Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Similar documents
ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

Line Coupler, MDRC LK/S 2.1, GH Q R0001

Switch Actuator, 4-fold, 16 A, MDRC AT/S , GH Q R0111

Switch Actuator, 4-fold, 20 A, MDRC AT/S , GH Q R0111

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

IP gateway, MDRC IG/S 1.1, GH Q R0001

Line Coupler, MDRC LK/S 3.1, GH Q R0001

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Manual and application description 4 channel 0-10V dimmer V2.0

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

Manual and application description KNX/EIB LED driver V2.0

Operating voltage Maximum

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Electrical devices may only be mounted and connected by electrically skilled persons.

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

ABB i-bus KNX Weather Unit, 1-fold, MDRC WZ/S , 2CDG110184R0011

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

Operating Instructions. DALI-Gateway

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

4 CHANNEL UNIVERSAL DIMMING ACTUATOR

EAE KNX Switch Actuator

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

Product and functional description

The output variables can be force-controlled from a coordinating control system.

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

Product and functional description

ABB i-bus EIB / KNX Shutter Actuator with Manual Operation, 4-fold, SMI, MDRC JA/S 4.SMI.1M. Product Manual. Intelligent Installation Systems ABB

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

Product and functional description

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies

Product Manual V ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1. Intelligent Installation Systems ABB

Product and functional description

Product and functional description

KNX/EIB Intelligent Installation Systems

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S Product Manual

ABB i-bus KNX Blower/Fan Coil-Actuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

Sensor BP Product Manual

As soon as the luminaires are switched off, the built-in relay disconnects the control gear from the mains supply, reducing power loss to 0.5 W.

Product manual. Mylos KNX 350w Dimmer 2CSYK1205C/S

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

K-BUS Shutter Actuator. User manual-ver. 1

An optional analog input module, Order no connected to a 6-pole system connector adds four more analog sensors to the device.

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM02SA/500U

UNIVERSAL DIMMER DIM04SA/500U

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

K-BUS Binary Inputs. User manual-ver. 1

C-Bus Interface Devices for wider control of a home or building.

ABB i-bus KNX Binary Inputs BE/S Product Manual

Operating instructions only for authorized, skilled electricians with EIB training

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

LED Driver DC-String

LED Driver DC-String

The LED display (1) turns green when the load is switched on.

Operating and mounting instructions

KNX DALI Gateway Plus - User Manual

Lighting control for commercial buildings

1 Safety instructions. 2 Device components. 3 Function. DALI Tronic transformer 105 W. Order-No. : Operating instructions

LED Driver Linear / area dimming

OTi DALI 75/ /700 D LT2 UF L

EAE KNX Room Control Unit Product Manual RCUXXYY

DLB1248 single channel EASY-BLE

1 Safety instructions. 2 Device components. 3 Function. DALI transformer W. Art.-No.: D SNT 105. Operationsmanual

Binary Inputs, 4 fold K-BUS R. User manual-ver. 1 CTBI-04/00.1. KNX/EIB Intelligent Installation Systems

PHASED OUT. LED control gear Linear / area dimming. Uconverter LCAI 70 W 300 ma I010 one4all V ECO series

EIB/KNX ENO Radio bus interface (32-channel)

EM2020 Selectable AC transducer A (UK)

Datasheet - SLB 200-C04-1R

ABB i-bus KNX Room Master RM/S 3.1 Product Manual

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

RS485/ KNX Bidirectional Converter K-BUS R. User manual-ver.1.3 BTPT-02/ KNX/EIB Intelligent Installation System

instabus EIB System Actuator

Use of the application program

LED Driver Compact fixed output

LED Driver Linear / area dimming

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Push Button Interface UP 220D31

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

LED Driver DC-String

LED Driver DC-String

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

AB Axis Industries. Use

picture 1: Device components

LED Driver Linear / area dimming

ABB i-bus KNX BCI/S Boiler/Chiller Interface

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

LED Driver Compact fixed output

Tebis application software

1-channel shutter actuator 6A UP Installation Instructions

GVS K-BUS R KNX/EIB Push Button Sensor Contents 1. Summary

Transcription:

SK 0012 B 98 The control unit is a DIN rail mounted device for insertion in the distribution board. It is used to control digitally dimmable electronic ballast devices or transformers via the EIB. In a lighting circuit, up to 50 lux control electronic ballast devices or electronic transformers can be connected to a device. The following functions can be implemented as required: switching, dimming, fixed value, fault indication. The device requires an external auxiliary supply. Bus connection is carried out via a bus connecting terminal at the front of the device. Technical Data Power supply EIB 24 VDC, via the bus line Auxiliary supply 230 V AC, 50 Hz Power consumption 2.6 W Operating and display elements red LED and push button for assigning the physical address Output DSI signals (digital/serial) Nominal voltage 12 V Max. number of electronic ballast 50 devices or electronic transformers Permitted cable length max 250 m Safety short-circuit proof, overload protection, reverse voltage protection Connections EIB Bus connecting terminal (included) Output for DSI signal 2 screw terminals Auxiliary supply 2 screw terminals each for L and N Wire range: finely stranded 0.5-2.5mm², single-core 0.5-4mm² Type of protection IP 20, EN 60 529 Protection class II Ambient temperature range Operation - 5 C 45 C Storage - 25 C 55 C Transport - 25 C 70 C Design modular installation device, prom Housing, colour Plastic housing, grey Mounting on 35 mm mounting rail, DIN EN 50022 Dimensions 90 x 72 x 64 mm (H x W x D) Mounting depth/width Weight Certification CE norm 68 mm / 4 modules at 18 mm 0.23 kg EIB-certified in accordance with the EMC guideline and the low voltage guideline 3-150 May 2000

Application programs Number of Max. number of Max. number of communication objects group addresses associations Switch Dim Value Fault /1 5 10 10 Switch Dim Value Fault /2 5 10 10 Switch Dim Value Fault /3 4 13 13 Circuit diagram 1 3 4 2 5 SK 0180 Z 98 1 Power supply 3 Programming LED, push button 2 DSI output 4 Bus connection 5 Electronic ballast device with DSI connection May 2000 3-151

Switch Dim Value Fault /1 Selection in ETS2 ABB Illumination Dimmer Switch The actuator can be switched on and off via the 1 bit communication object Output Switch. The brightness value that the actuator uses when it is switched on is defined in the parameters. In the same way, the actuator can also be switched on via object 4 Master On/Off. However this object has the additional function that the communication objects Relative dimming and Brightness value cannot switch the actuator on if the master object has the value 0. In the standard setting, the actuator operates with a softstart and a softstop function. This means that it does not use the new status immediately but only dims to the required value at a specified speed. The periods for the softstart and softstop can be set individually. Provided that the transmission flag of the switching object is set, the communication object sends a status telegram after each change in the status. If several actuators are controlled via the same group address, only one of them should have the transmission flag set or they should each use a unique group address as a sending group address so that they do not permanently send new telegrams. Dimming The connected luminaires can be dimmed with the 4 bit communication object according to EIS 2. If the actuator is switched off, it can be dimmed on via the 4 bit object. In the standard setting, the actuator can only be dimmed down to the minimum brightness. If the parameter Dim off is set to yes, it is also possible to dim the luminaire off beyond the minimum brightness value. It is possible to specify in the parameters the period for passing the dimming range from minimum to maximum brightness. The setting range can be limited using the two parameters Lower dimming threshold and Upper dimming threshold. Value Using the 1 byte communication object, the luminaire can be given one of 256 brightness values ranging from 0 = off to 255 = total brightness. If the brightness value is changed via this communication object, the actuator can either use the new value immediately or it can dim up from the current to the new brightness value within a set period. Provided that the transmission flag is set, the communication object sends a telegram after each change in the status. If several actuators are controlled via the same group address, only one of them should have the transmission flag set or they should each use a unique group address as a sending group address so that they do not permanently send new telegrams. Fault If there is a defective lamp, the auxiliary supply fails or there is an error on the DSI bus, the object Fault indication sends a telegram with the value 1. If the fault is rectified, it sends a telegram with the value 0. 3-152 May 2000

