CS XL XM. EcoSystem Bus Supply

Similar documents
Energi Savr NodeTM QSN-2ECO-PS120 EcoSystem with Shades ESN a

Energi Savr Node with DALI for Quantum

EcoSystem One-Line. EcoSystem C5-XPJ-16A Switching Power Module

QuantumR Light Management Hub

QuantumR Light Management Hub (QP2)

PowPak Single Zone Control Module with EcoSystem

QSNE-2DAL-D Energi Savr Node QSTM 20 V. DALI Loop 2. seetouch QS Wallstation Energi Savr Node QS. QS Control Link

LQSE-4S8-120-D. 120 V~ 50 / 60 Hz 16 A. lutron.com LQSE-4S8-120-D. Dimming Power Module. Option. Input. Opt Def H M

Energi Savr Node for DALI QSNE-2DAL-D DALI Fixture Controller V. Photo

Hi-lume 1% EcoSystem Constant-Voltage 24 V- LED Driver with Soft-on, Fade-to-Black Dimming Technology

Hi-lume Premier 0.1% EcoSystem LED Driver

Hi-lume A-Series Driver Overview EcoSystem or 3-wire control

EcoSystem to 0 10 V- Interface

RadioRA 2 Visor Controls

Energi Savr NodeTM for 0 10 V Energi Savr NodeTM with Softswitch

UL Listed Hi-lume A-Series Constant Voltage Driver Overview

HomeWorks QS Visor Controls

RadioRA 2 Visor Controls

Sivoia QS Wireless Smart Panel

5AMP Power Pack. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALPP 5ACC or ALPP 5A Part #: or

EcoSystem Digital Ballasts

24V Power Pack. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALPP 24VCC Part #:

HomeWorks QS Processor

10-Output Configurable Smart Panel

Quantum Light Management Hub (QP3) for Quantum Select

Energi Savr NodeTM Programming Interface

GRX-CI-RS232 Control Interface

20AMP Plug Load Controller

Max. Input Power (W) Input Current. Inrush Current

HomeWorks QS Processor

LED Recessed Downlights 12 W LED Round: Fixed or Tilt Downlights 12 W LED Square: Fixed or Tilt Downlights

HomeWorks Remote Power Feed-Through Panels

GRX-CI-NWK-E Control Interface

IVR15-SPI 1.5 Solid State Illuminated Rail 2 Post Integral Power Supply

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

Specialized Lighting Solutions, Inc. SLS DALI CONTROLLERC

ICP-SDI Installation Instructions. SDI Splitter

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

specifications: Metrolight SmartHID Electronic Ballast 100/150/ Watt - HPS 175/200/250/320/400/450 Watt - MH

GR 2400 PLANNING GUIDE. Important Note:

Distributed Power Series

Switched Relay Controller - Relay Panel with Breakers

LCP128 Dimming and Switching System

Installation and User Guide

GRX-3000 Control Units

ETC Installation Guide

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Product and functional description

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

HomeWorks Wired Signature Series Keypads

SAVE THESE INSTRUCTIONS

E1 Plus Electronic Overload Relay

Wireless Fixture Adapter (WFA100-SN) Installation Instructions

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

SCD96 DMX Output Interface. Installation guide

QSE-CI-DMX Control Interface

GRAFIK 5000P / 6000P / 7000P Processor Panel

HIGH BAY PASSIVE INFRARED OCCUPANCY SENSOR

Digital Keypad Introduction

Light Management Hub. Quantum 230 V CE Light Management Hub. Centralized Control Equipment

OMX-CI-RS232 Control Interface

Field selectable application type and room module series, via dip-switches on controller

HomeWorksR QS Dynamic Keypads

QS Sensor Module. product specifications a Model Numbers

Lighting Control Panel

TC-9102 Series Surface Mount Temperature Controllers

High Wattage, High Bay LED Fixture

Multi-Point Gas Detection and Control System

System Overview. EcoSystemTM Bus. IR Receiver. Occupant Sensor. IR Remote 1 Supplied by others

