Safety automation system solutions 0

Similar documents
Safety automation solutions

Preventa Machine Safety Products

Product Substitution Details - Safety Modules

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

XPSMC16ZPPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

XPSMC16ZP safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

XPSMC16ZCPACK safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling

Safety automation solutions

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W

XACA2074 pendant station XAC-A pistol grip - 2 push buttons 1 Emergency stop

Safety automation solutions Preventa safety modules types XPSAC, XPSAXE For Emergency stop and switch monitoring

K1B004TLH cam switch - 1 pole A - screw mounting

K1F006ALH cam switch - 6-pole A - screw mounting

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

K1D012ULH cam changeover switch - 2-pole A - screw mounting

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

TM3SAF. Main. Device short name

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

XB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

ZB5FG09 flush mounted selector switch head key pos stay put

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

TM3SAK. Main. Device short name

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

XB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

XB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC

XPSMCMDI Input expansion module with screw term

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

XCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20

XPSMCMDO Digital output pairs expansion modules with screw term

XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

ZB4BW061 light block with body/fixing collar for BA9s bulb 250V 1NO

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

XB7NG33 key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

3 Pole Contactors with AC operating coils

XCKP2110N12 limit switch XCKP - metal end plunger - 1NC +1NO - snap - 1/2NPT

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XB4BT845 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC+1NO

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XB4BW33B5 green flush complete illum pushbutton Ø22 spring return 1NO+1NC 24V

XPSMCMMX inputs 2 output pairs expansion module with screw term

Contact protection relay

XCKP2110G11 limit switch XCKP - metal end plunger - 1NC+1NO - snap - Pg11

XCKP2145N12 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

Push Buttons and Operator Interface New Product Catalog XAL Control Stations

TeSys IEC Contactors and Overload Relays

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

SR2B121FU. Price* : USD with ladder programming. 80 maat 100 V (without extension)

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

XB4BW73731B5 green flush/red projecting illuminated double-headed pushbutton Ø22 1NO+1NC 24V

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

RM4TR31 three-phase network control relay RM4-T - range V

SR2B201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

XCKD2145N12 limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

RM4JA01F current measurement relay RM4-J - range ma V AC

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

HR1S-AC Safety Relay Modules

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T

Datasheet - SRB 301LC/B-24V

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Motor protection relays

XB4BT842 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

SR3B261BD modular smart relay Zelio Logic - 26 I O - 24 V DC - clock - display

RM4JA32MW current measurement relay RM4-J - range A V AC DC

SR2A201BD. Main. <= 0.5 ma for IB...IG used as discrete input circuit. <= 5 Vfor IB...IG used as discrete input circuit V

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Zelio Control-modular measurement and control relays 1

Transcription:

Operating principle 0 Preventa safety modules types XPS BA,, XPS BF Operating principle Two-hand control stations are designed to provide protection against hand injury. They require machine operators to keep their hands clear of the dangerous movement zone. The use of two-hand control is an individual protective measure, which can safely protect only one operator. Separate two-hand control stations must be provided for each operator in a multiple-worker environment. Safety modules XPS BA, BC and BF for two-hand control stations comply with the requirements of European standard EN 574/ISO 85 for two-hand control systems. The control stations must be designed and installed such that they cannot be activated involuntarily or easily rendered inoperative. Depending on the application, the requirements of type C standards specifi c to the machinery involved must be met (additional personal protection methods may have to be considered). To initiate a dangerous movement, both operators (two-hand control pushbuttons) must be activated within an interval y 0.5 s (synchronous activation). If one of the two pushbuttons is released during a dangerous operation, the control sequence is cancelled. Resumption of the dangerous operation is possible only if both pushbuttons are returned to their initial position and reactivated within the required time interval. The safety distance between the control units and the hazardous zone must be suffi cient to ensure that when only one operator is released, the hazardous zone cannot be reached before the dangerous movement has been completed or stopped. Connections: page 8790-EN/6

