haze-gard i The objective standard for a clear view Global communication Reliable and Precise

Similar documents
BYK-mac. Total color impression of effect finishes. Ergonomic design and easy operation. Reliable readings at any time

micro-gloss The new intelligence in gloss measurement Brilliant color display: easy to read - easy to use Auto diagnosis: Standard OK - Calibration OK

Gloss. micro-gloss. Efficient gloss measurement makes your QC faster. In the lab, in production, at the customer s...

Gloss. micro-gloss. Efficient gloss measurement makes your QC faster. In the lab, in production, at the customer s...

Novo-Haze TX Transmission Hazemeter

Color Data Software CM-S100w. Professional Edition Lite Edition

Thermo Scientific Spectronic 200 Visible Spectrophotometer. The perfect tool. for routine measurements

haze-gard plus Best.-Nr Best.-Nr haze-gard plus Cat. No Cat. No haze-gard plus N de code 4725 N de code 4726 haze-gard plus

CHROMA METER CR-400/410 CR-410 CR-400

Inspection Technology Europe BV Allied NDT Engineers

Color Data Software CM-S100w. Professional Edition Lite Edition 13

Diving into a new dimension: Quality meets efficiency

AUTOMATIC MICRO-HARDNESS TESTER ISOSCAN HV1 OD

Precise & Affordable

The Autopol VI Automatic Polarimeter

Belec IN-SPECT New Compact Spectrometer for Metal Analysis with latest 5GSO System

Elcometer 480. Glossmeters

AUTOMATIC HARDNESS TESTER ISOSCAN HV50 AC

LIGHT SOURCE Quartz-iodine lamp 12V-20W.

CI-150 Series. Airborne Particle Counters

1523/1524. Reference Thermometers. Measure, graph and record three sensor types with one tool

XA 4Y Analytical Balances

Introduction BALANCES. Laboratory Balances. Appearance Color Physical Properties Balances. Technical Service Index

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system

Luminaire testing device

ASM Series. Advanced Signal Multi-scanner. Functional signal multi-scanner adding flexibility to your calibration needs

Multi-functional precision thermometer CTR3000

NANOCOLOR VIS II and NANOCOLOR UV /VIS II

X-Rite MA98 Portable Multi-Angle Spectrophotometers

Programmable Dual-Range DC Power Supplies 9170 & 9180 series

Programmable Dual-Range DC Power Supplies 9170B & 9180B Series

Specification for temperature sensor calibration setup

MAVOSPEC BASE. Spectral Light Meter For Practitioners. {Filename} Klaus-Peter Richter

QC20-W wireless ballbar system description and specifications

REFO Glossmeters for superior Gloss Quality

XENOTEST 220/440. Light Exposure and Weathering Testing Instruments

Precision hand-held pressure indicator Model CPH6400

Application of MULTISPEED and MULTISPEED Automatic testers

DMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7

MICROSCAN AC. Description AUTOMATIC MICRO-HARDNESS TESTER

NOVO-GLOSS. Flex 60. Operating Instructions. English

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

Cost-effective System for Inline Coating Evaluation in R2R Processes. Craig Johnson Business Developement Manager

USB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software

Elcometer 456 Integral Coating Thickness Gauge

powered by TAS Technology

CATS MOBILE DEVICE TESTER

Penetration: Penetrometer PNR 12 (Bitumen)

A New Perspective On Things

QualiGloss Series Gloss Meter

ProLab 1. ProLab 1000: ph for the professional. ph Meter ProLab 1000: Superior technique in a classy metal body. Precise measurements

DMC-1400 Documenting Multi-function Calibrator

Pneumatic precision pressure controller Model CPC6000

UV-VIS Spectrophotometer

Product Information Version 3.0. ZEISS ZEN 2 core Smart. Precise. Open. Imaging Software Simplified.

tibase Intelligent data management for titration

Pinnacle Series interfaces: RS232C, USB and LAN. Pinnacle balances are unique in offering three interfaces for external communication.

Precision pressure indicator 1- or 2-channel version Model CPG2500

OHD S.A. Equipos y Sistemas de Monitoreo Ambiental

JDSU Optical Handheld Testers. Family of light sources, power meters, attenuators, loss test sets, return loss meters, and optical talksets

specification vates colorimeter

Particle size. Welcome to the. next generation. Smarter particle sizing. detailed specification sheets from

Temperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD

CHROMA METER CR-400/410 CR-410 CR-400

Scan Station 100 Plus. The one-button easy solution for capturing, sending, and sharing your documents electronically. Scan. Share

Temperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD

ANALYTICAL BALANCES. 4,0038 g PROFESSIONAL MEASURING

The. benefits. of the. FilmStation. Dry. Film. Imager. can be. explained. in very. little. space...