TT-NRM. Network Relay Module Installation Instructions WARNING:

High Wattage, High Bay LED Fixture

LCP128 Dimming & Switching System

HomeWorks Wired seetouch Keypads (Domestic Models)

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

LUT-DMX DMX512 Control Interface

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Features. Applications and Benefits TRC ELECTRONICS, INC

TPE 1464 Series Pressure Transducer

Wallbox Power Module. 4/8 Series Remote Dimming Controls Grafik Eye /WPM Link N/A INTRODUCTION SPECIFICATION & DESIGN FRONT ROOM BACK ROOM APPENDIX

CDD Carbon Dioxide Transmitter

seetouchtm B&O Keypads 15 V 65 ma NEC Class 2; IEC PELV

QUINT-PS/ 1AC/24DC/ 5

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

Custom Controller Installation Instructions

QSE-CI-DMX Control Interface

Multi-Point Gas Detection and Control System

GRAFIK Eye 3000 Series Control Unit

Wireless Adapter (WA100-PM) i. Installation Instructions

product specifications d

CTR21, CTR22, CTR23, and CTR24 Wall Modules

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

Dimmers with Neutral Wire for Halogen, Incandescent, ELV, or Interfaces

General Programming Tips

ASI Systems ML5740A Series

ASI Systems ML5720A Series

PowerFlex 400 AC Drive Guide Specification

Transcription:

EcoSystem An EcoSystem lighting network containing more than one ballast, module, or driver requires an EcoSystem. This supply powers one or two independent EcoSystem buses with up to 64 ballasts or ballast modules per bus. Features Provides power for either one or two EcoSystem buses, depending on model. Reprograms settings of replacement ballasts automatically. Maintains redundant memory of ballast and module programming for building sustainability. Accepts up to two normally open or normally closed dry contact closures per bus to allow integration with occupancy sensors, demand response inputs, or AV equipment. Accepts one normally closed emergency input per supply to allow integration with building management and/or security systems. EcoSystem Bus may be wired EC Class 1, IEC PELV or EC Class 2. Bus wires are polarity insensitive and topology free Voltage input: 100 277 V~ 50/60 Hz. on-volatile (EEPROM) memory stores specific system information for 10 years from power-down to power restoration. 100% performance tested at factory. Allows programming via the EcoSystem Programmer. Programming can be locked out via DIP switch. 12345678 / / Em C Front View (CS-1L shown) Top View (CS-1L shown) Side View / / Em C Bottom View (CS-1L shown) 369973c 1 04.07.17 Building a Model umber CS XL XM Power Provided Code umber of Buses Powered 1 1 EcoSystem Bus 2 2 Independent EcoSystem Buses Model umber Links Enclosure CS-1L-CM 1 o CS-1L-WM 1 Yes CS-2L-CM 2 o CS-2L-WM 2 Yes Enclosure Code Enclosure C ot shipped with an enclosure W Unit premounted in UL-listed 8 8 4 in (203 203 102 mm) enclosure SPECIFICATI SUBMITTAL

