FACT OPTICAL DISTRIBUTION FRAME SYSTEM

Similar documents
FIST-GPS2/3. Fiber Management Splice/Patch and Patch/Patch Shelves. Features

Ordering Guide for FIST Blue Label Racks (FIST-GR3)

FIST. Fiber Infrastructure System Technology. Generic Racks (FIST-GR2)

Ordering Guide of the Tray Patching & Splicing Shelf (FIST-GPS2)

TENIO. Advantages. Fiber Closures

on-going maintenance by less management hardware with a new sealing system to simplify training and reduce

Ordering Guide of the Tray Patching & Splicing Shelf (FIST-GPS2)

PRINTER ACCESSORIES TECHNICAL DATASHEET UNIVERSAL REEL HOLDER

TENIO. Fiber Closures

Ordering Guide of the Tray Patching & Splicing Shelf (FIST-GPS2)

OCM5 Splitters and Pass-Through Modules for CSX-3 Cabinets

PRINTER ACCESSORIES TECHNICAL DATASHEET UNIVERSAL REEL HOLDER

Rack Mounted Products

OAsys. 24 Fibre Swing Out Splicing and Patching Shelf. Rack Mounted Products. Features and Benefits. Prysmian Part Numbers: See Table on page 3

3M Fiber Distribution Units 8400 Series

TrueNet TFP Series Rack Mount Fiber Panels

Racks. RS3000 Rack. Features and Benefits. Prysmian Part Numbers: See below. Kit Contents. Additional Items Recommended. Prysmian Part Numbers

Ordering Guide of the Single-Mode Connectorized Fiber Cables (Pigtails & Jumpers) and Single-Mode Connector Mating Adapters

OAsys. SRS3000 1U Splice and Patch Shelf. Rack Mounted Products. Features and Benefits. Prysmian Part Number: See table on following pages.

Racks. IP41 RS3000 Rack RAL7038. Features and Benefits. Prysmian Part Numbers: See below. Kit Contents. Additional Items Recommended

Rack Mounted Products

FIST-GR3 ODF System Featuring Quareo Technology 2015 ORDERING GUIDE 4TH EDITION

Ordering Guide of the FOSC Splicing Trays and Storage Baskets

Fiber Management Tray (FMT) User Manual

RUFIS. Remote Radio Head (RRH) Unit Field Installation System. Ease your transition towards next generation base stations

RMG Series Rack Mount Fiber Enclosures

3M Fiber Distribution Units 8400 Series. The Network of Networks. Flexibility for. Networks. Growing

C2LINX. Ordering Guide

Product information 19" 1U UniRack2 24xLC-Duplex G.652.D, PC, ceramic, C/2 R819330

Data Sheet. Customer Distribution and Termination Enclosure OptiBox 4

FIST-GCO2-F. Flat FIST Generic Closure Organizer. Features

Product Description. Features & Benefits. Multilink Inc All Rights Reserved. Removable Seal Window Opening:

High Density LSX 288-Position Panel

NG3 High-Density Fiber Distribution Frame System Termination, Termination/Splice, VAM, and MPO Panels

BUSINESS CLASS SERVICES. COMMERCIAL ACCESS SOLUTIONS Ordering Guide

FTTX Fiber Optic Cabinet Packages Priority Electronics USA

MULTIPORT SERVICE TERMINALS (MST)

TrueNet WMG Series Wall Mount Fiber Enclosures

3 Angled Connector Housing (MC) Installation

Fibre Enlosures and Splicing

Product information 19" 1U UniRack 24xLC-Duplex OM4, PC, ceramic, Bm/3 R816749

BUDI Connectorized with FIST

Next Generation Frame Fiber Termination Block With MPO Connectors (FTB w/mpo) User Manual

