A-dec 586 Ceiling Monitor Mount

Similar documents
A-dec 584 Monitor Mount on a Central Cabinet

A-dec 570L Dental Light on a DCS System INSTALLATION GUIDE

EVOLVE1-M MONITOR ARM

ASSEMBLY AND ADJUSTMENT

A-dec Dental Lights and Monitor Mounts Service Reference

Quick Installation Guide

Installation Guide Philips MP20/30/40/50/60/70 IntelliVue M-Series Arm Rail Mount Kit

Extra Large Full Motion TV Mount for Televisions

CLIMB2 DUAL MONITOR SIT/STAND WORKSTATION

Quick Installation Guide

Treadmill Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

Quick Installation Guide

Flat Panel Static Wall Mount MSP-SS (GSM-210)

Rack Installation Instructions

Dell Wyse Client VESA Mounting Bracket for Dell P Series Monitor Installation Instructions

Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays

INSTALLATION INSTRUCTIONS

FLEXBOX. Installation Guide

IBM. Rack Installation Instructions

C764i Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

Assembly Instructions for #5630 Medication PalWOW

PMCL Series Mounts RACK/CEILING/WALL MOUNTS, UNIVERSAL CAMERA MOUNT, MONITORS

Cycles Integrated LCD Screen Option. Cardio Theater Integrated Bracket Assembly Instructions

Installation Guide. Universal Camera Mount Bracket

NAV-1 Lens Support. NAV-2 Lens Support BEFORE YOU BEGIN

Installation Guide Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

GCX Mounting Assembly Installation Guide. Pedestal Mount for Philips IntelliVue MP5/20/30/40/50/60/70, MX400/450/500/550/600/700/800

PFPDARM3 Product Illustration

DIGITAL Server Rackmount Installation Guide

7" Touch Screen Display

KRONOS 6752 LIFT DESK

Portable Staging User Guide

HD NO HOLES MOUNT RAM SSV

MBE Mounts and Adapters

Installation Guide Philips MP60/70 IntelliVue VHM Arm Rail Mount Kit

Dual TV/Monitor Desk Mount Stand (Duplex Series) Model: DE9E2S-S

Upgrade Instructions Printer Terminal Holder

Parts and Service Manual IMCO

System Storage EXP3000 Rack Installation Instructions

Articulating TV/Monitor Clamp/Grommet Desk Mount Model: DE640S (Hydro Series)

Description: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447

Liebert XDA Air Flow Enhancer. User Manual

A note about our online installation instructions:

DUAL-ARM MONITOR MOUNT For in. ( cm) desktop computer monitors

IS-DM220/IR/HB IS-DM220

3500 Series Tripod Kit

G12/G12x USER S MANUAL

Heat Containment System (HCS)

CENTRO 6451/6452 LIFT DESK

7403 K321. Display Wall Mount. Kit Instructions. Issue A

Service Bulletin. MiTek. RoofTracker Roof Truss Roller Press. Machinery Affected: Adding an Operator Platform. Machinery Division

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Ag Leader Technology. DirectCommand Installation Hardi 20-pin Interface Kit (Sprayer Chassis Mount)

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Megatouch FORCE Monitor Chassis Board Replacement

Part Name/Description Part Number Quantity

Warning Before Installation. Package Contents EN - 1. Refer to your user's manual for the operating temperature.

PDC / ECIS. Display Update update with conversion kit Display Update. Contents. General information. Important notes.

Titan Media Cart. Installation and Operation Manual

Warning Before Installation

Installation Guide GE Healthcare Solar 8000M Keypad Mounting Kit for 15'' and 18'' Flat Panel Displays

Installation Instructions Access Dual Roller FlexShade System by Draper

TDM To MiniMech conversion ProceDure

Cone Beam Volumetric Tomography and Panoramic Dental Imaging System

Print Mechanism Maintenance Kit

QUIK-LOK S LINE OF WALL-MOUNTING SYSTEMS FOR LCD/PLASMA TV s & PROJECTORS

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

In-Sight 7000 Series Vision System. Optional Configurations

MD-BSL15W / SPRING-LOADED TWIN-ARM. For ( cm) LCD desktop computer. User Manual

M-2300-ZX Focus SVT Brake Conversion Kit INSTRUCTION SHEET

TRC-190 User s Manual

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

V.I.A. - Monitor Shroud

Modular Series Mounting Solutions

FLOE WIRELESS REMOTE ASSEMBLY INSTRUCTIONS KIT P/N

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

Ultra short throw lens installation

MD-BD13B / DUAL SEGMENT TWIN-ARM. For (33-69 cm) LCD desktop computer monitors. User Manual

