URC Utility Relay Company

Similar documents
CURRENT PROTECTION RELAY SMPR-1

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Westinghouse Power Circuit Breakers

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

MicroVersaTrip Plus & MicroVersaTrip PM Conversion Kits for Allis Chalmers Power Circuit Breakers

Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units

GE Power Management. MMII Intelligent MCC Controller

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

DEH-433. Warnings, Cautions, and Notes as used in this publication

Modbus Communications October Programming Meters fitted with the Modbus option have two additional stages in the front panel programming menu.

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Energy Management System. Operation and Installation Manual

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

DNP3 Communications Protocol

DEB Setup Video. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay

Copyright: December 2017 Nidec Issue: E

How to control and monitor up to 16 Motor Insight motor protection relays via an HMi and Modbus serial

A12B DNP 3.0 SERIAL & ETHERNET (TCP/IP) SCADA INTERFACE

GE Entellisys Low Voltage Switchgear. System Test Kit. User Manual

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

H704-42(H)(E), H704-42/1(H)(E)

MPSC Microprocessor-based protection and metering devices for low voltage power circuit breakers. ABB Power Distribution

Compact NSX communication

DNP 3.0 Serial (RS232/RS485) and Ethernet (TCP/IP) SCADA Interface for TPSD/A36D Chargers with S2A-205T Option 21P or 57T or 57U. Setup Instructions

Control Techniques Variable-Speed Drive (VSD) Interface to E2 v and Above

installation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE

AND OPTIONAL ACCESSORIES

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

Installation and Programming Manual

Contents 1 Warnings, Cautions, and Notes Description Features... 1

WaveStar. Color Monitor. Setup and Operation. Ctrl Nr: PM Revision: 003

7SR21 Non-Directional 7SR22 Directional Overcurrent Relay

Quick Start Installation Guide

Optidrive Applications Support Library

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL. Total System Manager

MULTI-LINE 2 APPLICATION NOTES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

Metasys Integrator United Power Application

Protection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

File E Project 98NK15665A. Issued January 26, 1999 Revised December 21, 2016 REPORT

PowerLogic ION6200 Serial Communications Protocol and ION / Modbus Register Map

DEH-503. Warnings, Cautions, and Notes as used in this publication

EnCell Battery Cell Monitor

Optidrive Applications Support Library

PM130 Powermeters Reference Guide Modbus Communications Protocol

TT /12b INSTALLATION INSTRUCTIONS. Introduction

Lowering Lifecycle Costs

Setup Instructions. This manual is only valid for A12B Chargers equipped with the following: S2A-225C card with software version P225C0630

Enercept H8035/H8036 Modbus Energy Meter Networked kw/kwh Transducers

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Cellwatch System Overview

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

For normal duty, design the VFD voltage level at 480 Volt, 3 Phase, 60 Hertz. (In Canada, 600 Volt, 3 Phase, 60 Hertz.)

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

NEW ERA METER. Installation & Operation Guide NE METER

Having communication issues? Model 6 intelligent Motor Control Centers communicate on all platforms. Make the most of your energy SM

PM130 Powermeters Reference Guide ASCII Communications Protocol

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

PRELIMINARY MANUAL. DC8-50-V3 Current measurement system

1.1 Remote Annunciator Controller (RAC) and 1 Switch (ATC-600/800) via Modbus TCP/IP Ethernet Gateway (PXG-200/400/600E)

BACnet Flow Controller for Fan Filter Units

Modbus Communications Board

EQ5 SERIES Quick Start Guide for Constant Torque Applications

Mounting and Connections

SACE Emax 2 Specification guide

Grid Automation Controller COM600 How it fits into the Smart Grid?

Instruction Manual. Save These Instructions. Centrifugal Compressor Control System. Model Xe-145F Modbus. Instruction Manual

For more detailed instruction, see the KTA-282 user manual. This document is a condensed version; intended as a reference.

ABB LVP&S Training AC500 to EMAX Modbus RTU ABB Automation Technologies

Compressor Controller MAM 890

Automate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control

Power System Network Simulator (PSNsim)

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Emergency Transfer Controls. Your #1 Source for Control Upgrades on Automatic Transfer Switches & Breaker Transfer Schemes

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

For more information Contact with details of the application.

