Home Page for the UPC-E

Similar documents
USR-K2 Setting Protocol V1.0

REPLACING A PEERLINK NETWORK WITH 2572-A / 2572-B ETHERNET

EGW1-IA3-MB User s Manual

Using the Console System

MRD-310 MRD G Cellular Modem / Router Web configuration reference guide. Web configuration reference guide

PRELIMINARY DESCRIPTION

Wireshark Lab: DHCP SOLUTION

Lab Assignment 3 for ECE374

Business Data Networks and Security 10th Edition by Panko Test Bank

A2005/7 System Control Protocol

Appendix A. DeviceNet Explicit Messages

SC/CSE 3213 Winter Sebastian Magierowski York University CSE 3213, W13 L8: TCP/IP. Outline. Forwarding over network and data link layers

Configure IP SLA Tracking for IPv4 Static Routes on an SG550XG Switch

Command Manual Network Protocol. Table of Contents

Project Editor 1.2 User s Guide

PRELIMINARY DESCRIPTION. (*)Coil (Hex) 0x00A1 0x00A2 0x00A3

DHCP and DDNS Services

B.Sc. (Hons.) Computer Science with Network Security B.Eng. (Hons) Telecommunications B.Sc. (Hons) Business Information Systems

BIET EtherNet Interface

CIS-331 Fall 2014 Exam 1 Name: Total of 109 Points Version 1

HPE IMC UAM 802.1X Authentication and ACL Based Access Control Configuration Examples

AlliedView -EMS QoS MANAGER USER S GUIDE

CIS-331 Spring 2016 Exam 1 Name: Total of 109 Points Version 1

GPS NTP TIME SERVER Rack Version V2

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

CONTROLLER INFORMATION SHEET

Exploring TCP and UDP based on Kurose and Ross (Computer Networking: A Top-Down Approach) May 15, 2018

Gateway Ascii Command Protocol

ECE 358 Project 3 Encapsulation and Network Utilities

Savvius Insight Initial Configuration

CAS & CAS UL. Modbus RTU Data Client. (Hardware and Software Solutions) Manual

Winsonic MODBUS Remote IO user manual Rev. 1.0

Programming Book for 6809 Microprocessor Kit

Procedure Note: The research steps for this lab are not included in this procedure.

PRELIMINARY DESCRIPTION

Contact Ethernet Converter module Installation and programming reference

Application Rules - Allows the users to add or modify or remove Custom ruleset for firewall settings.

Module : ServerIron ADX Packet Capture

Modbus Register Map: InRow ACRD60x / ACRC60x

SIM2 C3XLUMIS HOST RS-232C and TCP/IP Control Specifications

Micro Module Shutter. Micro Module Shutter

Ethernet Routing Switch 5000 Series Software Release 6.2.3

CSC 546: Client/Server Fundamentals. Fall Major client/server protocols

Omni Flow Computer Master Driver v1.x Omni Flow Computer Master Modicon Compatible Driver 1.x

Q U E S T I O N 3 In the current version of IP (IPv4), the use of TCP and UDP headers differ in which of the following ways?

PM130 Powermeters Reference Guide ASCII Communications Protocol

Technical Specification. Third Party Control Protocol. AV Revolution

Lab 2. All datagrams related to favicon.ico had been ignored. Diagram 1. Diagram 2

XPort Direct+ Embedded Serial-to-Ethernet Device Server User Guide

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed September Rev 1.6

CIS-331 Final Exam Spring 2018 Total of 120 Points. Version 1

Port Forwarding Setup (RTA1025W Rev2)

ECE 428 Internet Protocols (Network Layer: Layer 3)

Lab Exercise UDP. Objective. Requirements. Step 1: Capture a Trace

Sim Bank Scheduler introduces: 1. Overview

DRT-205C M-Bus Protocol V1.1

MODEL IR5500 Infrared Open Path Gas Detector HART Field Device Specification

Local Area Networks; Ethernet

Fundamentals of Computer Networking AE6382

ECE 461 Internetworking Fall Quiz 1

LiteStation2 LiteStation5 User s Guide

IPv6. IPv4 & IPv6 Header Comparison. Types of IPv6 Addresses. IPv6 Address Scope. IPv6 Header. IPv4 Header. Link-Local

