Complete Range of Optical Tensiometers Contact Angle Meters

Similar documents
Theta. Complete Range of Optical Tensiometers / Contact Angle Meters. Versatility, automation and accuracy

Theta. Complete Range of Optical Tensiometers / Contact Angle Meters. Versatility, automation and accuracy

Contact Angle Instruments For the measurement of surface properties

Theta Lite (TL100 and TL101) Manual OneAttension

Drop Shape Analysis System DSA100

RD-SDM02 Contact Angle Measurement Instrument. Operation Manual

O C A p r o d u c t s e r i e s

Using Fringe Projection Phase-Shifting to Correct Contact Angles for Roughness Effects. June th, 2016 Greg Wills Biolin Scientific

Titelbild. Höhe: 13cm Breite: 21 cm

Contact Angle Measuring Instrument. User Manual. Ahmed Abdelmonem 27/02/2008. Home made

Introduction to the FTA4000

Software for Drop Shape Analysis

Software for Drop Shape Analysis DSA1

What is the shape of an air bubble on a liquid surface?

Discovery Hybrid Rheometer

Mitos P-Pump. product datasheet

Tribometers. nanovea.com

The Most User-Friendly 3D scanner

DMA 500. Density/Specific Gravity/ Concentration Meter. ::: Unique Density & Concentration Meters

TRIBOMETERS MICRO-MACRO TRIBOLOGY TESTING

Product Brochure. DataVU. Paperless Recorders.

The VARIO Chemistry-pumping units with adaptive vacuum control

CONTACT ANGLES OF PENDANT DROPS ON ROUGH SURFACES

Versatile. Innovative. Customizable M CVAF Mercury Analyzer

AccuTank ULTRASONIC LEVEL MONITORING SYSTEM

Introducing DataVU. The New Range of Paperless Recorders from Partlow

Two-Dimensional Contact Angle and Surface Tension Mapping (As Presented at Pittcon 96)

Microfluidics Santa Clara, California U.S.A. October 17, 2012

Thermo Scientific Spectronic 200 Visible Spectrophotometer. The perfect tool. for routine measurements

The Power and Ease of use of the EasyVSM Software

The DDM 2909 Automatic Density Meter

Supplementary Information for. A self-cleaning underwater superoleophobic mesh for oil-water separation

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system

Friction & Roughness Measurement of Elastomer

Ink testing for industrial printers

Surface Tension Measurement of Melted Metals and Slag by the Methods of Image Analysis 1

VISION IMPACT+ OCR HIGHLIGHTS APPLICATIONS. Lot and batch number reading. Dedicated OCR user interface. Expiration date verification

Typical System Construction Schedule; Balzers Chambers: BAK600 BAK760 QLC800

dome camera. Image Inverse feature

STROBOLUX III LED STROBOSCOPE TECHNOLOGY AND PRECISION IN STROBOSCOPIC LIGHT

Size and Shape Particle Analyzer. Synchronizing Size & Shape Wet & Dry Measurements.01 to 4000 µm COATINGS

Product information. Hi-Tech Electronics Pte Ltd

DAILY LINAC QA BEAM QA

WETTING PROPERTIES OF STRUCTURED INTERFACES COMPOSED OF SURFACE-ATTACHED SPHERICAL NANOPARTICLES

Presented at the 29th European PV Solar Energy Conference and Exhibition, September 2014, Amsterdam, The Netherlands

GSSEA-Light. Lecture 1: Introduction to the Statistical Energy Analysis Software

IMAGING SOFTWARE. Image-Pro Insight Image Analysis Made Easy. Capture, Process, Measure, and Share

The Perfect Fit for Over 40 Years

QUALITROL QTMS Transformer Monitoring System

Introduction.

FULLY AUTOMATED 2 MICROPLATE ANALYZER

DSA4. Software for Drop Shape Analysis. User manual part 1: Installation, introduction, working in standard mode V2.0-02

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

DVR DVR VENEZIA series

WIRELESS ENVIRONMENTAL MONITORS

Always with You, Always On. With LG, it s all possible.

DMA 500. Density/Specific Gravity/ Concentration Meter. ::: Unique Density & Concentration Meters

Particle size range (0.8 microns 1000 microns)

Touch technology and collaboration are brought to life with the brilliance of our 4K ultra high-definition LCD flat panel Android display.

SX 6000 Paperless Recorder

Dynamic Mechanical Analyzer MCR 702

CONVERSION OF ECONOMY 3D PRINTER TO E-JET PRINTER

More Precision. thermoimager TIM // Compact thermal imaging cameras

Technical Specifications for High speed PIV and High speed PIV-PLIF system

Acoustic Camera Nor848A

NANOMETRIC LAB PRINTER. Plug & Play Solution for ultra-precise printing of conductive lines in nano-scale

PVA2000 SELECTIVE CONFORMAL COATING SYSTEMS

Selection can be made from different capacities (ranging from 100kN to 2000kN) from HL 590 / HL590 (FL) series or HLC 591 / HLC 591 (FL) series.

