DIRIS Digiware. Energy Measurement & Monitoring System. Version 16. Plug & Play metering, monitoring and analysis system

Similar documents
DIRIS Digiware Measurement and monitoring system for electrical installations multi-circuit plug & play

DIRIS Digiware Measurement and monitoring system for electrical installations

DIRIS Digiware. Energy Measurement & Monitoring System. Plug & Play metering, monitoring and analysis system

DIRIS Digiware D and C Communication and control power interfaces

DIRIS Digiware Measurement and monitoring system for electrical installations multi-circuit plug & play

DIRIS Digiware Measurement and monitoring system for electrical installations multi-circuit plug & play

DIRIS Digiware Measurement and monitoring system for electrical installations multi-circuit plug & play

DIRIS B-10 & B-30. Multifunction meters and associated current sensors INSTRUCTION MANUAL. en/diris-b

DIRIS Digiware Measurement and monitoring system for electrical installations multi-circuit plug & play

DIRIS Digiware Power metering and monitoring system for AC and DC electrical installations

DIRIS Digiware Power metering and monitoring system for AC and DC electrical installations

DIRIS A & DIRIS B Power Metering and Monitoring Devices

DIRIS A-30 Multifunction power metering & monitoring device - PMD

DIRIS N300/N600 Network analysers Network quality control and analysis system

DIRIS Digiware DC Measurement and monitoring system for DC electrical installations

DIRIS A. Multifunction measurement units for managing your electrical networks

with Backlight Graphic LCD Screen

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

MIC-2 Multi-instrument DATA SHEET

Metering. Lovato E-1 Socomec E-7. Modular energy (kwh) meters. Lovato E-2 Socomec E-8. Modular multi-meters. Lovato E-3 4 Socomec E-8 9

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

DIRIS N. Electrical network analysis system for quality control of your facilities

UMG 604. UMG 604 Power analyser. Modbus master, Ethernet gateway. Harmonics. Memory 128 MByte. Homepage. Graphic programming.

Increase transparency and process quality Total Energy Monitoring across all levels of production Let s connect. Measuring and monitoring systems

MIC-2 MKII, Multi-instrument DATA SHEET

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

E 1. SPECOM - Network analyser. Content. E.2 Description. E.3 Specom C - Technical data. E.4 Specom M - Technical data. E.5 Data communication

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Easy Config. Configuration tool for ATYS, COUNTIS and DIRIS INSTRUCTION MANUAL. easy-config_software

PQM - Power Quality Monitoring

PQM - Power Quality Monitoring

WM20. Power analyzer for three-phase systems. Benefits. Description

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

MODULAR CIRCUIT MONITORING SYSTEM

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

WEBVIEW Software solution for energy monitoring and analysis

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

DIRIS A. The multi-function measurement range MADE TO MEASURE

DIRIS. The multi-function measurement UL range for managing your electrical networks

Metering. Lovato E-1 Socomec E-7. Modular energy (kwh) meters. Lovato E-2 Socomec E-8. Modular multi-meters. Lovato E-3 4 Socomec E-8 9

UMG 605. UMG 605 Power quality analysers for DIN rails. Flicker. Reporting. Memory 128 MByte.

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

Multifunction Transducer MT440

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

PM800 series. Applications

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

DIRIS A. The multi-function measurement range MADE TO MEASURE

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

Voltage Transducer UMT516 / MT516

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Monitoring various parameters with one power meter!

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

Protection relays.

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PQM - Power Quality Monitoring

Energy Division. Crompton Instruments Integra 1630 Low Profile Digital Metering System

6-Channel power analyser UMG 96RM-E. Operating current and RCM fault current monitoring. Smart Energy & Power Quality Solutions RCM.

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

INTEGRA DIGITAL METERING SYSTEMS

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

SUBJECT TO CHANGE WITHOUT NOTICE

POWER SIMPLY SAVE. Catalogue Catalogue 2017

PMC 530 Series Advanced Multifunction Meter

VMU-C/Y, Em 2 CARLO GAVAZZI. The evolution in Energy Management. Monitoring system for Energy Management. A u t o m a t i o n C o m p o n e n t s

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B B)

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

USER MANUAL 2012 V1.1

Power Meter PowerMonitor 500

Energy Monitoring Solutions

DIGITAL METERING INSTRUMENTS DMG SERIES

FOUR FUNCTIONS ONE SOLUTION

ACUREV 2000 Multi-Circuits Networked Multifunction Power Energy Meter

EngyVolt RV12 and RV15

MDC-20. Maximum Demand predictive Control. Description

DIRIS A. PMD multifunction measurement units for managing your electrical networks

Multifuncion Measuring Device 96x96 mm, connection via CT

DIRIS A. The multifunction multi-measurement station MADE TO MEASURE

Hot pluggable communication modules

HMI software. gems 3100 Multi-Channel Power Meter

Electrical network management. Schneider Electric. EM4200 Technical Datasheet

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

THE NEXT TRANSDUCER GENERATION

Transcription:

DIRIS Digiware Energy Measurement & Monitoring System Plug & Play metering, monitoring and analysis system Automatic configuration of metering parameters Data collection and reporting Version 16

IPD Industrial Products is a proudly Australian owned leading manufacturer & distributor of a wide variety of fuses and isolators, electrical switchgear, industrial controls, enclosures, cable accessories, lighting and energy management for the Australian and New Zealand Industry. IPD traces its beginnings to the General Electric Company Ltd of England, founded in 1886. The history of GEC can be found on our website About Us. During the 20th century, the company integrated the major electrical businesses of GEC, English Electric, Marconi, WT Henley, Elliot Bros and A.E.I to comprise one of the most diverse electrical engineering and manufacturing organisation in the world. In 1956, GEC English Electric opened its operation at Regents Park in Sydney and has a proud history providing employment and training to thousands of people in the Australian electrical industry. Today the business has grown and evolved to become IPD Group Limited and is a 100% Australian owned, managed and operated company. IPD stocks and services and extensive range of low voltage power distribution equipment from Miniature Circuit Breakers, Residual Current Devices and Distribution Boards to Moulded Case Circuit Breaker, Air Circuit Breakers, Transfer Switches and much more. Our distribution boards are of the highest quality with most components supplied by our partners GE and Elsteel, plus some items manufactured in Australia, and all boards are inspected and tested after manufacture. As such we can be certain that our boards meet all regulatory requirements. CONTENTS: Control and Power supply interface Page 5 Voltage measurement modules Page 7 Current measurement modules Page 8 Digiware Bus RJ45 cable Page 11 DIRIS G communication gateways Page 13 DIRIS B-30 power monitoring device Page 18 TE sold current sensors Page 25 TR Split-core current sensors Page 25 TF Flecable current sensors Page 25 RJ12 current sensor connection cable Page 25 Contact us at: Phone: 1300 556 601 or visit us at www.ipdgroup.com.au Email: customerservice@ipdgroup.com.au IPD designs, services and manufactures a large range of products specifically suited to our market. Our engineering team conducts local electrical and mechanical testing ensuring conformity to Australian and International Standards and delivering the highest customer satisfaction. You can find all IPD product catalogues, selection and design software tools, technical source material, AutoCAD blocks, reference, specification and test documentation on our knowledge based website www.ipdgroup.com.au. We welcome you to our business and look forward to being a partner of choice. QR Code Scan the code above with a smartphone to view our Digiware website page IPD Group Ltd. Copyright 2016

