SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM STORWIZE V7000 (SSDS) SPC-1 V1.12

Similar documents
SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM SYSTEM STORAGE DS3524 EXPRESS SPC-1 V1.12

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM SYSTEM STORAGE DS8700 RELEASE 5.1 (EASYTIER AND SSDS) SPC-1 V1.12

SPC BENCHMARK 2/ENERGY EXECUTIVE SUMMARY IBM CORPORATION IBM XIV STORAGE SYSTEM GEN3 SPC-2/E V1.4

SPC BENCHMARK 1 EXECUTIVE SUMMARY

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM POWER 780 SERVER (WITH SSDS) SPC-1 V1.13

SPC BENCHMARK 1 EXECUTIVE SUMMARY FUJITSU LIMITED FUJITSU STORAGE SYSTEMS ETERNUS DX200 S3 SPC-1 V1.14

SPC BENCHMARK 1 FULL DISCLOSURE REPORT IBM CORPORATION IBM STORWIZE V3700 (TURBO) SPC-1 V1.14

SPC BENCHMARK 1 EXECUTIVE SUMMARY PILLAR DATA SYSTEMS,INC. PILLAR AXIOM 600 SPC-1 V1.10.1

SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR 5500 V3 SPC-1 V1.14

SPC BENCHMARK 2 EXECUTIVE SUMMARY FUJITSU LIMITED FUJITSU STORAGE SYSTEMS ETERNUS DX8700 S2 SPC-2 V1.4

SPC BENCHMARK 2 EXECUTIVE SUMMARY EMC CORPORATION EMC VMAX 400K SPC-2 V1.5. Submitted for Review: July 30, 2015 Submission Identifier: B00073

SPC BENCHMARK 2 FULL DISCLOSURE REPORT HITACHI DATA SYSTEMS CORPORATION HITACHI UNIFIED STORAGE VM SPC-2 V1.5

SPC BENCHMARK 1C FULL DISCLOSURE REPORT ORACLE CORPORATION SUN STORAGE F5100 FLASH ARRAY SPC-1C V1.3

SPC BENCHMARK 2 FULL DISCLOSURE REPORT SILICON GRAPHICS INTERNATIONAL CORP. SGI INFINITESTORAGE 5600 SPC-2 V1.4

LENOVO THINKSYSTEM DE6000H

SPC BENCHMARK 1 FULL DISCLOSURE REPORT DATACORE SOFTWARE CORPORATION DATACORE SANSYMPHONY-V 10.0 SPC-1 V1.14

SPC BENCHMARK 2 FULL DISCLOSURE REPORT VEXATA INC. VX100-F SCALABLE NVME FLASH ARRAY SPC-2 V1.7.0 SUBMITTED FOR REVIEW: AUGUST 29, 2018

FUJITSU LIMITED ETERNUS AF250 S2

SPC BENCHMARK 1 INSPUR ELECTRONIC INFORMATION INDUSTRY CO. LTD. INSPUR AS5500G2 EXECUTIVE SUMMARY SPC-1 IOPS 1,500,346

MACROSAN TECHNOLOGIES CO., LTD MACROSAN MS3000G2

Nové možnosti storage virtualizace s řešením IBM Storwize V7000

IT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps://

SPC BENCHMARK 1 FULL DISCLOSURE REPORT LENOVO THINKSYSTEM DE6000H SPC-1 V3.8 SUBMISSION IDENTIFIER: A32008

SPC BENCHMARK 1 EXECUTIVE SUMMARY MACROSAN TECHNOLOGIES CO., LTD MACROSAN MS2500G2-25E SPC-1 IOPS 300,028

IBM Storwize V7000 Unified

Exam : Title : Storage Sales V2. Version : Demo

IBM System Storage EXP3500 Express

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 5500 V5

IBM System Storage DS5020 Express

SPC BENCHMARK 1 FULL DISCLOSURE REPORT FUJITSU LIMITED ETERNUS AF650 S2 SPC-1 V3.5.0 SUBMISSION IDENTIFIER: A32004

EMC VMAX 400K SPC-2 Proven Performance. Silverton Consulting, Inc. StorInt Briefing