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

WattmonMEGA Remote Monitoring & Control Platform

MODULAR CIRCUIT MONITORING SYSTEM

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

* A8* GE Grid Solutions. Generator Management Relay COMMUNICATIONS GUIDE

6222 Two Door Module Technical Operations Manual

SUMMARIZE MEASUREMENT AND PROTECTION RELAY SMPR-1

Installation Instructions. Procon IP-32M wir-1_ MITSUBISHI ELECTRIC

Equipment Operation & Maintenance

Ocean Controls KT-5193 Modbus Programmable Stepper Motor Controller

ISGS. Intelligent SwitchGear System The Flexible Solution

Canlan INSTALLATION MANUAL

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016

E2 Modbus RTU Register Map

MXM-50. Modbus Interface for Mitsubishi Air-Conditioning. Installation and User Guide.

GE Industrial Solutions. DET-756 Installation Instructions ASPMETER Panelboard Monitoring System

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

MIC-2 Multi-instrument DATA SHEET

Transcription:

communications i-comm modbus / rs-485 AC-PRO Communicating Trip Units instruction manual ZERO-Hertz Communicating Trip Units URC Utility Relay Company Chagrin Falls, OH 44023 Phone: 888.289.2864 www.utilityrelay.com

Table of Contents 1.0 Introduction ------------------------------------------------------ 1 2.0 AC-PRO Communications Components ------------------- 2 2.1 AC-PRO Trip Unit ----------------------------------------------- 2 2.2 PT Module --------------------------------------------------------- 2 2.3 AC-PRO Breaker Wiring ---------------------------------------- 3 3.0 ZERO-Hertz Communications Components -------------- 4 3.1 ZERO-Hertz Trip Unit ------------------------------------------- 4 3.2 ZERO-Hertz Breaker Wiring ----------------------------------- 5 4.0 System Components - Computer Hardware -------------- 6 4.1 RS-485 Direct ----------------------------------------------------- 6 4.2 RS-232 to RS-485 Conversion --------------------------------- 7 4.3 Ethernet ------------------------------------------------------------ 8 4.4 LCI Ethernet ------------------------------------------------------ 9 5.0 System Components Software------------------------------ 9 5.1 Trip Unit Programming ------------------------------------------ 10 5.2 MODBUS --------------------------------------------------------- 10 5.3 DDE Addressing (with EXCEL TM )----------------------------- 11 6.0 Technical Support ---------------------------------------------- 11 Appendix A AC-PRO MODBUS RTU Item Names ---------------- 12 Appendix B ZERO-Hertz MODBUS RTU Item Names ------------ 15 January 2013 Revision 1.4

AC-PRO / ZERO-Hertz, Communications System - Instruction Manual 1.0 Introduction Creating a complete power monitoring and communications system for a low voltage power distribution system is easy with Utility Relay Company s AC-PRO and ZERO-Hertz communicating trip unit. The trip units communicate using industry standard MODBUS RTU protocol through a single shielded twisted pair wire connected to the RS-485 port. A number of trip units can be daisy-chained together to simplify installation. Information available from an AC-PRO trip unit at each breaker includes: Currents, 3-phase (±2% accuracy for currents between 10% and 150% of the CT rating) Voltages, 3-phase KW, 3-phase (±5% accuracy for currents between 10% and 150% of the CT rating) KWH, Total KVA, 3-phase Power Factor Data Breaker Position Overload and Alarm Conditions Last Trip Data Phase Currents at the Time of Trip Trip Counter Information available from a ZERO-Hertz trip unit at each breaker includes: DC Current ((±10% accuracy for currents between 10% and 150% of the transducer rating) Ground Fault Current (if applicable) Current Direction Overload and Alarm Conditions Last Trip Data Trip Current at the Time of Trip Trip Counter A host PC running OPC software with Modbus device drivers collects information from the trip units. The driver interrogates each trip unit individually and reports that information back to the host PC applications on a continual basis. Additional trip units can be added to the system by simply providing the new trip unit s ADDRESS to the OPC software. AC-PRO and ZERO-Hertz trip units are compatible with the MODBUS RTU communication protocol supplied with most HMI systems such as Wonderware s InTouch TM, Intellution TM, Square D s PowerLogic SMS-3000 TM and ION Enterprise TM, and Power Measurements PEGASYS TM. Page 1