Control and Power supply interface Page 5 Voltage measurement modules Page 7 Current measurement modules Page 8 Digiware Bus RJ45 cable Page 11 DIRIS G communication gateways Page 13 DIRIS B-30 power monitoring device Page 18 DIRIS B-30 DIRIS DIGIWARE I TE sold current sensors Page 25 TR Split-core current sensors Page 25 TF Flecable current sensors Page 25 RJ12 current sensor connection cable Page 25

Save Time and Space, Reduce Cost and Improve Accuracy The DIRIS Digiware system is a hub of technological innovations that revolutionises the world of measurement, bringing a high degree of flexibility to installations and making connection and configuration easy. These innovations, together with unrivaled performance in terms of accuracy and functionality, make DIRIS Digiware the most effective solution for metering consumption and monitoring the quality of electrical energy. Power management and optimization For perfect control of your electrical network, DIRIS Digiware allows you to: - analyse consumption, - monitor power quality and electrical events. DIRIS Digiware follows UL and IEC international standards dedicated to power monitoring. Simplified maintenance The electrical energy quality monitoring functions offered by DIRIS Digiware make it easier to anticipate electrical malfunctions. The display fitted on the panel door allows operators to quickly read information, on the tablet. The VERTELIS WEBVIEW software allows site managers to remotely monitor their installation. For new and existing installations The reduced size of the modules, the various current sensor formats and the multiple connection accessories make the DIRIS Digiware system suitable for even the most space-constrained installations. It can be easily integrated into an existing installation. 2 Digiware V16

DIRIS Digiware An energy measurement and monitoring system that revolutionises electrical installations Build your system: 1 display 1 voltage measurement module current measurement modules current sensors A Leader in Energy & Power Management A recognised energy efficiency specialist for 20 years. The creator of the DIRIS. A single point of contact, from the initial quote through to implementation. A tailored support: experts ready to listen and services to make your life easier. A comprehensive solution: from sensors to energy management software including services. A solution adapted for industrial and commercial applications and for infrastructure projects. Digiware V16 3

Advantages of the DIRIS Digiware system Flexible Shared functions Common display. A single voltage reference for the entire system. Single auxiliary power supply. Installation of components close to the load Modules and sensors can be installed at the closest point to the values to be measured. Elimination of hazardous voltage on panel doors. Compact design Compact voltage and current modules (1 to 2 modules). System suited to integration in existing space-constrained installations. Wide choice of current sensors Solid, split-core or rogowski coil. Various sizes and formats. Numerous accessories allow the system to be installed in all panel configurations. Multi-circuit Ability to monitor several outputs via a single current measurement module due to independent current inputs. Accurate Accuracy of measurements guaranteed according to ANSI C12.20 and I EC standard 61557-12: Class 0.5 from 2% to 120% of rated current for the global measurement chain (associated with TE/TF current sensors). Class 0.2 for the meter alone. Cost effective Implementation in a quarter of the time vs existing technologies. Save space in panels. Common voltage measurement functions, display and communication. Up to 30% saving compared to existing metering technology. Plug & Play RJ12 current sensor connection Fast: automatic detection of ratings and verification of current flow direction. Reliable: identification of cables by color-coding and wiring control by the system. Disconnection of the current sensor secondary under load. RJ45 interconnection of modules (Digiware bus) Fast: a single connection, no tools required. Intelligent: allows communication and interaction between various modules. Reliable: ensures auxiliary power supply to modules without the risk of disconnection. Auto-configuration of parameters Network type (single-phase, two-phase three-phase). Load type. Addressing of devices connected to the bus. VERTELIS WEBVIEW: the perfect companion to drive reductions in your energy consumption Energy and facility managers of commercial and industrial sites, Do you want: - to understand your site, buildings & processes? - to reduce your energy consumption, costs & carbon emissions? - to monitor, allocate and sub-bill energy costs? - to implement a corporate green communication? VERTELIS WEBVIEW software is the key tool to implement an organizational energy policy within your company. The software allows you to reduce your energy bills by up to 30%. 4 Digiware V16

DIRIS Digiware D and C control and power supply interfaces DIRIS Digiware display The DIRIS Digiware remote display screens provide: - A local view of the data from the DIRIS Digiware voltage and current modules, - A power supply to the DIRIS Digiware modules. - Access to the data over Ethernet (D-50) or RS485 (D-40) Via an RS485 connection, the DIRIS Digiware D-50 display also acts as a gateway, centralising the data from DIRIS A, DIRIS B and makes this information available over Ethernet. Strong points - High-resolution graphical display. - 24 VDC supply: elimination of hazardous voltage at the panel doors. - Ergonomic and easy to use due to direct access buttons for: - measurement information, - circuit selection. - device configuration. - Centralisation of measurement points: - Circuit selection. - Data view. The DIRIS Digiware D-50 screen is supplied with 24 VDC. Ports D-30 D-40 D-50 Input Input B30/I-4x Digiware Bus Digiware Bus Output RS485 RS485 RS485/Ethernet DIRIS Digiware C-31 interface system For applications without a local display, the DIRIS Digiware C-31 interface centralises all of the system s data. An RS485 Modbus output allows this system to provide all information to VERTELIS WEBVIEW user software (DIRIS G communication gateways are available for communication via Ethernet - Modbus TCP). The DIRIS Digiware C-31 interface is supplied with 24 VDC. References DIRIS Digiware D Part No. DIRIS Digiware D-30 single-point display 48290200 DIRIS Digiware D-40 multi-circuit display with RS485 output 48290199 DIRIS Digiware D-50 multi-point display with Digiware Bus, RS485 Modbus, Ethernet (Modbus TCP) 48290201 DIRIS Digiware C-31 Part No. C-31 system interface 48290101 Digiware V16 5