CONSOLE CONNECTOR KIT 9501 INSTALLATION INSTRUCTIONS

Gateway Profile 4 service guide

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

Installing a Power over Ethernet injector

Mounting on the Ceiling Using Flush Mount (Face Down)

SEQUEL 6051/6052 LIFT DESK

ALL-FLEX ELECTRIC TABLE BASE

Part Name/Description Part Number Quantity

Cutter Option Installation Instructions

Copy Machine Reader. Installation and Setup Guide

Vector Frame Light Box R-07

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

Setup Information Panosaurus May 3, 2011

Eaton Heat Containment System (HCS) Installation Guide

Vacuum Maintenance Manual (EXCERPT Tim Benedict)

Innovative Americans, LLC. HD Media Pack Installation Manual

The A-dec Difference.

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Digital Menu Board Wall Mount Installation Instructions

Sit-Stand Monitor Arm

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

Full HD Speed Dome IP Camera

Transcription:

Installation Guide A-dec 586 Ceiling Monitor Mount Recommended Tools 7/16" wrench Socket set and ratchet with 6" extension Phillips head and standard screwdrivers Diagonal cutters Level 3/8" drill with a 3/16" drill bit 2-1/8" to 2-1/4" hole saw Hex key set Important Information Check with local building and code authorities about installation requirements specific to your location. CAUTION Use a SJT type cable when connecting power to the monitor. SJT cables are more durable than the SVT cables typically provided by monitor manufacturers and are required when routed through moving arms. Use a monitor that weighs 20 lb or less and fits on a 75 mm or 100 mm VESA pattern mount. Always follow local building and electrical codes. NOTE Not all parts included in this kit may be necessary for your particular installation or configuration. 86.0066.00 Rev H

Determine the Mounting Location 1. Determine the mounting location for the ceiling monitor mount in relation to the dental chair. 2. Ask the doctor to determine if a left or right hand installation is preferred. NOTE The image below shows the recommended locations to place the A-dec ceiling monitor mount. The primary recommendation for each system minimizes light and monitor arm interference. These recommendations work with all A-dec dental chairs. Recommended Mounting Locations (B - Head of Baseplate, C - Centerline of Chair, S - Side of Chair) Without a Ceiling Track Light B 4" - 6" (102-153 mm) S2 Mounting Location for Right-Handed Operator C1 8" 16" - 18" (406-457 mm) 16" - 18" (406-457 mm) 4" - 6" (102-153 mm) B S1 Mounting Location for Left-Handed Operator With a Ceiling Track Light 6 1/2" (165 mm) B 4" - 6" (102-153 mm) 15" (381 mm) S2 16" - 18" (406-457 mm) C2* 4" - 6" (102-153 mm) B S1 16" - 18" (406-457 mm) A-dec 6300 Ceiling Track Light Monitor Mount and Light Compatibility System With This Light Primary Recommendation Secondary Recommendation Track-Mount Ceiling-Light S1 or S2 C2* (See the note at the top of page 3.) Fixed-Mount Ceiling Light C1 S1 or S2 Chair or Cabinet Mount Lights S1 or S2 C1 2 86.0066.00 Rev H

NOTE If you are installing in the C2 position, you must have a 6-1/2" space between the front of the track mount ceiling light on the center line of the baseplate and the monitor mount post location. See the image under Recommended Mounting Locations on page 2. A space less than 6 1/2" will result in the monitor being too close to the patient s face when the patient is upright in the chair. If you cannot obtain the minimum 6 1/2" distance, we recommend a different configuration. Contact your A-dec dealer for more information. NOTE After the installation is complete, the monitor mount should measure a minimum of 89" (2261 mm) from the bottom of the extension arm to the floor. Proper Installation Height 9' 10' Recommended Distance is 89" to 95" Long Post (for use on a 9'-6" to 10' false ceiling) 86.0066.00 Rev H 3

Determine the Ceiling and Bracing Type Determine the type of ceiling (wood frame or suspended) to which the dental light is being installed and complete any required modifications to the ceiling structure. New Construction Ceiling Joists Finished Ceiling False Ceiling Mounting Structure Information Leave a maximum of 6" (152 mm) clearance between the false ceiling and the support structure to ensure correct product height for a given ceiling height and post length. False Ceiling Ceiling Joists Mounting Structure 6" Maximum Mounting Plate with Collar Power Supply Conduit and Data Line False Ceiling Cover Mounting Plate With Collar and Post Existing Construction Ceiling Joists Finished Ceiling Mounting Plate with Collar Power Supply Conduit and Data Line Suspended Ceiling Metal Construction Ceiling Joists 4 86.0066.00 Rev H

