Error Detection and Correction Methodology for Laser Milling Processes on Biocompatible Ceramic Materials

Similar documents
Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing

Laser milling for micro tooling

Automatic NC Part. Programming Interface for a UV Laser Ablation Tool

Short pulse laser milling effects on surface integrity. P V Petkov, S S Dimov, R. Minev and D T Pham

Efficient metal processing using high average power ultrafast laser

Increasing laser processing efficiency using multibeam and tailored beam profiles

Experimental studies on effects at micro-structuring of highly reflecting metals using nano- and picosecond-lasers

Novel manufacturing route for scale up production of Terahertz technology devices Penchev, Pavel; Shang, Xiaobang; Lancaster, Michael; Dimov, Stefan

Goal of APPOLO APPOLO Objectives Establish and coordinate connections between end-users application laboratories equipment manufacturers Facilitate

ZEISS Smartproof 5 Your Integrated Widefield Confocal Microscope for Surface Analysis in Quality Assurance and Quality Control

»»»LASER GENERATION IV The Innovation for your Success

Feasibility of Laser Induced Plasma Micro-machining (LIP-MM)

TL Laser Systems for Tool Measurement

Complete 3D measurement solution

Influence of Geometrical Configuration of Cantilever Structure on Sensitivity of MEMS Resonant Sensors

Company Pioneer in Ytterbium ultrafast lasers High quality manufacturing Intense and active R&D Located in Bordeaux and Paris US offices in Boston and

Advances in Disk Metrology

Real-world applications of intense light matter interaction beyond the scope of classical micromachining.

Precision Engineering

Recent Advances in Ultrafast Laser Subtractive and Additive Manufacturing

3D-Analysis of Microstructures with Confocal Laser Scanning Microscopy

Measurements using three-dimensional product imaging

Calibration of a portable interferometer for fiber optic connector endface measurements

Non-destructive, High-resolution Fault Imaging for Package Failure Analysis. with 3D X-ray Microscopy. Application Note

INSPECTION OF MACHINED PARTS FROM CAD MODEL USING 3D PROFILOMETRY

HOLOGRAPHIC FEMTOSECOND LASER PROCESSING AND THREE-DIMENSIONAL RECORDING IN BIOLOGICAL TISSUES

Development of a Simulation Method of Three-Dimensional Ultrafine Processing by Femtosecond Laser Shunsuke Nabetani 1, a, Hideki Aoyama 1, b * 1, 2, c

Comparison between 3D Digital and Optical Microscopes for the Surface Measurement using Image Processing Techniques

Improving dimensional accuracy by error modelling and its compensation for 3-axis Vertical Machining Centre

The Mathematical Modeling and Computer Simulation of Rotating Electrical Discharge Machining

Development of Visual and Other NDE Methods

T-SCAN 3 3D DIGITIZING

Exam Microscopic Measurement Techniques 4T th of April, 2008

ADVANCED TEMPORAL CONTROL IN HIGH ENERGY ULTRAFAST LASERS DEDICATED TO MICROMACHINING AND BIOMEDICAL APPLICATIONS

Laser welding. New in the range Laser devices Accessories. Laser welding fillers

CinCam CCD - Technical Data -

Thickness and waviness of surface coatings formed by overlap: modelling and experiment

Lightsheet Z.1. Light Sheet Fluorescence Microscopy by Carl Zeiss. Fabrice Schmitt, Sales Manager Carl ZEISS France

The Application of CAD/CAM in the Design of Industrial Products

Optics for nonlinear microscopy

An Experimental Analysis of Surface Roughness

CNC Milling Machines Advanced Cutting Strategies for Forging Die Manufacturing

Identification of process phenomena in DMLS by optical inprocess

Diamond FLQ-Series. Q-Switched Fiber Lasers FEATURES & BENEFITS

Phenom TM Pro Suite. The ultimate application software solution. Specification Sheet

Particle Image Velocimetry for Fluid Dynamics Measurements

ADAPTIVE SLICING WITH THE SANDERS PROTOTYPE INKJET MODELING SYSTEM. Abstract. Introduction

Enhanced optical absorptance of metals using interferometric femtosecond ablation