Communication objects No. Type Object name Function 0 1 bit Output Switch 1 4 bit Dimmer Relative dimming 2 1byte Dimmer Brightness value 3 1 bit Fault indication Telegr. fault status 4 1 bit Master object Master On/Off Parameters The default setting for the values is printed in bold type. DSI flags Softstart yes / no Softstop yes / on Brightness value dim to setpoint / jump to setpoint Dim off yes / no DSI parameters Switch ON brightness last value 1% 100% Lower dimming threshold 1% Upper dimming threshold 80% 90% 9 100% Duration: softstart 0.4 s / 0.8 s / 1.2 s /... / 30 s / 50 s Duration: softstop 0.4 s / 0.8 s / 1.2 s /... / 30 s / 50 s Duration: dim to setpoint 0.4 s / 0.8 s / 1.2 s /... / 30 s / 50 s Duration: dimming 0... 100% 2 s / 3 s / 4 s / 5 s /... / 40 s / 50 s May 2000 3-153

Switch Dim Value Fault /2 Selection in ETS2 ABB Illumination Dimmer Switch The actuator can be switched on and off via the 1 bit communication object Output Switch. The brightness value that the actuator uses when it is switched on is defined in the parameters. In the same way, the actuator can also be switched on via object 4 Master On/Off. However this object has the additional function that the communication objects Relative dimming and Brightness value cannot switch the actuator on if the master object has the value 0. If the actuator is switched on and receives a further On telegram, it can either use the set starting brightness value or the maximum brightness value. This is determined via the parameter Reaction on twice ON. The actuator operates if required with a softstart and a softstop function. This means that it does not use the new status immediately but only dims to the required value at a specified speed. The periods for the softstart and softstop can be set individually. Provided that the transmission flag of the switching object is set, the communication object sends a status telegram after each change in the status. If several actuators are controlled via the same group address, only one of them should have the transmission flag set or they should each use a unique group address as a sending group address so that they do not permanently send new telegrams. Dim The connected luminaires can be dimmed with the 4 bit communication object according to EIS 2. If the actuator is switched off, it can be dimmed on via the 4 bit object. In the standard setting, the actuator can only be dimmed down to the minimum brightness. If the parameter Dim off is set to yes, it is also possible to dim the luminaire off beyond the minimum brightness value. It is possible to specify in the parameters the period for passing the dimming range from minimum to maximum brightness. The setting range can be limited using the two parameters Lower dimming threshold and Upper dimming threshold. Value Using the 1 byte communication object, the luminaire can be given one of 256 brightness values ranging from 0 = off to 255 = total brightness. If the brightness value is changed via this communication object, the actuator can either use the new value immediately or it can dim up from the current to the new brightness value within a set period. Provided that the transmission flag is set, the communication object sends a telegram after each change in the status. If several actuators are controlled via the same group address, only one of them should have the transmission flag set or they should each use a unique group address as a sending group address so that they do not permanently send new telegrams. Fault If there is a defective lamp, the auxiliary supply fails or there is an error on the DSI bus, the object Fault indication sends a telegram with the value 1. If the fault is rectified, it sends a telegram with the value 0. 3-154 May 2000