Ultrospec 10 User Manual. English. Deutsch. Français. Español. Italiano

MegaVideo Flex. Wide Dynamic Range Available on Some 1080p and 3MP Models. True Day/Night with Mechanical IR Cut Filter

Portable Density/Specific Gravity/Concentration Meter

The Autopol VI Automatic Polarimeter

Movit System G1 WIRELESS MOTION DEVICE SYSTEM

Sample Sizes: up to 1 X1 X 1/4. Scanners: 50 X 50 X 17 microns and 15 X 15 X 7 microns

ZLS Corporation. ZLS Dynamic Meter for Marine Applications EXCELLENCE IN GRAVITY METERS. ZLS Dynamic Meter. Applications

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

FIRST STAND ALONE SERVO-HYDRAULIC TSRST

Protocol Procedures for OCA15EC

Mu lt i s p e c t r a l

Providing the missing piece in your Condition Based Monitoring platform

USER MANUAL HD2. HD 2K Camera Pen.

micro-gloss The new intelligence in gloss measurement Brilliant color display: easy to read - easy to use Auto diagnosis: Standard OK - Calibration OK

DEVELOPMENT OF AXISYMMETRIC DROP SHAPE ANALYSIS - NO APEX (ADSA-NA) Ali Kalantarian

IPS Sealing. Capability. Benefits. Results

VECTRA-TOUCH

UNIVERSAL TESTING MACHINE

PVM-X300. 4K Professional Video Monitor

NEXPTZ364P(N)A HIGH-SPEED EXPLOSION-PROOF PTZ FEATURES.

MULTI-POINT AND SINGLE-POINT

Available online at ScienceDirect. Procedia Engineering 105 (2015 )

CSB-Rack. Robust and reliable for automated online capture of data. Programmed for Your Success

A New Perspective On Things

Gregory Walsh, Ph.D. San Ramon, CA January 25, 2011

COMET 5 3D DIGITIZING

LIGHT SHEET MICROSCOPE. Alphα NEW GENERATION. Ground Breaking Technology For Selective Plane Illumination Microscopy

User's Guide. Video Borescope. Models BR200 and BR250

Fluke Ti40FT and Ti45FT IR FlexCam Thermal Imagers with IR-Fusion Technology

6220 Ethernet-Based Voltage Measurement Module

Certus Optic. NanoScanTechnology. Basic Datasheet. reasoned innovations. Integrated Optical and Scanning Probe Microscope

SYNCERITY TM 1024 x 256

Transcription:

Theta Complete Range of Optical Tensiometers Contact Angle Meters Versatility, automation and accuracy

Precision made simple Attension Optical Tensiometers are used in research, development and quality control for the study of surfaces and interfaces. They will help you characterize your surfaces easily and precisely, saving you valuable time and money. The Attension Optical Tensiometer offering enables a wide range of applications from advanced research to quick quality control. Thanks to the versatility, you can get the combination of features that best fits your needs. VISUALIZE THE POSSIBILITIES [ APPLICATION EXAMPLES ] Functional surfaces Adhesion in composites 180 150 2,0 Contact Angle (degree) 150 120 90 60 30 0 0 10 20 30 40 50 60 120 90 60 30 0 Contact Angle Hysteresis (degree) Adhesive Bonding Strength (N/mm 2 ) 1,9 1,8 1,7 1,6 1,5 R² = 0,9796 1,4 95 100 105 110 115 120 Wash Cycles Contact Angle ( ) Dynamic contact angle measurement giving additional information about the durability of the coating. Ref.: Zhao et al., Langmuir 28, (2012), pp 6328-6335. Adapted with permission from ACS. Adhesion strength and contact angle correlation for composite development. Data from S. Jarusombuti and N. Ayrilmis, European Journal of Wood and Wood Products, 69 (2011) p 375. [2] Attension I Theta I Optical Tensiometers / Contact Angle Meters