Utility Relay Company 2.0 AC-PRO Comm. Components An AC-PRO MODBUS Communications system consists of the following hardware components: 1. AC-PRO Trip Unit and breaker retrofit components. 2. Host PC (supplied by others). 3. Cabling Topology (supplied by others). Additional components to consider include: 1. OPC software with Modbus device drivers (supplied by others). 2. Modbus RTU/Ethernet converter (supplied by others). 3. Human-Machine Interface (HMI) System (supplied by others). 2.1 AC-PRO Trip Unit The communicating AC-PRO trip unit is an enhanced version of the standard AC-PRO trip unit with the addition of power monitoring and communications capability. The communicating AC-PRO trip unit contains a communications circuit board, which incorporates an RS-485 port and a PT Module connector; both located on the bottom of the trip unit. In addition to its power monitoring and communications capability, the communicating AC-PRO trip unit has all of the protective functions and features of a standard AC-PRO trip unit. Two addition setpoints must be programmed in to the communicating trip unit during commissioning to enable the communications functions. See Section 5.1 Trip Unit Programming. 2.2 PT Module The PT Module mounts directly on the circuit breaker and connects to the communicating AC-PRO via a preassembled wiring harness. In addition to monitoring the individual phase voltages, the PT Module also provides continual power to the communicating AC-PRO so that the trip unit can continue to communicate its status even if the breaker is open or not carrying current. The PT Module also features two addressable relays which can be used to establish a mini-scada system to control electrical operated breakers from one central PC location. A PT Module, wiring harness, and mounting hardware are provided with each communicating AC-PRO complete retrofit kit. Page 2

PUSH TO ADJUST DISPLAY CONTRAST PUSH TO VIEW LAST TRIP DATA AND SETTINGS AC-PRO / ZERO-Hertz, Communications System - Instruction Manual 2.3 AC-PRO Breaker Wiring The communicating AC-PRO is provided with a quick disconnect communications cable assembly. The cable assembly features a heavy-duty twist-lock connector and a terminal block, which mounts inside the switchgear. The purpose of the terminal block is to provide a connection location for the twisted pair wire as it is daisy-chained from cell to cell in a switchgear lineup. This enables any individual communicating AC-PRO (mounted on a circuit breaker) to be removed without disrupting communications between the other communicating AC-PRO trip units. AC TRIP UNIT With 9V Lithium Long-Life Battery PICK-UP SELF TEST OK SAVE REVIEW UTILITY RELAY COMPANY Page 3

Utility Relay Company 3.0 ZERO-Hertz Comm. Components A ZERO-Hertz MODBUS Communications system consists of the following hardware components: 1. Communicating ZERO-Hertz Trip Unit and breaker retrofit components. 2. Host PC (supplied by others). 3. Cabling Topology (supplied by others). Additional components to consider include: 4. OPC software with Modbus device drivers (supplied by others). 5. Modbus RTU/Ethernet converter (supplied by others). 6. Human-Machine Interface (HMI) System (supplied by others). 3.1 ZERO-Hertz Trip Unit The ZERO-Hertz trip unit is available in four models: Method of DC Current Sensing Model Number: Transducers Only Transducer or Shunt Input Communications B-201 YES B-202 YES YES B-203 YES B-204 YES YES Trip unit models B-202 and B-204 are equipped with an RS-485 MODBUS communications port. This port allows the trip unit to communicate with a host PC or other RS-485-based communications system. In addition to its continuous DC current monitoring and communications capability, the communicating ZERO-Hertz has all of the protective functions and features of a non-communicating ZERO-Hertz trip unit. Two addition setpoints must be programmed in to the communicating trip unit during commissioning to enable the communications functions. See Section 5.1 Trip Unit Programming. Page 4

