ReNEW LED Retrofit Assembly QUICK START GUIDE

Similar documents
Springtree Spatial Wash COB RGBW

ETC Installation Manual

TB-1230 QW. User Manual Please read the instruc on carefully before use

DarkFX Spot 670 User Manual English

Springtree Spatial Wash COB WW

V2 LED SOFTLIGHT USER GUIDE

ETC Quick Guide. Source Four LED Profile

RGBW 3x4 Brick & 10x4 Batten USER MANUAL

SPOT MOVING HEAD M1S150W USER MANUAL. For safety, please read this user manual carefully before initial use.

LED Slimline PAR RGBW 7x8W

User Manual INTRODUCTION SAFETY INFORMATION BACK PANEL DIAGRAM. Please read the instructions carefully and before use.

LED SPIDER MOVING HEAD LIGHT

TourPro RGBAW Stagebar USER MANUAL

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

Robot Light V2. User Manual

ZEP - 644SXCW 640SX - LED 150 W. Profile spot. Type: Profile spot Source: LED 150 W Optics: 16 to 35 zoom Colour temperature: Cool White

ZEP - 641SXCW 640SX - LED 150 W. Profile spot. Type: Profile spot Source: LED 150 W Optics: 11 to 26 zoom Colour temperature: Cool White.

Eternal Lighting. Premier150 Spot. User Manual

CW-WW LEDWash USER MANUAL

ETC Installation Guide

VBAR 270. User Manual. Version 1.2

dynamic white par manual

Power LED Beam 56 Narrow

50W/100W LED Alu. User Manual. Code: ELUM041-50W - (5600K) Code: ELUM041A - 100W (5600K) Code: ELUM041C - 50W - (3200K) Code: ELUM041D - 100W (3200K)

Gobo Projector XP 80W

xbrick Full-Colour 16 3W LED floodlight user manual

MONOPRICE. ShowPony 12-Watt LED Derby FX Light (RGBW) User's Manual P/N

TECHNICAL DATA. V-PIX Quad Bar. Product code CL-VPIX-4-40 Light colour Full spectrum 8 / 480 (see above)

PHX 250W LED PROFILE SPOT 250 Watt LED

Type: Source: Optics: Profile spot Colour temperature: Features Optical Multi-function double gate: Very long-life lamp source: Shutter gate:

MATRIX 25E. Matrix Beam Wash, ArtNet, RDM. User manual. Please read the instructions carefully before use

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

Operation Manual. Celeb 400 DMX LED

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

SP-1500 DMX MK II Strobe

ETC Desire Quick Guide

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

ZEP - 664SX WW 660SX - LED 300 W. Profile spot. Type: Profile spot Source: LED 300 W Optics: 16 to 35 zoom Colour temperature: Warm white

ETC Desire Quick Guide

DPX-620III 6-Ch. dimmer pack. user manual

FOS PAR Innovative 1

Precision DMX Manual

LED Accu Penta 9x12W RGBWAU

i.shine 1136 RGBW Color Stainer CN USER MANUAL

Endura 1Q120 RGBW COB Exterior Fixture

Revo 120. User Manual

Ostar Eye K18. Beam and Kaleido Effects. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

LED DANCING FLOOR User Manual

L1.2 & L2.2. LED Studio Light OPERATING INSTRUCTIONS

LEDMH100 USER MANUAL

up to lm, CRI > 90, + - Green Correction Function, Cpulse special flicker free management for HD and UHD cameras

D'Artagnan - 934SNXE 900SNX W HID. Profile spot

i.shine 3148 RGBW Color Stainer XP USER MANUAL

PROFESSIONAL SHOW LIGHT

Now with Picture Memory

Lumina Matrix USER MANUAL

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

User Manual Charter Street Los Angeles CA

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

Quasar 15K Operating Manual

LED PAR56 Order Code: P56-151

LED Pixel Bar. Model No. PIXBAR12x3, PIXBAR12x8,PIXBAR12x12 USER MANUAL. For safety, please read this user manual carefully before initial use.

SUPER LEDF10HP DATASHEET

GLX LED STAGE 4 MANUAL GLS-4 LED STAGE 4. owners manual

LED Profile 150W 3200K. User manual. LED spotlight

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

KasBar COB Tri 5. 5x15w 3in1 COB LEDs (RGB) USER MANUAL

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

PRODUCT SPECIFICATIONS

RevueLED 150 Profile 3200K 26 LED spotlight. user manual

Blitzer Strobe. User Manual. Order code: EQLED366

LED W RGBA User Manual

Operation Manual. Celeb 400Q DMX LED

LITEDIMMER PLus. dc200 DUO. ac400 DUO USER GUIDE

SUPER LEDF6 DATASHEET

LED Theater Spot K. User manual. LED spotlight

TRANSCENSION Show Control

Irideon FPZ. User Manual. Rev A

Super LED F4.7VW Vari-White

Edition Notes. Edition Notes. Trademarks CHAUVET is a registered trademark of CHAUVET & Sons Inc. (d/b/a CHAUVET or

A double yoke enables the fixture to be operated in several positions.

