DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

Similar documents
DINALOG A 144 x 36 A1400 Light-Strip Indicator

Vision OPLC. Technical Specifications. V T34 Technical Specifications

100% electricity. Power factor correction components

EX-RC1 Remote I/O Adapter

Using your PC to access a remote M90 via GSM

Component identification

3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

UniStream HMI Panel. CPU-for-Panel

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

UniStream CPU-for-Panel

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Vision OPLC. V TR6 Technical Specifications. Technical Specifications.

V E5B Snap-in I/O Module

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

V350-RA22 V350J-RA22.

Vision OPLC V TR20/V350-J-TR20

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Industrial Ethernet from Hirschmann. WELCOME TO ATEX ZONE 1: SIMPLY A GOOD CONNECTION

IO-DI16, IO-DI16-L I/O Expansion Modules

CARLO GAVAZZI Automation Components. Wireless Safety System

VENTILATION. Short catalogue VENTILATION COMMON FEATURES.

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection

V E62B Snap-in I/O Module

CARLO GAVAZZI. Automation Components. The quick-fit energy metering solutions

Unitronics Devices and RS485 Table Of Contents

LIMANDA Handheld Enclosures Product Drawings Last Updated 6/5/2008

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

CARLO GAVAZZI Automation Components. Switching Power Supplies from 5W up to 960W

EX-RC1 Remote I/O Adapter

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

100% electricity. Automatic transfer switch controllers ATL series

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply

Bulletin 1492 In-Panel I/O Wiring System Modules and Cables for Allen-Bradley Programmable Controllers Reduced Wiring Time, Accurate Connections

MID approval no. DE-08-MI004-PTB004 Date of release

Compact Universal Controllers

JUMO Quantum PID100/PID200/PID300

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

VariTrans P The Problem The variety of tasks results in a large number of different devices.

VariTrans P Standard-Signal Isolators

FiberINTER. FiberINTERF. FiberINTERFACES.

Accessories - cable tie bases

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

efive 100 Installation Guide

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Vision OPLC. General Description.

Safety Temperature Limiter TT-STL 50

Indicomp 4 Bargraph Indicator

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

Multifunction

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

Analog display for resistance current

Vision OPLC V TR20

aditec CONTROLS for FOODTECHNOLOGY

TB 45 Temperature limiter / monitor

Characteristics. High impact with draw wire (ICTA 3422) Use. Accessories for conduits (p. 754)

MINI MCR-SL-UI-REL(-SP)

AI531 Analog Input Module

Vision OPLC. General Description. Installation Guide V T34.

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

JUMO safetym TB/TW 08 Temperature limiter, monitor as per DIN EN

Medium Voltage Solutions For Water and Wastewater Treatment

Micro800 Programmable Controllers

Printing recorder with text printing and 24-character LED dot-matrix display. Brief description. Overview of functions. Features

MIC-2 MKII, Multi-instrument DATA SHEET

Precision Hand-held Thermometer

JUMO diraview 104/108/116/132

IO-DI8-RO4, IO-DI8-RO4-L I/O Expansion Modules 8 Inputs, 4 Outputs

Bulletin 1790D 1732 Type CompactBlock LDX Distributed I/O ArmorBlock I/O. Horizontal / Vertical Panel or DIN rail mounted

with Backlight Graphic LCD Screen

PanelView 800. Allen-Bradley Component Level Human Machine Interface Solutions

Bulletin 440R 440R 440R-S

MCX08M2 Programmable controller

MINI MCR-SL-PT100-UI(-SP)(-NC)

V E3XB Snap-in I/O Module

Paperless recorder Ecograph

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids

SX90 Process Controller

Contents RFID. 57RF Handheld Interfaces and Spacers... page RF Cables... page 11--7

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Standard-Signal Isolation Amplifiers. VariTrans A 21000

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

Test devices and Multifunction timer relay

Compact universal controllers

SNAP PAC Redundancy Option Kit

Electronic timer CT-AHD.22

Contact protection relay

Smart Portal SP5000SERIES

Electronic timer CT-ERD.12

Transcription:

Bar graph displays For process control, automation, and laboratory applications Current, voltage, resistance, frequency and temperature Up to 0.5% resolution