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 5600 V5

HP P6000 Enterprise Virtual Array

IBM System Storage DS4800

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 6800 V3

IBM Corporation IBM Corporation

Системы хранения IBM. Новые возможности

Introduction to IBM System Storage SVC 2145-DH8 and IBM Storwize V7000 model 524

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 5300 V5

IBM System Storage DCS3700

IOmark- VM. HP MSA P2000 Test Report: VM a Test Report Date: 4, March

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR DORADO5000 V3

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR V3

Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System

FUSIONSTACK CO., LTD FUSIONSTOR SF6000

SAS workload performance improvements with IBM XIV Storage System Gen3

IBM Storwize V5000 delivers simplicity, efficiency, and flexibility for midsize organizations

IBM Storwize V5000 disk system

TELECOMMUNICATIONS TECHNOLOGY ASSOCIATION JET-SPEED HHS3124F / HHS2112F (10 NODES)

C IBM Storwize V7000 Implementation V1

IBM Exam C IBM Storwize V7000 Implementation V1 Version: 6.0 [ Total Questions: 78 ]

Vendor: IBM. Exam Code: Exam Name: Storage Sales V2. Version: DEMO

EonStor DS - iscsi Series High-Availability Solutions Delivering Excellent Storage Performance

IBM EXAM QUESTIONS & ANSWERS

IBM Storwize V ,000 mailbox resiliency Microsoft Exchange 2013 storage solution. IBM Systems and Technology Group ISV Enablement March 2014

IBM Storwize V7000 Technical Solutions V1

IBM TotalStorage FAStT900 Storage Server New Offering Expands IBM SAN Storage Solutions

Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces

Planning for Easy Tier with IBM System Storage Storwize V7000 and SAN Volume Controller

Vendor must indicate at what level its proposed solution will meet the College s requirements as delineated in the referenced sections of the RFP:

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 18800F V5

Dell PowerVault MD Family. Modular storage. The Dell PowerVault MD storage family

IBM Flex System V7000 Storage Node delivers integrated, innovative storage for IBM PureSystems

EonStor DS - SAS Series High-Availability Solutions Delivering Excellent Storage Performance

Accelerating Microsoft SQL Server 2016 Performance With Dell EMC PowerEdge R740

High Volumes Storage Fundamentials V2

VSTOR Vault Mass Storage at its Best Reliable Mass Storage Solutions Easy to Use, Modular, Scalable, and Affordable

IOmark- VDI. IBM IBM FlashSystem V9000 Test Report: VDI a Test Report Date: 5, December

16GFC Sets The Pace For Storage Networks

IBM Storwize V7000 and Storwize V7000 Unified Disk Systems

Dell DL4300 Appliance Interoperability Guide

IBM EXAM QUESTIONS & ANSWERS

IBM Tivoli Storage Manager. Blueprint and Server Automated Configuration for Linux x86 Version 2 Release 3 IBM

IBM IBM Storwize V7000 Technical Solutions V2. Download Full Version :

NEC M100 Frequently Asked Questions September, 2011

Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades

Dell EMC SCv3020 7,000 Mailbox Exchange 2016 Resiliency Storage Solution using 7.2K drives

QSAN XCbueSAN Series Configuration Worksheet

SPC BENCHMARK 1 FULL DISCLOSURE REPORT NETAPP AFF A800 SPC-1 V3.6.0 SUBMISSION IDENTIFIER: A32007

Acer Hitachi AMS2300 specifications

IBM System Storage DS8870 Release R7.3 Performance Update

DELL TM AX4-5 Application Performance

IBM System Storage DS8800 Overview

Vendor: IBM. Exam Code: Exam Name: IBM System Storage DS8000 Technical Solutions V3. Version: Demo

IBM Storwize V7000: For your VMware virtual infrastructure

Dell EMC SC Series SC5020 9,000 Mailbox Exchange 2016 Resiliency Storage Solution using 7.2K Drives

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

IBM Storwize V3700 delivers innovative and easyto-use storage to meet needs of small and medium organizations

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu.

Neuankündigung IBM DS5020

Lenovo Storage V3700 V2 and V3700 V2 XP Product Guide

IOmark- VM. IBM IBM FlashSystem V9000 Test Report: VM a Test Report Date: 5, December

IBM Storwize V7000 TCO White Paper:

Take control of storage performance

Increasing Performance of Existing Oracle RAC up to 10X

PESIT Bangalore South Campus

Highlights. EonStor DS.