Characteristics Preventa safety modules types XPS BA, Characteristics Module type XPS BA Product designed for max. use in safety related parts of control systems (conforming to EN 954-/ISO 849-) Category max. Category 4 max. Conformity to standards EN/IEC 6004-, EN/IEC 60947-5-, EN 574/ISO 85 type III A, EN 5008- Product certifications UL, CSA UL, CSA, INRS EN/IEC 6004-, EN/IEC 60947-5-, EN 574 type III C/ISO 85, EN 5008- Supply Voltage V z 4, a 5, a 0 c 4, a 4, a 5, a 0 Voltage limits - 0 + 0% (c 4 V), - 0 + 0% (a 4 V), - 5 + 5% (a 5 V), - 5 + 0% (a 0 V) - 0 + 0% (c 4 V), - 5 + 0% (a 4 V), - 5 + 5% (a 5 V), - 5 + 0% (a 0 V) Frequency Hz 50/60 Consumption VA < 0 (apparent power) < 6 Module inputs fuse protection Internal, electronic Inputs S: N/C + N/O, S: N/C + N/O Two-hand control type Conforming to EN 574/ISO 85 III A III C Synchronisation time s 0.5 maximum Control unit voltage c 4 V version V 4 4 a 4 V, 5 V, 0 V version V 4 48 Minimum voltage and current Between terminals T-T, T-T Between terminals T-T, T-T U min./i min. - c 4 V version (0 C) 8 V/0 ma 8 V/40 ma U min./i min. - a 4 V/5 V/0 V version (0 C) 8 V/0 ma 0 V/50 ma Calculation of wiring resistance RL (for only) Ω between terminals T-T, T-T as a function of the internal RL max. = supply voltage U int (terminals T-T) U int - U min. I min. Ue = true voltage applied to terminals A-A U int = supply voltage Ue - V (4 V version) (5 V, 0 V version) RL max. must not exceed 50 Ω U int between 0.5 V and 5 V, with typical value = 5 V Outputs Voltage reference Volt-free Number and type of safety circuits N/O (-4) N/O (-4, -4) Number and type of additional circuits N/C (-) N/C (-) Breaking capacity in AC-5 VA C00: inrush 800, maintained 80 Breaking capacity in DC- 4 V/.5 A - L/R = 50 ms Max. thermal current (Ithe) A 5.5 Output fuse protection, using fuses A 4 gg or 6 fast acting 4 gg conforming to EN/IEC 60947-5-, VDE 0660 part 00 Minimum current ma 0 Minimum voltage V 7 Electrical durability See page 860/ Response time ms < 5 < 0 Rated insulation voltage (Ui) V 00 (degree of pollution conforming to EN/IEC 60947-5-, DIN VDE 00 parts & ) Rated impulse withstand voltage (Uimp.) kv 4 (overvoltage category III, conforming to EN/IEC 60947-5-, DIN VDE 00 parts & ) LED display Operating temperature C - 0 + 55 Storage temperature C - 5 + 85 Degree of protection conforming to IEC/EN 6059 Terminals IP 0 Enclosure IP 40 Connections Type Captive screw clamp terminals -wire connection Without cable end Solid or fl exible cable: 0.4.5 mm With cable end Without bezel, fl exible cable: 0.5.5 mm With cable end With bezel, fl exible cable: 0.5.5 mm -wire connection Without cable end Solid or fl exible cable: 0.4 0.75 mm With cable end Without bezel, fl exible cable: 0.5 mm With cable end Double, with bezel, fl exible cable: 0.5.5 mm page 8790-EN/ Connections: page 8790-EN/6

Characteristics (continued) Preventa safety modules type XPS BF Characteristics Module type XPS BF XPS BFP Product designed for max. use in safety related parts of control systems (conforming to EN 954-/ISO 849-) Category 4 max. Conformity to standards EN/IEC 6004-, EN 574 type III C/ISO 85, EN/IEC 60947-, EN/IEC 60947-5-, DIN V VDE 080 (990), DIN V VDE 080 A (994) Product certifications UL, CSA, BIA Supply Voltage V c 4 Voltage limits - 0 + 0% Consumption W <.5 Module inputs fuse protection Internal, electronic Inputs S: N/C + N/O, S: N/C + N/O Two-hand control type III C conforming to EN 574/ISO 85 Synchronisation time s 0.5 maximum Control unit voltage V 4 V/8 ma Outputs Voltage reference Volt-free Number and type of safety circuits N/O (-4, -4) Number and type of additional circuits solid-state (type 4 V - 0 ma) Breaking capacity in AC-5 VA C00: inrush 800, maintained 80 Breaking capacity in DC- 4 V/.5 A - L/R = 50 ms Max. thermal current (Ithe) A 4. Max. total thermal current A 8.4 Output fuse protection, using fuses A 4 gg or 6 fast acting conforming to EN/IEC 60947-5-, VDE 0660 part 00 Minimum current ma 0 Minimum voltage V 7 Electrical durability See page 860/ Response time ms < 0 Rated insulation voltage (Ui) V 00 (degree of pollution conforming to EN/IEC 60947-5-, DIN VDE 00 parts & ) Rated impulse withstand voltage (Uimp.) kv 4 (overvoltage category III, conforming to EN/IEC 60947-5-, DIN VDE 00 parts & ) LED display Operating temperature C - 0 + 55 Storage temperature C - 5 + 85 Degree of protection conforming to IEC/EN 6059 Terminals IP 0 Enclosure IP 40 Connection Type Captive screw clamp terminals Captive screw clamp terminals, removable terminal block -wire connection Without cable end Solid or fl exible cable: 0.4.5 mm Solid or fl exible cable: 0..5 mm With cable end Without bezel, fl exible cable: 0.5.5 mm With cable end With bezel, fl exible cable: 0.5.5 mm With bezel, fl exible cable: 0.5.5 mm -wire connection Without cable end Solid or fl exible cable: 0.4 0.75 mm Solid cable: 0. mm, flexible cable: 0..5 mm With cable end Without bezel, fl exible cable: 0.5 mm With cable end Double, with bezel, fl exible cable: 0.5.5 mm page 8790-EN/ Connections: page 8790-EN/6 4