DINALOG A 96 x 24 Programmable quasi-analogue bar graph meters Single channel meters with a LED light bar and additional digital display. For DC and AC current and voltage, temperature and resistance measuring ranges. Models with two limits are available. The limits are displayed simultaneously with the measured value on the light bar. If a limit is exceeded, this is signalled via relay contacts on the rear side and by an LED on the scale. All measured values at a glance Precise values due to additional digital display High-contrast LED displays High legibility, wide viewing angle Measurement circuit galvanically isolated from the power supply Front dimensions: 96 x 24 mm Front protection to IP65 Small installation depth of less than 127 mm Quick installation due to slider mount for all control panel thicknesses Pre-wiring is possible due to plug in screw terminal blocks These measuring instruments are suitable for all applications in which several measured values must be monitored simultaneously. Due to high legibility, you have a good overview of important measured values at a glance, even in unfavourable light conditions. Each meter can be configured to suit the respective measurement application, by means of various measurement modules. With their high-contrast LED display, these meters are a good alternative to conventional analogue displays, or liquid crystal bar graph displays. The LED light bar with 35 segments shows you the measured value with a resolution of 3%, on a scale which is 45 mm in length. By means of the additional polarity indicator, you can also use the full display range for bipolar measurement. Simple programming with the three buttons enables you to adjust the display range on site. Our bar graph displays comply with the regulations defined by the European Directives 73/23/EEC and 89/336/EEC, as verified by compliance with the following standards: IEC/EN 61 010-1:2001, VDE 0411 Part 1 (safety regulations) (interference resistance) (emitted interference) Technical characteristics DINALOG A 96 x 24 Display Analogue Digital Digit height length colour LED Red or green 35 segments 3-character 7-segment display with polarity indicator Approximately 8 mm 96 x 24 mm, vertical or horizontal (horizontal format without digital display) 45 mm White or black 0... 2 V to 0... 300 V and ± 2V to ± 300 V 0... 4... 20 ma 0... 0.2 ma to 0... 200 ma and ± 0.2 ma to ± 200 ma AC voltage AC current Temperature Resistance Supply voltages 0... 0.2 V to 0... 300 V and 700 V 0... 2 ma to 0... 200 ma and 0... 1 A; 0... 5 A Via Pt100 or thermocouples, types: J, K, R or S 0... 200 Ω to 0... 20 kω 230 V/115 V AC/ 90... 260 V DC or 24 V AC/18... 36 V DC Outputs for limit monitors 2 relays Each with change-over contact 2 additional relays Each with NO contact Switching capacity 5 A/250 V AC, 5 A/30 V DC Switching time Max. 200 ms 2

DINALOG A 144 x 24 Programmable quasi-analogue bar graph meters Bar graph displays serve to display measurement signals visually. It is generally possible to connect sensors directly, or via measuring transducers. Depending on the visual resolution of the values to be displayed, bar graph displays are subdivided into trend indicators, overview indicators, and measuring instruments. Our bar graph displays comply with the regulations defined by the European Directives 73/23/EEC and 89/336/EEC, as verified by compliance with the following standards: IEC/EN 61 010-1:2001, VDE 0411, Part 1 (safety regulations) (interference resistance) (emitted interference) Display of measured values with a choice of red or green 101-segment light bar, plus a red or green 4-character digital display with a numerical range from 1999 to +9999 (12,000 counts). Highly suitable for all applications in which several measured values must be read out simultaneously. (With meters mounted side by side). All measured values at a glance Precise read-out of values due to additional digital display Programmable measurement rate: 3...16 per second High legibility and wide viewing angle 4-level brightness levels for the light bar and digital display Up to four programmable limit values Limit status display via additional LEDs on the scale Two or four relays available 4 20 ma measurement with 24 V DC supply for 2-wire measuring transducer Quick installation possible due to metal slider Electrical connection occurs via plug in screw terminals Front dimensions: 144 x 24 mm to DIN 43718 Installation depth: 152 mm Technical characteristics DINALOG A 144 x 24 Display Analogue Digital Digit height length colour LED Red or green 101 segments 4-character LED display with polarity indicator Approximately 7 mm 144 x 24 mm, vertical or horizontal (horizontal format without digital display) 91 mm White or black 0... 0.1 V to 0... 200 V and ± 0.1 V to ± 200 V 0... 4... 20 ma 0... 4... 20 ma with 24 V DC supply for measuring transducer 0... 2 ma to 0... 5 A and ± 2 ma to ± 5 ma AC voltage AC current Temperature Resistance Supply voltages 0... 0.2 V to 0... 200 V and 600 V 0... 2 ma to 0... 200 ma and 0... 1 A; 0... 5 A Via Pt 100 or thermocouples, type: J or K 0... 200 Ω to 0...10 kω 85... 265 V AC/ 95... 370 V DC or 15... 48 V AC/10... 72 V DC Outputs for limit monitors 2 relays Each with change-over contact 2 additional relays Each with NO contact Switching capacity 5 A /250 V AC, 5 A /30 V DC Switching time Max. 200 ms 3