DL1000 DURABILITY & LUBRICITY TEST SYSTEM

Efficient - Safe - User-friendly

Variable Zoom Lenses* USB High-Resolution Camera

Industrial pressure controller Model CPC4000

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

Multiskan Sky Microplate Spectrophotometer

High-end pressure controller Model CPC8000

Micro calibration bath Models CTB , CTB

Smart_Color_Premium. State-of-the-art Spectrophotometer for Optical Industries

SERIES E L I T - -J. Authorized distributor in Australia:

Getting Started. Read Me First. series. Photo Printer

AS X2 Analytical Balances

Temperature dry-well calibrator Models CTD , CTD

TRIBOMETERS MICRO-MACRO TRIBOLOGY TESTING

Lab Determining Data Storage Capacity

DAILY LINAC QA BEAM QA

The Need for Measurement

The DDM 2909 Automatic Density Meter

Agilent 2100 Bioanalyzer System & Applications Site Preparation Checklist

Water Analysis. NANOCOLOR heating blocks MACHEREY-NAGEL. Heating blocks of the future

Pneumatic precision pressure controller Model CPC6000

Customer Responsibilities

MPI TS2500-RF 200 mm Fully Automated Probe System For RF Production Test Measurements

RetroSign GRX-7 1. MEASUREMENT PARAMETERS:

Hand-Held Thermometer Model CTH 6200

Nano DSC and MCDSC. Site Preparation Guide

Technical Information Memobase Plus CYZ71D

20/60 20/60/85 GLOSSMETER DOI METER HAZE METER GONIOPHOTOMETER

Application Note. Measuring the Geometric Attributes of Your Products AN

USTER TESTER 5-C800. The filament yarn inspection system. Technical Data

Transcription:

haze-gard i The objective standard for a clear view Transparent products can have a milky or fuzzy appearance dependent on its light scattering behaviour. The haze-gard i quantifies the visual perception with objective measurement criteria: Total transmittance Transmission haze Clarity haze-gard i controls complete transparency by taking only one reading. Global communication Haze and transmittance control according to international standard methods with one unit: ASTM D1003 - illuminants C and A Non-compensated method ISO 13468 - illuminant D65 Compensated method haze-gard i displays all results simultaneously - well prepared for any customer specification. Reliable and Precise With state-of-the-art optics and LED technology the haze-gard i delivers an unprecedented performance: Reference beam, self-diagnosis and enclosed optics. LED light source assures long-term stable results for many years: 10 year warranty on the lamp life! Automatic, long-term calibration - operator friendly and safe. REF Superior repeatability and inter-instrument agreement are guaranteed.

Smart and Fast The new touch display is designed to be intuitive and easy to use for any task: Large touch display in color. Symbols to select a menu function. Dedicated measurement button. Footswitch allows hands-free operation. Open and Flexible The open measurement compartment let s you work freely to analyze any sample size: Open design for small and large specimens. Fast change and positioning of samples. No influence of ambient light. Versatile sample holder for films and sheets. Sample holders for taber abrasion test and cuvettes for liquids optional. Customized sample holders can be easily attached. Horizontal or vertical set-up Sample handling in any position is convenient and allows you highest flexibility.

Onboard analysis Measurement data can be analyzed and saved in projects directly in the haze-gard i for efficient work management: Large instrument memory (5000 readings). Complete statistics with averaging, min / max, standard deviation. Limit input for different product specifications with colorful Pass/Fail analysis. Professional connection Data transfer can be performed in all sorts of ways to support you in routine lab work: Direct data transfer via USB-port to PC. Direct LAN connection to your network for further analysis in Laboratory Information Management Systems (LIMS). Save data on a USB-stick. smart-lab haze - data analysis software Whatever the task, smart-lab haze will do it for you. From simple data tables of single test series to trend reports over time - anything is possible. Define your product specifications in standard management by setting up product groups with Pass/Fail limits. Measure your products online and get instant QC reports displayed: Data table with statistic and line graph including Pass/Fail coloring. Manage your lab work in projects to show production process stability using trend reports. Transfer product specs and projects to haze-gard i and vice versa for daily work management.

