BMX DDM Mixed Relay Input/Output module

Similar documents
Twido Programmable Controllers Discrete I/O Modules

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only)

170 ADI VDC - 16 Pt. Discrete Input Module Base

Autoranging True RMS Multimeter User Manual

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

Physical description of the safety modules

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Twido Programmable Controllers

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

BMXMSP0200 PTO module - 2 channels - 4 input - 24 V DC ma - 2 connectors 28 pins

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Zelio Control-modular measurement and control relays 1

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Aim of this chapter This chapter describes the TELEFAST 2 connection and adaptation base: ABE-7CPA11.

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

OPERATING INSTRUCTION

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

Micro automation platform

TSXCTY2A 2 channels counter modules - 40 khz - 30 ma at 24 V DC, 280 ma at 5 V DC

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Technical Note. MECHATROLINK-I Distributed I/O Replacement

VersaMax IP I/O Module

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Model Number Structure

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Modicon TM5 EIO /2012. Modicon TM5. Digital I/O Modules Hardware Guide 04/2012 EIO

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Making Hazardous Operations Safe and Productive

Transistor I/O Link Modules

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

User Manual Digital Input Module

VersaPoint I/O Module

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

BMKC Controller for Parabolic Trough, 8 DI 12 DO 4 AI

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

NO: PH-185 PRODUCT: E3JK Photoelectric Sensors DATE: May 2014 TYPE: Discontinuation Notice

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

Zelio Control - modular measurement and control relays 1 Speed control relays RM35 S

Visualize the actual worksite status! Simple and Intelligent I/O Slave Units.

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Modicon M340 BMX MSP 0200 (PTO) module Unity Pro

Link Master Adapter. Ordering Information. Connect High-Density I/O PLC Modules to 16-Point B7A Modules

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

3 - Interfaces. Contents 0. Interfaces for discrete signals. Selection guide... page 3/2. # Electromechanical interface modules...

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

BMKC Controller for Power Tower, 8 DI 8 DO 2 HSC

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

USER'S MANUAL DCL-650

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

BMXCPS3020H power supply module X V isolated DC -

Despite its ultra-slim design, a CPM2C system can provide up to 192 I/O points!

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

CPU Units with 20 I/O points

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Model Number Structure

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

CUS150M1 Instruction Manual

ACCESS 9340/9360 Meter Input/Output Module

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

Inductive Proximity Sensor

User Guide True RMS Multimeter Extech EX205T

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM35TF V AC

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

User's Guide. Digital Multimeter. Model MN42

PM Series Power Meter

02/11/2015

Transcription:

Modicon M340 Using Unity Pro BMX DDM 16025 35012474 07/2012 BMX DDM 16025 Mixed Relay Input/Output module 22 Subject of this Section This section presents the BMX DDM 16025 module, its characteristics, and explains how it is connected to the sensors and pre-actuators. What Is in This Chapter? This chapter contains the following topics: Topic Page Introduction 188 Characteristics 189 Connecting the Module 193 35012474 07/2012 187

Introduction Function The BMX DDM 16025 module is a 24 VDC discrete module connected via a 20-pin terminal block. It is a positive logic module: its 8 input channels receive current from the sensors (sink). The 8 isolated relay outputs operate either on direct current (24 VDC) or alternating current (24...240 VAC). Illustration 188 35012474 07/2012

Characteristics General Input Characteristics BMX DDM 16025 Module The following table shows the general characteristics of the BMX DDM 16025 and BMX DDM 16025H (see page 28) module inputs: Nominal input values Voltage 24 VDC Current Eight 24 VDC positive logic inputs 3.5 ma Threshold input values At 1 Voltage 11 V Current At 0 Voltage 5 V Current 2 ma for U 11 V < 1.5 ma Sensor supply (including ripple) 19...30 V (possibly up to 34 V, limited to 1 hour/day) Input impedance At nominal U 6.8 kω Response time Typical 4 ms Maximum 7 ms IEC 1131-2 compliance Type 3 Reverse polarity 2-wire / 3-wire proximity sensor compatibility (see Premium and Atrium using Unity Pro, Discrete I/O modules, User manual) Reliability MTBF for continuous operation in hours at ambient temperature (30 C) (86 F) Protected IEC 947-5-2 835 303 Dielectric strength Primary/secondary 1500 V actual, 50 / 60 Hz for 1 min. Resistance of insulation Type of input Paralleling of inputs Between input/output groups 500 VDC >10 MΩ (below 500 VDC) Current sink Sensor voltage: monitoring threshold OK > 18 V Sensor voltage: monitoring response time at 24V (-15%... +20%) Error On appearance On disappearance No < 14 V Power consumption 3.3 V Typical 35 ma Maximum 8 ms < T < 30 ms 1 ms < T < 3 ms 50 ma 35012474 07/2012 189