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

K9 Lights USER MANUAL

Super LED F6 VW Vari-White

PAR56 10MM UV LED PAR. user manual

USER MANUAL. 17R Spot\Beam Light. Please Read Over This Manual Before Operating The Light Fixture

XC-42 OWNERS MANUAL COMPACT PORTABLE DIMMER. Revision /12/2007. Lightronics Inc. 509 Central Drive Virginia Beach, VA

USER MANUAL. 10R Spot\Beam Light. Please Read Over This Manual Before Operating The Light Fixture

LED Commander 16/2 DMX controller. user manual

Four high-output, slim-profile RGB tri-color LED par lights with included IR6 remote, power and DMX cables, and custom carry bag

TOKISTAR LIGHTING INSTRUCTION MANUAL

Page 1 of 6 FXLD157FRP6I2 LED FIXTURE Version 0.2 OWNERS MANUAL 3/31/2017

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

U-150 Integrated Amplifier User s guide

Operation Manual. Imara S100 & S60 DMX. Imara S100 DMX Yoke Mount. Imara S100 DMX Pole-Op

JAB Series Light. User Manual (IP60 Protection)

IMPACT Order code: EQLED79

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

Transcription:

ReNEW LED Retrofit Assembly QUICK START GUIDE This document provides installation and setup procedures for the PRG ReNEW LED Retrofit Assembly. For complete operating instructions, refer to the ReNEW LED Retrofit Assembly User Manual available at www.prg.com/ product/renew For technical assistance, contact PRG RH+A. PRG RH+A 539 Temple Hill Road New Windsor, NY 12553-5533 1-800-748-6562 www.prg.com/product/renew 1. IMPORTANT SAFETY INSTRUCTIONS + Keep these instructions. + Heed all warnings. + Follow all instructions. + Do not block any of the fixture s ventilation openings. + Do not operate at temperatures above 40 C (104 F). + Do not install the fixture near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. + Do not install the fixture on or near a flammable surface. + Do not operate the fixture with a damaged power lead. If the power lead (cordset) is damaged, it must be replaced. + Do not operate the fixture if glass lens is deeply scratched or cracked. Damaged lenses must be replaced. + Use the fixture in dry locations only, where humidity does not exceed 90 percent (non-condensing). The fixture is not intended for outdoor use. It is rated IP20. + Mount and support the fixture only by the primary suspension holes in the yoke. + Suspend the fixture from a suitable structure using only hardware rated for the weight of the fixture. + In addition to primary suspension, attach a safety cable to the fixture housing. An appropriate attachment point (hole) is provided in the fixture s housing. + Disconnect the fixture from power and DMX control and allow to cool before performing any cleaning or maintenance. WARNING! Do not use an AC power cord that is nicked, frayed or damaged in any way. An approved replacement AC power cord may be obtained from PRG, LLC. Consult the User Manual for available configurations and part numbers. AVERTISSEMENT! Ne pas utiliser un cordon d'alimentation qui est entaillé, usé ou endommagé de quelque façon. Un remplacement cordon d'alimentation approuvé peut être obtenu à partir de PRG, LLC. Consultez le manuel de l'utilisateur pour les configurations disponibles et les numéros de pièce. 1

2. OVERVIEW The ReNEW LED Retrofit Assembly is intended for use with a Source Four ellipsoidal spotlight manufactured by Electronic Theatre Controls (ETC). The LED light engine of the ReNEW Assembly replaces the tungsten light source of the original ETC Source Four spotlight. INCLUDED ITEMS MAJOR COMPONENTS & CONTROLS Head Assembly Interface Panel Yoke ReNEW LED Retrofit Assembly 9-Volt Battery Port AC Line Cord Power Cable Locking Knob Safety Cable 55.9802.1000 Note: An ETC Source Four Lens & Shutter Assembly is not included, and must be installed separately. See next page. Menu Display Comm LED INTERFACE PANEL DMX IN DMX THRU DMX Input DMX Thru AC IN MODE CANCEL EDIT SET COMM AC THRU Menu Controls AC Input 100-240 VAC 50/60 Hz 10A MAX. PRESS TO POWER LAMP 100-240 VAC 50/60 Hz 7.5A MAX. AC Thru Figure 1: Components Overview 2