In compliance with: Standards ASTM D1003, D1044 ISO 13468, 14782 Ordering Information Technical Specifications Cat. No. Description 4775 haze-gard i Illuminants CIE-C, CIE-A (ASTM D1003) Comes complete with: Hazemeter with sample holder Clarity calibration standard Traceable certificate Foot switch and power cord USB-cable and LAN-cable smart-lab haze software on CD with License Key (2 licenses) Operating manual Training Extended Warranty: see pages about Technical Service Free 1x preventive maintenance service during warranty period Note: smart-chart licence fee for more than two installations is quantity dependent. Please contact your local BYK-Gardner representative. System requirements: Operating system: Windows 7 SP1 or 8.1 Microsoft.NET Framework 4 Hardware: Core 2 Duo, 2.2 GHz, i7 recommendet, or equivalent Memory: 4 GB RAM, 8 GB recommendet Hard-disk capacity: min. 300 MB Monitor resolution: 1280 x 1024 pixel or higher Disk drive: CD-ROM or DVD drive Interface: free USB-port or network access Spectral Response Geometry Measurement Area Sample Port CIE-D65 (ISO 13468, ISO 14782) CIE luminosity function y 0 / diffuse ø 18 mm (0.7 in) ø 25.4 mm (1.0 in) Measurement Range 0 100 % Repeatability Reproducibility Memory Interface Power Supply Operating Temperature Storage Temperature Dimensions Weight ± 0.1 units (standard deviation) ± 0.4 units (standard deviation) 5000 readings LAN, USB 2.0, additional front USBport for memory stick 115/230V self adapting +10 to 40 C (+50 to 104 F) 0 to 50 C (+32 to 122 F) 62 x 33 x 22 cm (24 x 13 x 9 in) 18 kg (40 lbs) Training BYK-Gardner offers you more than just an instrument. We train you in the operation of the haze-gard i and data analysis. A half-day training course for haze-gard i operation and smart-lab haze software is included.

Versatile sample holders for specific needs Easy replacement of holders for different applications. Special holder for very thin films Ordering Information Accessories Cat. No. Description 4784 Thin Film Holder, for 4775 Special holder for very thin films 4785 Taber Abrasion Holder, for 4775 For evaluation of abrasion resistance with the hazemeter 4786 Cuvette Table, for 4775 For measurement of liquids 6180 Cuvette for Liquids, 2.5 mm Path length 2.5 mm, edge length 50 mm 6182 Cuvette for Liquids, 5 mm Path length 5 mm, edge length 50 mm 6183 Cuvette for Liquids, 10 mm Path length 10 mm, edge length 50 mm 6189 Cuvette for Liquids, 20 mm Path length 20 mm, edge length 50 mm 4865 BYKWARE smart-lab haze Software for professional analysis and documentation Space Holder Space Holder The measurement of haze is used to determine abrasion resistance of transparent materials. The haze-gard i Abrasion Holder facilitates positioning of the abraded area in the measurement beam. Liquids are best measured using cuvettes and the cuvette table.

Please refer to section Preventive Maintenance Ordering Information Accessories Cat. No. Description 4776 Clarity Calibration Standard, for 4775 Replacement Standard for clarity, certificate included 4777 Clarity Reference Standard, for 4775 Test standard for checking purposes, certificate included 4790 Haze Standard 1, for 4775 Approx. 1% haze, for checking purposes, certificate included 4791 Haze Standard 5, for 4775 Approx. 5% haze, for checking purposes, certificate included 4792 Haze Standard 10, for 4775 Approx. 10% haze, for checking purposes, certificate included 4793 Haze Standard 20, for 4775 Approx. 20% haze, for checking purposes, certificate included 4794 Haze Standard 30, for 4775 Approx. 30% haze, for checking purposes, certificate included 4795 Haze Standard Set, for 4775 Set of 5 pieces in hard box, certificate included 4778 Transmittance Standard 10, for 4775 Approx. 10% total transmittance, for checking purposes, certificate included 4779 Transmittance Standard 30, for 4775 Approx. 30% total transmittance, for checking purposes, certificate included 4780 Transmittance Standard 50, for 4775 Approx. 50% total transmittance, for checking purposes, certificate included 4781 Transmittance Standard 70, for 4775 Approx. 70% total transmittance, for checking purposes, certificate included 4782 Transmittance Standard 90, for 4775 Approx. 90% total transmittance, for checking purposes, certificate included 4783 Transmittance Standard Set, for 4775 Set of 5 pieces in hard box, certificate included