Build your own system Local or remote data display? Number of circuits to be measured? New or existing installation? Data centralization? Control and Power Supply Interface (24 VDC) VOLTAGE MEASUREMENT MODULE CURRENT MEASUREMENT MODULE OR + + DIRIS Digiware D - With display DIRIS Digiware C - Without display DIRIS Digiware U-x DIRIS Digiware I-3x 3 inputs DIRIS Digiware I-4x 4 inputs DIRIS Digiware I-6x 6 inputs communication gateway CURRENT SENSORS + + DIRIS G - RS485 to Ethernet TE Solid TR Split-core TF Flexible 6 Digiware V16

DIRIS Digiware U Voltage measurement module The DIRIS Dgiware U module measures the reference voltage for the entire system. The Digiware RJ45 bus allows you to measure the voltage as well as supply power to all connected devices. Strong points - 1 single voltage measurement point for the entire system. - A complete, dedicated solution: - for metering, - for voltage monitoring, - for quality analysis of the voltage. - No hazardous voltage at the panel doors. DIRIS Digiware U-X RJ45 cables (Digiware bus) are available; refer to page 11. References U-10 U-20 U-30 Application Metering Monitoring Analysis Multi-measurement U12, U23. U31, V1. V2, V3. f U system. V system Ph/N unbalance Ph/Ph unbalance Power - Quality THDU, THDV, Indivdual harmonics U/ V (up to rank 63) Volage dips, cut-offs and surges (EN50160) Alarms (threshold) History of average values Width/number of modules 18 mm/1 18 mm/1 18 mm /1 Part No. 4829 0105 4829 0106 4829 0102 Why do you need power quality monitoring? - To ensure a continuous power supply. - To lower electricity bills and avoid penalties associated with reactive energy. - To optimize the size of the installation. - To extend the lifetime of equipment (on networks polluted by harmonics). - To identify polluting loads and improve the energy efficiency of the installation. Digiware V16 7

DIRIS Digiware I Current measurement modules DIRIS Digiware I modules DIRIS Digiware I modules measure consumption at the closest point to the loads. The flexibility of these modules allows you to allocate the loads to be measured or to monitor independent current inputs. For example (l-3x): - 1 three phase load, - 3 single phase loads, - 1 split phase load + 1 single phase load. The RJ45 and RJ12 connections allow you to connect modules very quickly and to automatically configure connected current sensors: - communication address, - load type, - sensor type and ratio, - Automatic rating and verification of current flow direction. Wiring errors are also prevented and implementation is simplified. Strong points - RJ45 and RJ12 rapid connection. - Available with 3, 4 or 6 inputs. - Single-circuit or multi-circuit for maximum optimization of the number of products. - Compact format: 1 or 2 modules sized for integration at the closest point to the loads. - A complete, dedicated solution: - for metering, - for power monitoring, - for quality analysis. - Compliant with standard IEC 61557-12, guaranteeing the quality and accuracy of the system: - Class 0.5 from 2% to 120% of rated current for the global measurement chain (associated with TE/TF current sensors), - Class 0.2 for the meter alone. RJ45 cables (Digiware bus) are available; refer to page 11. References Application Metering Monitoring Analysis Monitoring Analysis Metering I-30 I-31 I-33 I-35 I-43 I-45 I-60 I-61 Number of current inputs 3 3 3 3 4 4 6 6 Metering +/- kwh, +/- kvarh, kvah Multi-tariff (8 max.) Load curves Multi-measurement I1,I2,I3, In, P, Q, S, FP P, Q, S, FP per phase Predictive power Current unbalance Phi, cos Phi, tan Phi Power - Quality THDI Individual harmonics I (up to rank 63) Overcurrents Alarms Thresholds Inputs/Outputs 2/2 2/2 History of average values Width/number of modules 18mm/1 18 mm/1 18mm/1 18mm/1 27mm/1,5 27mm/1,5 36mm/2 36mm/2 Part No. 48290110 48290111 48290128 48290130 48290129 48290131 4829 0112 48290113 8 Digiware V16

DIRIS Digiware Measurement and monitoring system for electrical installations Connections DIRIS Digiware D-50 DIRIS Digiware C-31 Power supply DIRIS Digiware C-32 Power supply Digiware BUS Digiware BUS DIRIS Digiware U DIRIS Digiware I-3x Voltage measurement Digiware BUS Current measurement DIRIS Digiware I-45 Current measurement Communication Digiware BUS DIRIS Digiware I-6x RJ9 for DIRIS D-30 (self supply and data) Inputs IPD GROUP LIMITED Outputs Phone: 1300 556 601 Digiware BUS Current measurement Digiware BUS www.ipdgroup.com.au Digiware V16 9

DIRIS Digiware measurement and monitoring system for electrical installations Dimensions: Configuration: Power consumption of devices Components Power Power supplied consumption (W) (W) Power supply P15 230 VAC / 24 VDC 15 Cables 50 metre package 1.5 System interfaces DIRIS Digiware D-50 2 DIRIS Digiware C-31 0.8 Voltage module DIRIS Digiware U-xx 0.72 Current modules DIRIS Digiware I-3x 0.52 DIRIS Digiware I-45 1.125 DIRIS Digiware I-6x 0.7 Repeater DIRIS Digiware C-32 1.5 Rules to set the maximum number of products on the Digiware BUS The total power consumptions by the devices connected to the Digiware BUS must not exceed the power supplied by the 24 VDC supply. The power supply must not exceed 20W. System configuration with P15 power supply (ref: 4829 0120) providing 15W System can include: - 1 display DIRIS Digiware D-50 (2W) - 1 voltage module DIRIS Digiware U-xx (0.72W) - 50 meter cable (1.5W) and - 20 current modules DIRIS Digiware I-3x (20 x 0.52 = 10.4W) Total power = 14.62W or - 9 current modules DIRIS Digiware I-45x (9 x 1.125 = 10.125W) Total power = 14.345W. System configuration with a 24 VDC power supply providing a maximum of 20W System can include: 1 display DIRIS Digiware D-50 (2W) 1 voltage module DIRIS Digiware U-xx (0.72W) 50 meter cable (1.5W) and 30 current modules DIRIS Digiware I-3x (30 x 0.52 = 15.6W) Total power = 19.82W or 14 current modules DIRIS Digiware I-45x (14 x 1.125 = 15.72W) Total power = 19.97W. Repeater When the power consumption is over 20 W or the distance exceeds 100 m, a DIRIS Digiware C-32 repeater is required in a DIRIS Digiware system, maximum 2 repeaters can be used. 10 Digiware V16