Review of Important Networking Concepts

SwitchLinc 2-Wire Dimmer (RF Only) (2474DWH - Dev 0x01 / Sub 0x24)

User Manual AMETEK Electronic Systems Protection, Inc. / Technical Support: / espei.com / UM-Remote-Portal-Rev-D

IP Change Notification (DDNS)

Use of the TCP/IP Protocols and the OSI Model in Packet Tracer

Using the Signature Editor

DNP Points List and Implementation

TRP-C37 User s Manual

HP M n Access Point Configuration and Administration Guide

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

Settings Settings

A Simple Network Analyzer Decoding TCP, UDP, DNS and DHCP headers

TCP/IP Converter. EX-9132 Operation Manual for 8051 Series

AP-ENBD User Manual V0.2

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

Web UI Guide. Overview 5-2 Activating Web UI 5-2 Status Screen 5-3 Main Menu 5-3

The trace file is here:

COMPUTER NETWORK. Homework #2. Due Date: April 12, 2017 in class

ADMINISTRATION GUIDE Cisco Small Business 200 Series Smart Switch Administration Guide Release 1.1

Using Diagnostic Tools

Base Station Client Utility

WRE2206. User s Guide. Quick Start Guide. Wireless N300 Range Extender. Default Details. Version 1.00 Edition 1, 01/2015

HART USER GUIDE FOR GASSONIC OBSERVER-H ULTRASONIC GAS LEAK DETECTOR

NBG-416N. Wireless N-lite Home Router. Default Login Details. IMPORTANT! READ CAREFULLY BEFORE USE.

C3X1080 RS-232C CONTROL SPECIFICATIONS

Configuring Traffic Policies

HOME AUTOMATION, INC. Model 93A00-1. Serial Server. User s Manual

SSE232-LE Serial Server- User s Manual

Wireshark Lab: HTTP SOLUTION

Application Protocols and HTTP

User Manual TAP CURIOUS

Protocol Layers & Wireshark TDTS11:COMPUTER NETWORKS AND INTERNET PROTOCOLS

All inputs on module 1 are accessed by removing right hand end cap of screen canister

Rocky Mountain IPv6 Summit April 9, 2008

CIS-331 Exam 2 Spring 2016 Total of 110 Points Version 1

SCA11H OPERATION MODES

XPort Device Server User Guide

Transcription:

Home Page for the UPC-E Provides links to sub pages for setup. Displays UPC-E physical location- named by user. Indicates the operating full scale setting in Horsepower. Present output is shown for HP, KW, and Counts. Indicates status of UDP output, if used. Rev 2 Page 1 of 7

IP, MAC & Info Page Enter physical location of the UPC-E for identification purposes. Shows UPC-E MAC address for network setup. Indicates DEFAULT IP address or manually assigned IP address. If DHCP assigns a different number it will not appear here. The default or assigned number will continue to appear. Rev 2 Page 2 of 7

UPC-E Setup Set the full scale value for the UPC-E in Horsepower. HP is actually entered in tenths of a horsepower with no decimal points. Examples: 4.5 HP = 45, 10 HP = 100, 95 HP = 950, 124.5 HP = 1245, etc. Incorrect entries will be flagged and set to either the low or high limit. Pressing Submit again will clear the error. The range may be set from 4.0 to 125.0 HP (40 to 1250). Response Time averages the load signal and may be set in the increments shown. It is a continuous running average. When done. press Submit to save the values. Notes: 1. Values entered here are default values. They will be saved and loaded as operating values when power is applied or if the submit button is pressed. 2. The full scale range and response time may be externally set as operating values via http or UDP. See UDP and HTTP COMMANDS section. Rev 2 Page 3 of 7

UDP Setup Page Set UDP destination MAC and IP address. Select type of data to send- HP, KW, or counts. HP and KW are sent as a 5 digit integer with implied 2 decimal point precision. For example, a HP output of 2881 is 28.81 HP; 12480 is 124.80 HP. Specify the UDP port. Select the interval to send a packet. If UDP is running, a hex command will cause the UPC-E to send a packet. See UDP COMMAND section. Check Run and then Submit to activate UDP. If Stop is checked and Submit pressed, values will be saved, but UDP will not be active. Rev 2 Page 4 of 7

