MODEL NUMBER: SU6000RT4UTF. Highlights

SmartOnline 208/240V 6kVA 5.4kW Double- Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9, Bypass Switch, L6-30R & L6-20R

SmartOnline V 12kVA 10.8kW Double-Conversion UPS, N+1, 8U, Extended Run, Network Card Slot, USB, DB9, Bypass, Hardwire

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch

SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch

MODEL NUMBER: SU6000RT4UHVHW. Highlights. Description. Package Includes

SmartOnline 208/240V 10kVA 9kW Double- Conversion UPS, 6U, Extended Run, Network Card Slot, USB, DB9, Bypass Switch, NEMA

SmartOnline 208/240 & 120V 8kVA 5.6kW Double- Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9, Bypass Switch

Model #: SU5000RT4UHV

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

Model #: SU5000RT4UTF

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

SmartOnline 240 & 120V 20kVA 18kW Double- Conversion UPS in 25U enclosure, Pre-installed Network Card, USB, DB9, Bypass, Hardwire

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial

SmartOnline 120V 3kVA 2.4kW Double- Conversion UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

Model #: SU6000RT4UHVG

SmartOnline 120V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, Network Card Options, LCD display, USB, DB9 Serial

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, LCD, USB, DB9 Serial

SmartOnline 120V 1.5kVA 1.35kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Oversize Internal Batteries, Network Card Slot, LCD, USB, DB9

SmartOnline 120V 2.2kVA 1.6kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

SmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Hardwire

SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets

SmartOnline 120V 2.2kVA 1.6kW Double- Conversion UPS, Tower, Extended Run, Network Card Options, USB, DB9

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

SmartOnline 208/240V 6kVA On-Line UPS Double Conversion, 5.4kW, 4U, Network Card Option, TAA Compliant

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

SmartOnline V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

SmartPro 120V 3kVA 2.88kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

SmartPro 230V 3kVA 2.7kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

SmartPro 208V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U Rack/Tower, Network Card Options, USB, DB9 Serial

SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, Tower, Extended Run, Network Card Options, LCD, USB, DB9

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9

SmartOnline 120V 2.2kVA 1.8kW Double- Conversion UPS, Tower, Extended Run, Network Management Card Slot, LCD, USB, DB9

SmartOnline 120V 2.2kVA 1.8kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, WEBCARDLX Network Interface, ENERGY STAR

TAA SmartPro 208/120V 5kVA 4kW Line- Interactive Sine Wave UPS, 6U, Extended Run, Network Card Options, USB, DB9

SmartOnline 208/230V 1kVA 900W Double- Conversion UPS, 2U, Extended Run, SNMP Card Option, LCD, USB, DB9, ENERGY STAR

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, SNMPWEBCARD Option, LCD Display, USB, DB9 Serial

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SmartOnline 230V 2kVA 1800W On-Line Double- Conversion UPS, Tower, Extended Run, Network Card Options, LCD, USB, DB9

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

SmartPro 120V 700VA 450W Line-Interactive Sine Wave UPS, Tower, 120 or 230V input, Network Card Options, USB, DB9

SmartOnline 120V 2.2kVA TAA-Compliant UPS On-Line Double Conversion, 1.8kW, 2U, Network Card Option

TAA SmartPro 120V 1.5kVA 1.35kW Line- Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

MODEL NUMBER: SMART3000RMXLN. Highlights. Package Includes. Description

SmartOnline 6kVA On-Line Double-Conversion UPS, 6U Rack/Tower, V Hardwire output

SmartPro 120V 2.2kVA 1.6kW Line-Interactive UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

SmartOnline 208/230V 2.2kVA 1.98kW Double- Conversion UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9, ENERGY STAR

SmartPro 120V 1kVA 900W Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, 8 Outlets

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack, USB, DB9 Serial, LCD

SmartPro 120V 1kVA 650W Line Interactive Sine Wave UPS, Tower, USB, DB9 Serial

SmartPro 120V 1.5kVA 1.44kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, USB, 8 Outlets

OmniSmart LCD 120V 900VA 475W Line- Interactive UPS, Tower, LCD display, USB port