Technical characteristics Electrical characteristics DIRIS Digiware C-31 Input voltage Connection P15 power supply Measurement characteristics 24VDC ± 20 % - 20W max Removable screw terminal, 2 positions, 0.2 to 2.5 mm² stranded or solid cable Characteristics: 230VAC/24VDC - 0.63 A - 15W Modular format - Dimensions (H x L): 90 x 25 mm Energy and power measurement Accuracy Class 0.2 DIRIS Digiware alone Active energy and Class 0.5 with TE or TF current sensors active power Class 1 with TR current sensors Reactive energy accuracy Class 2 with TE, TR or TF current sensors Power factor measurement Accuracy Class 0.5 with TE or TF current sensors Class 1 with TR current sensors Voltage measurement - DIRIS Digiware U Network characteristics measured 50-300VAC (Ph/N) - 87-520VAC (Ph/Ph) - CAT III Frequency range 45... 65Hz Frequency accuracy Class 0.02 Network type Single-phase / Two-phase / Two-phase with neutral / Three-phase / Three-phase with neutral Measurement by Primary: 400 000VAC voltage transformer Secondary: 60, 100, 110, 173, 190VAC Input consumption < 0.1VA Permanent overload 300 VAC Ph/N Voltage measurement accuracy Class 0.2 Connection Removable screw terminal, 4 positions, 0.2 to 2.5 mm² stranded or solid cable Current measurement - DIRIS Digiware I Number of current inputs I-3x:3 / I-43:4 / I-45:4 / I-6x:6 Associated current sensors Solid TE, split-core TR, flexible TF current sensors Current measurement Class 0.2 DIRIS Digiware alone accuracy Class 0.5 with TE or TF current sensors Class 1 with TR current sensors Connection Specific SOCOMEC cable with RJ12 connectors Inputs - DIRIS Digiware I-45 Number of inputs 2 Type / Power supply Non insulated input, internal polarisation 12 VDC max, 1mA Input functions Logic status or pulse meter Connection Removable screw terminal, 0.14 to 1.5 mm² stranded or solid cable Outputs - DIRIS Digiware I-45 Number of outputs 2 Relay type 230VAC ± 15% - 1A Function Configurable alarm (current, power) on threshold overruns or remote controlled status Connection Removable screw terminal, 0.2 to 2.5 mm² stranded or solid cable References DIRIS Digiware Part No. D-50 Multi-point display - Ethernet, RS485 48290201 D-40 Multi-point display - RS485 48290199 C-31 System interface 48290101 C-32 Repeater 48290103 U-10 Metering 48290105 U-20 Monitoring 48290106 U-30 Analysis 48290102 I-30 Metering - 3 current inputs 48290110 I-31 Metering + load curve - 3 current inputs 48290111 I-33 Monitoring - 3 current inputs 48290128 I-35 Analysis - 3 current inputs 48290130 I-43 Monitoring - 4 current inputs 48290129 I-45 Analysis 2 inputs / 2 outputs - 4 current inputs 48290131 I-60 Metering - 6 current inputs 48290112 I-61 Metering + load curve - 6 current inputs 48290113 Communication characteristics Digiware BUS Function Type of cable RS485 Connection type Protocol Speed Function Location USB Protocol Function Location Connection Connection between DIRIS Digiware modules Specific SOCOMEC cable with RJ45 connectors 2... 3 half duplex wires Modbus RTU 1200... 115 200 bauds Configuration and data transmission Single-point on DIRIS Digiware C Modbus RTU over USB Configuration of DIRIS Digiware U and I modules On each DIRIS Digiware U and I measuring module B-type micro USB connector Mechanical characteristics Types of casing Modular for DIN-rail or back plate mounting Casing degree of protection IP20 / IK06 Front face degree of protection IP40 (panel face with modular mounting) / IK06 Environment characteristics Operating temperature -10... +70 C Storage temperature -25... +70 C Operating humidity 55 C / 97% relative humidity Operating altitude 2000m DIRIS Digiware D-50 characteristics Mechanical characteristics Screen type Capacitive touch-screen technology, 10 keys Screen resolution 350 x 160 pixels Front face degree of protection IP65 Communication Ethernet RJ45 10/100Mbs RJ45 Digiware RS485 2-3 wires USB Electrical characteristics Power supply 24VDC +10% / -20% Consumption 2VA Environment characteristics Storage temperature -20... +70 C Operating temperature -10... +55 C Humidity 95% at 40 C Installation category - degree of pollution CAT III, 2 Modbus TCP gateway function Control and power supply interface function Modbus RTU communication function Updating via B-type micro USB connector Power supply Part No. P15 230VAC/24VDC 15W power supply 48290120 Digiware connection cables Part No. RJ45 cables for 0.10m length 48290181 BUS Digiware 0.50m length 48290182 1m length 48290183 2m length 48290184 5m length 48290186 10m length 48290187 50m + 50 connectors 48290185 Termination for Digiware BUS (fitted on C-31 and D-50) 48290180 USB configuration cable 48290050 Single-point display Reference DIRIS D-30(1) Single-point display for DIRIS Digiware I-45 48290200 (1) DIRIS D-30 display characteristics. Digiware V16 11

Introduction to DIRIS Digiware D DIRIS Digiware D-30 Single-point display. DIRIS Digiware D-40 / D-50 Multipoint display. DIRIS Digiware D-30 is a local single-point display connected to the measuring unit DIRIS B-30 or DIRIS Digiware I-45 via an RJ9 cable (1.50m cable Part No.: 48290280-3m cable: 48290281). The screen is powered through the RJ9 cable. DIRIS D-30 WIRING DIRIS D-40 WIRING The DIRIS Digiware D-40 display is a slave product of the RS485 bus and links to the DIRIS Digiware bus. DIRIS D-50 WIRING A DIRIS Digiware D-50 display is a master product of the RS485 bus and links to the DIRIS Digiware bus. It is used like an Ethernet gateway. The Ethernet port is for: Using the Ethernet network in ModbusTCP to share all the data taken from the counters and measuring units connected to its Digiware and RS485 ports. Displaying on DIRIS Digiware D-50 the data taken from remote products connected to the local Ethernet network. 12 Digiware V16