FL1000 Wall-Mount Box Installation and Operation Guide

INDUSTRIAL MINI I/O CONNECTOR

Clearview Cassette. Clearview Blue

LSX Optical Distribution Frame

Rack Mounted Products

WIRELESS /// DISTRIBUTED ANTENNA SYSTEMS DISTRIBUTED ANTENNA SYSTEMS FOR WIRELESS COVERAGE AND CAPACITY

FPX Series Fiber Panels Next Generation FPL

T200 IDENT PRINTER BUDGET THERMAL TRANSFER PRINTER TECHNICAL DATASHEET

FDH Sealed Fiber Distribution Hub. Features and Benefits

Two Rack Unit (2RU) Fiber Management Tray (FMT) User Manual

LiSA ODRF (ETS) features. HUBER+SUHNER Excellence in Connectivity Solutions

REMOTE INPUT/ OUTPUT TERMINAL SYSTEM (RITS) CONNECTORS

3M SLiC Fiber Aerial Terminal Closure 530 Internal for Direct Spliced Drop Terminations. 3M External Cable Assembly Module (ECAM) 12mm Drop Entry Kit

FOSC 400 Closures and Accessories 2015 ORDERING GUIDE 1ST EDITION

Mounting Bracket for 8 in. Charles Industries Pedestal for use with 3M Fiber Dome Terminal Closure FDT 08

Siemon PON Fiber Cabling Solutions

3M Passive Optical Splitter Shelves and Modules

VERTIV VR RACK. Selection Guide

Items Dimension(WxDxH) Max.Capacity Mounting P-FDB8 181X45X207mm 8 ports & splice Pole/Wall P-FDB16 220x80x300mm 16 ports & splice Pole/Wall

T3224 PRINTER. THERMAL TRANSFER PRINTER (600dpi) TECHNICAL DATASHEET

TrueNet 1U and 2U Fiber Panel Installation and Cable Routing Instructions

FPX SERIES FIBER PANELS

TE3124 PRINTER THERMAL TRANSFER PRINTER TECHNICAL DATASHEET

MODULAR PLUGS, ACCESSORIES AND TOOLING

PRINTING RIBBONS AND INKS TECHNICAL DATASHEET

FTTX SOLUTIONS. Multiport Service Terminal (MST) and Hardened Drop Cables BENEFITS:

Description and Assembly Instructions

3M Fiber Dome Terminal Closures FDTC 08M and FDTC 08S External Drop Termination

FIBRE OPTIC ENCLOSURES SYDNEY MELBOURNE BRISBANE PERTH JCSTECH.COM.AU

Pretium Rack-mountable 1U Housing Hardware

Spec Sheet. TrueNet TFP Series Rack Mount Fiber Panels. Features: Applications and Benefits:

PRODUCT CATALOGUE. Rev A HEXATRONIC.SE

FullAXS CONNECTOR SEALING & CABLE ASSEMBLY

FTTX Solutions Passive Optical Splitter Modules. 7th Edition

2.17 3M 19" Patchpanels

FP front panel. Features: Modular design 1U or 2U version Connector panels or brush entry

TELECOM SOLUTIONS SOLUTIONS CONNECTIVITY CATALOGUE INNOVATIVE FIBRE OPTIC SOLUTIONS

AEROSPACE, DEFENSE & MARINE /// MC801 FIBER OPTIC CONNECTORS

AMP-LATCH RIBBON CABLE INTERCONNECT SOLUTIONS

FIBEROPTIC TERMINATION&CASETTE

The OpDAT Wall Distributor is a distributor for universal use in floor cabling or as a building distribution point in the equipment room.

Wall-Mountable Connector Housings (WCH)

Rack Mount Interconnect Center (RIC3)

AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System

Technical Description

Fiber Management Tray 2 Rack Unit (2 RU) Style FMT-G Series

Termination Box MOTB-001

Indoor Protected Entrance Terminal 4588 Series

FLAT FLEXIBLE CABLE (FFC) CONNECTORS

Aerial Façade. Cabinets and borders. Butt and Sleeves Closures for manholes and handholes

Opt-X Enterprise Fiber Trunk Cables

6. Building Risers M Solutions for Medium Buildings. Description

Optical Line Splitter Installation Instructions

3M Compact Coarse Wave Division Multiplexer (CCWDM) Module Installation

Powered Fiber Cable System

T600 TACHOMETER MultiTasker - a measurement & monitoring instrument with 2 frequency and 1 analog inputs

C5C Cross-Connect System

Transcription:

FACT OPTICAL DISTRIBUTION FRAME SYSTEM Fiber Connectivity for Splice/ Patch and Patch/Patch For almost 30 years, TE Connectivity has led the industry with solutions such as FIST fiber management system, providing a system of fiber management from the central office through the customer premises. Now, TE continues that leadership with the introduction of the FACT ODF system, enabling faster and easier installation in a high density environment. The toolless system approach and the high level of modularity guarantee an easy migration path towards new connectivity platforms and expansion of existing central office sites. FACT modules support full patch and/or splice-patch functions within a rack environment. Trays within the element can be configured with adapters, splicing and passive optical components. Trays are staggered for easy fiber routing and access to connectors. Currently available, the FACT standard version integrates into a current partially or non-equipped FIST-GR2/3 frame or lineup. FEATURES Patching, using patch cords, connectorized breakout or intrafacility cables Splicing loose tube, non-connectorized intrafacility or breakout cables to pigtails and patching these pigtails to patch cords Supports integration of passive optical splitters and wavelength division multiplexers Various connector/adapter types possible Enhanced modularity created by stacking four elements together in a 3HU grouping Full patching capability on the elements and between elements in one module and across modules Use of connectorized cables allows repair of pigtails Easy identification of each fiber Kits available to attach cables at the side of the elements Full wrap-around solution accessible from the front to guide fibers and pigtail Can be installed in TE FIST racks and other 19-inch or metric (ETSI) rack sizes FACT elements and modules are shipped with the maximum number of trays already installed. BENEFITS OF ADVANCED ELEMENT PATCHING Easy: Full front access and non-moving fiber during element manipulation Fast: Toolless scalable system Clean: Both sides easily accessible for cleaning adapters Safe: Laser light oriented perpendicularly to the operator Accessible: Full front access at both sides of connection Visible: Patch cords do not hamper access or visibility of ports Secure: Because of their position in the trays, connectors are better protected than in some front facing patch shelves Manipulation of patch cords does not cause transient losses Reconnection to other positions in the same tray or shelf does not result in uncontrolled overlengths Bend controls guide and protect the pigtail cable and ensure controlled cable routing

Fiber Connectivity Elements for Splice/Patch and Patch/Patch DIMENSIONS OF FACT ELEMENTS Height in mm Width in mm Depth in mm standard/ small-form-factor adapters Standard (retrofit in FIST-GR3 frames) 30.95 524 283.1 12/24 ORDERING FACT MODULES Element colors: Orange (RAL 2011) and grey (RAL 7035) Elements are always ordered fully loaded For a list of accessories and consumables, please refer to the FACT accessories ordering guide Elements can be configured with single adapters or with adapter packs Cable construction (the number of fibers per cable) will determine the number and combination of elements to be ordered Depending on the cable s fiber count, at least one of the total number required to support that number of fibers must be releasable (equipped with a latch that allows a set/combination of elements to be removed from the rack Elements support most common cable constructions (loose tube, central core, IFC) Four (4) elements equal 3HU (125mm) Cable fiber count SC connectors/adapters LC connectors/adapters 24 SC connectors per element (1) 48 LC connectors per element (2) FCEs Height Units FCEs Height Units 24 1 Fits 1HU 1* Fits 1HU 48 2 Fits 2HU 1 Fits 1HU 72 3 Fits 3HU 2** Fits 2HU 96 4 Fits 3HU 2 Fits 2HU 144 6 Fits 4HU 3 Fits 3HU 192 8 Fits 5HU 4 Fits 3HU 288 - - 8 Fits 6HU 1 SC connectors with up to 2.4mm patch cords 2 LC connectors with up to 1.8mm patch cords * Element ships with 2 trays, each with 12 LC adapters (24 LC connections); 48 LC connections in total. Unused tray may be discarded or used for future growth. ** Each elements ship with 2 trays, each with 12 LC adapters (24 LC connections). 96 LC connections in total. Unused trays may be discarded or used for future growth. PAGE 2

Standard Size for FIST-GR Retrofit FACT STANDARD SIZE Ordered for retrofit into a current partially or non-equipped FIST-GR2/3 frame or lineup PAGE 3

Standard Size for FIST-GR Retrofit ORDERING INFORMATION FACT Module - Standard Size Patch only. No Cable. Standard kit includes: Trumpets Hook and loop fasteners Back plates ordered separately. Size of back plate defined by port/fiber count. See page 7 for information. FACT - S - AA - 0 NN Port count 024 24-position 048 48-position 072 72-position 096 96-position 144 144-position 192 192-position 288 288-position (LC only) Adapter type Single adapters S1 SC/UPC S2 SC/APC 8 L1 LC/UPC L2 LC/APC E9 E2000 8 Adapter packs PS1 SC/UPC PS2 SC/APC 8 PL1 PL2 LC/UPC LC/APC PAGE 4