AC-PRO / ZERO-Hertz, Communications System - Instruction Manual 3.2 ZERO-Hertz Breaker Wiring The communicating ZERO-Hertz is also provided with a quick disconnect communications cable assembly. The cable assembly features a heavy-duty twist-lock connector and a terminal block, which mounts inside the switchgear. The purpose of the terminal block is to provide a connection location for the twisted pair wire as it is daisy-chained from cell to cell in a switchgear lineup. This enables any individual communicating ZERO-Hertz to be disconnected without disrupting communications between the other trip units. WITH QUICK-TRIP With 9V Lithium Long-Life Battery PICK-UP SELF TEST OK ENTER MENU UTILITY RELAY COMPANY Page 5

Utility Relay Company 4.0 System Components-Computer Hardware URC trip units communicate over the RS-485 interface at 9600 Baud, with 8 data bits, 1 stop bit and no parity using the Modbus RTU communications protocol. There are four simple hardware configurations to connect between a PC and a communicating URC trip unit on a breaker. 4.1 RS-485 Direct Connecting trip units directly to a PC is an easy way to set up a stand-alone system. The major benefit is that a stand-alone system is that it does not require a large initial investment in hardware. The system can start out small, yet it is flexible enough to allow additional trip units to be added to the system at any time. Workstation SUBSTATION #1 Up to 32 trip units can be daisychained together. SUBSTATION #2 SUBSTATION #3 As system demands grow, additional twisted pairs of wire can be added, each twisted pair capable of supporting an additional 32 AC-PRO or ZERO-Hertz communicating trip units. The host PC can also be connected to a Local Area Network (LAN), allowing other computer sites access to AC-PRO information. Cable requirements: Belden 9463 shielded twisted pair (or equivalent) cabling is recommended Maximum cable length is 4000 feet. Page 6

AC-PRO / ZERO-Hertz, Communications System - Instruction Manual 4.2 RS-232 to RS-485 Conversion RS-232 communications is a convenient method to periodically monitor trip units without incurring the expense of a network. RS-232 to RS-485 converters and hardware are readily available and inexpensive. Using a Laptop When continual power monitoring and communications is not necessary, a laptop computer is a very useful tool. A substation can be wired for communications with the communications cable terminating at an inexpensive RS-232 to RS-485 converter located in the substation. When required, a laptop computer can be connected directly to the RS-232 computer for periodic monitoring. At any time, the RS-232 to RS-485 converter can be removed, and the substation can be connected to a larger power monitoring system with the addition of an LCI (see Section 4.4) or other RS-485 to Ethernet Converter. Laptop Computer RS232 to RS485 RS232 to RS485 SUBSTATION #1 Up to 32 trip units can be daisychained together. RS232 to RS485 SUBSTATION #2 SUBSTATION #3 RS-232 Converters Most, if not all, RS-232 to RS-485 converters and boards will have 4 wire connections TX+, TX- RX+, and RX-. The trip units use a 2 wire connection system, so at some convenient point, usually right at the converter or board connector, connect as follows: TX+ and RX+ together TX- and RX- together Shielded twisted pair cable should be used between the RS-232 to RS-485 converter and the trip units (Belden 9463 or equivalent cable is recommended). Page 7

Utility Relay Company 4.3 Ethernet With the addition of an RS-485 to Ethernet Converter an existing Local Area Network (LAN) can be used to carry data between trip units and the PC. Converters are widely available from a variety of industrial computer manufacturers. RS-485 to Ethernet Converters are designed to be compatible with a TCP/IP network environment and typically connect to a LAN using standard 10Base-T modular CAT-5 cabling. These converters offer a relatively inexpensive means of connecting to a LAN. RS-485 Converter RS-485 Converter RS-485 Converter Workstation Ethernet Workstation SUBSTATION #1 Up to 32 trip units can be daisychained together. SUBSTATION #2 SUBSTATION #3 Page 8