Selection, references Preventa safety modules types XPS BA,, XPS BF Selection Standard EN 574/ISO 85 defines the selection of two-hand controls according to the control system category. The following table details the three types of two-hand control conforming to EN 574/ ISO 85. For each type, it lists the operating characteristics and minimum requirements. Requirements of standard EN 574/ISO 85 Type I Type II Type III A B C Use of both hands (simultaneous action) Link between input and output signals Output signal inhibited Prevention of accidental operation Tamper-proof Output signal reinitialised Synchronous action (specifi ed time limit) Use of proven components (Category conforming to EN 954-/ ISO 849-) Redundancy with partial error detection (Category conforming to EN 954-/ ISO 849-) Redundancy + Self-monitoring (Category 4 conforming to EN 954-/ ISO 849-) Two-hand control station XY SBpp XPS BApp XPS BF XPS BF Meets the requirements of standard EN 574/ISO 85 Conforming to standard EN 954-/ISO 849-5605 References Description Safety modules for electrical monitoring of two-hand control stations Type conforming to standard EN 574/ ISO 85 III A Type of terminal block connection Integrated in module Number of safety circuits Additional outputs Supply Reference Weight N/O N/C a or c 4 V XPS BA50 0.00 kg a 5 V XPS BA40 0.00 XPS BApppp a 0 V XPS BA70 0.00 56054 III C Integrated in module N/O N/C c 4 V 0 0.400 a 4 V 0 0.400 pppp a 5 V 40 0.400 560075 a 0 V 70 0.400 N/O solid-state c 4 V XPS BF 0.50 Removable from module N/O solid-state c 4 V XPS BFP 0.50 XPS BFP page 8790-EN/ Connections: page 8790-EN/6 5

Connections Preventa safety modules type XPS BA XPS BA Module XPS BA associated with a two-hand control station Type III A conforming to EN 574/ISO 85 L (+) F S S A T T T T + Logic K T XPS BA A 4 N ( ) Signalling output Safety output S and S: pushbuttons. Must not be used for applications (presses) which require a type III C module (). Functional diagram of module XPS BA Supply voltage Two-hand control not activated Two-hand control activated Two-hand control not activated Supply A-A Input T-T (N/C) Input T-T (N/O) Safety output -4 (N/O) Signalling output - (N/C) Key 0 max. 500 ms max. 5 ms Response time LED details (XPS BA) Supply voltage A-A. K status (N/O safety output -4 closed). page 8790-EN/ 6

Connections (continued) Preventa safety modules type Module associated with a two-hand control station Type III C conforming to EN 574/ISO 85 L (+) F S ESC A T T T Y Y K K K T Logic K K K A T T T 4 4 N (-) S ESC: external start conditions. Y-Y: feedback loop. Output (-) must not be used as a safety circuit. It can be used for non-dangerous machine movements. Functional diagram of module Two-hand control Two-hand control activated not activated Two-hand control deactivated Mushroom head S (N/C) Mushroom head S (N/O) Mushroom head S (N/C) Mushroom head S (N/O) Feedback loop Output -4 (N/O) Output -4 (N/O) Output - (N/C) Key 0 max. 500 ms max. 0 ms Response time LED details () Supply voltage A-A, S-S. LED indicates that buttons S and S are correctly connected. Feedback loop Y-Y. K-K status (N/O safety outputs closed). page 8790-EN/ 7

Connections (continued) Preventa safety modules type Module associated with a two-hand control station and a foot switch L (+) S4 F 0 S S4 selector switch: 0 = stop = control station = foot switch S-S: two-hand control station pushbuttons S: foot switch S S A T T T T T T A Y Y 4 4 N (-) Modules associated with two-hand control stations L (+) F S S 7 X 9 When operator is absent: replace terminal block X by X and physically remove the two-hand control station. 4 5 6 A T T T T T T 8 0 When operator is absent: replace terminal block X by X and physically remove the two-hand control station. A Y Y 4 4 X 4 5 6 7 8 9 0 S S selector switch: = operator = operator = operator and operator S-S, S-S: two-hand control station pushbuttons S S 7 X 9 4 5 6 8 0 A T T T T T T A Y Y 4 4 N (-) page 8790-EN/ 8

Connections Preventa safety modules type XPS BF XPS BF Module XPS BF associated with a two-hand control station F S XY SB ESC A S S S Y Y Logic Fault K/K K K XPS BF K K A S S S Y4 Y44 4 4 S XY SB To PLC ESC: External start conditions. Y-Y: feedback loop Functional diagram of module XPS BF Two-hand control not activated Two-hand control activated Two-hand control deactivated Mushroom head S (N/C) Mushroom head S (N/O) Mushroom head S (N/C) Mushroom head S (N/O) Feedback loop Output -4 (N/O) Output -4 (N/O) Solid-state output Y4 (fault) Solid-state output Y44 (K/K) T = 0.5 s max. T = 0.0 s max. Activated Deactivated Key LED details (XPS BF) Supply voltage A-A (fuse status). Fault signalling. K-K status (N/O safety outputs closed). page 8790-EN/ 9