Optimized Design of 3D Laser Triangulation Systems

MULTI-AXIS POSITIONING APPROACH OF MONOLITHIC CUTTING TOOLS FOR LASER MICROMACHINING SVOČ FST 2017

Mikro-und Nanostrukturierung mit Ultrakurzpulslasern für Werkzeugtechnik und funktionale Oberflächen

COLOCALISATION. Alexia Ferrand. Imaging Core Facility Biozentrum Basel

Optical Sectioning. Bo Huang. Pharmaceutical Chemistry

New Opportunities for 3D SPI

Laser readiness for all optical EUV FEL

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

Ultrafast Laser Helical Drilling of Three-Dimensional Shaped Holes using Synchronized Adaption of Energy Deposition

F-Theta at Jenoptik a holistic approach

Silicon Avalanche Photodiodes in Dynamic Light Scattering

Calibration and setup of a tool probe

Industrial Metrology. Multisensor Measuring Machines O-INSPECT 322/442

Unified feature based integration of design and process planning

GEOMETRICAL SURVEY OF COMPACT ANTENNA TEST RANGES USING LASER TRACKER TECHNOLOGY

Vibration-assisted Surface Texturing Yanjie Yuan, Jian Cao, Kornel Ehmann

Novel Manufacturing Platform for Scale up Production of Miniaturized Parts

AUTOFOCUS SENSORS & MICROSCOPY AUTOMATION IR LASER SCANNING CONFOCAL MICROSCOPE IRLC DEEP SEE. Now See Deeper than ever before

Chemical Characterization of Diverse Pharmaceutical Samples by Confocal Raman Microscopy

Micro Cutting Tool Measurement by Focus-Variation

Optimization of Laser Cutting Parameters Using Variable Weight Grey-Taguchi Method

Fuel Cell Preparation. The anode supported SOFC studied was Ni-YSZ/YSZ/LSM-

SURFACE BOUNDARY MEASUREMENT USING 3D PROFILOMETRY

High-Power Femtosecond Lasers

Focused Ion Beam Micro Machining and Micro Assembly

High Resolution Phased Array Imaging using the Total Focusing Method

Journal of Machine Engineering, Vol. 12, No. 2, MATHEMATICAL MODELLING OF THE LASER MACHINING PROCESS OF SAPPHIRE CRYSTAL Al 2 O 3

DC - Devices and Controller

LASERS FOR ANALYTICAL INSTRUMENTATION

Length, Germany, PTB (Physikalisch-Technische Bundesanstalt)

Sample Introduction Systems SOLID LASER ABLATION

Mitutoyo General Catalog

CHAPTER 4 DESIGN AND MODELING OF CANTILEVER BASED ELECTROSTATICALLY ACTUATED MICROGRIPPER WITH IMPROVED PERFORMANCE

PARAMETERS INFLUENCING THE PRECISION OF SLM PRODUCTION

Fabrication of highly precise fiber optical array products by use of laser based micro alignment

MEMS SENSOR FOR MEMS METROLOGY

3D X-ray Microscopy Characterization. Metal Additively Manufactured Parts. Application Note

UNIVERSITY OF PLYMOUTH

Applications of adaptive optics in femtosecond laser material processing

Ultrafast Scan Techniques for 3D-µm Structuring of Metal Surfaces with high repetitive ps-laser pulses

Fork sensors and optical windows

Three-dimensional Simulation of Robot Path and Heat Transfer of a TIG-welded Part with Complex Geometry

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

LIFA KEY FEATURES APPLICATIONS. Fluorescence Lifetime Attachment LIFA 15001A02 16/03/2015

LIFA. SPECIFICATIONs. Fluorescence Lifetime Attachment LIFA14001A02 25/02/2014

Near Field Observation of a Refractive Index Grating and a Topographical Grating by an Optically Trapped Gold Particle

Technology Transition Workshop Jack Garner. Carl Zeiss PALM. Technology Transition Workshop

PicoBlade Picosecond Micromachining Laser

AUTOMATED 4 AXIS ADAYfIVE SCANNING WITH THE DIGIBOTICS LASER DIGITIZER

4D IMAGING AT YOUR FINGERTIPS Real-time, Portable, High-Resolution Solutions for your Quality Control Needs

Real time micro/nano particle detection and tracking with. nanosecond resolution

UMASIS, AN ANALYSIS AND VISUALIZATION TOOL FOR DEVELOPING AND OPTIMIZING ULTRASONIC INSPECTION TECHNIQUES

Transcription:

