Dell MD1280 Storage Enclosure Getting Started Guide

Similar documents
Dell EMC Storage MD1280 Enclosure Owner's Manual

Dell SC7020 Storage Controller Getting Started Guide

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Dell SC460 Expansion Enclosure Getting Started Guide

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

Dell Storage Center. Owner's Manual. SC180 Expansion Enclosure. Regulatory Model: E11J Regulatory Type: E11J001

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

SCv360 Expansion Enclosure

Dell Storage MD1400 and MD1420 Enclosures Getting Started Guide

Dell PowerVault MD3400/3420/3800i/3820i/3800f/ 3820f Storage Arrays Getting Started Guide

Dell PowerVault MD3460/3860i/3860f Storage Arrays Getting Started Guide

Dell PowerEdge T420 Getting Started Guide

SATADOM. for Dell PowerEdge R630, R730, and R730xd systems

Dell PowerEdge R720 and R720xd Getting Started Guide

Dell PowerEdge T620 Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Owner s Manual

Dell SC7020 and SC7020F Storage Systems Owner s Manual

Dell PowerVault MD3400/3420/3800i/3820i/ 3800f/3820f Storage Arrays Getting Started Guide

StorNext M440 Site Planning Guide

Dell Storage MD1400 Enclosures Hardware Owner's Manual

JanusRAID SA-6692J Hardware User Manual

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Dell Networking S4810 Open Networking (ON) Getting Started Guide

Dell PowerEdge T620 Getting Started Guide

Dell EMC ME4 Series JBOD 5U84 Enclosure

Inspiron Setup and Specifications

NOTE: Use the System Setup program to view microprocessor information. For more information, see "Using the System Setup Program."

Inspiron Setup and Specifications

IndigoVision Enterprise NVR-AS 4000 G3 Windows Appliance. Quick Start Guide

Dell OptiPlex All-in-One. Stand Installation Guide

Dell PowerEdge M905, M805, M605, and M600. Getting Started With Your System

Installation Job Aid for VSP 4450GTX-HT- PWR+

Inspiron Setup and Specifications

Inspiron Setup and Specifications

E-Series Site Preparation Guide

Inspiron 13. Setup and Specifications Series 2-in-1. Computer Model: Inspiron Regulatory Model: P69G Regulatory Type: P69G001

Inspiron Setup and Specifications. 2-in-1. Computer Model: Inspiron Regulatory Model: P58F Regulatory Type: P58F001

Inspiron 15. Setup and Specifications Series 2-in-1. Computer Model: Inspiron Regulatory Model: P58F Regulatory Type: P58F001

Alienware Area-51 R5 Setup and Specifications

Inspiron 3268 Setup and Specifications

Dell Vostro 460. About Warnings. Setup and Features Information

Inspiron Setup and Specifications. Computer Model: Inspiron Regulatory Model: P66F Regulatory Type: P66F001

SGI InfiniteStorage 120

Artico NAS Storage Appliance Site Planning Guide

Inspiron Setup and Specifications

Installation Job Aid for VSP 4850GTS

Dell DL1300 Appliance Interoperability Guide

Inspiron Setup and Specifications

1 Getting Started Installing & Configuring

Dell Vostro 320 Setup and Features Information Tech Sheet

Installing the IPS 4345 and IPS 4360

Inspiron Setup and Specifications. Computer Model: Inspiron Regulatory Model: P66F Regulatory Type: P66F001Msystems

IndigoVision Enterprise NVR-AS 4000 Linux Appliance. Quick Start Guide

Inspiron Setup and Specifications

DNS-2608 Enterprise JBOD Enclosure User Manual

Msystems Ltd. Inspiron 3668 Setup and Specifications. Computer Model: Inspiron 3668 Regulatory Model: D19M Regulatory Type: D19M003

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Dell Precision Workstation T7500/T7500n Setup and Features Information

Alienware Area-51 R4 Setup and Specifications

Inspiron Setup and Specifications

Alienware 13 R3 Setup and Specifications

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

XPS 27 Setup and Specifications

Inspiron Setup and Specifications

easyraid Q24P2-U4R4 Hardware Manual

XPS 15 Setup and Specifications

Dell EMC PowerVault MD3060e Storage Enclosure. Deployment Guide

1U Device Expansion Unit Configuration Guide

Inspiron in-1 Setup and Specifications

Inspiron Series. Views. Specifications

Dell EMC PowerVault MD3460 Storage Arrays

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003

Dell XPS 14z Owner s Manual

Installing the Cisco MDS 9020 Fabric Switch

Dell Networking S4100-ON Series. Set-Up Guide

Inspiron Setup and Specifications

Inspiron Gaming Desktop Setup and Specifications

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

Site Survey 4U60 Storage Enclosure G460-J-12 November ET0165 Revision 1.1. Long Live Data

Inspiron All-in-One Setup and Specifications

Dell Thunderbolt Dock TB15 User Guide

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

Inspiron All-in-One Setup and Specifications

XPS 13 Convertible Setup and Specifications

Before you begin. Installation and Setup Instructions for E-Series 60-Drive Trays. Unpack & Prepare. Install Hardware. Connect Hardware.