SPC-1 * results. Silverton Consulting, Inc. StorInt Dispatch

Executive Brief June 2014

IBM System Storage DS6800

Transcription:

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM STORWIZE V7000 (SSDS) SPC-1 V1.12 Submitted for Review: June 4, 2012 Submission Identifier: A00116

EXECUTIVE SUMMARY Page 2 of 8 EXECUTIVE SUMMARY Test Sponsor and Contact Information Test Sponsor Primary Contact Test Sponsor Alternate Contact Auditor Test Sponsor and Contact Information IBM Corporation http://www.ibm.com Bruce McNutt bmcnutt@us.ibm.com IBM ARC 650 Harry Road San Jose, CA 95120 IBM Corporation http://www.ibm.com Yijie Zhang yijie@us.ibm.com 9000 Rita Road IBM Mail Drop 9042-2 Tucson, AZ 85744 Storage Performance Council http://www.storageperformance.org Walter E. Baker AuditService@StoragePerformance.org 643 Bair Island Road, Suite 103 Redwood City, CA 94063 Phone: (650) 556-9384 FAX: (650) 556-9385 Revision Information and Key Dates Revision Information and Key Dates SPC-1 Specification revision number V1.12 SPC-1 Workload Generator revision number V2.2.0 Date Results were first used publicly June 4, 2012 Date the FDR was submitted to the SPC June 4, 2012 Date the Priced Storage Configuration is available for shipment to customers currently available Date the TSC completed audit certification June 1, 2012

EXECUTIVE SUMMARY Page 3 of 8 Tested Storage Product (TSP) Description The IBM Storwize V7000 disk system, IBM's newest midrange disk storage offering, uses IBM System Storage SAN Volume Controller technology to deliver high performance, advanced function, high availability, and modular and scalable storage capacity. Supports RAID 0, 1, 5, 6, and 10 Provides SAN-attached 8 Gbps Fibre Channel (FC) host connectivity and 1 GbE iscsi host connectivity Accommodates up to twenty-four 2.5-inch disk drives or twelve 3.5-inch disk drives installed within the IBM Storwize V7000 Control Enclosure with attachment support for up to nine IBM Storwize V7000 Expansion Enclosures, providing modular and highly scalable storage solutions that range up to 360 TB physical storage capacity. Supports intermix of SAS drives, Nearline SAS drives, and Solid-state drives within the IBM Storwize V7000 Control Enclosure and IBM Storwize V7000 Expansion Enclosures. Includes IBM Easy Tier technology for automatically moving heavily used data extents onto high-performance storage Supports attachment of other storage devices via the Fibre Channel interface, just as the SAN Volume Controller Supports a complete set of SAN Volume Controller functions including FlashCopy, RemoteCopy, VDisk Mirroring, thin provisioning, and a revised web-based user interface for both products new with this release

EXECUTIVE SUMMARY Page 4 of 8 Summary of Results SPC-1 Reported Data Tested Storage Product (TSP) Name: Metric SPC-1 IOPS 120,492.34 Reported Result SPC-1 Price-Performance Total ASU Capacity Data Protection Level $1.50/SPC-1 IOPS 1,527.100 GB Protected (Mirroring) Total TSC Price (including three-year maintenance) $181,029.02 SPC-1 IOPS represents the maximum I/O Request Throughput at the 100% load point. Total ASU (Application Storage Unit) Capacity represents the total storage capacity read and written in the course of executing the SPC-1 benchmark. A Data Protection Level of Protected (Mirroring) configures two or more identical copies of user data. Storage Capacities, Relationships, and Utilization The following diagram and table document the various storage capacities, used in this benchmark, and their relationships, as well as the storage utilization values required to be reported. Application Storage Unit (ASU) Capacity 1,527.100 GB ASU 1 85.899 GB ASU 2 85.899 GB 8 Logical Volumes 85.899 GB/Logical Volume (ASU 1) 8 Logical Volumes 85.899 GB/ Logical Volume (ASU 2) 2 Logical Volumes 85.899 GB/ Logical Volume (ASU 3) Addressable Storage Capacity 1,546.188 GB ASU 3 76.355 GB Unused Storage 19.089 GB Unused Storage 248.249 GB Overhead/Metadata 1.074 GB Configured Storage Capacity 3,591.022 GB Physical Storage Capacity 3,600.000 GB Data Protection (Mirroring) 1,795.511 GB (includes 267.338 GB of Unused Storage and 1.074 of overhead/metadata) Global Storage Overhead 8.774 GB

EXECUTIVE SUMMARY Page 5 of 8 SPC-1 Storage Capacity Utilization Application Utilization 42.42% Protected Application Utilization 84.87% Unused Storage Ratio 14.85% Application Utilization: Total ASU Capacity (1,527.100 GB) divided by Physical Storage Capacity (3,600.000 GB) Protected Application Utilization: Total ASU Capacity (1,527.100 GB) plus total Data Protection Capacity (1,795.511 GB) minus unused Data Protection Capacity (214.963 GB) divided by Physical Storage Capacity (3,600.000 GB) Unused Storage Ratio: Total Unused Capacity (515.587 GB) divided by Physical Storage Capacity (3,600.000 GB) and may not exceed 45%. Detailed information for the various storage capacities and utilizations is available on pages 21-22 in the Full Disclosure Report.