KES Transactions on Sustainable Design and Manufacturing I Sustainable Design and Manufacturing 2014 : pp.574-582 : Paper sdm14-044 Error Detection and Correction Methodology for Laser Milling Processes on Biocompatible Ceramic Materials Iñigo Llanos 1, Amaia Agirre 1 Harkaitz Urreta 1 1 IK4-Ideko, PO Box 20870, Arriaga industrialdea 2, Elgoibar, Spain illanos@ideko.es Abstract This paper shows the work done on the correction of laser milled geometries on biocompatible ceramic material for medical prostheses. After the exposition of the error detection and correction methodology to be followed after the machining of a geometrical feature, the experimental procedure for the application of the methodology is detailed. Finally, the obtained results are exposed and discussed. The results show that the error detection methodology is able to properly identify the defective zones and define a laser milling process for their correction, in order to obtain a geometry within the defined tolerances in comparison to the theoretical one. 1. Introduction The application of ceramic materials as zircon dioxide (ZrO 2 ) as the base for medical prostheses has become broadened due to their inertness and biocompatibility [1]. Besides the machining of the prosthesis bodies, micromanufacturing processes have been successfully applied for the modification of the prosthesis interfaces in order to improve their interaction with biological tissues and overall oseointegration [2]. While mechanical micromanufacturing processes have been applied for the preparation of prosthesis surfaces, their application range is limited due to the high tool wear generated during the machining of the ceramic materials [3]. In order to avoid these problems related to tool wear, mechanical machining processes can be applied to semi-sintered parts but, due to the shrinkage generated during the final sintering process, the final part can lose the desired accuracy or even get cracked due to the non-totally homogeneous shrinkage [4]. This way, the application of laser ablation processes to already sintered parts can help obtaining the desired part accuracy while avoiding the problems related to mechanical micromachining processes. However, the laser ablation processes can show several instabilities due to different sources such as poor surface quality (scratches and defects), inhomogeneities on the workpiece material, lifting of the material during machining InImpact: The Journal of Innovation Impact ISSN 2051-6002 http://www.inimpact.org Copyright 2014 Future Technology Press and the authors 574

or unsteady laser source energy output. These problems may lead to geometrical deviations on the machined workpieces in comparison to the desired theoretical geometries. Due to the long processing times and high operational costs related to ultrafast laser ablation processes, the generation of these defects can make the process non-competitive in comparison to the traditionally employed manufacturing processes. In order to avoid them, devices and adaptive process methodologies have been developed, mainly linked to macro-machining laser process as laser welding [5]. However, in the case of ultrafast laser ablation processes, more sensitive devices with very high dynamics are required. This way, for the definition of an adaptive process control scheme, a considerable work for the monitoring of the process state and parameters should be carried out. Furthermore, the monitoring data would require extensive analysis so decisions could be defined for the correction of the process parameters. These points lead to very complex equipment and methodologies that could be applied for the real-time process control during ultrafast laser ablation operations [6]. Nevertheless, a control that would focus on the final geometry of a machined part would not require such a real-time control along the whole machining process. Thus, the present work, instead of defining an adaptive process control scheme, proposes the use of an error detection and correction methodology on the laser milling of ceramic prostheses in order that a defect minimization scheme can be incorporated into it. 2. Error detection and correction methodology The material removal rates obtained during the ultrafast laser ablation processes are comparatively low regarding other manufacturing processes. This way, the focus of the error detection and correction methodology would be the control of key geometrical features (final shape) instead to the whole process for the manufacturing of a complex geometry. The overall structure of the error identification and correction methodology proposed on the present work is shown in Figure 1. After the machining of a key geometrical feature, it is measured so it can be compared to the theoretical geometry. Once this comparison is carried out, a decision can be made on continuing with the defined process if the machined feature is inside the defined tolerances, scrap the part if the generated errors are not recoverable or, if it can be corrected, define a new machining loop for the correction of the feature and, this way, generate the desired geometry. 575