Specifications Regulatory Approvals UL, CUL, and OM listed Meets ASI C62.41 Category A surge protection standards up to and including 4 kv. Lutron Quality Systems registered to ISO 9001.2000 For commercial use, Class A only Power Input Voltage: 100 277 V~ 50/60 Hz Output Voltage: 18 V- 250 ma maximum EC Class 1, IEC PELV or EC Class 2 per bus Device draws less than 0.18 A. Wiring Power Wiring: 12 18 AWG (1.0 4.0 mm 2 ) EcoSystem Bus, Class 2 contact closures: 12 22 AWG (0.5 2.5 mm 2 ) 369973c 2 04.07.17 Mounting Considerations Requires UL508 listed enclosure per EC (customer supplied if CM model). Enclosure provided if WM model is ordered. Mounts to standard DI rail (included). Environment Ambient Temperature Operating Range: 32 104 F (0 40 C) Relative humidity: less than 90% non-condensing EcoSystem Lighting etwork Example EcoSystem Bus may be wired in accordance with EC Class 1, IEC PELV or EC Class 2 practices. Sensors and EcoSystem contact closures must be wired IEC PELV or EC Class 2. EcoSystem Bus To additional ballasts and modules (up to 64 total) EcoSystem Ballast 1 2 3 4 5 6 7 8 EcoSystem Module Eco-10 or Hi-lume Ballast* EcoSystem Ballast EcoSystem Ballast IR Receiver EcoSystem (CS-1L shown) Occupancy sensor Daylight Sensor Lighting Remote Keypad SPECIFICATI SUBMITTAL

Dimensions Measurements are shown as: in (mm) 369973c 3 04.07.17 1.77 (45) Top View 3.62 (92) 3.62 (92) Left-Side View Front View 3.62 (92) Right-Side View 12345678 3.56 (85) / / Em C Bottom View / / Em C 3.62 (92) SPECIFICATI SUBMITTAL

Mounting 369973c 4 04.07.17 CM Models Select a UL508 listed electrical enclosure with minimum dimensions (w h d): 8 8 4 in (203 203 102 mm). Mount enclosure as per applicable instructions. Mount DI rail horizontally in the center of the enclosure. Clip the EcoSystem onto DI rail (see diagram below). WM Models Mount enclosure using the four mounting holes within the enclosure (shown below). CS-1/2L- (CS-1L shown) Measurements are shown as: in (mm) 4 (102) 8 (203) 6 (152) 1 (25), typically 1 2345678 6 (152) 8 (203) / / Em C 4 (102) Mounting Holes Knockouts for wiring: f 0.75 (19) SPECIFICATI SUBMITTAL

Wiring: Overview 369973c 5 04.07.17 Mains Wiring and Low-Voltage Separation The EcoSystem is designed to separate mains wiring (EC Class 1) and low-voltage IEC PELV or EC Class 2 circuits Follow appropriate local and national codes to avoid violating required separation guidelines CS-2L- shown Ground Hot/Live eutral 1 2345678 Line Voltage Wiring Area Low Voltage Wiring Area B A Em C To first bus ballasts and modules To second bus ballasts and modules (2L version only) SPECIFICATI SUBMITTAL

Wiring: Overview (continued) 369973c 6 04.07.17 Top View (CS-2L- shown) Mains Wiring Terminal (black) eutral Hot/Live Front View (CS-2L- shown) Option (OPT) Switches LED Indicator Lights: Bus 2 (green) Error/Emergency (CS-2L only) Bus 2 (green) Status CS-2L only) 12345678 Bus 1 (blue) Error/Emergency Bus 1 (blue) Status Mains Status Mains Power B A Em C EcoSystem Bus 1 (blue) Terminal: E2 E1 Bottom View (CS-2L- shown) B A Em C EcoSystem Bus 2 (green) Terminal (CS-2L only): E1 E2 Contact Closure Bus 1 (red) Terminal: EcoSystem Bus 1 CCI Com EcoSystem Bus 1 CCI 1 EcoSystem Bus 1 CCI 2 Emergency Contact Closure Contact Closure Bus 2 (red) Terminal (CS-2L only): EcoSystem Bus 2 CCI 2 EcoSystem Bus 2 CCI 1 EcoSystem Bus 2 CCI Com SPECIFICATI SUBMITTAL