AC-PRO / ZERO-Hertz, Communications System - Instruction Manual 4.4 LCI Ethernet The LCI (Local Communications Interface), manufactured by Utility Relay Company, is a substation monitor that continuously monitors up to 32 AC-PRO and/or ZERO-Hertz communicating trip units that are connected to the LCI s RS-485 port. The LCI offers three key benefits: 1. The 4-line X 20-character display provides easy monitoring of a critical power and trip data from any trip unit connected to the RS-485 port. 2. The built-in Ethernet port acts as a Modbus RTU to Modbus Ethernet converter and easily connects to a LAN with a simple CAT-5 cable. A unique IP address for the LCI is user-programmable from the LCI s front panel. 3. Embedded Web Pages in the LCI provide critical information across the LAN with no additional software to install or setup. Information can be accessed by typing the LCI s IP address in the command line of any standard web browser on the LAN. Contact Utility Relay Company for more information about the LCI. Workstation Ethernet Workstation LCI LCI LCI SUBSTATION #1 Up to 32 trip units can be daisychained together. SUBSTATION #2 SUBSTATION #3 5.0 System Components - Software In addition to AC-PRO and/or ZERO-Hertz communicating trip units equipped with an RS-485 port, the following additional software may be required: 1. OPC software with a Modbus device driver. 2. EXCEL TM or LOTUS 1-2-3 TM can be used to view information provided by the OPC software. 3. Human-Machine Interface (HMI) System. These systems are used to view trip unit information graphically and often contain their own compatible MODBUS Driver. Page 9

Utility Relay Company 5.1 Trip Unit Programming Both the AC-PRO and the ZERO-Hertz communicating trip units have two additional programmable setpoints that are not found on the non-communicating trip units. Those two setpoints are ADDRESS REPLY DELAY These setpoints need to be programmed during the normal commissioning of the trip unit (Refer to the section on Commissioning in the AC-PRO or ZERO-Hertz Instruction Manual). The setpoints appear after all of the Pick-Up and Delays settings have been made. ADDRESS Each trip unit that shares the same twisted pair must have a unique address. The address is selectable from 1 to 127 in increments of 1. In most applications only addresses 1 thru 32 will be used due to the limitations of RS-485 communications. The ADDRESS identifies each individual trip unit connected to the same twisted pair wire. NOTE: Two trip units can have the same ADDRESS as long as they are not connected to the PC, Ethernet converter or RS-232 converter via the same twisted pair cable. REPLY DELAY The REPLY DELAY set point is the minimum delay between the trip unit s receipt of a MODBUS packet and its reply. Adjusting it enables the trip unit to operate properly with other manufacturers MODBUS RS-485 connections. The reply delay can be either 5 or 10 milliseconds. The factory default of this set point is 5 milliseconds. 5.2 MODBUS The OPC software with Modbus device drivers runs on the Host PC and communicates with the trip units via Modbus communications protocol. It creates the communications messages, sends them, and retrieves the responses. This data can then be shared with most WINDOWS TM programs requesting information (via DDE). DDE is supported by most HMI systems. Other programs which accept DDE include EXCEL TM, WORD TM and LOTUS 1-2-3 TM. These programs do not contain OPC software. A downloadable version of OPC software with Modbus device drivers (both Modbus RTU and Modbus Ethernet) from KEPWARE TM (along with installation instructions) is available at: http://www.utilityrelay.com/products/communications.html The free version of this software provides a 2-hour continuous runtime environment with an unlimited number of restarts. The MODBUS Driver runs in the background on the host PC and immediately begins to communicate with all of the trip units connected to the PC when the program is started. The only time that the software needs to be modified is when a trip unit is added or removed from the system. Page 10