DINALOG A 144 x 36 Programmable quasi-analogue bar graph meters Single display The measured value is displayed on a light bar, and simultaneously on the digital display. For models which have limit settings, you can read the defined limits clearly on a second light bar alongside the measured value. Therefore, you have a clear overview of the difference between the measured value and the limit values. Double display The measured values are displayed on two light bars side by side. You can select one measured value to be displayed simultaneously on the digital display. A LED at the beginning of the respective light bar scale, shows you which measured value is being displayed by the digital display. 71 segments With a scale length of 91 mm, the measured value is displayed with a precision which is better than class 1.5. Alarm messages: Additional LEDs on the scale indicate when limits are exceeded. The small installation depth of less than 127 mm enables installation into practically any control cabinet. Front dimensions: 144 x 36 mm to DIN 43718 Bar graph displays serve to display measurement signals visually. It is generally possible to connect sensors directly, or via measuring transducers. Depending on the visual resolution of the values to be displayed, bar graph displays are subdivided into trend indicators, overview indicators, and measuring instruments. Our bar graph displays comply with the regulations defined by the European Directives 73/23/EEC and 89/336/EEC, as verified by compliance with the following standards: IEC/EN 61 010-1:2001, VDE 0411, Part 1 (safety regulations) (interference resistance) (emitted interference) Technical characteristics DINALOG A 144 x 36 Display Analogue Digital Digit height length colour LED Red or green 71 Segments 3-character 7-segment display with polarity indicator Approximately 8 mm 144 x 36 mm, vertical or horizontal (horizontal format without digital display) 91 mm White or black 0... 2 V to 0... 300 V and ± 2V to ± 300 V 0... 4... 20 ma 0... 0.2 ma to 0... 200 ma and ± 0.2 ma to ± 200 ma AC voltage AC current Temperature Resistance Supply voltages 0... 0.2 V to 0... 300 V and 700 V 0... 2 ma to 0... 200 ma and 0... 1 A; 0... 5 A Via Pt100 or via thermocouples, types: J, K, R or S 0... 200 Ω to 0... 20 kω 230 V/115 V AC/ 90... 260 V DC or 24 V AC/18... 36 V DC Outputs for limit monitors 2 relays Each with change-over contact 2 additional relays Each with NO contact Switching capacity 5 A /250 V AC, 5 A /30 V DC Switching time Max. 200 ms 4

Serie LS200 no longer available Replacements: Serie LS300, alternatively DINALOG A 1400 LS 200 Quasi-analogue bar graph meters 144 x 48 mm All measured values at a glance Electronic panel-mounted measuring instrument with gas discharge display 201 distinguishable segments Single display without limit values, or with two limit values Double display without limit values, or with two limit values Two limit values can be set and displayed Front panel controls to set limit values Measuring range adjustment possible Display of limit values with pointers on the scale An exceeded limit is displayed by means of an LED on the scale Highly suitable for control rooms and process control systems which require high resolution and precise read-outs of measured values Installable in any location, vibration-resistant Front dimensions: 144 x 48 mm to DIN 43718 Installation depth: 163 mm Our bar graph displays comply with the regulations defined by the European Directives 73/23/EEC and 89/336/EEC, as verified by compliance with the following standards: IEC/EN 61 010-1:2001, VDE 0411 Part 1 (safety regulations) (interference resistance) (emitted interference) Technical characteristics LS 200 bar graph displays Analogue bar graph display Gas discharge Neon red Over range display Flashing Resolution 0,5% 144 x 48 mm, vertical or horizontal length 100 mm colour Black or white AC voltage AC current See measuring range card, page 9 Temperature Resistance Frequency Supply voltage 24 V AC 115/230 V AC 24 V DC Limit values Number 4 Adjustable via Potentiometers Display on the scale Pointers Signalling LED Outputs 4 relays Hysterese Approximately 0.5 % Versions 1 measurement input, no limit value LS 210 1 measurement input, 2 limit values LS 212 2 measurement inputs, no limit value LS 220 2 measurement inputs, 4 limit values LS 224 5