Install the Monitor Mount Install the Ceiling Mounting Plate 1. Position the mounting template (included in the kit) on the ceiling. Mark the mounting holes, power stub, and data line. NOTE When securing the mounting plate and post, position the collar bolt holes in relation to the chair's position as shown in the image under Recommended Mounting Locations on page 2. Be sure to position the threaded hole for the collar bolt next to the junction box. 2. Make sure the electrical power conduit reaches the access holes in the top of the mounting plate. 3. Drill the 3/16" (4.8 mm) diameter mounting holes. 4. Use a Phillips head screwdriver to remove the junction box cover before mounting the plate to the ceiling. Use a 7/16" socket and ratchet and the lag screws from the kit to mount the plate to the ceiling. Install the Ceiling Mounting Plate Wire and Level the Post 1. Connect the electrical wiring with wire nuts as follows: Brown wire from the power cord to the black or brown wire from the electrical stub. Blue wire from the power cord to the white or blue wire from the electrical stub. Green/yellow wire from the power cord to the ground wire from the electrical stub, and the green wire from the junction box. Black/Brown Wire from Electrical Stub Brown Wire from Power Cord Ground Wire from Electrical Stub Green/Yellow Wire from Power Cord White or Blue Wire from Electrical Stub Blue Wire from Power Cord Green Wire from Junction Box Cable Hole Mounting Holes Lag Screws 86.0066.00 Rev H 5

2. Replace the junction box cover. Route the power cord and audio/video cables through the post and slide the post up into the collar. For monitors with a long post, use a piece of tubing tied to the power cord to pull the cord and audio/video cables through the post. 3. Line up the holes in the post and the collar where the collar bolt installs. (It does not matter where the slot in the post faces.) Use a 7/16" socket and ratchet to install the bolt through the collar and post. Firmly tighten the bolt. Connect the Extension Arm 1. Apply a light coat of Lubriplate TM to the extension arm groove and bushings. Stop Screw Extension Arm Collar Bolt 2. Lubricate the joint retainer. Collar Audio/Video Cables Power Cord Install the Cover 1. Remove the retainer ring, and push the mount cover over the post. 2. Attach the retainer ring over the post and secure it with the cable ties. Push the mount cover up to the ceiling. Retainer Ring Mount Cover Retainer Ring Post Cable Ties Post 6 86.0066.00 Rev H

3. Insert the extension arm in the post. 4. Insert the joint retainer. CAUTION Keep a firm hold on the extension arm to stabilize it while installing the joint retainer. 5. Use a 1/8" hex key and two 10-32 x 5/16" button head screws to secure the joint retainer. NOTE Note the position of the stop screw before securing the extension arm. The stop screw sets the rotation limits of the extension arm. For more details, see Stop Screw Rotation Limits on page 10. Install the Flexarm 1. Apply a light coat of Lubriplate to the flexarm adaptor groove. Stop Screw Flexarm Adaptor 2. Lubricate the joint retainer. Joint Retainer Post Stop Screw Joint Retainer Actual Size 10-32 x 5/16" 3. Insert the flexarm in the extension arm collar. CAUTION Keep a firm hold on the flexarm to stabilize it while installing the joint retainer. Extension Arm 6. Remove the plug from the extension arm. 7. Route the monitor cables down through the post and the extension arm. 8. Replace the plug. Extension Arm Monitor Cables Plug 86.0066.00 Rev H 7

4. Use a 1/8" hex key and two 5/16" button head screws to secure the joint retainer. Extension Arm Collar Flexarm Stop Screw Joint Retainer Install the Monitor NOTE The ceiling monitor mount is designed to accommodate: A medical grade monitor 20 lb (9 kg) maximum monitor weight Either a 75 mm or 100 mm VESA pattern mount Only monitors configured with an internal power supply 1. If the mounting holes on the monitor are recessed, use four 10-32 x 3/8" screws and nuts to install the recessed adaptor. Actual Size 10-32 x 3/8" Monitor Bracket NOTE Note the position of the stop screw before securing the flexarm. For more details, see Stop Screw Rotation Limits on page 10. Recessed Adaptor 5. Route the monitor cables down through the extension arm, and then through the flexarm knuckle. Extension Arm Flexarm Monitor Cables 2. Attach the monitor to the monitor bracket. Use the four screws that are shipped with the monitor. Monitor Monitor Bracket Knuckle 8 86.0066.00 Rev H

Install the Monitor Rotation Adaptor 1. Lubricate the monitor rotation adaptor and joint retainer. Stop Screw Rotation Adaptor Joint Retainer 3. Insert the monitor adaptor in the flexarm. 4. Secure the joint retainer with the two screws. CAUTION Keep a firm hold on the extension arm to stabilize it while installing the joint retainer. NOTE Take note of the position of the stop screw before securing the monitor bracket. For more details, see Stop Screw Rotation Limits on page 10. Flexarm 2. Route the monitor cables down through the adaptor. Stop Screw Button Head Screw Joint Retainer Rotation Adaptor 86.0066.00 Rev H 9