DIRIS G Communication gateway With DIRIS G communication gateways, all information from meters and measurement devices communicating via the RS485 bus are centralised in a single device and then made available on the Ethernet network via the modbus TCP. The gateway has an embedded WEBVIEW web server, allowing real time monitoring of electrical values and analysis of consumption data. Strong points - WEBVIEW web server embedded in the gateway, view of data via an Internet browser. - Automatic addressing and detection of devices. - Automatic recording and storage of measurements and consumption data. - Automatic sending of alarm emails (SMTP). - Automatic clock synchronisation (SNTP). DIRIS G-30/G-50 RS485 modbus/ Ethernet Selection guide DIRIS G gateways Part No. DIRIS G-30 RS485 / Ethernet - WEBVIEW Power Monitoring 48290300 DIRIS G-50 RS485 / Ethernet - WEBVIEW Power & Energy Monitoring 48290302 DIRIS O optional modules Part No. DIRIS O-iod 2 digital inputs / 2 digital outputs 48290030 DIRIS O-ioa 2 analogue inputs/2 analogue outputs, 4-20 ma 48290031 DIRIS O-it 3 temperature inputs PT 100 / PT 1000 48290032 Accessories Part No. USB configuration cable 48290050 WEBVIEW Functions Hosted on Gateway (32 devices max.) Power Monitor DIRIS G-30 Monitoring - Real time measurement - Alarms Power & Energy Monitor DIRIS G-50 Monitoring - Real time measurement - Alarms Display - Measurement history - Consumptions Digiware V16 13

Function: VERTELIS WEBVIEW Web server embedded in the DIRIS G communication gateway The WEBVIEW web server embedded in DIRIS G gateways enables measurement monitoring up to 32 devices and displays the energy consumptions by usage. Pre-set alarms defined by the user can sent by e-mail. User can access WEBVIEW via a web browser on a PC or a tablet. Power Monitoring Monitor - Automatic detection of connected devices. - Up to 32 counting and measurement devices. - Measurements of voltage, current, power, power factor, harmonic distortion rate (THD) and harmonics per rank. - Total & partial energy consumption per load. - Input/output status. - Synchronisation of device clocks. Alarm - Alarms for overloads, events & input status changes. - Display of alarm history. - Sorting by type, nature, criticality or state. - Alarm displayed on the main page. - Sending of alarm by email (SMTP). Power & Energy Monitoring View - Historical measurements and consumption (one year of data). - Distribution of consumption by usage and by utility (water, gas, electricity, etc.). - Export of consumption data in CSV format. Power & Energy Monitoring also includes Monitor and Alarm functions. Real time views Alarm history Consumption history Single-gateway architecture: centralisation of data on a single gateway Strong points - Centralisation of data from RS485 Modbus devices. - WEBVIEW embedded web server. - Compatible with DIRIS Digiware and DIRIS A. Multi-gateway architecture: centralisation of data on several cascading or parallel gateways Strong points - Suitable for all network types. - Multi-gateway communication. - Local view of all devices linked to the connected gateways on a DIRIS Digiware D-50 display. - WEBVIEW embedded web server. - Compatible with DIRIS Digiware and DIRIS A. 14 Digiware V16

DIRIS G Connection Power supply Input supplied by the product Input with external power supply RS485 Dimensions (mm) DIRIS G-30 / G-50 Digiware V16 15

DIRIS G Communication gateway Optional modules: The optional modules, which have a modular format, are fitted on the DIRIS G; they are used to extend its functionalities in terms of inputs/outputs and communication modes. DIRIS O-iod 2 digital inputs/output module DIRIS O-ioa 2 analogue inputs/output module DIRIS O-it 3 temperature inputs module Maximum 4 optional modules can be connected to a DIRIS G gateway to ensure control/command functions. Terminals of optional DIRIS O modules. Power supply of optional modules DIRIS O-iod and O-ioa DIRIS O-iod DIRIS O-ioa DIRIS O-it Dimensions of optional modules A DIRIS O-iod DIRIS O-ioa DIRIS O-it 45mm 16 Digiware V16

DIRIS G Communication gateways Technical characteristics Mechanical characteristics Casing type Case degree of protection Front degree of protection Weight Modular for DIN-rail or back plate mounting IP20 / IK06 IP40 (panel face with modular mounting) / IK08 DIRIS G-30, G-50 = 190g Electrical characteristics Power supply AC voltage Frequency Consumption Battery 110-230 VAC ±15% (Ph/N or Ph/Ph) Cat III 50/60 Hz 6 VA CR 1220 3 V lithium button cell battery Input Number 1 Type / Power supply Optocoupler internal polarisation (12 VDC ± 10 %) or external polarisation (10-30 VDC ± 10%) Input function Logic status, pulse meter or synchronisation pulse status Communication characteristics DIRIS G Link Connection type Protocol Speed Function Ethernet Link Protocol Clock SNTP protocol SMTP protocol Function USB Connection type Protocol Function Connection RS485 2... 3 half duplex wires Modbus RTU 2400... 115200 bauds Communication with PMDs and meters Ethernet 10/100 base-t, 2 RJ45 bases with integrated switch Modbus TCP (port 502), Modbus RTU over TCP (port 503), HTTP, SMTP, SNTP, DHCP Internal Gateway time updating from an NTP server. Connected PMDs time updating. Sending of alarm emails from the gateway Configuration of the gateway, connected PMDs and meters Access to the WEBVIEW web server, data centralisation USB 2 (Easy Config software required) Modbus RTU over USB Configuration of the gateway, connected PMDs and meters B-type micro USB connector Memory capacity Historical of consumptions (memory capacity extension of meters and monitoring devices) 1 year (1-hour period) Electrical values 2 months (10-minute period) Number of events Alarms: 1000 Network quality as per EN 50160:1000 Environment characteristics Operating temperature Storage temperature Operating humidity -10... +70 C -25... +85 C 55 C / 97% relative humidity Digiware V16 17