LS 300 Quasi-analogue bar graph meters 144 x 36 mm All measured values at a glance 300 series bar graph displays in the are robust, quasianalogue display devices with one or two light bars 101 segments per light bar In addition, depending on the type, limit relays can be included The zero point and full-scale value of the light bars are independent of each other and can be adjusted separately Buttons on the front side enable segment tests and brightness adjustment 2 limit values can be set on the front side and displayed Limit breaches are signalled Serial interface Installable in any location, vibration-resistant Front dimensions: 144 x 36 mm to DIN 43718 Installation depth: 186 mm Our bar graph displays comply with the regulations defined by the European Directives 73/23/EEC and 89/336/EEC, as verified by compliance with the following standards: IEC/EN 61 010-1:2001, VDE 0411 Part 1 (safety regulations) (interference resistance) (emitted interference) Technical characteristics LS 300 bar graph displays Analogue bar graph display LED line Red or green Over range display Flashing Resolution 1.0% Dot display or flashing display 144 x 36 mm, vertical or horizontal length 100 mm colour Black or white AC voltage AC current See measuring range card, page 9 Temperature Resistance Frequency Supply voltage 24 V AC 115/230 V AC 24 V DC 48 V DC Limit values Number 2 Adjustable via Potentiometers Display on the scale LED bar or LED dot Signalling LED Outputs 2 relays Hysteresis Approximately 1.0 % Versions 1 measurement input, no limit value LS 310 1 measurement input, 2 limit values LS 312 2 measurement inputs, no limit value LS 320 Analogue output Optional 0...10 V or 0/4...20 ma 6

LS 40 Quasi-analogue bar graph meters 96 x 24 mm Bar graph displays serve to display measurement signals visually. It is generally possible to connect sensors directly, or via measuring transducers. Depending on the visual resolution of the values to be displayed, bar graph displays are subdivided into trend indicators, overview indicators, and measuring instruments.. All measured values at a glance Electronic panel-mounted measuring instrument with LED light bar 41 individual LEDs Measuring range adjustable via DIP switches ± 25 % range adjustment for all measuring ranges LED colours freely selectable Dot or bar display selectable Brightness setting via adjustable voltage Over range display via flashing LEDs Horizontal or vertical installation possible Installable in any location, vibration-resistant Front dimensions: 96 x 24 mm to DIN 43718 Installation depth: 84 mm Technical characteristics LS 40 bar graph displays Our bar graph displays comply with the regulations defined by the European Directives 73/23/EEC and 89/336/EEC, as verified by compliance with the following standards: IEC/EN 61 010-1:2001, VDE 0411 Part 1 (safety regulations) (interference resistance) (emitted interference) Analogue bar graph display 41 bar LEDs (2x5 mm) Red (other colours available on request) Over range display Flashing Resolution 2,5% 96 x 24 mm, vertical or horizontal length Approximately 80 mm colour Black or white 0...150 mv to 0...200 V DC Input resistance 50 kω /V 0...20 ma, 4...20 ma DC Voltage drop via shunt: 200 mv Supply voltage Working temperature 0 to 50 ºC Storage temperature 20 to +70 ºC Current consumption Installation dimensions Housing faceplate 5 V DC, not galvanically isolated 24 V DC Max. 250 ma with bar display, max. 50 ma with dot display 91 0.5 x 22,5 0.3 mm Closed, black thermoplastic Black plastic 7

LK 75 Quasi-analogue bar graph meters 75 x 38 mm Bar graph displays serve to display measurement signals visually. It is generally possible to connect sensors directly, or via measuring transducers. Depending on the visual resolution of the values to be displayed, bar graph displays are subdivided into trend indicators, overview indicators, and measuring instruments. All measured values at a glance Electronic panel-mounted measuring instrument with LED line 21 individual LEDs LED colours freely selectable Dot or bar display selectable Brightness setting via adjustable voltage Over range display via flashing LEDs Horizontal or vertical installation possible Installable in any location, vibration-resistant Front dimensions: 75 x 38 mm Installation depth: 43 mm Our bar graph displays comply with the regulations defined by the European Directives 73/23/EEC and 89/336/EEC, as verified by compliance with the following standards: IEC/EN 61 010-1:2001, VDE 0411 Part 1(safety regulations) (interference resistance) (emitted interference) Technical characteristics LK 75 bar graph displays Display 21 round LEDs (2.5 mm diameter) Red (other colours available on request) Over range display Flashing Resolution 5% 75 x 38 mm, vertical or horizontal length Approximately 51 mm colour Black or white 0...60 mv to 0...200 V DC Input resistance 50 kω /V 0...1 ma to 0...200 ma, 4...20 ma DC Voltage drop via shunt: 200 mv Supply voltage Working temperature 0 to 50 ºC Storage temperature 20 to +70 ºC Current consumption Housing faceplate 5 V DC, not galvanically isolated Max. 250 ma with bar display Max. 50 ma with dot display Closed, black thermoplastic Black plastic 8