Attension Optical Tensiometers Measurements Attension Optical Tensiometers can measure: Static contact angle Dynamic contact angle Surface free energy (SFE) Surface tension Interfacial tension Batch contact angle Roughness corrected contact angle Interfacial rheology (viscoelasticity) Technology An optical tensiometer records drop images and automatically analyzes the drop shape. The drop shape is a function of the surface tension of the liquid, gravity and the density and humidity difference between sample liquid and surrounding medium. On a solid, the drop shape and the contact angle also depends on the properties of the solid (e.g. surface free energy, topography). The captured image is analyzed with a drop profile fitting method in order to determine contact angle and surface tension. Surface free energy can be calculated by performing contact angle measurements with several known liquids. Measurement methods Sessile drop for static contact angle measurement of a liquid droplet Advancing drop for dynamic contact angle measurement Tilted drop for dynamic contact angle measurements Receding drop for dynamic contact angle measurement As an optical method, the measurement precision of optical tensiometers depends on the quality of the pictures and the analysis software. Attension Optical Tensiometers utilize a high quality monochromatic cold LED light source to minimize undesirable sample evaporation. Image quality is guaranteed by a high-resolution digital camera, quality optics and the accuracy of the drop fitting method. Meniscus for static contact angle measurement with a fiber/rod Captive bubble for static contact angle measurement of a gas bubble Pendant drop for surface and interfacial tension Reverse pendant drop for surface and interfacial tension Pulsating drop* for dilational interfacial rheology measurement 3D Topography* for roughness corrected contact angle Batch sessile drop for static contact angle measurements in quality control * available only with Theta Optical Tensiometer Attension I Theta I Optical Tensiometers / Contact Angle Meters [3]

[ PRODUCT RANGE ] Theta Optical Tensiometer Theta is the ultimate Attension contact angle meter enabling full automation and optimal ease of use even for the most demanding industrial and research applications. Due to the smart modular design, the system is adaptable to all applications to bring you reliable and user independent results in all situations. Complete range of measurements Static contact angle Dynamic contact angles Surface free energy Surface tension Interfacial tension Batch contact angle Roughness corrected contact angle Interfacial rheology (viscoelasticity) High pressure and high temperature measurements Full automation The system can be fully automated, and measurements can be performed easily with a single click. Versatility and high performance Theta modularity allows you to choose a system that matches your application precisely and upgrade it later if needed. Best-in-class software OneAttension is an all-inclusive software providing all measurement modes, superior drop shape analysis, continuous drop volume monitoring, live results, and the friendliest user interface available. [4] Attension I Theta I Optical Tensiometers / Contact Angle Meters

[ PRODUCT RANGE ] Theta Modules and Accessories Theta with 3D Topography Module Attension Theta enables you to tailor your system as you like. Start by designing your standard system: Level of Automation Motorized or manual sample stage Motorized or manual liquid dispenser motion Liquid Dispensing Automatic or manual dispensing Single, double or multi-liquid dispenser Disposable or multi-use solution Fluid Complement your system with the modules and other accessories that are needed for your applications: θ Y Liquid θ m Liquid 3D Topography Module Roughness-corrected contact angle measurements automatically with a single click. For eliminating the effect of surface roughness for contact angle results. High Pressure Chamber Enables measurements at pressures up to 400 bars and temperatures up to 200 C. Designed for enhanced oil recovery and supercritical fluid applications. Separate impact from surface chemistry and roughness in coatings and material development. Theta with 3D Topography Module measures them simultaneously in the same spot. Theta with High Pressure Chamber Pulsating Drop Module PD 200 Oscillates drop volume for interfacial rheology studies. Picoliter Dispenser Dispensing of picoliter-sized droplets for small sample areas and inkjet applications. Tilting Cradle For fully automatic dynamic contact angle measurements by the tilted drop method. Environmental Chambers To control the measurement environment including the temperature. For a complete list of accessories, please visit the Theta product page at www.biolinscientific.com/product/theta. Interfacial tension (mn/m) 60 55 50 45 40 35 30 25 20 0 50 100 150 Pressure (bar) Brine water Interfacial tensions between brine/co 2 (triangles) and water/co 2 (squares) as a function of pressure. Measurements performed by Biolin Scientific. Attension I Theta I Optical Tensiometers / Contact Angle Meters [5]

[ PRODUCT RANGE ] Theta Lite Optical Tensiometer Theta Lite is a compact and robust contact angle meter for simple and precise quality control and basic wetting research. The high accuracy is obtained with high quality mechanics combined to an automatic or manual droplet creation. OneAttension software makes the contact angle analysis as simple as it gets to save precious measurement time. Accurate measurement of Static contact angle Dynamic contact angles Surface free energy Surface tension Interfacial tension Batch contact angle Best-in-class software OneAttension is an all-inclusive software providing all measurement modes, superior drop shape analysis, continuous drop volume monitoring, live results, and the friendliest user interface available. Accuracy Theta Lite has been designed to repel inaccuracy. Precise automated or manual droplet deposition will keep the droplet volume the same each time to minimize any result variation. High resolution camera will minimize any optical variation and the software will perform sub-pixel live analysis to give you the results instantly. Ease of use Simple and quick operation widely utilized in quality control and research. No complicated adjustments needed, the system comes fully assembled and ready to perform. For a complete accessory description, please visit www.biolinscientific.com/product/theta-lite [6] Attension I Theta I Optical Tensiometers / Contact Angle Meters