DIRIS B-30 Power monitoring device Function: The DIRIS B-30 is a power monitoring device in a modular format that communicates via RS485. The 4 RJ12 independent current inputs of the device allow it to manage several types and number of circuits: for example, 4 single-phase loads or 1 three-phase load + 1 single-phase load. The DIRIS B-30 is connected to current sensors (RJ12 connection) that are suitable for all types of installation: solid TE, split-core TR, and flexible TF current sensors. The solution for: - Industry - Building - Infrastructure - Local authority Strong points - Plug & Play - Class 0.5 in accordance with IEC 61557-12 - Multi-circuit - Communication Advantages: Plug & Play A rapid RJ12 connection makes wiring easy and reliable and prevents wiring errors. Automatically addressing and configuring the product (communication address, load type, type and ratio of current sensor) allow you to simplify implementation and to save time. References Class 0.5 in accordance with IEC 61557-12 - Class 0.2 for the meter alone. - Class 0.5 from 2% to 120% of nominal current for the global measurement chain (associated with TE current sensors). Multi-circuit - 4 current measurement inputs allow you to configure multiple circuits in order to optimize the number of measurement devices per installation. Communication - The DIRIS B-30 can be connected to: - a remote DIRIS D-30 screen for displaying measurement and metering data. - a DIRIS G gateway for centralisation and communication of data via RS485 and Ethernet. - optional modules to communicate in BACnet IP, BACnet MSTP and PROFIBUS DP protocol. Digital or analogue input/ output modules can also be connected. DIRIS B-30 monitoring devices Part No. DIRIS B-30 RS485 - Modbus communication 48290000 DIRIS O optional modules Part No. DIRIS O-iod 2 digital inputs / 2 digital outputs 48290030 DIRIS O-ioa 2 analogue inputs/2 analogue outputs 4-20mA 48290031 DIRIS O-it 3 temperature inputs PT 100/PT 1000 48290032 DIRIS O-m RS485 Modbus communication 48290033 DIRIS O-p PROFIBUS communication 48290034 DIRIS O-b/ip BACnet IP communication 48290035 DIRIS O-b/mstp BACnet MSTP communication 48290036 Conformity to standards: - IEC 61557-12 - EN 50160 - ISO 14025 Accessories Part No. DIRIS D-30 - Single-point display 48290200 RJ9 cable for DIRIS D-30 display - 1.5 m 48290280 RJ9 cable for DIRIS D-30 display - 3 m 48290281 DIRIS B-30 sealing cover for I/O terminals 48290049 USB configuration cable 48290050 18 Digiware V16

DIRIS B-30 Power monitoring device Functions: Multi-measurement - Currents - I1, I2, I3, In, Isystem - Voltages & frequency - V1, V2, V3, VN, Vsystem, U12, U23, U31, Usystem, f - Power - P1, P2, P3, ΣP, Q1, Q2, Q3, ΣQ, S1, S2, S3, ΣS - Predictive power ΣP, ΣQ, ΣS - Power factor - PF1, PF2, PF3, ΣPF - Cos φ & tan φ - Instantaneous values per phase Metering - Active energy: +/- kwh - Reactive energy: +/- kvarh - Apparent energy: kvah DIRIS B-30 display Quality - Voltage Unbalance - Vdir, Vinv, Vhom, Udir, Uinv, Unba, Vnba, Vnb, Unb - Current unbalance - Idir, Iinv, Ihom, Inba, Inb - Total harmonic distortion - Currents THDi1, THDi2, THDi3,THDiN - Phase-to-neutral voltage THDv1, THDv2, THDv3 - Phase-to-phase voltage THDu12, THDu23, THDu31 - Individual harmonics up to rank 63 - Currents: I1h, I2h, I3h, INh - Phase-to-neutral voltage: V1h, V2h, V3h - Phase-to-phase voltage: U12h, U23h, U31h - Active (according to EN 50160) - Dips, interruptions, swells Load curves and history logs - Active, reactive and apparent power. - Currents, voltages and frequency. Alarms - Alarms for all electrical values, events and input status changes, possibility of boolean combination. Communication - DIRIS B-30 RS: RS485 Modbus, - Optional modules: RS485, BACnet IP, BACnet MSTP, PROFIBUS DPV1. Inputs - 2 digital inputs - Supply by the DIRIS B-30 or external supply - Function: logic status, circuit breaker status, pulse meter or synchronisation pulse. DIRIS D-30 Dimmensions Connection Optional modules: Optional module DIRIS B-30 Digiware V16 19

DIRIS B-30 Power monitoring device Optional modules The optional modules, which have a modular format, are fitted on the DIRIS B-30; they are used to extend its functionalities in terms of inputs/outputs and communication modes. Optional modules (4 max).* - Digital inputs/outputs - Analogue inputs/outputs - Temperature inputs - Communication protocols * maximum 4 optional modules with maximum 1 temperature module and 1 communication module (Modbus, PROFIBUS, BACnet IP or BACnet MSTP). DIRIS O-iod - 2 digital inputs centralises the metering pulses or the input status changes of the auxiliary contacts. - 2 digital outputs can be connected to configurable alarms warning of exceeded thresholds (power, current, etc.) or can be piloted remotely. DIRIS O-m - Provides a second RS485 Modbus communication port to the DIRIS B-30 for simultaneous sending of information via RS485 to two supervision stations. DIRIS O-p DIRIS O-ioa - 2 inputs (4-20 ma) centralise analogue sensors (pressure, humidity, temperature, etc.) - 2 outputs (4/-20 ma) report the measurements (power, currents, etc.) to PLCs. - Adds a PROFIBUS DPV1 communication port to the DIRIS B-30. DIRIS O-b/ip - Adds a BACnet IP communication port to the DIRIS B-30. DIRIS O-it - 3 temperature inputs to be connected to PT100 or PT1000 sensors. - Ambient air temperature. DIRIS O-b/mstp - Adds a BACnet MSTP communication port to the DIRIS B-30. Accessories DIRIS B-30 sealing cover - Prevents access to the cabling of the monitoring device. USB configuration cable (2m) - Advanced configuration of DIRIS B-30 gateways can be achieved using the EASY CONFIG software via Ethernet or direct USB connection. 20 Digiware V16

DIRIS B-30 Power monitoring device DIRIS B-30 Connections Current measurement Self supply Separate power supply Easy connection of the power supply from the measurement terminal (specific terminals) Voltage measurement and auxiliary power supply 2 inputs supplied by the product 2 inputs with external power supply RS485 RJ9 for DIRIS D-30 (self-supply and data) Terminals of optional DIRIS O modules: Optional module power supply DIRIS O-iod DIRIS O-ioa DIRIS O-p IPD GROUP LIMITED Phone: 1300 556 601 DIRIS O-it DIRIS O-m RS485 DIRIS O-b/ip DIRIS O-b/mstp www.ipdgroup.com.au Digiware V16 21