UPC-E Self Test Page Self Test is used to verify correct network and UPC-E operation. This page will automatically refresh every 5 seconds. It is important to wait until the page has just refreshed before pressing the Start Test button. When activated, the HP, KW, and Count outputs will be frozen at their current values for two seconds, during which time the UPC-E will conduct an internal test. At the end of two seconds. outputs will return to process values. A result value will be displayed as Test Counts when the browser refreshes. Any number between 3570 and 3800 is acceptable. At the end of approximately 10 seconds the test will cancel and Test Counts will return to 0. If Self Test is OK but problems persist, check the UPC-E wiring Rev 2 Page 5 of 7

HTTP Commands To request an output value: Count output ( 0 to 4095, or 12 bit resolution): http://aaa.aaa.aaa.aaa/counts.htm HP and KW will output up to a 5 digit whole number. It is up to the application to put in the decimal point (ie, divide by 100 for xxx.xx) HP output http://aaa.aaa.aaa.aaa/hp.htm KW output: http://aaa.aaa.aaa.aaa/kw.htm Notes: 1. aaa.aaa.aaa.aaa is the IP address of the UPC 2. Do NOT use the 'html' suffix. It must be 'htm' To externally set an operating Full Scale or Response value: To set Full Scale HP (FS HP): http://aaa.aaa.aaa.aaa/user.spi?fshp=value Where value is the FS HP value in tenths. NO DECIMAL POINT. e.g., 4 HP = 40, 120 HP = 1200, 124.5 HP = 1245. Out of range numbers will default to '40' on the low side, and '1250' on the high side. To set the operating response time: http://aaa.aaa.aaa.aaa/user.spi?cresponse=value Where value is from table: 50 ms = 1 100 ms = 2 200 ms = 4 400 ms = 8 800 ms = 16 1 sec = 257 2 sec = 258 4 sec = 260 8 sec = 264 16 sec = 272 All other numbers default to '1', or 50 ms To see the operating Full Scale HP and Response time: http://aaa.aaa.aaa.aaa/user.htm The first number will be the FS HP setting; the second number will be the Response time. Refer to the above table. Rev 2 Page 6 of 7

UDP Commands Notes: 1. Entered values MUST be in Hex. Do NOT send ASCII characters. 2. Hex values have no spaces or punctuation 3. Hex values here are shown in byte blocks for clarity 4. Commands must be sent to port 26482 5. Configure MAC & IP destination settings on the UDP Setup page To trigger a UDP packet output: 1. On UDP Setup page, select None and submit 2. Send hex 01 FE 1E FF 01 00 00 (7 bytes) on port 26482 to trigger packet To externally set an operating Full Scale value: 1. UDP must be running to receive data. 2. Send 02 FD 06 00 XX XX 00 00 ( 8 bytes) Where xx xx is the hex full scale value, least significant byte first. Examples: 100 HP = 1000 decimal = 03 E8 hex Send: 02 FD 06 00 E8 03 00 00 22.5 HP = 225 decimal = 00 E1 hex Send: 02 FD 06 00 E1 00 00 00 ( 8 bytes, NO spaces) ( 8 bytes, NO Spaces) To externally set an operating Response value: 1. UDP must be running to receive data. 2. Send: 02 FD 08 00 XX XX 00 00 ( 8 bytes) Where xx xx is the hex value from the table 50ms= 01 00 100ms= 02 00 200ms= 04 00 400ms= 08 00 800ms= 10 00 1 sec= 01 01 2 sec= 02 01 4 sec= 04 01 8 sec= 08 01 16 sec= 10 01 Example: 50 ms Response = 01 00 Send: 02 FD 08 00 01 00 00 00 ( 8 bytes, NO spaces) 8 seconds Response = 08 01 Send: 02 FD 08 00 08 01 00 00 ( 8 bytes, NO spaces ) Rev 2 Page 7 of 7