Adjust the Monitor Mount Stop Screw Rotation Limits The image below shows the three locations and the limits of the stop screws. Recommended Stop Screw Locations Flexarm Stop Extension Arm Stop Mounting Bolt (facing away from chair) Monitor Stop Flexarm Stop Extension Arm Stop S2 C2 C1 Mounting Bolt (facing away from chair) S1 Monitor Stop Flexarm Stop Monitor Stop Extension Arm Stop Mounting Bolt (facing away from chair) 10 86.0066.00 Rev H

Change the Rotation Stop Location The stop screw sets the rotation limits. There are three joint locations (monitor, flexarm, and extension arm), with four stop screw positions at each location that rotate 310º from stop to stop. See Stop Screw Rotation Limits on page 10. To achieve the proper rotation angle of the extension arm, flexarm, or monitor adaptor, you must relocate the stop screw to one of the four stop screw positions. 1. Use a 1/8" hex key to remove the screws securing the joint retainer, and then remove it. 2. Rotate the extension arm, flexarm, or adaptor until the stop screw is visible. 3. Use a Phillips head screwdriver to remove the stop screw. 4. Rotate the extension arm, flexarm, or adaptor to locate the new mounting hole location. 5. Install the stop screw. 6. Rotate the arm away from the stop screw, then reinstall the joint retainer. Joint Retainer Joint Retainer Stop Screw 5/16" Button Head Screws Hex Key Adjust the Monitor Handles Use a 5/32" hex key to remove the screws securing the monitor handles to the monitor. Move the handles to the desired position and secure them with the screws. Screws Handle 86.0066.00 Rev H 11

Adjust the Tilt Friction The tilt friction adjustment allows you to adjust the pivot tension of the monitor. Use a 5/32" hex key to adjust the tilt friction. 5/32" Hex Key Tilt Clutch Adjust the Flexarm Counterbalance When you install the monitor, the flexarm might drift slightly up or down. If the flexarm drifts down, see Increase the Tension. If it drifts up, see Decrease the Tension. Increase the Tension Use a 7/16" wrench to turn the nut. Do not rotate the nut past the second groove. Adjust the Lower Vertical Post 1. Use a 7/16" wrench to adjust the alignment of the monitor to the flexarm. 7/16" Wrench Do not rotate the nut past the second groove. 7/16" Wrench Decrease the Tension Use a 3/8" socket and ratchet with a 6" extension to loosen the bolt at the front of the flexarm. The factory preset for this bolt is all the way in so initially you can only loosen the bolt. 3/8" Socket Adjustment Bolt 12 86.0066.00 Rev H

Install the Covers Install the Monitor Bracket Cover 1. Use a 1/8" hex key to attach the monitor bracket cover using the two screws provided. Install the Flexarm Covers 1. Insert the two posts of the attached cover into the outside holes on the flexarm. 2. Use a 5/32" hex key through the access hole and two 1/4-20 x 1/2" screws to secure the cover. 3. Line up the ball snaps and snap the covers together. Button Head Screw Monitor Bracket Cover NOTE The monitor mount bracket cover is designed to accommodate monitors configured with an internal power supply. Outside Holes Flexarm Cover (Snap) Ball Snaps Screws Ball Snaps Actual Size 1/4-20 x 1/2" CAUTION When removing or replacing covers, take care not to damage any wiring or tubing. Verify that the covers are secure after replacing them. Left Side Flexarm Cover (Attach) Outside Holes 86.0066.00 Rev H 13

14 86.0066.00 Rev H

86.0066.00 Rev H 15

Regulatory Information Regulatory information mandated by agency requirements is provided in the Regulatory Information, Specifications, and Warranty document (p/n 86.0221.00), which is available in the Document Library at www.a-dec.com. Product Models and Versions Covered in This Document Lubriplate is a trademark of the Lubriplate Lubricants Co. Models Versions Description A-dec 586 A Monitor Mount A-dec Headquarters 2601 Crestview Drive Newberg, OR 97132 USA Tel: 1.800.547.1883 Within USA/CAN Tel: +1.503.538.7478 Outside USA/CAN Fax: 1.503.538.0276 www.a-dec.com A-dec Inc. makes no warranty of any kind with regard to the content in this document including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. ÍvÈ.ÇÂbÈ.00kÎ 86.0066.00 Rev H Copyright 2017 A-dec Inc. All rights reserved. IGporeven12