Lenovo SAN Manager. Rapid Tier and Read Cache. David Vestal, WW Product Marketing. June Lenovo.com/systems

Similar documents
Lenovo SAN Manager - Provisioning and Mapping Volumes

Lenovo SAN Manager Rapid RAID Rebuilds and Performance Volume LUNs

Lenovo RAID Introduction Reference Information

Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide

Using the ThinkServer SA120 Disk Array

ServeRAID M5000 Series Performance Accelerator Key for System x Product Guide

Stellar performance for a virtualized world

Lenovo Database Configuration

System x Server for SAP Business One, version for SAP HANA

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN

IBM System Storage Reference Architecture featuring IBM FlashSystem for SAP landscapes, incl. SAP HANA

Using Read Intensive SSDs with Lenovo Storage V Series and IBM Storwize for Lenovo

EMC XTREMCACHE ACCELERATES ORACLE

Lenovo Database Configuration

Reduce costs and enhance user access with Lenovo Client Virtualization solutions

NST6000 UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment

Here is Your Customized Document

IBM XIV Storage System

LEVERAGING FLASH MEMORY in ENTERPRISE STORAGE

New HPE 3PAR StoreServ 8000 and series Optimized for Flash

Planning for Easy Tier with IBM System Storage Storwize V7000 and SAN Volume Controller

All-Flash Storage Solution for SAP HANA:

Understanding the Performance Benefits of MegaRAID FastPath with Lenovo Servers

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide

Benefits of Automatic Data Tiering in OLTP Database Environments with Dell EqualLogic Hybrid Arrays

Lenovo Database Configuration for Microsoft SQL Server TB

SAS 2.5-inch Hybrid Hard Drives for System x Product Guide

Nimble Storage Adaptive Flash

Copyright 2012 EMC Corporation. All rights reserved.

IBM System Storage SAN Volume Controller IBM Easy Tier enhancements in release

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture

InfoSphere Warehouse with Power Systems and EMC CLARiiON Storage: Reference Architecture Summary

IBM Tivoli Storage Productivity Center Version Storage Tier Reports. Authors: Mike Lamb Patrick Leahy Balwant Rai Jackson Shea

Accelerating storage performance in the PowerEdge FX2 converged architecture modular chassis

IBM Spectrum NAS. Easy-to-manage software-defined file storage for the enterprise. Overview. Highlights

Lenovo Validated Designs

ServeRAID C100 and C105 Product Guide

Storwize/IBM Technical Validation Report Performance Verification

IBM Storwize V7000: For your VMware virtual infrastructure

Copyright 2012 EMC Corporation. All rights reserved.

Lenovo Database Configuration Guide

A Comparative Study of Microsoft Exchange 2010 on Dell PowerEdge R720xd with Exchange 2007 on Dell PowerEdge R510

HCI: Hyper-Converged Infrastructure

EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE

Using the IBM DS8870 in an OpenStack Cloud Environment IBM Redbooks Solution Guide

PowerVault MD3 SSD Cache Overview

Entry-level Intel RAID RS3 Controller Family

HPE MSA 2042 Storage. Data sheet

Lenovo ThinkSystem RAID 930 Series Internal RAID Adapters Product Guide

Lenovo ThinkSystem RAID 530 Series Internal RAID Adapters Product Guide

Virtualization of the MS Exchange Server Environment

Eliminate the Complexity of Multiple Infrastructure Silos

Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage

vsan Mixed Workloads First Published On: Last Updated On:

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays

IBM FileNet Content Manager and IBM GPFS

Lenovo Software Defined Storage with Windows Server 2016 Datacenter Storage Spaces

Create a Flexible, Scalable High-Performance Storage Cluster with WekaIO Matrix

VEXATA FOR ORACLE. Digital Business Demands Performance and Scale. Solution Brief

EMC STORAGE FOR MILESTONE XPROTECT CORPORATE

Milestone Solution Partner IT Infrastructure Components Certification Report

VMware Virtual SAN. Technical Walkthrough. Massimiliano Moschini Brand Specialist VCI - vexpert VMware Inc. All rights reserved.

