STENKULLEN 0/103

expertise beyond controls Vanguard Series 5

INSTRUCTION MANUAL. V1.6x F. CE Mark

Temperature, Process &

IP67 IP20. Controllers Open Flexible Compact SPEEDWAY. Programmable. Fieldbus Couplers. Programmable. Fieldbus Controllers

VIBSCANNER Data collection & machine diagnostics

CHP GAS MONITOR GDR 1404

Intelligent vibration monitoring.

WHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System

SKF Multilog On-line System IMx-8. 24/7 condition monitoring to improve machine reliability

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

deltadue series DIN rail mounting modules for control and data acquisition

Argus. Industrial Data Acquisition and Analysis

INSTRUMENTATION. Hydropower and water control applications

Web-enabled DAQ System

Data sheet VIPA CPU 115DP (115-6BL22)

Si-TEC Xtend GSM DATA SHEET. Digital control range for grid parallel/bus tie. Key features. Description

Making the decision to switch from PLC to PC-based Control has gotten even easier with the introduction of MachineLogic Control Software.

What is SCADA? What is Telemetry? What is Data Acquisition? Differences between SCADA and DCS? Components of SCADA. Field Instrumentation

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

enod4 weighing controllers For automated processes

Comprehensive Modular Genset Controller

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

InteliLite MRS17 Click Here to Learn More

NF770 Temperature Compensation Liquid Flow Computer

Sensaphone SCADA 3000

VIBSCANNER Data collection & machine diagnostics

JUMO mtron T Your System. The scalable measuring, control and automation system

A Next Generation OCS. XL Series OCS

General information. Display. Supply voltage. Input current

IT and Instrumentation for industry. Modular RTU Controller: IoPAC 8000 Series. Cellular RTU Controller: iologik W5300 Series

Data sheet CPU 013C (013-CCF0R00)

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

An all-in-one module. Archiving Up to 50,000 data items time-and-date stamped and saved to flash memory

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

Real-Time Monitoring Unit

General information. Display. Supply voltage

Master Time Center. Control Center for Multifunctional Time Distribution Systems and Mains Frequency Supervision

Acquiring Data from Sensors and Instruments Using MATLAB

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)

Compact Speed Monitoring and Overspeed Protection System

Meter Bus. Intelligent Communication

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Increase transparency and process quality Total Energy Monitoring across all levels of production Let s connect. Measuring and monitoring systems

DS 500 Intelligent chart recorder for compressed air and gases

General information. Display. Supply voltage. Input current. Encoder supply. Output current

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Ultra-Accurate Temperature Measurement Instruments

Local LCD HMI - View and force I/O, and make simple configuration changes without a computer!

Data sheet CC 03, Commander Compact (603-1CC21)

Innovations Octavis fluid sensors and diagnostic systems

AUTOMATIC AND AUTONOMOUS REMOTE WATER LEVEL AND WATER QUALITY MONITORING STATION

Transcription:

Innovative hardware... TopMessage and TopLab devices The perfect solution Process engineering Test engineering Research and development

the trendsetter... TopMessage for industry Our technology your benefits Uses existing company networks (TCP/IP data transfer) and doesn't require extra cabling Can operate independently without PC support guaranteeing data security and real time capability Existing PCs can be utilized no need for additional PC investment Integrated measuring transducers Integrated potential isolation no extra isolation amplifiers required Compact devices requiring little space Stand alone and intelligent using virtual channels such as calculation channels, limit values, counters, averages etc. Process signals attached using detachable clamps or laboratory plugs Optional Profibus DP slave interface Versatile use of Message devices in trials & test stand automation Suitable for both large and small numbers of channels... for measurement data acquisition via LAN The software you need TopLab for the laboratory Software for analysis, visualization, and monitoring can be installed on any PC within the network. This means you get the information where you need it. Web server integrated

... exceptional and innovative products A diverse range of uses proof of our products Visualization Analysis Monitoring Well known clients trust and build on the solutions we can provide for a range of different applications, e.g. in process engineering, test engineering, research and development as well as the complete monitoring and acquisition of operational data of tanks, plant and machinery etc. Using your existing PC you can analyze measurement data and operate and monitor your processes irrespective of where the Message devices are located. Message devices can operate as stand alone and are not dependent on PCs and networks. The 1 GB data storage ensures no loss of data even in the event of a power failure. Data can be transferred off line via file transfer; online functioning used for operation, monitoring and analysis.... Plant section 1,... Highlights. LAN, Ethernet, TCP/IP... plant section 2,... Message devices are compact and practical. They can be installed onto networks in the same way as PCs. Just connect the signals, configure the software and you're up and running. DELPHIN Message devices provide a unique link between analog and digital technology. Potential isolation means no need for isolating amplifiers giving cost and space benefits. No more disruptions due to earth loops. Unbeatable flexibility. Each analog input can be connected with RTD, thermocouple, volt or 20 ma signals providing savings on expensive measurement transducers. Increased reliability is also provided. Ethernet, TCP/IP, LAN 24-bit resolution provides a high level of measurement accuracy.