AC-PRO / ZERO-Hertz, Communications System - Instruction Manual 5.3 DDE Addressing with EXCEL TM Dynamic Data Exchange (DDE) is a programming format that allows most programs running under WINDOWS TM to request and receive data from other programs. Programs such as EXCEL TM or LOTUS 1-2-3 TM use DDE requests to get specific data from OPC software that supports Modbus device drivers. DDE requests include a formatted address of the data being sought. WINDOWS TM is responsible for processing those requests and retrieving data from the MODBUS-DDE Driver. DDE data consists of the following components: 1. DDE Source Name 2. Topic Name 3. Item Name DDE Source Name This is the name of the DDE Driver being used. Topic Name This is the name of the trip unit to be addressed. The Topic Name must be defined in the MODBUS- DDE Driver (by its ADDRESS and COM port or TCP/IP settings). Item Name The data point to read or write. Item Names are frequently numbers, but are still called Names. The format of a DDE address is as follows: DDE SourceName TopicName! ItemName For example, in Microsoft Excel TM, the following command could be typed into a cell to retrieve a piece of data (NOTE: The following syntax is for InTouch Wonderware): MODBUS BREAKER1! 256 IR Where: MODBUS is the DDE Source Name. BREAKER1 is the Topic Name defined by the user using MODBUS. 256 IR is the Item Name of the desired piece of information from the trip unit. NOTE: The AC-PRO and ZERO-Hertz are compatible with most MODBUS drivers. You will need to consult the specific MODBUS driver manufacturer for the proper syntax. See Appendix A for a complete list of available Item Names for AC-PRO trip units. See Appendix B for a complete list of available Item Names for ZERO-Hertz trip units. 6.0 Technical Support For technical support, contact Utility Relay Company 888-289-2864, or visit us on the web at: www.utilityrelay.com Page 11

Utility Relay Company Appendix A AC-PRO MODBUS RTU Item Names PRODUCT UPDATES THAT REQUIRED NEW MODBUS (DDE) ITEMS Date February 1, 2003 February 1, 2006 November 1, 2011 New AC-PRO feature Kilowatt Hours Quick-Trip KWH Did Any Old Register Addresses Change? Yes The old Register Address are shown in italics, to the left of the new Register Address. No No Old Register Address Item Register Address Description (Data Point Name) Unit Size Data Type 83 Force Reset N/A Word OC 84 Force Trip N/A Word OC 86 Force Clear Last Trip Data N/A Word OC 111 Force Clear KW-Hrs (after 2/1/03) N/A Word OC 112 Force Relay 1 (on for 100mS) N/A Word OC 113 Force Relay 2 (on for 100mS) N/A Word OC 256 Current Phase A Amps Word IR 257 Current Phase B Amps Word IR 258 Current Phase C Amps Word IR 259 Current GF Amps Word IR 260 Current UB % Word IR 262 Voltage AG Volts Word IR 263 Voltage BG Volts Word IR 264 Voltage CG Volts Word IR 265 Voltage AB Volts Word IR 266 Voltage BC Volts Word IR 267 Voltage CA Volts Word IR 268 KW Phase A kw Word IR 269 KW Phase B kw Word IR 270 KW Phase C kw Word IR 272 271 KVA Phase A kva Word IR 273 272 KVA Phase B kva Word IR 274 273 KVA Phase C kva Word IR 274 KW-Hrs Register 3 0.1 KWH * 2 32 Word IR 275 KW-Hrs Register 2 0.1 KWH * 2 16 Word IR 276 KW-Hrs Register 1 0.1 KWH Word IR 271 277 KW Signs & Lead/Lag PF N/A Word IR Bit 0; Phase A, 1 = Lead PF, 0 = Lag PF Bit 1; Phase B, 1 = Lead PF, 0 = Lag PF Bit 2; Phase C, 1 = Lead PF, 0 = Lag PF Bit 8; Phase A KW, 1 = Pos, 0 = Neg Bit 9; Phase B KW, 1 = Pos, 0 = Neg Bit 10; Phase C KW, 1 = Pos, 0 = Neg Bit 11; KW-Hrs, 1 = Pos, 0 = Neg (N/A/ for trip units made before 2/1/2003) Page 12