Dell Latitude E5410/E5510

FUSION RX1600RAID. Rackmount 16-Drive SATA Storage System with Internal SAS Expanders. Drive Enclosure User s Guide

Inspiron Setup and Specifications Series. Computer Model: Inspiron 5448 Regulatory Model: (P49G) Regulatory Type: (P49G001)

Dell Latitude E6220. Setup And Features Information. About Warnings. Front And Back View

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014

Dell PowerEdge FC640. Technical Specifications. Regulatory Model: E02B Series Regulatory Type: E02B005

Dell EMC BOSS-S1 (Boot Optimized Server Storage) User's Guide

Inspiron Setup and Specifications

Sivy SA-4327S Hardware User Manual

Inspiron Setup and Specifications

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Dell Inspiron 580: Comprehensive Specifications

Transcription:

Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies. 2015-03 Rev. A01

Installation and configuration 1 WARNING: Before completing the following tasks, review the safety instructions that came with the system. NOTE: The system is intended for restricted access location. Installation safety precautions When mounting an enclosure in a rack, you must follow the safety requirements listed here. The rack construction must be capable of supporting the total weight of the installed enclosure(s) and the design must incorporate stabilizing features suitable to prevent the rack tipping, or being pushed over during installation or in normal use. When loading a rack with enclosures, load the enclosures into the rack from bottom and remove the enclosures from the top. To avoid danger of a rack toppling over, do not slide more than one enclosure out of the rack at a time. The system must be operated with low pressure rear exhaust installation [back pressure created by rack doors and obstacles not to exceed 5 Pascals (0.5 mm water gauge)]. The rack design must consider the maximum operating ambient temperature for the unit, which is 35 C. The rack must have a safe electrical distribution system. It must provide over-current protection for the unit and must not be overloaded by the total number of units installed in the rack. When resolving these issues, consider the electrical power consumption rating displayed on the name plate. The electrical distribution system must provide a reliable ground for each unit in the rack. 3

NOTE: Heavy weight warning. A fully configured MD1280 enclosure weighs up to 103.7 kg (287.5 lbs). An unpopulated enclosure weighs 64 kg (141 lb). Use appropriate lifting methods. High temperature warning. The operating temperature inside the enclosure can reach up to 60 C (140 F). Be careful when opening drive drawers and removing carriers. Electrical disconnection warning. Indicates that all electrical supply connections to the enclosure should be disconnected before proceeding. Unpacking the system NOTE: Unpacking, installing, and deploying your Dell Storage must be carried out only by a certified service technician. Before you begin, make sure the site where you intend to set up and use the Dell Storage has the following: 208 V power from an independent source or a rack power distribution unit with a UPS (110 V power will not work.). A 5U space in the lower 20U of the rack. If planning to install above the 20U mark, a customerprovided mechanical lift must be made available. Installation overview The installation process includes the following general tasks. CAUTION: If installed in a closed-or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, install the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. For more information, see the Technical Specifications section in this document. 1. Assemble the rails following the safety instructions and the rack installation instructions provided with your system. 2. Unpack the enclosure. WARNING: Two people using lift straps are required to avoid injury. 3. Install the enclosures into the rack. Always load the rack from the bottom for weight stability. If you have fewer than the maximum number of enclosures, you can allow room for expansion. 4

WARNING: If installing above the lower 20U of a rack, a customer-provided mechanical lift must be used to avoid injury. 4. Insert each disk drive in carrier (DDIC) into the enclosure one at a time. Protect the hard drive from static discharge. Handle DDICs by the edges of the frame. CAUTION: If the enclosure system operates for too long (depending on altitude) with drive drawers open, the enclosure can overheat, causing power failure and data loss. Such use may invalidate the warranty. 5. Close the drive drawers after adding all DDICs. Figure 1. Installing enclosure in a rack 1. Drawer release (2) One on each side of drawer. Releases the open-drawer locks. a. Pull and hold both drive drawers releases, and then slightly push the drawers inside. b. Release and push the drive drawers in until it clicks into place. WARNING: After releasing the open-drawer locks, move hands away from the slides before pushing the drawer in to avoid injury. 5

Connecting the power cables Figure 2. Connecting the power cables Ensure that the power switch is OFF before connecting the power cables. CAUTION: Be careful when closing the rear rack door to ensure that power cords have adequate space as some racks might not be sufficiently deep. 6

Securing the power cables Figure 3. Securing the power cables 1. Secure the power cables firmly to the bracket using the clip provided. 2. Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU). Location of power switches Figure 4. Location of power switches 7

Other information you may need 2 WARNING: See the safety and regulatory information that shipped with your system. Warranty information may be included within this document or as a separate document. The rack documentation included with your rack solution describes the process of installing your system into a rack. The Service Guide provides information about enclosure service and maintenance. This document is available online at dell.com/support/home. The Administrators Guide provides information about how to configure, manage, and update your MD1280 Storage Enclosure. This document is available online at dell.com/support/home. 8