MEASURING RANGE CARDS for LS 200 and LS 300 Measuring range Range suppression Measuring range Range suppression AC voltage (Sinusoidal) Measuring range Frequency range AC current (Sinusoidal) Measuring range Voltage drop Frequenzbereich True RMS AC voltage Messbereich Frequency range True RMS AC current Measuring range Voltage drop Frequency range 0...10 mv to 0...250 V/overvoltage 350 V max. Up to 50% of the full-scale value 0...20 µa to 0...200 ma/overload 0.5 W max. Up to 50% of the full-scale value 0...60 mv to 0...250 V/overvoltage 350 V max. 10 Hz...35 Hz...2kHz...4 khz 0...10 µa to 0...1 A/overload 0.5 W max. 60 mv approx. 10 Hz...35 Hz...2 khz...4 khz 0...60 mv to 0...250 V/overvoltage 350 V max. DC, 15 Hz...10 khz 0...2 ma to 0...2A/overload 0.5 W max 60 mv approx DC, 15 Hz...10 khz Frequency measurement Measuring range 20 Hz...2 khz Maximum input Input voltage range up to 25 V: 100 V Input voltage range up to 250 V: 350 V Temperature with thermocouple Measuring range NiCr-Ni (K) 0...1200 ºC Fe-CuNi (J or L) 0...1900 ºC Cu-Cu-Ni (T or U) 0...1600 ºC PtRh-Pt 10% (S) 400...1700 ºC PtRh-Pt 13% (R) 500...1700 ºC Temperature resistance thermometer Pt 100 200 ºC...850 ºC Resistor or potentiometer 20 Ω...20 kω Order information (example) Model, scale: LS 224, vertical scale, black Limit values: Measurement input 1: 2 max. contacts, fail safe Measurement input 1: 0...100 V, bar display 0...100% Measurement input 2: 1 min. / 1 max. contact, inverse Measurement input 2: 0...20 ma, dot display 0...4 bar Analogue output 1: 0...20 ma Auxiliary voltage: 24 V DC Analogue output 2: 0...10 V Certificates GOST certificate DIN EN ISO 9001:2000 certificate 9

PRODUCT OVERVIEW Copy, mark product boxes of interest and fax back Fax no. +49 (0)911/3502-307 Sender: Analogue display units Complete measuring instrument family for current, voltage, power, power factor, frequency, bimetal ammeters Housing as per DIN, square/ rectangular shape Changeable scales Subassembly and panel-mounted devices Measuring transducers For all heavy current values and process values In accordance with DIN EN 60688 Programmable, up to 4 outputs Class 0.5 Compact design 22.5/100 mm Screw terminals, or DIN standard snap fastening Digital measuring instruments Current, voltage, temperature and process control LED and LCD displays 2.000 to 4.0000 digits DIN panel-mounted devices 39 different device types Appliance testers In accordance with VDE 0701/0702 Panel-mounted and portable Analogue or digital display Protective conductor resistance Insulation Substitute leakage current measurement/differential current 10

Contact devices For all electrical values Pt 100 and thermocouples 1 or 2 limit values Quiescent or operating current switching 7 housing sizes Text displays/printers 4 different versions 1 and 2 lines 16/80 characters Protocol panel printers Paper re-roll mechanism Bar graph displays Analogue and digital display 1 or 2 measurement channels Fluorescent display or LEDs Up to 4 adjustable limit values Bar or point display Panel-mounted DIN size housings Probes Differential probes up to 1.5 kv Passive probes up to 450 MHz SMT probes and measuring accessories Modular probes High voltage probes up to 40 kv HF probes and demodulator probes Accessories Current transducers, class 0.5 up to 2000 A Shunts to DIN 43703 Measuring instrument selector switches Switch position indicators Power adapters 11

INTERNET You are very welcome to visit our website You can find data sheets and user manuals for the products in this catalogue under Bar Graph Displays on our website. You can send us an enquiry message under Agencies. www.klinkmann.com Helsinki tel. +358 9 540 4940 automation@klinkmann.fi St. Petersburg tel. +7 812 327 3752 klinkmann@klinkmann.spb.ru Moscow tel. +7 495 641 1616 moscow@klinkmann.spb.ru Yekaterinburg tel. +7 343 376 5393 yekaterinburg@klinkmann.spb.ru Mineralnye Vody tel. +7 879 226 1934 pyatigorsk@klinkmann.spb.ru Samara tel. +7 846 342 6655 samara@klinkmann.spb.ru Кiev tel. +38 044 495 3340 klinkmann@klinkmann.kiev.ua Riga tel. +371 6738 1617 klinkmann@klinkmann.lv Vilnius tel. +370 5 215 1646 post@klinkmann.lt Tallinn tel. +372 668 4500 klinkmann.est@klinkmann.ee Мinsk tel. +375 17 200 0876 minsk@klinkmann.com