IBM System Storage DS5020 Express

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018

Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System

LSI and HGST accelerate database applications with Enterprise RAID and Solid State Drives

Reduce Costs & Increase Oracle Database OLTP Workload Service Levels:

Data Sheet Fujitsu ETERNUS DX200 S3 Disk Storage System

Data Sheet FUJITSU Storage ETERNUS DX200F All-Flash-Array

Lenovo XClarity Administrator Performance

IBM InfoSphere Streams v4.0 Performance Best Practices

Nutanix Tech Note. Virtualizing Microsoft Applications on Web-Scale Infrastructure

DS8880 High Performance Flash Enclosure Gen2

Dell EMC ScaleIO Ready Node

ADDENDUM TO: BENCHMARK TESTING RESULTS UNPARALLELED SCALABILITY OF ITRON ENTERPRISE EDITION ON SQL SERVER

DATA PROTECTION IN A ROBO ENVIRONMENT

Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades

Easily Recreate the Qtier SSD Tier

EonStor DS 3000 Series

NEC M100 Frequently Asked Questions September, 2011

Automated Storage Tiering on Infortrend s ESVA Storage Systems

GLOBAL APPLICATION & SAN ACCELERATION WITH SOLID-STATE STORAGE A WHITE PAPER

Frequently Asked Questions. s620 SATA SSD Enterprise-Class Solid-State Device

Enterprise power with everyday simplicity

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results

EMC Backup and Recovery for Microsoft Exchange 2007

SAP Applications on IBM XIV System Storage

Using IBM FlashSystem V9000 TM with the VMware vstorage APIs for Array Integration

Isilon Performance. Name

iscsi Configuration Manager Version 2.0

Data center requirements

Veritas Storage Foundation for Windows by Symantec

Intel Solid State Drive Data Center Family for PCIe* in Baidu s Data Center Environment

Nutanix Complete Cluster Date: May 2012 Authors: Ginny Roth, Tony Palmer, and Emil Flock

Assessing performance in HP LeftHand SANs

ServeRAID F GB and 800GB SAS/SATA Controllers for IBM System x Product Guide

BladeCenter HS21 XM Memory Configurations Positioning Information (withdrawn product)

Isilon Scale Out NAS. Morten Petersen, Senior Systems Engineer, Isilon Division

EMC CLARiiON LUN Shrinking with Microsoft Exchange 2007

Transcription:

Lenovo SAN Manager Rapid Tier and Read Cache June 2017 David Vestal, WW Product Marketing Lenovo.com/systems

Table of Contents Introduction... 3 Automated Sub-LUN Tiering... 4 LUN-level tiering is inflexible and inefficient... 4 SSD Read Cache... 7 Figure 3- Add Disk Group Dialog... 9 Key CLI Commands for Rapid Tier and Read Cache...9 Summary... 10 2

Introduction The Lenovo ThinkSystem DS2200, DS4200 and DS6200 SAN products are differentiated offerings with Lenovo s Storage portfolio, providing both hardware and software feature advantages. These SAN products are designed for simplicity, speed, and scalability and availability and provide the perfect blend of a high performing SAN product with a very easy-to-use interface. With simplicity at its core, the DS2200, DS4200, and DS6200 share the same software features and interface. The Lenovo SAN Manager, the operating software to manage the operational and features of the SAN products, is an easy-to-use GUI that makes complex administrative simple by automating configurations and operations. The Lenovo SAN Manager offers enterpriseclass features like: Storage Tiering & Caching, Thin Provisioning, Rapid RAID Build, Snapshots, and more. In this paper, you will learn: How to combine SSDs and HDDs to accelerate your application performance with the new automated sub-lun tiering and Sub-LUN SSD Read Cache capabilities. How to configure Lenovo SAN Manager for both Rapid Tier and Read Cache using the Storage Management Utility or CLI. Key differences between Rapid Tier and SSD Read Cache and how they optimize performance 3

Automated Sub-LUN Tiering Disk tiers are comprised of aggregating 1 or more disk groups (RAID groups) that exhibit similar characteristics in speed and density. There are 3 tiers: 1. A Performance tier with SSDs 2. A Standard tier with Enterprise SAS HDDs 3. An Archive tier with Midline SAS HDDs, dense disks with rotational latencies of 7.2K Prior to Automated Sub-LUN Tiering, LUN-level tiers are manually created and managed by using dedicated vdisks and volumes. Applications requiring the highest performance are given volumes on top of the SSD-based vdisks while those requiring the lower performance, but greater capacity are typically are dedicated to a vdisk comprised of Enterprise SAS or midline SAS HDDs. LUN-level tiering is inflexible and inefficient Manual tiers act as static repositories, trapping data in one tier during dynamic workload changes o o Cold data trapped in the performance tier limits the amount high performing disks that can be brought to bear to a dynamic workload Hot data trapped in the standard or archive tiers will underperform when needed the most; the controller cache usually isn t large enough to deal with this issue 4