[ SOFTWARE ] OneAttension software OneAttension software combines the most intuitive user interface with a high level of functionality. Some of its main features include: Best-in-class user interface The most intuitive user interface is the key for OneAttension. The software is easy to learn, and the logical interface allows even complex measurements to be performed with ease. Superior analysis accuracy Subpixel analysis accuracy using the industry-standard Young-Laplace equation, first brought to optical tensiometry by Attension. For the most versatile capability, other methods such as Bashforth-Adams and Polynomial are also included. Intuitive interface Live analysis The results are shown real-time during the measurement. You can conveniently monitor your results without the need to switch between measurement and analysis tabs. Full automation OneAttension supports fully automatic measurements. In order to make your result analysis as convenient and accurate as possible, OneAttension also features automatic baseline detection combined with automatic drop fitting. Flexibility for every need OneAttension has been designed to meet the requirements of almost any applications you may have. You can easily adjust measurement parameters to match your specific application needs. Your optimized measurement recipes can then be saved for further use. Live analysis Data handling and exporting made easy Data analysis, plotting, and statistical analysis can all be done with a few clicks to give you accurate results within seconds. All data can easily be exported further to Excel, for example. Optimal for industrial use The Batch Sessile Drop measurement makes it simple to measure static contact angle in quality control. Additionally, measurement reports can be created with a few clicks and the user manager conveniently handles all different users with desired privacy levels. Automatic baseline detection Reporting made simple Attension I Theta I Optical Tensiometers / Contact Angle Meters [7]

[ SPECIFICATIONS ] Available Measurements THETA THETA LITE Static contact angle Dynamic contact angle automatic automatic Surface/interfacial tension Roughness corrected contact angle Interfacial rheology Surface free energy Zisman Plot, OWRK/Extended Fowkes, van Oss Acid-Base, Wu, Neumann s Equation of State, Schultz 1 and 2 Available Measurement Methods Sessile drop Batch sessile drop Captive bubble Pendant drop Reverse pendant drop Meniscus Dynamic contact angle automatic automatic Pulsating drop 3D Topography High pressure Hardware Measuring range (, mn/m) 0...180, 0.01...2000 0...180, 0.01...2000 Accuracy (, mn/m) ± 0.1, ± 0.01 ± 0.1, ± 0.01 Maximum sample size (mm) UNLIMITED 5 95 5180 (w. stage) UNLIMITED 5 45 5 200 (w. stage) Frame interval 0.33 ms... 1000 s 0.48 ms 1000 s Maximum resolution (pixels) 1984 5 1264 1280 5 1024 Maximum measuring speed (fps) 3009 2068 Camera USB3 digital camera USB3 digital camera Light source LED based background lighting LED based background lighting Field of view (diagonal in mm) 1.44...30 2.9...12 mm Disposable tip dispensing Dimensions (basic frame) (mm) H 590 5 W 200 5 L 740 H 310 5 W 130 5 L 495 Weight (basic frame) (kg) 7.3 5 Power supply (vac) 100...240 100...240 Frequency (Hz) 50...60 50...60 Drop Profile Fitting Method Young-Laplace (CA, ST/IT, M) Bashforth-Adams (ST/IT) Circular (CA) Polynomial (CA, M) Software Provided Software OneAttension OneAttension All-inclusive System requirements Recommended system requirements Operating system requirements 2 GHz processor, 2 GB RAM, 120 GB hard disk drive 1, 1024 5 768 resolution, 1 USB2 or USB3 port, 1 USB3 port 1 additional USB2 port required with 3D Topography Module 1 SDD hard disk (min. 500 MB/s) needed for high speed recording with high resolution Windows 7 & 8 & 10 (32 or 64 bit). Ver. 2017-03 All specifications are subject to change without notice. : available : not available/not applicable CA: contact angle ST/IT: surface tension and interfacial tension M: meniscus *: With extended license **: Only for Theta and Theta LIte Biolin Scientific Ab, Hängpilsgatan 7, SE-426 77 Västra Frölunda Phone: +46 31 769 7690 E-mail: info@biolinscientific.com www.biolinscientific.com [8] Attension I Theta I Optical Tensiometers / Contact Angle Meters About Us Biolin Scientific is a leading Nordic instrumentation company with roots in Sweden and Finland. Our customers include companies working with life science, energy, chemicals, and advanced materials development, as well as academic and governmental research institutes. Our precision instruments help develop better solutions for energy and materials, and perform research at the frontiers of science and technology.