Standard Size for FIST-GR Retrofit ORDERING INFORMATION FACT Module - Standard Size Splice/Patch. No Cable. Standard kit includes: Trumpets Hook and loop fasteners Back plates ordered separately. Size of back plate defined by port/fiber count. See page 7 for information. Cable attachment kits ordered separately. Attachment size defined by fiber size and type. See pages 8 and 9 for information. FACT - S - - 0 NN Port count 024 24-position 048 48-position 072 72-position 096 96-position 144 144-position 192 192-position 288 288-position (LC only) Adapter type Single adapters Standard (Grade c) Superior (Grade B) SC/UPC S1 - SC/APC 8 S2 SG SC/APC 9 S3 - LC/UPC L1 LF LC/APC L2 LG E2000 8 E9 - Adapter packs Tray option Standard adapters Right of shelf (1) Left of shelf (2) Adapters; SMOUV splice protector; no fiber (3) AE EA Adapters; ANT splice holder (4) ; no fiber AF FA Connector/adapters; with pigtails and SMOUV splice protector (3) ; fiber from adapters to splice holder, ready for incoming cable Connector/adapters; with pigtails and ANT splice holder (4) ; fiber from adapters to splice holder, ready for incoming cable AI AJ 1 Patch cords leave shelf to right 2 Patch cords leave shelf to left 3 45 mm SMOUV heat shrink splice protector is included 4 ANT splice holder ONLY; splice protectors must be ordered separately IA JA SC/UPC PS1 - SC/APC 8 PS2 PSG SC/APC 9 PS3 - LC/UPC PL1 PLF LC/APC PL2 PLG PAGE 5

Standard Size for FIST-GR Retrofit ORDERING INFORMATION FACT Modules - Standard Size Splice/Patch. Pre-cabled. Standard kit includes: Trumpets (pre-installed) Cable attachments (pre-installed) Hook and loop fasteners Back plates ordered separately. Size of back plate defined by port/fiber count. See page 7 for information. FACT - S - - Port count 024 24-position 048 48-position 072 72-position 096 96-position 144 144-position 192 192-position 288 288-position (LC only) Adapter type Single adapters Standard (Grade c) Superior (Grade B) SC/UPC S1 - SC/APC 8 S2 SG Cable type Intrafacility cable IA 12-fiber (no strength member) IF 48-fiber (with strength member) Micro-distribution breakout cable MA 8-fiber MB 12-fiber Loose tube indoor cable OG 72-fiber OH 96-fiber OI 144-fiber Length in meters 0-99 SC/APC 9 S3 - LC/UPC L1 LF LC/APC L2 LG E2000 8 E9 - Adapter packs SC/UPC PS1 - SC/APC 8 PS2 PSG SC/APC 9 PS3 - LC/UPC PL1 PLF LC/APC PL2 PLG Tray option Standard adapters Right of shelf (1) Left of shelf (2) Adapters; SMOUV splice protector; no fiber (3) AE EA Adapters; ANT splice holder (4) ; no fiber AF FA 1 Patch cords leave shelf to right 2 Patch cords leave shelf to left 3 45 mm SMOUV heat shrink splice protector is included 4 ANT splice holder ONLY; splice protectors must be ordered separately PAGE 6