TopMessage devices Modular, practical, scalable Flexible use for both large and small numbers of channels The benefits of a modular system become really apparent when planning applications. Delphin's engineers are available with advice and support and will provide you with a personal quote. Equally effective for both large and small numbers of channels. A TopMessage master device can have up to 30 analog channels. Modules can be combined as required. Any number of slave devices can be connected to the master. Slaves are of the same casing design and each can be equipped with 2 modules. Data transfer between master and slave takes place via a CAN bus. CAN-Bus......... Pressure. Temperature. Rotations. Vibrations. Flow. Digital I/O. Meter reading Module Analog- Analog- Frequency Status- switch- Sum inputs outputs status-inputs inputs outputs Samplingrate ADGT ADIT ADVT ADFT 8 channels Volt/mV,20mA,RDT, 10 channels Volt/mV,20mA,RDT, 15 channels Volt/mV,20mA, 8 channels Volt/mV,20mA 20mA 0...10 V 60 Hz 600 Hz 600 Hz 10 khz AMDT 8 channels Volt/mV,20mA 0...10 V 10... 160 khz AAST IOIT Volt/mV,20mA,RDT, 20mA 2 600 Hz OTPT 24 channel DIOT 1s 16 channel Precise measurement data Measurement data is saved as scaled and linearised (e.g. bar, litre/sec, C,...). Very precise measurements, 24-bit resolution, auto-calibration. AMDT module For transient measurements and vibration analysis. All the functions for frequency spectrum acquisition and fast analog signals, with a sampling rate of up to 20 khz per channel, in one small package.

Virtual channels for your benefit DELPHIN-products enable you to efficiently set up your own applications. The following features provided by Message devices can be configured from your own PC using the Busmanager software. High measuring rates through parallel processing The design of the devices provides fast measurement of large numbers of channels via parallel processing. This makes possible the analysis of dynamic events. Connecting measuring devices Serial ports for connecting weighing machines, large displays etc. via RS232, RS422, RS485, protocol generator for ASCII protocols, modbus. Connecting to Profibus DP TopMessage can also be operated as a Profibus DP slave. Process data from PLC systems can then be stored in the TopMessage device or be subjected to calculations with results being returned to the process. Remote data transfer Direct connection to telephones, radio or GSM modem enabling remote monitoring. Just configure the system to transfer data either to a workstation on the local network or to a remote computer via a modem. Modems can be connected via a serial port. Message devices automatically generate the telephone connection and can send error messages as SMS's. Networks and protocols LAN, WAN, TCP/IP and UDP; standard services such as SMTP, Telnet, HTTP, NTP, DHCP, FTP, DNS Limit values Limit values can be set for any channel for issuing alarms and trigger outputs. Integrated wire breakage monitoring. Calculation channels Allow the mathematical assignment of channels. In this way calculations can be made for differentiation measurements, quotients, efficiency factors, capacities etc.. Calculation channels can be saved and evaluated just like measurement channels. Examples: calculating temperature differences, turning moments, capacities...etc.. Linearisation channels Additional to the built in fixed sensor linearisation, user-defined sensor characteristic curves (up to 8 000 value pairs) are also possible. Email and SMS transmission with Message devices Error messages can be issued independently by TopMessage devices via email and/or SMS. Averaging channels, statistical functions As well as the actual measurement value of an analog input, its average can also be calculated and then used as a further channel. Time referenced averages, moving averages, statistical functions. PID controller The AAST module, with 4 analog inputs/outputs enables the parallel operation of 4 controllers. Automatic and real time setting of standard parameters. Integrator and differentiator channels The value of an analog or status input can be integrated and differentiated over a time period and used as a further channel. This also includes flank and operation hour counters Setpoint channels Permits the generation of setpoints for internal and external use. This allows the management of external devices such as controllers and the observation of events from a PC. Timer channels For the generation of flanks and impulses for digital outputs. A simple tool to manage reset timer and alarming functions Pulse width modulator Timing relay function Timed alarm function Impulse provider (random or real time synchronized)

Vibration technology... exceptional and innovative Made possible by leading edge technology TopMessage's compact AMDT module provides vibration analysis and monitoring at an unbeatable price. The modular TopMessage system enables the simultaneous monitoring of machine vibrations and process values such as temperatures and pressures All the functions in a compact module for the acquisition of fast analog signals and frequency spectrums: Applications Monitoring and diagnosing: shaft vibrations bearing vibrations vibrations in plant and machinery 8 analog inputs parallel sampling rate of 20 khz per channel 2 analog outputs 4 digital input/outputs Main features precise monitoring system with early warning of impending damage easy analysis and diagnosis of actual condition of plant and machinery from any PC comprehensive quality assurance through longterm recording of data and automated data transfer incident inquiry capability based on facts and not speculation monitoring of limit values shaft vibration according to VDI 2059 standard vibration level measurement according to DIN ISO 10816 standard Vibration Inputs envelope curve frequency analysis for bearings

MHouse and software... intuitive and persuasive One system many benefits Practical and value for money Modular and flexible are the key words for the tried and tested MHouse software. You choose the module to meet your specific requirements and install the software on your existing PCs. You can then manage your measurement data using the TCP/IPP protocol and your existing company network. (Further information available by requesting our MHouse software brochure). The following modules are available: The new software significantly extends the range of applications available. Test, processing and trial procedures can now be generated much more easily than previously possible. ProfiSignal provides a complete solution. Variability at a reasonable price Quick to install, easy to use and cost factors make Delphin products an easy choice. The system provides the tools to meet your specific requirements, so that you get a quick return on your investment (for further information ask for the ProfiSignal brochure). Basis package acquiring, observing, analyzing, archiving, monitoring and exporting of measurement data online and offline observation management of measurement data acquisition remote data acquisition, monitoring and diagnosis Process visualization operating, observing, monitoring fast generation of process diagrams VibroLab observing, analyzing, archiving, exporting of vibration measurement data immediate evaluation: time signal, FFT/ spectrum, orbit, cascade and polar graphs and diagrams LabView, DasyLab, OCX drivers TopMessage with National Instrument's LabView software, the OCX driver for self programming OPC-Server interface between external software and Message devices The modules: Basic Measurement data acquisition Measurement data acquisition Measurement data evaluation Quality assurance Monitoring Measurement data & processing Visualization, operation & observation Setting parameters Testing, processing and trial procedures Recording and reporting Condition monitoring Predicative maintenance Crash avoidance Weak point analysis Cause investigation