Technical specifications 4 Drives SAS hard drives Up to 84 3.5-inch SAS hot-swappable hard drives (6.0 Gbps or 12.0 Gbps) Storage Bridge Bay (SBB) Modules SBBs Two hot-swappable EMM I/O modules Connectivity Configurations Various server-attached configuration including but not limited to 168 hard drives in redudant-path enclosure chains. Servers can support up to six enclosure chains. Redundant Array of Independent Disks (RAID) Controller Management Various server-based RAID controller or SAS HBA. RAID management by using Dell Storage System Manager version 6.4 or later. Back-Plane Board Connectors 84 SAS hard-drive connectors Two sets of SBB connectors Five cooling fan module connectors Two power supply unit (PSU) connectors Back-Panel Connectors (per SBB) SAS connectors Asymmetric SAS Cabling for connection to the controller and for expansion to an additional enclosure Support Mini-SAS HD to Mini-SAS cable universally keyed for the following lengths that are currently supported: Controller to MD1280: 0.5 m 2 m 9

Back-Panel Connectors (per SBB) 3 m 5 m MD1280 to MD1280: 0.6 m 2 m 4 m 6 m NOTE: SAS connectors are SFF-8086/ SFF-8088-compliant. LED Indicators Front panel One two-digit LCD indicator for Unit ID, error code, and unit location identifier One two-color LED indicator for power status One single-color LED indicator for module fault status (enclosure as a whole) One single-color LED indicator for logical fault status (drive, HBA, RAID controller, and so on) One single-color LED indicator for drive drawer 1 fault status One single-color LED indicator for drive drawer 2 fault status Drive drawer One single-color LED indicator for sideplane card and power status One single-color LED indicator for drive drawer fault status One single-color LED indicator for logical fault status One single-color LED indicator for cable fault status Six single-color LED indicators for data transfer status Disk Drive In Carrier (DDIC) One single-color LED for hard drive fault status 6 Gb SAS IO module 14 one-color LED status indicators, four each for the three SAS ports, and two for the module status Cooling module One single-color LED indicator for module status One single-color LED indicator for battery fault status (not currently used) One single-color LED indicator for fan fault status Power Supply Unit (PSU) One single-color LED indicator for PSU fault status 10

LED Indicators One single-color LED indicator for AC power fault status One single-color LED indicator for power status Power Supply Units AC PSU (per PSU) Watt 2.8 kw Voltage 200 240 VAC (8.6 A 4.3 A) Heat dissipation Maximum inrush current 191 147 W Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55 A for each PSU for 10 ms or less Available Hard Drive Power (Per Slot) Supported hard drive power consumption (continuous) Up to 1.16 A at +5 V Up to 1.6 A at +12 V IO Card Power (Per Slot) Maximum power consumed by IO Card Maximum available power Maximum available power 11 W at +12 V 100 W at +12 V 1 W at +5 V (standby) Physical Height Width Depth (front mounting bracket to rear surface) Depth (front surface to rear surface) Full Weight (maximum configuration) Shipping Weight (without drives) 22.23 cm (8.75 inches) 48.26 cm (19 inches) 91.5 cm (36 inches) 96 cm (38 inches) 130.7 kg (287.5 lb) 62 kg (137 lb) 11

Environmental NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. Temperature Operating 5 to 35 C (41 to 95 F) with a maximum temperature gradation of 10 C per hour NOTE: Maximum 35 C up to 2134 m (7000 ft), derate to 30 C for 2134 m to 3000 m (7000 ft to 10,000 ft). Storage 40 to 70 C ( 40 to 158 F) with a maximum temperature gradation of 20 C an hour Relative humidity Operating Storage 20 percent to 80 percent (noncondensing) with a maximum humidity gradation of 10 percent an hour 5 percent to 100 percent (noncondensing) Maximum vibration Operating Storage 0.21 g at 5 500 Hz for 15 min 1.04 g at 2 200 Hz for 15 min Maximum shock Operating Half-sine shock 5 g +/- 5 percent with a pulse duration of 10 ms +/- 10 percent in operational orientations only Storage Z-axis: 30 g 10 ms half-sine Horizontal (X) axis and vertical (Y) axis: 20 g 10 ms half-sine Altitude Operating 30.5 to 3000 m ( 100 to 10,000 ft) NOTE: Maximum 35 C up to 2134 m (7000 ft), derate to 30 C for 2134 m to 3000 m (7000 ft to 10,000 ft). Storage 300 m to 12,192 m ( 1000 ft to 40,000 ft) Airborne Contaminant Level 12

Environmental Class G2 or lower as defined by ISA-S71.04-1985 13

Contacting Dell 5 Dell provides several online and telephone-based support and service options. If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer-service issues: 1. Go to dell.com/support. 2. Select your country from the drop-down menu on the bottom right corner of the page. 3. For customized support: a. Enter your system Service Tag in the Enter your Service Tag field. b. Click Submit. The support page that lists the various support categories is displayed. 4. For general support: a. Select your product category. b. Select your product segment. c. Select your product. The support page that lists the various support categories is displayed. 14