EXECUTIVE SUMMARY Page 6 of 8 Response Time Throughput Curve The Response Time-Throughput Curve illustrates the Average Response Time (milliseconds) and I/O Request Throughput at 100%, 95%, 90%, 80%, 50%, and 10% of the workload level used to generate the SPC-1 IOPS metric. The Average Response Time measured at the any of the above load points cannot exceed 30 milliseconds or the benchmark measurement is invalid. 30 Ramp Phase Response Time / Throughput Curve 25 20 Response Time (ms) 15 10 5 80% 100% 95% 90% 0 0.45 50% 0 20000 40000 60000 80000 100000 120000 140000 IO Requests per Second Response Time Throughput Data 10% Load 50% Load 80% Load 90% Load 95% Load 100% Load I/O Request Throughput 12,048.96 60,240.56 96,406.36 108,442.25 114,430.47 120,492.34 Average Response Time (ms): All ASUs 0.45 1.14 2.80 3.15 3.78 4.32 ASU-1 0.42 1.03 2.44 2.78 3.32 3.80 ASU-2 0.46 1.09 2.59 2.92 3.49 3.99 ASU-3 0.50 1.39 3.68 4.05 4.87 5.55 Reads 0.41 0.87 1.73 2.05 2.41 2.79 Writes 0.47 1.32 3.51 3.87 4.67 5.31

EXECUTIVE SUMMARY Page 7 of 8 Priced Storage Configuration Pricing Component Quantity Unit Price Unit Maint List w/ Maint % discount Total Price V7000 controller (2076-124) w/8 SFPs, 18-200GB SSDs 1 186,982.00 4,200.00 191,182.00 39 116,621.02 V7000 base software 1 18,000.00 7,200.00 25,200.00 39 15,372.00 24 port fibre channel switch (2498-B24) w/8 ports enabled, 8 SFPs 2 7,120.00 10,800.00 35,840.00 20 28,672.00 5m fibre channel cable (2076-124 5305) 8 129.00 0.00 1,032.00 20 825.60 25m fibre channel cable (2076-124 5625) 8 189.00 0.00 1,512.00 20 1,209.60 4 Gbps dual port FC adapter (9117-5774) 8 3,273.00 0.00 26,184.00 30 18,328.80 Total Price 181,029.02 The above pricing includes hardware maintenance and software support for three years, 7 days per week, 24 hours per day. The hardware maintenance and software support provides the following: Acknowledgement of new and existing problems with four (4) hours. Onsite presence of a qualified maintenance engineer or provision of a customer replaceable part within four (4) hours of the above acknowledgement for any hardware failure that results in an inoperative Priced Storage Configuration that can be remedied by the repair or replacement of a Priced Storage Configuration component. Differences between the Tested Storage Configuration (TSC) and Priced Storage Configuration The two 2498 B4 switches used in the TSC was configured with all 24 ports enabled and with 24 SFPs. Only eight of the ports, in each switch, were used in the SPC-1 measurements. Each of the two switches in the priced storage configuration was priced with eight ports enabled and eight SFPs. This difference, if applied to the TSC, would not have had any impact on the SPC-1 measurements.

EXECUTIVE SUMMARY Page 8 of 8 Priced Storage Configuration Diagram Single 2u Enclosure 18 SSDs Storwize V7000 node Storwize V7000 node 2498 B24 FC Switch 2498 B24 FC Switch 8 dual port 4 Gbps FC HBAs SAS (4x6Gbps) FC (8 Gbps) FC (4 Gbps) Priced Storage Configuration Components Priced Storage Configuration: 8 4 Gbps dual port FC HBAs IBM Storwize V7000 (2 nodes) Each V7000 node includes: 8 GB cache (16 GB total) 4 8 Gbps FC front-end connections (8 total, 8 used) 2 4x6 Gbps SAS backend connections (4 total, 2 used 1 per node) 2 24 port Fibre Channel Brocade switches each with 8 ports enabled and 8 SFPs 1 V7000 Expansion Enclosure 18 200 GB Solid State Devices (SSDs)