Migration between tiers requires external migration software or a cumbersome, backup/restore cycle. Movement at the LUN-level is inefficient; the entire LUN must be migrated when typically only portions of the LUN are being referenced by the applications Lenovo SAN Manager alleviates all of these issues because it seamlessly migrates data between tiers on-demand. Dynamic data workloads are based upon algorithms that reveal hot data those which are consistently accessed with dynamic reads/writes. This feature is called Automated Tiering. Automated Tiering is accomplished via a concept called paging. User volumes are logically broken down into small, 4MB chunks, called pages. Pages are ranked based upon a sophisticated algorithm. The page rank is used to very efficiently select good pages to move between tiers. The result is that pages can be migrated between tiers automatically such that I/O s are optimized in realtime. Figure 1 captures this concept. Note that 3 pages have been moved from the Enterprise SAS Tier to the SSD Tier, 1 page from the Midline SAS Tier to the SSD Tier, and a single page has been moved down from the SSD Tier to the SAS Tier. Figure 1 Rapid Tier 5

In contrast to data movement at the LUN-level, the Sub-LUN nature of paging provides highly efficient data movement, a minimum of CPU and memory resources are needed to support data movement between tiers; therefore, movement can happen in real-time rather than in offline batch movements. One can monitor the migration between tiers from the Storage Management Console. Notice the IOPS status bar at the bottom Figure 2. This screen shot was captured 5 minutes after the start of a 100% random 100% write workload on a 10GB volume. The red portion of the status bar reflects those IOPS being served from the SSD tier, and the green portion of the status bar reflects those IOPS being served from the standard HDD tier. Notice that only a small portion of the IOPS are coming from the SSD tier. 6

Figure 2 Percent of IO from the Two Tiers Volumes must be created from virtual storage pools to benefit from automated tiering. Volumes created from Linear Storage Pools (previously called VDisks) cannot take advantage of the benefits of paging and sub-lun tiering. Automated SSD Tiering eliminates rigid hardware silos, cumbersome manual migration between tiers, and can improve $/IOPs metrics. SSD Read Cache A read cache is a special-purpose disk group dedicated to hold volatile copies of data within one or more SSDs. An SSD read cache is a new concept in the Lenovo SAN Manager. Some advantages of a read cache are: 7

Improved performance in read-centric workloads where maximum IOPS is crucial Requires fewer SSDs when compared to a dedicated SSD tier. o A single SSD disk can be used as a read cache for a storage pool; whereas, an SSD tier requires multiple disk to provide fault tolerance. Takes advantage of tiering-like algorithms so that only active pages are copied into the read cache. o Active pages can be from any volume within the pool. The read cache becomes active when the controller cache is saturated. The controller cache software gives hints to the system software about which pages it would like to keep, but can t. The system then copies these pages into the read cache. Reads are served from the SSD, and writes are written to both SSD and HDD. A read cache is created using the Add Disk Group dialog box. From the SMU: Click on the Pools icon in the navigation menu to the left of thesmu. Click the Action menu, and select the Add Disk Group menu item. 8

Figure 3 Add Disk Group Figure 3- Add Disk Group Dialog An example can be seen in figure 3. Notice that two SSDs are selected to act as the read cache for storage Pool A. Up to 2 SSDs may be dedicated to the read cache disk group; however, only one disk group may serve as a read cache for a pool. Once active, the read cache for a pool can contain pages from any volume within the pool that is experiencing a read-intensive workload when the controller cache is exhausted. Key CLI Commands for Tiering and Read Cache The CLI may be used to create disks groups for Automated Tiers and Read Cache. Figures 4-6 demonstrate the creation of a read cache, the viewing of 9

disk groups, and the deletion of a disk group respectively. The examples highlight a read cache, but the commands may be used for any type of tier. Figure 4 - Creating a disk group # add disk - group type read - cache pool a disks 1.21-22 Figure 5 - Viewing disk groups # show disk - groups Figure 6 - Removing a disk group # remove disk - groups MyReadCache Summary The power of Virtual Disk Groups and paging introduces great flexibility around the use of disk resources. Rapid Tier and SSD Read Cache are two high-value features built using this malleable architecture. They provide efficient, selfmanaged use of disk resources with little maintenance. LENOVO PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS 10

FOR A PARTICULAR PURPOSE. This information could include technical inaccuracies or typographical errors. Changes may be made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any performance data contained herein was determined in a controlled environment; therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems, and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. Any references in this publication to non-lenovo Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Lenovo, the Lenovo logo, System x, and ThinkServer, and ThinkSystem, are trademarks of Lenovo in the United States, other countries, or both. 11