3. INSTALLATION Attach Source Four Lens & Shutter Assembly Step 1. Insert ETC Source Four Lens & Shutter Assembly (not included) into ReNEW housing (Figure 2). Step 2. Turn Source Four assembly clockwise. Tighten set screw and locking knob to secure in place. Locking Knob Source Four Lens & Shutter Assembly ReNEW Assembly Set Screw Mount on Pipe Figure 2: Attaching Source Four Lens Assembly Step 1. Install clamp (not included) on ReNEW yoke (Figure 3). Step 2. Carefully lift ReNEW Assembly into mounting position on pipe. Step 3. Attach safety cable to yoke, wrap around pipe, and clip onto head assembly as shown. Step 4. Rotate head assembly to desired position and secure in place by tightening two yoke locking knobs. Clamp (not included) At least one (1) Safety Cable MUST be used for all hanging installations and may be required by local codes. Note: Source Four Lens Assembly not shown. Locking Knob (2) Figure 3: Standard Hanging Configuration 3

Connect Data and Power The ReNEW LED Retrofit Assembly requires standard AC power 100-240 VAC, 50/60 Hz, 2.5A maximum. The ReNEW interface panel provides one Neutrik powercon connector for power input (AC IN) and one for power pass-through (AC THRU). Use the provided AC Line Cord Cable to connect power. The ReNEW Assembly provides two, 5-pin XLR connectors for DMX IN and DMX THRU (out) applications. DMX IN requires a 5-pin, female XLR connector and DMX THRU requires a 5-pin, male XLR connector. Observe the following guidelines when setting up the system: + A maximum of 32 DMX devices may be connected in any one DMX512 data link. However, note that the maximum limit applies to the "daisy-chain" only. Your system or console may require fewer devices on a single data link path. Consult your console documentation for more information. + Three additional ReNEW Assemblies may be connected to the AC THRU connector (4 total). A special Jumper Cable is available for this purpose. (Refer to the ReNEW LED Retrofit Assembly User Manual.) Remember to use a DMX terminator at the end of each DMX signal chain. This improves signal quality and reduces the chance of incorrect or spurious control data. WARNING: The ReNEW Assembly has no power on/off switch. Turn off the mains circuit breaker or unplug from wall socket before connecting or disconnecting the Neutrik powercon connector. To connect power and data: Step 1. Connect DMX data cable from console to DMX IN connector at first ReNEW Assembly in chain (Figure 4). Step 2. If required, connect additional DMX data cables from DMX THRU connectors to DMX IN connectors of remaining ReNEW Assemblies in chain. Step 3. At last ReNEW Assembly in chain, install male termination connector at DMX THRU connector. (Devices on the same DMX512 chain may not function properly without termination.) Step 4. Connect AC Line Cord Cable to AC IN connector at first ReNEW Assembly in chain. Step 5. If required, connect AC jumper cables from AC THRU connectors to AC IN connectors of remaining ReNEW Assemblies in chain. A limit of four (4) ReNEW Assemblies can be connected using AC jumper cables. Step 6. Dress and secure all cables. DMX512 In DMX512 Thru DMX512 Thru Termination Connector Power Thru Power Thru Power In Figure 4: Daisy Chain Configuration 4

4. QUICK SETUP Power Up Apply power to the ReNEW LED Retrofit Assembly by turning on mains circuit breaker. (The unit has no power on/off switch.) When AC power is applied, the ReNEW menu interface will display a start-up splash screen before loading the default menu for the last mode set. (All settings are retained while power is off.) Comm LED Operation A green Comm LED, located at the ReNEW interface panel, provides feedback during operation: + Solid - Valid DMX received. + Slow Blink - DMX is expected but not received. + No Light - No DMX expected, no DMX received (manual modes only). + Fast Blink - An internal error has occurred. The Comm LED goes out after 10 minutes of operation if no errors are present. Menu Overview The menu system is used to configure and operate the ReNEW Assembly. The menu display and controls are located on the interface panel (Figure 5). Navigation Mode The initial mode is Navigation. In this mode, left (<) and right (>) arrows are displayed around the current menu title, such as "< DMX Address >". + Pressing the minus [-] or plus [+] buttons moves to the next or previous menu item. + Pressing the [Mode/Cancel] button will return to the Mode menu. MODE CANCEL < DMX Address > 001 EDIT SET COMM Edit Mode Pressing the [Edit/Set] button switches the interface to Edit mode. In this Figure 5: Menu Display and Controls Detail mode, plus (+) and minus (-) symbols are displayed to the left and right of the editable value (such as "- 001 +"). (However, this is not true for the Mode menu, where up/down buttons are displayed.) + Pressing the plus [+] or minus [-] buttons will increment and decrement the value. + Pressing the [Edit/Set] button again sets the displayed value and returns to the Navigation mode. + Pressing the [Mode/Cancel] button while in Edit mode restores the original value before editing began and returns to the Navigation mode. Focus Mode PRESS TO POWER LAMP Use Focus mode to turn on the lamp momentarily for the purpose of aiming and focusing the light. + Enter Focus mode from anywhere in the menu by pressing [Edit/Set] and minus [-] buttons together. The ReNEW Assembly will output 100% intensity for five minutes. Time can be added or removed from the timer with the plus [+] and minus [-] buttons. 5