Smart Pro line interactive UPS System - NAFTA assembled version of SMART2200NET

BC Pro 120V 1400VA 940W Standby UPS, Tower, USB port, 6 Outlets

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower, Extended Run, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, WEBCARDLX Network Interface, LCD, USB, 8 Outlets

SmartPro 1.5kVA 1000W Line Interactive Sine Wave UPS, 2U Rack/Tower, LCD, USB, RS232, EPO, 120V

SmartOnline Hot-Swappable Modular UPS System On-line, double-conversion protection for mission critical applications

SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

SmartPro 230V 2.2kVA 1.6kW Line-Interactive UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 230V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

OmniVS 120V 1500VA 940W Line-Interactive UPS, Tower, USB port

OmniSmart LCD 120V 700VA 420W Line- Interactive UPS, Tower, LCD display, USB port

TAA-Compliant SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartPro 1kVA 800W Line Interactive Sine Wave UPS, SNMPWEBCARD option, 1U Rackmount, USB, RS232, EPO, 120V

BC Personal 120V 450VA 280W Standby UPS, Tower, USB port, 3 Outlets

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SmartPro 120V 750VA 500W Line-Interactive Sine Wave UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 230V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, Extended Run, 2U Rack/Tower, LCD Display, USB, DB9 Serial

SmartOnline V 1kVA 700W On-Line Double-Conversion UPS, Tower, C14 inlet, DB9 Serial

OmniSmart 120V 1400VA 940W Line-Interactive UPS, Tower, USB port

OmniSmart LCD 120V 650VA 350W Line- Interactive UPS, Tower, LCD display, USB port

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

OmniVS 120V 1500VA 940W Line-Interactive UPS, Extended Run, Tower, USB port

SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

POS Series 120V 50/60Hz 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection

OmniSmart 120V 500VA 300W Line-Interactive UPS, Tower, USB port

AVR Series 120V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port

OmniSmart LCD 120V 50/60Hz 1500VA 810W Line-Interactive UPS, Tower, LCD display, USB port, Energy Star

OmniSmart 120V 700VA 450W Line-Interactive UPS, Tower USB port, DB9 Serial

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

OmniSmart 1500VA 2U Rack/Tower Line-Interactive 120V UPS with LCD display and USB port

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port

Transcription:

SmartOnline 208 & 120V 5kVA 4.5kW Double- Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial MODEL NUMBER: SU5000RT4UTF Highlights 5kVA / 5000VA / 4500 watt online double-conversion UPS; 0.9 power factor 208/120V 60Hz output; high efficiency economy mode option 6U Rack/Tower compatible; Hot swappable battery modules USB, RS232 & EPO ports; Slot for network management card options Front panel LEDs with detailed LCD monitoring and control screen Expandable runtime with optional external battery packs Description Tripp Lite SU5000RT4UTF 5000VA / 5kVA / 4500 watt on-line, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 6U rack/tower configuration. Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. 4U UPS power module with internal batteries and 2U step-down transformer installs in a total of 6 rack spaces (6U) with a maximum installed depth of only 20.75 in. / 52.7 cm. Maintains full-time sine wave output within 2% of 208 and 120V nominal at 60Hz during brownouts as low 100V and overvoltages as high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs. Network-grade AC surge and noise suppression. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional communications card accessories available. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. PowerAlert monitoring software, available via free download, offers detailed site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted. Supports Emergency Power Off (EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations. LED / LCD display panel rotates for viewing in rackmount or tower configurations. L6-30P input, plus 2 L6-30R, 2 L6-20R and 12 5-15/20R outlets. External battery packs are field replaceable and hot swappable. $250,000 connected equipment NEMA L6-30P input (3 wire); L6-30R, L6-20R & 5-15/20R outputs Package Includes SU5000RT4UHV UPS Power Module SU5000XFMRT2U Stepdown Transformer 4 Post Rackmount Installation Rails USB, DB9 and EPO cables 1 / 7