Communication objects No. Type Object name Function 0 1 bit Output Switch 1 4 bit Dimmer Relative dimming 2 1byte Dimmer Brightness value 3 1 bit Fault indication Telegr. fault status 4 1 bit Master object Master On/Off Parameters The default setting for the values is printed in bold type. General Switch ON brightness last value 1% 100% Reaction on twice ON maximum value selected switch ON brightness Lower dimming threshold 1% Upper dimming threshold 100% 80% 90% 9 Duration: dim 0... 100% 2 s / 3 s / 4 s / 5 s /... / 40 s / 50 s Dim On/Off Softstart yes / no If yes is selected: Duration: Softstart 0.4 s / 0.8 s / 1.2 s /... / 30 s / 50 s Softstop yes / no If yes is selected: Duration: Softstop 0.4 s / 0.8 s / 1.2 s /... / 30 s / 50 s Brightness value jump to... / dim to... If dim to is selected: Duration: Dim to 0.4 s / 0.8 s / 1.2 s /... / 30 s / 50 s Dim off yes / no May 2000 3-155

Switch Dim Value Fault /3 Selection in ETS2 ABB Illumination Dimmer Switch The actuator can be switched on and off via the 1 bit communication object Output Switch. The brightness value that the actuator uses when it is switched on is defined in the parameters. If the actuator is switched on and receives a further On telegram, it can either use the set starting brightness value or the maximum brightness value. This is determined via the parameter Reaction on twice ON. The actuator operates if required with a softstart and a softstop function. This means that it does not use the new status immediately but only dims to the required value at a specified speed. The periods for the softstart and softstop can be set individually. If the parameter Object 0 sends on brightness value 0 is set to telegram with the value 0, the actuator cannot be switched on via the objects Relative dimming and Brightness value. Dim The connected luminaires can be dimmed with the 4 bit communication object according to EIS 2. If the actuator is switched off, it can be dimmed on via the 4 bit object. In the standard setting, the actuator can only be dimmed down to the minimum brightness. If the parameter Dim off is set to yes, it is also possible to dim the luminaire off beyond the minimum brightness value. It is possible to specify in the parameters the period for passing the dimming range from minimum to maximum brightness. The setting range can be limited using the two parameters Lower dimming threshold and Upper dimming threshold. Value Using the 1 byte communication object, the luminaire can be given one of 256 brightness values ranging from 0 = off to 255 = total brightness. If the brightness value is changed via this communication object, the actuator can either use the new value immediately or it can dim up from the current to the new brightness value within a set period. Fault If there is a defective lamp, the auxiliary supply fails or there is an error on the DSI bus, the object Fault indication sends a telegram with the value 1. If the fault is rectified, it sends a telegram with the value 0. 3-156 May 2000

Communication objects No. Type Object name Function 0 1 bit Output Switch/Telegr. status 1 4 bit Dimmer Relative dimming 2 1byte Dimmer Brightness value 3 1 bit Fault indication Telegr. fault status Parameters The default setting for the values is printed in bold type. General Switch on with last value 1% brightness brightness brightness brightness brightness brightness brightness 100% brightness Ignition always with brightness, Note thereafter dim/jump to turn-on brightness Reaction on twice ON maximum value selected turn-on brightness Object 0 sends on brightness no telegram value 0 telegram with value 0 If object 0 sends a telegram: The dimming actuator is switched Note off as a result A reset is only possible via Note object 0 Lower dimming threshold 1% Lower dimming threshold 100% 80% 90% 9 Dimming parameters Softstart when switching on yes / no (Ignition brightness > turn-on brightness) If yes is selected: Duration: softstart 0.4 s / 0.8 s / 1.2 s /... / 30 s / 50 s Softstart when switching off yes / no (Act. brightness > lower dimming threshold) If yes is selected: Duration: softstop 0.4 s / 0.8 s / 1.2 s /... / 30 s / 50 s If value of object 2 changes dim up to new value jump to new value If dim up is selected: Duration: dim to value 0.4 s / 0.8 s / 1.2 s /... / 30 s / 50 s Dim off to the lower dimming range to the value 0 The same gradient is used for Note dimming and dimming off Duration for passing the dimming 2 s / 3 s / 4 s / 5 s /... / 40 s / 50 s range May 2000 3-157