DIRIS B-30 Power monitoring device DIRIS D-30 display characteristics DIRIS B-30 characteristics Electrical characteristics Auxiliary power supply AC voltage Frequency Consumption Connection Measurement characteristics 110-230VAC ±15 % (Ph/N ou Ph/Ph) Cat III 50/60 Hz < 2VA without display < 6VA with display Removable spring-cage terminal, 2 x 2 positions, 0.5... 2.5 mm² solid cable or 0.25... 1.5 mm² standed cable with ferrule Energy and power measurement Accuracy Class 0.2 DIRIS B-30 alone Active energy and Class 0.5 with TE or TF current sensors active power Class 1 with TR current sensors Reactive energy accuracy Class 2 with TE, TR or TF current sensors Power factor measurement Accuracy Class 0.5 with TE or TF current sensors Class 1 with TR current sensors Voltage measurement Network characteristics measured 50-300VAC (Ph/N) - 87-520VAC (Ph/Ph) - CAT III Frequency range 45... 65Hz Frequency accuracy Class 0.02 Network type Single-phase / Two-phase / Two-phase with neutral / Three-phase / Three-phase with neutral Measurement by Primary: 400 000 VAC voltage transformer Secondary: 60, 100, 110, 173, 190 VAC Input consumption < 0.1 VA Permanent overload 300VAC Ph/N Voltage measurement accuracy Class 0.2 Connection Removable spring-cage terminal, 2 x 6 positions, 0.5... 2.5 mm² solid cable or 0.25. 1.5 mm² standed cable with ferrule Current measurement Number of current inputs 4 Associated current sensors Solid TE, split-core TR, flexible TF current sensors Accuracy Class 0.2 DIRIS B-30 alone Class 0.5 with TE or TF current sensors Class 1 with TR current sensors Connection RJ12 connectors with specific SOCOMEC cable Input characteristics Number 2 Type / Power supply Optocoupler internal polarisation (12 VDC ± 10 %) or external polarisation (10-30 VDC ± 10%) Input function Logic status, pulse meter or synchronisation pulse status (input 1) Communication characteristics DIRIS B-30 RS485 Link Connection type Protocol Speed USB Environment characteristics Operating temperature Storage temperature Operating humidity Operating altitude Vibration RS485 2... 3 half duplex wires Modbus RTU 1200... 115200 bauds DIRIS B-30 RS485 configuration -10... +70 C -25... +85 C 55 C / 97% relative humidity 2000 m 1G from 10Hz to 100Hz Mechanical characteristics Screen type Capacitive touch-screen technology, 10 keys Screen resolution 350 x 160 pixels Single product connection RJ9 Micro-USB Degree of protection Self-supply and data Updating IP65 (front face) Electrical characteristics Power supply 24 VDC + 10% / -20% Consumption 2 VA Environment Storage temperature ( C) -20/+55 Operating temperature ( C) -20/+55 Humidity 95% to 40 C Installation category CAT III Degree of pollution 2 DIRIS O optional modules characteristics Power supply (1) AC voltage 110-230 VAC ±15 % Frequency 50/60 Hz (1) No power supply on DIRIS O-it DIRIS O-iod - 2 digital inputs/2 digital outputs Number of inputs 2 per optional modules - max. 4 optional modules Type Optocoupler internal polarisation (12 VDC ± 10 %) or external polarisation (10-30 VDC ± 10%) Function Logic status or pulse meter Number of outputs 2 per optional modules - max. 4 optional modules Type Relay / 230VAC ±15% - 1A Function Configurable alarm (current, power) on threshold overruns or remote controlled status Inputs/Outputs Removable screw terminal, 4 positions, 0.14 to 1.5 mm² stranded or solid cable connection DIRIS O-ioa - 2 analogue inputs/2 analogue outputs Number of inputs 2 per optional modules - max. 4 optional modules Type 4-20 ma Function Connection of analogue sensors (pressure, humidity, temperature.) Number of outputs 2 per optional modules - max. 4 optional modules Type 4-20 ma Function Transmission of measurement image (current, power.) to PLCs DIRIS O-it - 3 temperature inputs Number of inputs 3 external inputs + 1 measurement for ambient temperature Dynamic -20 C to 150 C Type PT100 or PT1000 Function inputs 1, 2 and 3 Temperature measurement DIRIS O-m - RS485 communication Link RS485 2... 3 half duplex wires Protocol Modbus RTU Speed 1200... 115200 bauds Connection Removable screw terminal, 3 positions, 0.14 to 1.5 mm² stranded or solid cable DIRIS O-p - PROFIBUS communication Protocol PROFIBUS DPV1 DIRIS O-b/ip - BACnet IP communication Protocol BACnet IP Speed 10... 100 Mbit/s DIRIS O-b/mstp - BACnet MSTP communication Protocol BACnet MSTP Speed 9600 76800 bauds 22 Digiware V16

DIRIS B-30 Power monitoring device Dimensions (mm): DIRIS B-30 DIRIS O optional modules DIRIS O optional modules A DIRIS O-iod - DIRIS O-ioa - DIRIS O-it 45mm DIRIS O-m - DIRIS O-p - DIRIS O-b/ip - DIRIS O-b/mstp 54mm Associated current sensors Various types of current sensors can be connected to the DIRIS Digiware: Solid TE, split-core TR, flexible TF current sensors. This range of sensors can be adapted to all types of new or existing installations. A rapid RJ12 connection makes wiring easy and reliable and prevents wiring errors. The DIRIS B-30 automatically recognises the sensor size and type. This guarantees the overall accuracy of the DIRIS B-30 + current sensor measurement chain. TE solid current sensors DIRIS B-30 or DIRIS DIGIWARE I TR Splic-core current sensors TF flexible current sensors Digiware V16 23