insurance; Features Tripp Lite SU5000RT4UTF 5000VA / 5kVA / 4500 watt on-line, double-conversion UPS system in a 6U rack/tower configuration (4U UPS power module with internal batteries + 2U step-down transformer) Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions L6-30P input plug, plus 2 L6-30R, 2 L6-20R and 12 5-15/20R outlets Included rail kits support rackmount installation of both included modules in 4 post racks Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (2 required for SU5000RT4UTF) Optional 2-9USTAND supports upright tower placement (1 required for SU5000RT4UTF) Maximum installed rack depth of only 20.75 in. / 52.7 cm Maintains full-time sine wave output within 2% of 208V & 120V at 60Hz nominal in double conversion mode Corrects brownouts to 156V at full load (100V at 50% load or less) Corrects overvoltages to 290V at full load (300V at 90% load or less) Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs Network-grade AC surge and noise suppression Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot interfaces UPS card slot supports one card-based network interface options Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module) HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control options to support advanced UPS settings and configurations LED/LCD display panel rotates for viewing in rackmount or tower configurations Supports Emergency Power Off (EPO) via built-in interface 2 / 7

Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement External battery packs are field replaceable and hot swappable Intelligent battery management system with temperature-compensated charging extends battery life Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual) $250,000 connected equipment insurance Specifications OUTPUT Output Volt Amp Capacity (VA) 5000 Output kva Capacity (kva) 5.0 Output Watt Capacity (Watts) 4500 Output kw Capacity (kw) 4.5 Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared Power Factor 0.9 Crest Factor 3:1 Nominal Output Voltage(s) Supported Nominal Voltage Details Frequency Compatibility Frequency Compatibility Details Output Voltage Regulation (Line Mode) Output Voltage Regulation (Economy Line Mode) Output Voltage Regulation (Battery Mode) Output Receptacles Output Circuit Breakers Output AC Waveform (AC Mode) Output AC Waveform (Battery Mode) 120V; 208V 208V default power module setting; This configuration requires the Power Module be set to 208V output voltage; Included step-down transformer supports 120V output 60 Hz Output frequency regulation +/- 0.05Hz (free running) +/- 2% +/- 10% +/- 2% (12) 5-15/20R; (2) L6-20R; (2) L6-30R High voltage 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered; Low voltage 20A breakers protect 3 5-15/20R outlets each Pure sine wave Pure Sine wave INPUT Rated input current (Maximum Load) 24A (208V) 3 / 7

Nominal Input Voltage(s) Supported UPS Input Connection Type 208V AC L6-30P UPS Input Cord Length (ft.) 10 UPS Input Cord Length (m) 3.0 Recommended Electrical Service Input Phase 30A Single-Phase BATTERY Full Load Runtime (min.) Half Load Runtime (min.) Expandable Battery Runtime External Battery Pack Compatibility 3.5 minutes (4500w) 11 minutes (2250w) Supports extended runtime with optional external battery packs BP192V1037C-1PH; BP192V12-3U; BP192V1407C-1PH; BP192V557C-1PH; BP192V787C-1PH; <a class="productlink" href="//www.tripplite.com/external-192v-2u-rackmount-battery-pack-ups-systems- BP192V5RT2U~BP192V5RT2U">BP192V5RT2U</a> (limit 1) DC System Voltage (VDC) 192 Battery Recharge Rate (Included Batteries) Internal UPS Replacement Battery Cartridge Battery Access Battery Replacement Description Expandable Runtime 6 hours from 10% to 90% (typical, full load discharge) <a class="productlink" href="//www.tripplite.com/4u-ups-replacement-192vdc-battery-cartridge-1-set-of- 16-Tripp-Lite-SmartOnline-UPS~RBC5-192">RBC5-192</a> (qty 1) Front panel battery access door Hot-swappable, user replaceable batteries Yes VOLTAGE REGULATION Voltage Regulation Description Overvoltage Correction Undervoltage Correction Online, double-conversion power conditioning 2% output voltage regulation during overvoltages to 280V (full load) / 300V (90% load or less) 2% output voltage regulation during undervoltages to 156V (full load) / 100V (50% load or less) USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display Switches Alarm Cancel Operation Audible Alarm LED Indicators Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual) 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads Alarm cancel switch Unique audible alarms for all major UPS, environmental and power conditions (see manual) 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options SURGE / NOISE SUPPRESSION UPS AC Suppression Response Time Instantaneous 4 / 7