Machining of next geometrical feature Feature correction machining step Obtain feature actual shape Yes Yes Geometry comparison to theoretical one Inside tolerances? No Part recoverable? No Scrap the part Figure 1: Diagram for the error detection and correction methodology. The generation of the machining step for the correction of the defects is founded on the difference between the actual and the theoretical geometries for a given feature. Once this difference is calculated, it is divided into simple square areas and a mean height error value is calculated for each of them. The comparison of this height error with the geometrical accuracy defined for the part will identify the areas that require a correction step. Based on this, the (X,Y,Z) location of an area that would require the correction step is stored into a file, also including the desired depth for the correction. By processing the information for the location and depth for each correction, the identification of how many correction steps (based on the square areas) would be required is carried out. Finally, a NC code file is automatically generated, containing the location for each correction step and the call to a parameterized laser milling cycle already coded on the laser ablation machine 3. Experimental procedure The tests have been carried out on an in-house developed laser ablation machine (Figure 2). This machine is equipped with a Picosecond LUMERA Hyper rapid 25 laser beam source. The laser scanning is carried out by the movement of the X-Y stages, leading to low speeds in comparison to galvanometric heads. Nevertheless, this speed limitation should not be an issue regarding the evaluation of the error correction methodology presented here. The laser pulse characteristics employed for the laser milling trials were based on experimental tests done on sintered zirconia: wavelength (λ) 1064 nm, repetition rate (f) 250 khz, power (P) 6,94 W, pulse duration (τ H ) 10 ps, scanning speed (v s ) 5 mm s -1 and a focal diameter (d w ) of 20 µm. All of the machining work was carried out at standard atmospheric conditions without any gas assistance. 576

Figure 2: The in-house developed ultrafast laser ablation machine IK-Laser. The error detection and correction methodology has been applied to the laser milling of simple geometries (square cavities of 0.5 mm side and 50 µm depth). In order to evaluate the capability of the methodology presented on this paper, artificial geometrical defects were introduced into the theoretical geometries. The tests were carried out on already sintered yttria stabilized zirconia blocks. The sintering steps can be seen in Table 1, which was carried out following instructions from the provider. Table 1: Steps followed for the sintering of the yttria stabilized zirconia blocks. Sequence Time Preheating rate up to 900 ºC (8 ºC min -1 ) 110 min Holding time at 900 ºC 30 min Preheating time to final temperature of 1500 ºC (9 ºC min -1 ) 75 min Holding time at 1500 ºC 120 min Cooling rate down to 900 ºC (4 ºC min -1 ) 150 min Holding time at 900 ºC 20 min Cooling rate down to 200 ºC (4 ºC min -1 ) 175 min Total time 11 h 20 min As commented above, the correction of the geometrical deviations is founded on the difference between the actual and the theoretical geometries so, numerical values for the geometries would be required in order to obtain this difference. This way, the laser milled geometries were measured employing a Sensofar PLu Neox imaging confocal microscope. Since the workpieces have to be taken away from the laser ablation machine in order to make these measurements, the repeatability of the workpiece clamping on the machine has to be guaranteed in order to ensure the correction process. Thus, a zero-point clamping system (Erowa FTS) with a 577

clamping repeatability < 2 µm was used for the fixation of the workpieces to the machine. The defect correction is carried out by laser milling of elemental square areas with the same size (30 µm side) as the ones the geometry difference was divided into. The employed laser milling strategy for the error correction is based on the machining of several layers on the Z direction until the desired correction depth is achieved. The depth of each layer on the Z direction was 10 µm so several layers were required for obtaining the desired correction depth. Each Z layer was machined by overlapping several laser scanning paths (Figure 3). The overlapping value employed was 10 µm, requiring 3 scanning paths in order to generate the desired cavity size. Figure 3: Laser trajectory for each Z level of the defect correction process. 4. Results and Discussion Top images from the laser milled cavities have been obtained by Scanning Electron Microscopy (SEM) employing a Zeiss Evo 40. Figure 4 shows the top image of a laser milled cavity with an artificially introduced defect (un-machined corner) can be seen in Figure 4. After measuring the cavity with the imaging confocal microscope, the measurement data is exported and treated by comparing it to the theoretical geometry, obtaining this way the difference between both. The measurement data, the theoretical geometry and the obtained difference can be seen in Figure 5, both on 3D and top representations. 578

Figure 4: Top image of the laser milled cavity with the artificial defect a) b) c) Figure 5: Top and 3D representation of a) laser milled cavity measurement data, b) theoretical geometry and c) difference between both After the difference between the theoretical and the actual geometry is calculated, it is divided into elemental square areas. The top and 3D representations of the difference before and after the discretization can be seen in Figure 6. By the evaluation of the mean height of each area in comparison to the defined manufacturing tolerance (15 µm), the elemental areas that will later be corrected are identified. 579