24 V pre-actuator consumption (excluding load current) Power dissipation Typical Maximum Temperature derating (see Premium and Atrium using Unity Pro, Discrete I/O modules, User manual) for BMX DDM 16025 79 ma 111 ma 3.1 W max. None NOTE: For the BMX DDM 16025H, at 70 C (158 F) the maximum pre-actuator power supply must not exceed 26.4 V. LOSS OF INPUT FUNCTION WARNING Do not operate the BMX DDI 16025H at 70 C (158 F) if the sensor power supply is greater than 29.0 V or less than 21.1 V. Overheating the module can cause the loss of the input function. Failure to follow these instructions can result in death, serious injury, or equipment damage. Input Fuses Internal External None 1 fast blow fuse of 0.5 A for the input group CAUTION LOSS OF INPUT FUNCTION Install the correct rating and type of fuse. Failure to follow these instructions can result in injury or equipment damage. General Output Characteristics BMX DDM 16025 Module The following table shows the general characteristics of the BMX DDM 16025 and BMX DDM 16025H (see page 28) module outputs: Eight 24 VDC/24-240 VAC relay outputs Nominal values Switching direct voltage 24 VDC resistive load Switching direct current 2 A resistive load Switching alternating voltage 220 VAC, Cos Φ = 1 Switching alternating current 2 A, Cos Φ = 1 190 35012474 07/2012

Minimum switching load Voltage / Current 5 VDC / 1 ma. Maximum switching load Voltage 264 VAC / 125 VDC On-line module change (1) 1 x 10 5 cycles (2) 3 x 10 5 cycles Possibility Response time Activation 8 ms Deactivation 10 ms Mechanical service life Number of switching 20 million or more Reliability MTBF for continuous operation in hours at ambient temperature (30 C) (86 F) 835 303 Max. switching frequency Cycles per hour 3 600 Electrical service life Switching voltage / current 200 VAC / 1.5 A, 240 VAC / 1 A, Cos Φ = 0.7 (1) 200 VAC / 0.4 A, 240 VAC / 0.3 A, Cos Φ = 0.7 (2) 200 VAC / 1 A, 240 VAC / 0.5 A, Cos Φ = 0.35 (1) 200 VAC / 0.3 A, 240 VAC / 0.15 A, Cos Φ = 0.35 (2) 200 VAC / 1.5 A, 240 VAC / 1 A, Cos Φ = 0.7 (1) 200 VAC / 0.4 A, 240 VAC / 0.3 A, Cos Φ = 0.7 (2) Noise immunity In noise simulation, 1500 V actual, width 1s and 25 to 60 Hz Power consumption 3.3 V Typical 79 ma 24 V pre-actuator consumption Power dissipation Maximum Typical Maximum 111 ma 36 ma 58 ma 3.1 W max. Dielectric strength Max. voltage 2830 VAC rms / cycles Resistance of insulation Temperature derating (see Premium and Atrium using Unity Pro, Discrete I/O modules, User manual) for BMX DDM 16025 10 MΩ None NOTE: For the BMX DDM 16025H, at 70 C (158 F) the maximum pre-actuator power supply must not exceed 24 VA. 35012474 07/2012 191

LOSS OF OUTPUT FUNCTION WARNING Do not operate the BMX DDI 16025H at 70 C (158 F) if the pre-actuator power supply is greater than 28.8 V or less than 19.2 V. Overheating the module can cause the loss of the input function. Failure to follow these instructions can result in death, serious injury, or equipment damage. Output Fuses Internal External None 1 fast blow fuse of 12 A for the output group LOSS OF INPUT FUNCTION Install the correct rating and type of fuse. CAUTION Failure to follow these instructions can result in injury or equipment damage. DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION OR ARC FLASH Switch off the sensor and pre-actuator voltages before connecting or disconnecting the module. Failure to follow these instructions will result in death or serious injury. 192 35012474 07/2012

Connecting the Module At a Glance The BMX DDM 16025 module is fitted with a removable 20-pin terminal block for the connection of eight input channels and eight isolated relay output channels. o Input Circuit Diagram The following diagram shows the circuit of a direct current input (positive logic). 35012474 07/2012 193

Output Circuit Diagram The following diagram shows the circuit of relay outputs. 194 35012474 07/2012

Module Connection The diagram below shows the connection of the module to the sensors and preactuators. input power supply: 24 VDC output power supply: 24 VDC or 24...240 VAC input fuse: 1 fast blow fuse of 0.5 A output fuse: 1 fast blow fuse of 12 A pre-act: pre-actuator 35012474 07/2012 195

196 35012474 07/2012