Wiring: Line Voltage (Mains) Wiring from Distribution to Select source of feed for the EcoSystem (100 277 V~). Turn off breaker at distribution panel. Run hot, neutral, and ground wires from distribution panel to the EcoSystem. The EcoSystem is grounded via ground clips on bottom of module through the DI rail. Ensure that the enclosure and DI rail are properly grounded per national and local electrical codes. ote: Ballasts, modules, and drivers are in emergency (bypass) mode (lights at full output) until power is applied to the EcoSystem. Emergency Feeds and the Use normal (non-essential) power only. When normal power drops out, the EcoSystem Bus Supply cannot power the EcoSystem Bus. When this occurs, ballasts, modules, and drivers go to emergency (bypass) mode (full light output by default). 369973c 7 04.07.17 See Application ote #140 for additional information related to emergency feed wiring. CS-1L- shown Ground Hot/Live eutral 1 2345678 SPECIFICATI SUBMITTAL

Wiring: EcoSystem Bus The EcoSystem Bus connects all ballasts together and requires a. 1L models power one EcoSystem Bus; 2L models power two independent EcoSystem buses. Each EcoSystem Bus can support a maximum of 64 ballasts, modules, or drivers. Class 1 and Class 2 Wiring The EcoSystem Bus may be EC Class 1, IEC PELV or EC Class 2 EC Class 1: Low-voltage bus wiring may be run with mains voltage to any fixture the bus is controlling IEC PELV or EC Class 2: Low-voltage bus wiring must be separated from all mains and Class 1 wiring Using two different colors for E1 and E2 wire helps prevent miswires when multiple buses are present in the same conduit Consult all national and local electrical codes for separation requirements 369973c 8 04.07.17 Wiring Details E1 and E2 wires are not polarity sensitive Bus length is limited by the wire gauge used for E1 and E2 as follows: Wire Gauge Bus Length (max) 12 AWG (4.0 mm 2 ) 2200 ft (671 m) 14 AWG (2.5 mm 2 ) 1400 ft (427 m) 16 AWG (1.5 mm 2 ) 900 ft (275 m) 18 AWG (1.0 mm 2 ) 570 ft (175 m) CS-1L- shown 1 2345678 / / Em C E1 E2 SPECIFICATI SUBMITTAL

Wiring: Contact Closures 369973c 9 04.07.17 Contact closure inputs are IEC PELV or EC Class 2 circuits and cannot be run with mains wiring. Unless otherwise specified, the voltages should not exceed 12 35 V-. These circuits comply with the requirements of FPA 70, ational Electric Code (EC ). Follow all applicable national and/or local wiring regulations. Contact Closure Bus Terminals C Em A B Terminal Unit Label Function C COM Common Em CCI-EMERG Emergency A CCI-1 Contact Closure 1 B CCI-2 Contact Closure 2 Emergency For integration with a security or fire alarm system, the emergency input may be used. The alarm system must have a normally closed relay for proper operation. Wiring is shown to the right. Common is Terminal C and Emergency is Terminal Em on the EcoSystem. On a 2-link supply, there is only one Emergency Input, which affects both links. Emergency mode must be activated using OPT switch 5. By default emergency inputs are ignored (DIP switch 5 set to ). When switch 5 is OFF an open condition between terminals 5 and 6 results in emergency mode activation. C Emergency Input C Security Contactor Em Bottom View (CS-2L- shown) B A Em C Contact Closure Bus 1 (red) Terminal: EcoSystem Bus 1 CCI Com EcoSystem Bus 1 CCI 1 EcoSystem Bus 1 CCI 2 Contact Closure Bus 2 (red) Terminal (CS-2L only): EcoSystem Bus 2 CCI 2 EcoSystem Bus 2 CCI 1 EcoSystem Bus 2 CCI Com Emergency Contact Closure SPECIFICATI SUBMITTAL