EMI / RFI AC Noise Suppression Yes PHYSICAL Included Mounting Accessory Description Installation Form Factors Supported with Optional Accessories Optional Mounting Accessory Notes Primary Form Factor UPS Power Module Dimensions (hwd, in.) UPS Power Module Dimensions (hwd, cm) 2 sets of adjustable 4 post rack rails included 2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND) 2 sets of <a class="productlink" href="//www.tripplite.com/2-post-rack-mount-installation-kit-3u-larger-ups- Transformer-Battery-Pack-Components~2POSTRMKITHD">2POSTRMKITHD</a> required for 2 post rackmount installation of separate 4U power module and 2U transformer Rackmount 6.85 x 17.5 x 20.67 17.40 x 44.45 x 52.50 Rack Height (U Spaces) 6 Maximum Device Depth (in.) 20.75 Minimum Required Rack Depth (inches) 27 Maximum Device Depth (cm) 52.70 Minimum Required Rack Depth (cm) 68.58 UPS Power Module Weight (lbs.) 113.6 UPS Power Module Weight (kg) 51.53 Stepdown Transformer Dimensions (hwd / in.) Stepdown Transformer Dimensions (hwd / cm) 3.5 x 17.5 x 20.75 8.89 x 44.45 x 52.70 Stepdown Transformer Weight (lbs.) 76 Stepdown Transformer Weight (kg) 34.47 Included Battery Pack Dimensions (hwd / in.) Included Battery Pack Dimensions (hwd / cm) UPS Shipping Dimensions (hwd / in.) UPS Shipping Dimensions (hwd / cm) 22 x 25 x 30 55.88 x 63.50 x 76.20 Shipping Weight (lbs.) 278 Shipping Weight (kg) 126.2 Cooling Method UPS Housing Material Fan Sheet metal Maximum Device Depth (mm) 527 5 / 7

Stepdown Transformer Height (mm) 89 Stepdown Transformer Width (mm) 444 Stepdown Transformer Depth (mm) 527 Primary UPS Height (mm) 174 Primary UPS Width (mm) 444 Primary UPS Depth (mm) 525 Shipping Height (mm) 559 Shipping Width (mm) 635 Shipping Depth (mm) 762 ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius 5 to 122 F / -15 to 50 C 5% to 90% (non-condensing) AC Mode BTU / Hr. (Full Load) 1767 AC Economy Mode BTU / Hr. (Full Load) 640 Battery Mode BTU / Hr. (Full Load) 1708 AC Mode Efficiency Rating (100% Load) AC Economy Mode Efficiency Rating (100% Load) Operating Elevation (ft.) Audible Noise Operating Elevation (m) 90% 96% 0 to 6560 ft. / 0 to 2000 m 65 db at 1m front side 0-2000 m COMMUNICATIONS Communications Interface Network Management Cards Network Monitoring Port Description PowerAlert Software Communications Cable WatchDog Compatibility USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface SNMPWEBCARD; TLNETCARD; WEBCARDLX; MODBUSCARD; RELAYIOCARD Two contact closure monitoring options available - RELAYIOCARD with six configurable contact closure outputs (uses UPS card slot) and RELAYIOMINI with 3 configurable contact closure outputs (requires removal of USB port module) For local monitoring via the UPS s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert USB, DB9 serial and EPO cables included Yes LINE / BATTERY TRANSFER Transfer Time No transfer time (0 ms.) in online, double-conversion mode 6 / 7

Low Voltage Transfer to Battery Power (Setpoint) High Voltage Transfer to Battery Power (Setpoint) 156V (full load) / 100V (50% load or less, derates linearly) 280V (full load) / 300V (90% load or less) SPECIAL FEATURES Cold Start (Startup in Battery Mode During a Power Failure) High Availability UPS Features Green Energy-Saving Features Cold-start operation supported Automatic inverter bypass; Hot swappable batteries High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation CERTIFICATIONS UPS Certifications UPS Certification Details Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI); ROHS (Restriction of Hazardous Substances) IEC 61000-4-5 1995 B Surge Immunity WARRANTY Product Warranty Period (Worldwide) Connected Equipment Insurance (U.S., Canada & Puerto Rico) 2-year limited warranty $250,000 <a class="insurancelink" href="//www.tripplite.com/support/insurance-policy">ultimate Lifetime Insurance</a> 2018 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies: https://www.tripplite.com/products/product-certification-agencies 7 / 7