AC-PRO / ZERO-Hertz, Communications System - Instruction Manual Old Register Address Item Register Address Description (Data Point Name) Unit Size 275 278 Alarm Code N/A Word IR Bit 0; 1 = Trip Output Bit 1; 1 = Current > LT Pickup Bit 3; 1 = Actuator Disconnected Bit 4; 1 = Memory Error Bit 6; 1 = A/D Error Bit 8; 1 = Breaker Closed, 0 = Breaker Open or Feature Unused Bit 9; 1 = Times 10 Range Bit 11; 1 = Divide by 10 Range 276 279 CT Rating Amps Word HR 277 280 LT Pickup Amps Word HR 278 281 LT Delay Sec. Word HR Value stored is 2 times the actual delay in seconds 279 282 ST Pickup Amps Word HR 280 283 ST Delay Sec. Word HR Binary 0 =. 07 Sec Delay Band Binary 1 =.10 Sec Delay Band Binary 2 =.15 Sec Delay Band Binary 3 =.20 Sec Delay Band Binary 4 =.30 Sec Delay Band Binary 5 =.40 Sec Delay Band (N/A for trip units made before 2/1/03) 281 284 ST I 2 T N/A Word HR Bit 0; 0 = Off, 1 =On 282 285 I Pickup Amps Word HR 283 286 GF Pickup Amps Word HR 284 287 GF Delay Sec. Word HR Binary 0 =.10 Sec Delay Band Binary 1 =.20 Sec Delay Band Binary 2 =.30 Sec Delay Band Binary 3 =.40 Sec Delay Band Binary 4 =.50 Sec Delay Band 285 288 GF I 2 T N/A Word HR Bit 0; 0 = Off, 1 = On 286 289 U/B Pickup % Word HR 287 290 U/B Delay Sec. Word HR 288 291 Trip Unit Address N/A Word HR 289 292 Reply Delay ms Word HR 290 293 Last Trip Current Phase A Amps Word IR 291 294 Last Trip Current Phase B Amps Word IR 292 295 Last Trip Current Phase C Amps Word IR 293 296 Last Trip Current GF Amps Word IR 294 297 Last Trip Current U/B % Word IR 295 298 Last Trip Code N/A Word IR Binary 0 = Instantaneous Binary 1 = LT Binary 2 = ST Binary 3 = GF Binary 4 = Unbalanced Binary 5 = Forced Trip Thru Communications Binary 7 = QT Ground Fault (after 2/1/06) Binary 8 = QT Instantaneous (after 2/1/06 Binary 65535 = No Last Trip Binary 6 = Close Fault Binary 11 = I-Override Data Type Page 13

Utility Relay Company Old Register Address Item Register Address Description (Data Point Name) Unit Size 296 299 Trip Count Instantaneous N/A Word IR 297 300 Trip Count LT N/A Word IR 298 301 Trip Count ST N/A Word IR 299 302 Trip Count GF N/A Word IR 300 303 Trip Count U/B N/A Word IR 301 304 Trip Count Forced N/A Word IR 305 Close Fault N/A Word IR 303 306 Serial Number Byte 0 N/A Word IR 304 307 Serial Number Byte 1 N/A Word IR 305 308 Serial Number Byte 2 N/A Word IR 306 309 Serial Number Byte 3 N/A Word IR 307 310 Serial Number Byte 4 N/A Word IR 308 311 Serial Number Byte 5 N/A Word IR 309 312 Serial Number Byte 6 N/A Word IR 316 Range Multiplier 0-X1 1-X10 2-X0.1 N/A Word IR 317 Quick-Trip GF Pickup Amp Word HR 318 Quick-Trip Instantaneous Pickup Amp Word HR 319 KWH MS KWH Word IR 320 KWH LS KWH Word IR 321 Trip Count Quick-Trip GF N/A Word IR 322 Trip Count Quick-Trip Instantaneous N/A Word IR 323 Thermal Memory, 0 = Off, 1 = On N/A Word HR Data Type 324 QT-Switch, 0 = Off, 1 = On N/A Word IR Page 14