Operation: Contact Closures Contact Closure Inputs Contact Closure Inputs (CCI) on the may be used to integrate a BMS system or occupancy sensors with an EcoSystem Lighting etwork. On a 2-link supply, there is one pair of CCIs for each EcoSystem Bus. There are three modes of CCI operation: Occupancy mode Demand Response mode Scene Selection mode These modes can be selected and configured using the EcoSystem Programmer. Occupancy Mode CCIs command assigned groups on the corresponding bus to an Occupied light level or an Unoccupied light level when the contact closures are opened or closed. When the CCI is in the occupied state, the system will command ballasts assigned to that CCI to go to their occupied level. When the CCI is in the unoccupied mode, the system will command ballasts assigned to that CCI to go to their unoccupied level. ote that if ballasts are grouped to both a CCI in Occupancy mode and an occupancy sensor, the occupancy sensor will not sweep the group to its unoccupied level unless the CCI is also unoccupied. Demand Response Mode In demand response mode, each CCI, when closed, applies a configurable demand response level to the group. When the CCI is opened, the demand response level is cleared. Ballasts will scale their current light level by the demand response level (e.g., if the demand response level is set to 25%, all ballasts will dim to a light level that is 75% of their previous level and will not dim above 75% until the CCI is opened). CCI-2 takes priority over CCI-1, so if the same group of ballasts are assigned to both CCIs, when both CCIs are closed, the ballasts will scale to the level set for CCI-2. 369973c 10 04.07.17 Scene Select Mode When the CCIs are closed and maintained according to the table below, the corresponding scene is selected on all ballasts on the link. Momentary contact inputs may be used if Scene 1 is set to Unaffected. CCI 1 CCI 2 Scene Open Open 1 Closed Open 2 Open Closed 3 Closed Closed 4 See Application ote #236 for further information on EcoSystem contact closure input modes. SPECIFICATI SUBMITTAL

Operation: Status LEDs 369973c 11 04.07.17 LEDs on the EcoSystem indicate network status. The specific LEDs, color and flashing method is detailed below. LED / Off ormal Operation Intermittent flash or Off Steady flash Problem Indicator Probable Cause On Emergency contact closure is active Steady flash On Off On Miswire detected on corresponding bus Unit fault o Mains power or unit fault Unit fault On Off o Mains power 123 4 5678 B A Em C SPECIFICATI SUBMITTAL

Operation: OPT Switches 369973c 12 04.07.17 OPT switches are used to configure the. The table below describes the options. To place an OPT switch in the OFF position, slide the switch to the left. Default switch position is. OPT Description Switch Position Function 1 First bus (green) CCI-1 input type ormally open 1 OFF ormally closed 2 2 First bus (green) CCI-2 input type ormally open 1 OFF ormally closed 2 3 3 Second bus (blue) CCI-1 input type ormally open 1 OFF ormally closed 2 OPT Switch OFF 4 3 Second bus (blue) CCI-2 input type ormally open 1 OFF ormally closed 2 OPT Switch 123 4 5678 B A Em C 5 Emergency disable 6 Programming 7, 8 ormal/override Emergency contact closure input disabled Emergency OFF contact closure input enabled Programming enabled via EcoSystem programmer Programming OFF disabled via EcoSystem programmer 7, 8 ormal operation 7, 8 OFF Override: High end 7 OFF, 8 Override: Low end 7 OFF, 8 OFF Override: Off SPECIFICATI SUBMITTAL

Operation: Combining Occupancy Sensors with CCIs 369973c 13 04.07.17 Occupancy sensors with relay outputs can be wired to the contact closure inputs on the bus supply. Follow the diagram below. Occupancy sensor relay outputs can be normally open or normally closed. Set the OPT switch for the CCI to match the type of sensor output being used. Occupancy sensor (rear view) +24 V- Common Power Pack PP-120H (for 120 V~) or PP-277H (for 277 V~) To terminals: C: Common A: CCI 1 or B: CCI 2 120~ or 277 V~ Relay output Bus supply Lutron, Lutron, Eco-10, Hi-lume, and EcoSystem are trademarks of Lutron Electronics Co., Inc. registered in the U.S. and other countries. SPECIFICATI SUBMITTAL