Figure 6: Top and 3D representation of the difference between the actual and theoretical data before and after its discretization. After the elemental areas that will require the later correction are identified, the (X,Y,Z,) location for each of them is identified and the required layers in the Z direction to obtain the desired geometry are calculated. Finally, the data for the machining of each of these layers is written into a NC code file in order to introduce it on the control of the ultrafast laser ablation machine and carry out the correction of the defective geometry. An example of the NC code for the machining of one of the layers from one elemental area can be seen in Figure 7. $X_ORIG=151.994+$OFFSETX $Y_ORIG=158.8971+$OFFSETY $Z_ORIG=-25.3+$OFFSETZ $DEPTH=0.025 CALL ZRO2_CORRECTION_CYCLE Figure 7: Example of the NC code generated for the correction of an area The top image of the cavity shown in Figure 4 can be seen in Figure 8 after the error detection and identification methodology has been applied. The top representation of the machined cavity before and after the methodology has been applied can be seen in Figure 9. As it can be seen, the artificially introduced error is identified and correction steps are created for this zone. Furthermore, some correction steps are created for the upper side of the cavity due to the slope of the theoretically vertical wall. 580

Figure 8: Top image of the laser milled cavity after the correction of the artificial defect Figure 9: Top representation of the machined geometry before and after the correction of the artificial defect. Nevertheless, as it can be seen in Figure 9, the depth of the zones machined by the correction methodology is different. In the case of the upper zone of the cavity, where the slope of the vertical walls has been corrected, the final depth is slightly higher (5-10 µm) than the theoretical depth of the cavity. On the contrary, the depth on the corner where the artificial defect was located is lower (10-15 µm) than the theoretical depth. This indicates that the laser milling process employed for the correction of the defective zones should be optimized in order to obtain an homogeneous depth within the whole cavity. Besides, the vertical walls created on the zone where the artificial defect was located do not match perfectly the walls from the original geometry, showing a slight offset (5-10 µm) with them. This point is related to the location of the discretization grid concerning the original geometry and should be further analysed in order to obtain a better dimensional quality on corrected geometries. 581

5. Conclusions The analysis of the obtained results can lead to the next conclusions: The imaging confocal microscopy allows for the proper characterization of the laser milled geometries in order to obtain numerical values for their treatment. The comparison between the theoretical and the actual laser milled geometries allows for the precise identification of the defective zones and the later application of the correction methodology. The proposed error detection and correction methodology is capable of generating a NC code file that would define the machining process for the correction of the defective geometries in order to obtain the desired geometry. The offsetting of the discretization grid employed for the evaluation of the errors on the geometry should be analysed in order to generate better dimensional accuracy on the corrected geometries. The laser milling process employed for the correction of the defective geometries requires an optimization in order to obtain the desired quality on the laser milled geometries. 6. Acknowledgements The research reported in this paper is supported by the European Commission within the project Minimizing Defects in Micro-Manufacturing Applications (MIDEMMA) (FP7-2011-NMP-ICT-FoF-285614). 7. References [1] Denry, I., Robert Kelly, J.: State of the art of zirconia for dental applications. Dental Materials vol. 24, 299-307 (2008) [2] Kirmizidis, G., Birch, M.A.: Microfabricated grooved substrates influence cell cell communication and osteoblast differentiation in vitro. Tissue Engineering A vol. 15, 1427 1436 (2009) [3] Holtaus, M.G., Twardy, S., Stolle, J., Riemer, O., Treccani, L., Brinksmeier, E., Rezwan, K.: Micromachining of ceramic surfaces: Hydroxyapatite and zirconia. Journal of Materials Processing Technology vol. 212, 614-624 (2012) [4] Holtaus, M.G.: Fabrication of Ceramic Micropatterns and their Impact on Bone Cells, PhD thesis, Universität Bremen (2011) [5] Bagger, C, Olsen, F.: Laser welding closed-loop power control. Journal of Laser Applications vol. 15,19-24 (2003) [6] Tong, T., Li, J., Longtin, J.: Real-time control of ultrafast laser micromachining by laser-induced breakdown spectroscopy. Applied optics vol. 43,1971-1980 (2004) 582