TE, TR and TF Current sensors Current sensors associated to DIGIWARE and DIRIS B-30. TE solid current sensors TR Splic-core current sensors TF flexible current sensors Function: TE, TR and TF current sensor ranges can be connected to DIRIS Digiware and DIRIS B-30 via a rapid RJ12 connection. Various accessories are available to allow the installation of sensors in all panel configurations. Plug & Play - A rapid RJ12 connection makes wiring easy and reliable and prevents wiring errors. This also allows automatic detection of the sensor type and size/transformation ratio. - Mounting orientation of current sensors is indifferent. Selection guide Accuracy as per standard IEC 61557-12 - Class 0.5 from 2% to 120% of nominal current for the global measurement chain (associated with TE or TF current sensors). - Class 1 from 2% to 120% of nominal current for the global measurement chain (associated with TR current sensors). Suitable for any installation Dimensions of the range allow: - New installation: a range of solid TE sensors adapted to the pitch of protective devices. - Existing installations: a range of split-core TR sensors for existing sites. - Existing space-constrained installations with high-intensity currents: a range of flexible TF current sensors (Rogowski). TE TR TF Current sensors Solid current sensors Split-core current sensors Flexible current sensors Nominal current range (A) 5 2000 25 600 150 6000 Functions: TE Range - Solid current sensors. - Plug & Play RJ12 connection. - High accuracy over the whole operating range. - 7 models with ratings from 5 to 2000A that are adapted to the pitch of protective devices (18/25/35/45/55/90 mm). - A 5A/RJ12 adapter for use with TC 5A current transformers in the DIRIS Digiware and DIRIS B-30 ranges. - Accessories for back-plate, DIN-rail, cable or bar mounting. TR Range - Split-core current sensors. - Plug & Play RJ12 connection. - High accuracy over the whole operating range. - 4 models with ratings from 25 to 600A. - Apertures from 10 to 36mm. TF Range - Split-core current sensors. - Plug & Play RJ12 connection. - High accuracy over the whole operating range. - 3 models with different ratings (from 150 to 6000 A). - Apertures from 55 to 300mm. 24 Digiware V16

TE, TR and TF Current sensors TE solid current sensors Suitable for new installations - Match the pitch of protective devices. TE-18 TE-25 TE-35 TE-45 TE-55 TE-90 Nominal current from from from from from from from 5 to 20A 25 to 63A 40 to 160A 63 to 250A 160 to 630A 400 to 1000A 600 to 2000A Connection RJ12 RJ12 RJ12 RJ12 RJ12 RJ12 RJ12 Part No. 48290500 48290501 48290502 48290503 48290504 48290505 48290506 For loads greater than 1000 A, use the the 5 A / RJ12 adapter associated with 5A secondary CTs. Staggered assembly Linear assembly TR split-core current sensors Suitable for existing installations. TF Flexible (Rogowski) current sensors TR-10 TR-16 TR-24 TR-36 Nominal current from from from from 25 to 75A 32 to 100A 63 to 200A 200 to 600A Connection RJ12 RJ12 RJ12 RJ12 Part No. 48290551 48290552 48290553 48290554 Suitable for existing installations with space restrictions or with high-intensity currents. TF-55 TF-120 TF-300 Nominal current from from from 150 to 600A 500 to 2000A 1600 to 6000A Connection RJ12 RJ12 RJ12 Part No. 48290570 48290571 48290572 Cable length (m) RJ12 connection 0,1 0,2 0,3 0,5 1 2 5 10 50 m + 50 cables connectors No. of cables Part No. Part No. Part No. Part No. Part No. Part No. Part No. Part No. Part No. 1 - - - - - - 48290602 48290603 48290601 3 48290580 48290581 48290582 48290595 48290583 48290584 - - - 4 48290585 48290586 48290587 48290596 48290588 48290589 - - - 6 48290590 48290591 48290592 48290597 48290593 48290594 - - - Digiware V16 25

TE and TR Dimensions (mm) TE - Solid current sensors TE-25 / TE-35 / TE-45 / TE-55 / TE-90 TE - Solid current sensors TE-18 Model Nominal current range Pitch H x W x D Ø (A) (mm) (mm) (mm) TE-18 5... 63 18 45 x 28 x 20 8,6 TR - Split-core current sensors TR-10 / TR-16 / TR-24 / TR-36 Model Nominal current range Pitch H x W x D F T (A) (mm) (mm) (mm) TE-25 40... 160 25 65 x 25 x 32.5 13.5 x 13.5 17.5 TE-35 63 250 35 71 x 35 x 32.5 21 x 21 17,5 TE-45 160 630 45 86 x 45 x 32.5 31 x 31 19,5 TE-55 400... 1000 55 100 x 55 x 32.5 41 x 41 21,5 TE-90 600 2000 90 126 x 90 x 19.7 64 x 64 - TF - Flexible current sensors TF-55 Model Nominal current range H x W x D Ø (A) (mm) (mm) A W C TR-10 25 75 71 x 25 x 39 10 58 14,5 26 TR-16 32 100 74 x 30 x 42 16 61 19 31 TR-24 63 200 95 x 45 x 44 24 72 22 34 TR-36 200 600 111 x 57 x 42 36 82 34 40,5 Model Nominal current range Ø L = (A) loop loop length TF-55 150... 600 55 172 TF - Flexible current sensors TF-120 / TF-300 Model Nominal current range Ø L = (A) loop loop length TF-120 500... 2000 120 376 Tf-300 1600... 6000 300 942 26 Digiware V16

TE, TR and TF Current sensors Connections DIRIS B-30 or DIRIS DIGIWARE I TF Flexible (Rogowski) current sensors TE Range Linear mounting (circuit breaker pitch) TE-25 / TE-35 / TE-45 / TE-55 / TE-90 Staggered mounting TE-18 / TE-35 / TE-45 / TE-55 Cable mounting TR Range Cable mounting Din-rail mounting Back-plate mounting Bar mounting IF Range Cable mounting Bar mounting Accessories Adapter for 5A CT - This adapter is for use with a 5A CT with output terminals on the DIRIS Digiware and DIRIS B-30. For use with standard 5A current sensors for > 1000A measurement requirements. - Dimensions are identical to TE-18. Mounting accessories Mounting accessories provided with TE current sensors TE-35 TE-45 Fixing TE-18 TE-25 TE-55 DIN-rail or back plate 1 part Coupling link - Associated with the TE range, this accessory is for inter-connecting the sensors when linear or staggered mounted. DIN-rail 2 parts 2 parts Back plate 4 parts 4 parts Sealable cover - Using a sealable cover guarantees the immunity of the sensor connection on TE/TR/TF current sensors. Bar 2 parts Digiware V16 27

DARWIN CAIRNS BRISBANE PERTH NEWCASTLE SYDNEY ADELAIDE MELBOURNE AUCKLAND HOBART QR Code Scan the code above with a smartphone to view the full IPD product range National Customer Support Centre Tel: 1300 556 601 Fax: 1300 550 187 Email: customerservice@ipdgroup.com.au www.ipdgroup.com.au