Standard Size for FIST-GR Retrofit - Back Plates BACK PLATES FOR STANDARD SIZE FACT ELEMENTS AND MODULES Description Back plates Allow placement of FACT STANDARD size elements or modules in FIST-GR3 Fits 1 HU; mounts 1 standard size FACT element (2) cage nuts (2) bolts (2) washers (2) single U-shape FACT brackets FACT-BPLATE-1E-S Fits 2 HU; mounts 2 standard size FACT elements (4) cage nuts (4) bolts (4) washers (2) double U-shape FACT brackets Equal to 3 HU; mounts 4 standard size FACT elements (1 FACT module) (4) cage nuts (4) bolts (4) washers (4) double U-shape FACT brackets FACT-BPLATE-2E-S FACT-BPLATE-4E-S Cable fiber count SC connectors/adapters 24 SC connectors per element Height Units FCEs back plates LC connectors/adapters 48 LC connectors per element Height Units FCEs back plates 24 1 Fits 1HU (1) 1E-S 1 Fits 1HU (1) 1E-S 48 2 Fits 2HU (1) 2E-S 1 Fits 1HU (1) 1E-S 72 3 Fits 3HU (1) 1E-S + (1) 2E-S 2 Fits 2HU (1) 2E-S 96 4 Fits 3HU (1) 4E-S 2 Fits 2HU (1) 2E-S 144 6 Fits 4HU (1) 2E-S + (1) 4E-S 3 Fits 3HU (1) 1E-S + (1) 2E-S 192 8 Fits 5HU (2) 4E-S 4 Fits 3HU (1) 4E-S 288 - - - 8 Fits 6HU (2) 4E-S PAGE 7

Standard Size for FIST-GR Retrofit - Cable attachment kits CABLE ATTACHMENT KITS FOR STANDARD SIZE FACT ELEMENTS AND MODULES Description Cable bracket kits 250 μ cable For cable diameters up to 8.5mm* Occupies 1 FACT element (2) single cable attachment sub-assemblies (2) strength members (2) 250 μ routing components (2) plastic covers (3) 250 μ overtubing (30 cm) (3) overtubing fixation devices (2) spiral tube protection pieces (2) tie wraps (1) foam strips (15 cm) FACT-CACC-SMALL-PF For cable diameters from 8.5mm to 15mm** Occupies 1 FACT element (1) single cable attachment sub-assembly (1) strength member (2) 250 μ routing components (1) plastic cover (2) 250 μ overtubing (30 cm) (2) spiral tube protection pieces (2) tie wraps (4) foam strips (15 cm) FACT-CACC-MEDIUM-PF Cable bracket kits 900 μ cable For cable diameters up to 8.5mm* Occupies 1 FACT element (2) single cable attachment sub-assemblies (2) strength members (2) 900 μ routing components (2) Plastic covers (2) Fiber fixation devices (2) spiral tube protection pieces (2) tie wraps (1) foam strips (15 cm) FACT-CACC-SMALL-SF For cable diameters from 8.5mm to 15mm** Occupies 1 FACT element (4) single cable attachment sub-assemblies (8) strength members (4) 900 μ routing components (4) plastic covers (8) fiber fixation devices (8) spiral tube protection pieces (8) tie wraps (4) foam strips (15 cm) FACT-CACC-MEDIUM-SF * Note: Cable should be flexible and allow minimum bend radius of 75 mm. Cable attachment fits corrugated tube 10mm outer diameter ** Note: Cable should be flexible and allow minimum bend radius of 75 mm. Cable attachment fits corrugated tube 16mm outer diameter PAGE 8

Standard Size for FIST-GR Retrofit - Cable attachment kits Cable fiber count SC connectors/adapters 24 SC connectors per element cable Height Units FCEs attachments LC connectors/adapters 48 LC connectors per element cable Height Units FCEs attachments SMALL MEDIUM SMALL MEDIUM 24 1 Fits 1HU 2 1 1 Fits 1HU 2 1 48 2 Fits 2HU 4 2 1 Fits 1HU 2 1 72 3 Fits 3HU 6 3 2 Fits 2HU 4 2 96 4 Fits 3HU 8 4 2 Fits 2HU 4 2 144 6 Fits 4HU 12 6 3 Fits 3HU 6 3 192 8 Fits 5HU 16 8 4 Fits 3HU 8 4 288 - - - - 8 Fits 6HU 16 8 For more technical options and order quantity information, please consult the product ordering guide or your local sales representative. te.com FACT, FIST, SMOUV, TE Connectivity, TE Connectivity (logo) and Every Connection Counts are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 2014 TE Connectivity Ltd. family of companies All Rights Reserved. 319161.1 02/15 Revision PRODUCT SHEET TE Connectivity Broadband Network Solutions - EMEA Diestsesteenweg 692 3010 Kessel-Lo, Belgium Tel 32-16 351 011 www.te.com/bns Tyco Electronics Raychem bvba, a TE connectivity company.