AC-PRO / ZERO-Hertz, Communications System - Instruction Manual Appendix B ZERO-Hertz MODBUS RTU Item Names Item Register Address Description (Data Point Name) Unit Size Tag Type 83 Force Reset N/A Bit DO 84 Force Trip N/A Bit DO 86 Force Clear Last Trip N/A Bit DO 87 Force Alarm Relay On N/A Bit DO 88 Force Alarm Relay Off N/A Bit DO 256 Largest Current Amps Word IR 257 Current GF Amps Word IR 258 Direction N/A Word IR Bit 0; 0 = Forward, 1 = Reverse 259 Alarm Code N/A Word IR Bit 0; 1 = Trip Output Bit 1; 1 = Current > LT Pickup Bit 3; 1 = Actuator Disconnected Bit 4; 1 = Memory Error Bit 5; 1 = Xducer Error Bit 6; 1 = A/D Error Bit 7; 1 = Alarm Relay in Alarm State Bit 8; 1 = Breaker Closed, 0 = Breaker Open or Feature Unused Bit 9; 1 = Times 10 Range Bit 10; 1 = Minus Transducer is Present 260 Last Trip Code Binary 0 = Instantaneous Binary 1 = LT Binary 2 = ST Binary 3 = GF Binary 5 = Forced Trip Thru communications Binary 7 Reverse Current Binary 8 = UV OL Binary 10 = I-QT Binary 11 = GF-QT Binary 65535 + No Last Trip N/A Word IR 261 Last Trip Current Amps Word IR 262 Last Trip Current GF Amps Word IR 263 Last Trip Direction N/A Word IR Bit 0; 0 = Forward, 1 = Reverse 264 Trip Count Instantaneous N/A Word IR 265 Trip Count LT N/A Word IR 266 Trip Count ST N/A Word IR 267 Trip Count GF N/A Word IR 269 Trip Count Forced N/A Word IR 271 Trip Count Reverse N/A Word IR 272 Trip Count UV OL N/A Word IR 274 Serial Number Byte 0 N/A Word IR 275 Serial Number Byte 1 N/A Word IR 276 Serial Number Byte 2 N/A Word IR 277 Serial Number Byte 3 N/A Word IR 278 Serial Number Byte 4 N/A Word IR 279 Serial Number Byte 5 N/A Word IR 280 Serial Number Byte 6 N/A Word IR 282 DC Input N/A Word IR Bit 0; 0 = Transducer, 1 = Shunt Page 15

Utility Relay Company Item Name Description (Data Point Name) Unit Size Tag Type 283 Transducer Rating Amps Word IR 284 LT Pickup Amps Word HR 285 LT Delay Sec. Word HR Value stored is 2 times the actual delay in seconds 286 LT & ST Thermal Memory N/A Word HR Bit 0; 0 = Off, 1 = On 287 ST Pickup Amps Word HR 288 ST Delay Sec. Word HR Binary 0 =.07 seconds Binary 1 =.10 seconds Binary 2 =.15 seconds Binary 3 =.20 seconds Binary 4 =.35 seconds 289 ST I 2 T N/A Word HR Bit 0; 0 = Off, 1 =On 291 I Pickup Amps Word HR 292 GF Pickup Amps Word HR 293 GF Delay Sec. Word HR Binary 0 =.10 seconds Binary 1 =.20 seconds Binary 2 =.30 seconds Binary 3 =.40 seconds Binary 4 =.50 seconds 294 GF I 2 T N/A Word HR Bit 0; 0 = Off, 1 = On 295 RC Pickup Amps Word HR 296 RC Delay Sec. Word HR Binary 0 =.10 seconds Binary 1 =.20 seconds Binary 2 =.30 seconds Binary 3 =.40 seconds 297 RC I 2 T N/A Word HR Bit 0; 0 = Off, 1 = On 301 Unit Address N/A Word IR 302 Reply Delay ms Word HR 303 Alarm Relay Under Comm. Control N/A Word HR Bit 0; 0 = Off, 1 = On 304 Alarm Relay on Overload N/A Word HR Bit 0; 0 = Off, 1 = On 305 Alarm Relay on Trip N/A Word HR Bit 0; 0 = Off, 1 = On 306 Alarm Relay on Error Bit 0; 0 = Off, 1 = On N/A Word HR 307 I-QT Bit 0: 0 = Off, 1 = On N/A Word HR 308 GF-QT Bit 0: 0 = Off, 1 = On N/A Word HR 309 QT-Switch Bit 0: 0 = Off, 1 = On Via Switch N/A Word IR 310 I-QT Trip Count N/A Word IR 311 GF-QT Trip Count N/A Word IR Page 16