DMX Operation The ReNEW LED Retrofit Assembly is factory set for DMX operation. It closely emulates an 8-bit tungsten fixture, and can be used as one out of the box. There are several configuration changes you may want to make when setting up the ReNEW Assembly, including changing the address, setting the unit for 16-bit intensity control, or changing the dimming curve or response time. When the ReNEW Assembly is first powered on, it should begin at the DMX Address screen: < DMX Address > 001 (If this is not the case, refer to CHANGING THE MODE on the next page.) Set DMX address by pressing [Edit/Set]. The menu now allows you to edit the DMX address: DMX Address - 001 + Use [+] and [-] buttons to set the desired DMX address, then press [Edit/Set] again to save the value < DMX Address > 015 Table 1: DMX Menus Menu Menu Description Setting Setting Description DMX Address DMX Mode DMX Fault DMX Dim Curve Sets the ReNEW Assembly s DMX address. Sets the ReNEW Assembly s DMX footprint (also known as DMX personality). This provides a trade-off between control and the amount of space occupied on the DMX universe. Defines the ReNEW Assembly s output state upon loss of DMX signal. Adjusts the ReNEW Assembly s dimmer curve. 1-512 DMX512 value 1ch 8b inten * 2ch 16b inten 3ch 16b+fx Last Look * 0% Intensity 100% Intensity Tungsten * Linear 8-bit intensity control, like a conventional dimmer. 16-bit intensity control, for finer control and smoother operation. 16-bit intensity control with additional macro channel settings for automated strobe and fade. Maintains the last DMX command received until valid DMX is restored. Intensity goes to 0% upon loss of DMX. Intensity goes to 100% upon loss of DMX. Power-law response, similar to a tungsten fixture. Linear output. DMX Smoothing Applies a smoothing filter to the DMX input, adding some delay to make the output response appear more natural. None Medium Maximum * No filter, instant response. Moderate filtering, reduces flicker induced by step changes to DMX input. Heavy filtering, slows output response by a significant amount. * default setting 6

Changing the Mode If the ReNEW Assembly is in a different mode than what is desired, it can be changed by pressing the [Mode/Cancel] button (multiple times if necessary) until the Mode menu appears: ----- Mode ----- DMX Control Select the desired mode from the list by pressing the [+] and [-] buttons. Once the correct mode is shown, press [Edit/Set] to enter that mode. + DMX Control - Sets the ReNEW Assembly to be controlled by DMX512. (This is the default mode.) + Manual Intensity - Sets the ReNEW Assembly s brightness level. + Manual Effects - Configures effects such as pulse, fade, and strobe. + Utilities - Used to access special functions and software information. Manual Intensity Mode For installations that need a constant, set amount of light, use the Manual Intensity mode. Change the mode to "Man. Intensity" as described in CHANGING THE MODE above. Once in Manual Intensity mode, the display will show the intensity setting: Intensity 100% Use the [Edit/Set] button to enter editing mode, and the plus [+] and minus [-] buttons to adjust the output level: Intensity - 100% + Manual Effects Mode If a strobe or fade effect is desired, use the Manual Effects mode. There are three types of fade effects, as well as a strobe and a random strobe. Adjustable settings include the effect type, effect rate, and effect maximum intensity. Each effect will repeat until the mode or effect type is changed. + Pulse On - Sawtooth waveform. Fast turn-on with gradual fade out. + Pulse Off - Reverse sawtooth waveform. Fast turn-off with gradual fade up. + Fade - Gradual fade up, then gradual fade out. + Fast Strobe - Strobe effect. + Random - Random strobe effect. Refer to the ReNEW LED Retrofit Assembly User Manual for a detailed description of the Manual Effects menu system. Note: When using multiple ReNEW Assemblies, synchronization between the units is not possible in manual mode. If synchronization is desired, use DMX control. 7

Configuration Using 9-Volt Battery The ReNEW LED Retrofit Assembly provides a method for configuring the menu system while disconnected from the main AC power source. This is accomplished using a 9-volt battery which is inserted into a port located on the side of the unit. This can be used to set the DMX address before installation, etc. To configure unit using battery power: Step Step Step 1. At side-port, insert and hold 9-volt battery (Figure 6). (Polarity does not matter. The battery can be inserted in any orientation.) Battery must be held in place to supply power. 2. Configure menu options as required. 3. Remove battery. 9-Volt Battery Figure 6: 9-Volt Battery Port ReNEW LED Retrofit Assembly Quick Start Guide Version as of: December 15, 2014 PRG document number: 02.9830.0002 539 Temple Hill Road 2014 Production Resource Group, LLC. All Rights Reserved. New Windsor, NY 12553-5533