High-Temperature Susceptometer (Kappabridge)

Similar documents
6 x 6 Peltier-Thermostatted Multicell Holder Series II Accessory

CBT LW 4-PUMP ADD-ON INTERNATIONAL INSTALLATION GUIDE

Operation Manual for. Geolabsoft for Windows (PC version)

Heritage Group Inc. Magnetic susceptibility meter SM-100 USER S MANUAL. Publication Date: April 2005

Personal 3D Printer. Quick Start Guide. See Inside for Use and Safety Information

CH142: Instructions for the Vernier LabPro

Appendix C. Vernier Tutorial

INSTALLATION AND OPERATIONAL INSTRUCTIONS FOR THE OFITE MODEL 1000 VERSION 1.0

Use of the Bartington Instruments MS3 magnetic susceptibility meter

Prism Starter Guide 1.0 Hoskins Lab Last Modified 03/14/2017 Chris DeCiantis

CH142 Spring Spectrophotometers with Vernier Data Acquisition Software

Nano DSC and MCDSC. Site Preparation Guide

Penetration: Penetrometer PNR 12 (Bitumen)

Wireless Remote Controller Kit

LECO LM247AT Microhardness Tester & Amh43 Software

Interface I-300 / I-300 Pro Technical data sheet

JR-6A Spinner Magnetometer: Quick Start Guide

Magnetic Upright Bike

CDD4 Series Room CO2 Transmitter Installation Instructions

1 Introduction. Tilt the screen 2 Installation, safety and maintenance

NMR Users Guide Organic Chemistry Laboratory

Appendix 1: DataStudio with ScienceWorkshop Sensors Tech Tips

Model SR411i-KG Patient Floor Scale Service Manual Part No. MAN411i-KG_ Page 1 of 16. Patient Floor Scale. Operating and Service Manual

Interface I-300 / I-300 Pro Technical data sheet

Netzsch TGA Training Notebook

Assembly and Maintenance

Model SRV411i Small Animal Floor Scale Service Manual Part No. MANSRV411i_ Page 1 of 16. Small Animal Floor Scale. Operating and Service Manual

The Radio Control Temperature Logger (RCTL) Manual For hardware version 1.0 Manual version 1.0b

BGA IRDA-WELDER User Manual. Model: T870A

PROCEDURE FOR TENSILE TESTING OF REINFORCING BARS

USER S MANUAL. DAS-G01 The Power of Tomorrow

Thermal Diffusivity Instruments DLF-2 with EM-1600

2.2. Facilities Requirements

Physical Property Lab IMS VS CookBook

Photo Parts List T-Jet 1 & 2

Checklist for the SMPS & CPC (5.400 & 5.500) PART 1 Setup of the external Plumbing (for the DMA and the CPC):

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

Meta-Press. Porcelain Pressing Furnace. Quick Start Instructions & Reference Manual

Instruction Manual. RS 3D Printer

FOX-50 Heat Flow Meter

CDD Carbon Dioxide Transmitter

Moving-Minds.com Treadmill Desk Operation

FROG-4000TM Quick Start Guide

2-1. the ESI Probe Assembly. the PEEK Safety Sleeve and Sample Tube to the ESI Probe

SpiritStation by Napa Technology

Conductivity and TDS Meter Pen Style Water Quality Meter

XRD-DSC General (BB) D/teX Package Measurement. XRD-DSC General (medium resolution PB/PSA) Package Measurement

Manual for Jasco-IR-spectrometer

WineStation by Napa Technology

Aqueous GPC Instructions - Detailed

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

SMTmax T-8280 IR Preheating Plate

Discovery SDT650. Site Preparation Guide. Revision A Issued March Page 1

Int3233. Soldering Station. Instruction Manual

NEBULA X USER MANUAL. Redefining Tradition. Read carefully before using the device and save these instructions.

WK7200. Water Quality Test Kit USER S MANUAL

Manual. LC-16 system. LC-16 Inkjet Printer 1

NAME EET 2259 Lab 3 The Boolean Data Type

Title: Bruce Furnaces Semiconductor & Microsystems Fabrication Laboratory Revision: C Rev Date: 02/21/06

1. Review the printer safety information in the Regulatory Compliance document provided with your printer.

iphone XS Max Rear-Facing Cameras Replacement

Determination of Drag Coefficient

Title: Karl Suss MA150 Semiconductor & Microsystems Fabrication Laboratory Revision: E Rev Date: 03/01/06

WL7 SPARKLING MAIN DRAWING WL7 FW SPARKLING. Wetted, Ice Bath and Firewall Drawings - see next page

FluoroSELECT Fluorometer User s Manual

MFD Thermal Process Controller Manual

C100 Handheld Cond./TDS/Sal. Meter. Instruction Manual

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

Datacard CR500 Instant Issuance System. User Reference Guide. July Rev B

Ch En 475: Introduction to Instrumentation and Signal Processing with Labview

Setting up an Intermec PM43 printer with InterDriver version M-0 or newer

Delivering the right equipment. for your unique laboratory

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display

LEXMARK X CARTRIDGE REMANUFACTURING INSTRUCTIONS

Ch En 475: Introduction to Instrumentation and Signal Processing with Labview

AL-Series INSTRUCTION MANUAL AL-311 AL-201S. American Weigh Scales, Inc. Analytical Balances American Weigh Scales, Inc. pcs% kgct.

HP Pavilion dv7-6c90us Cooling fan Replacement

Zebra XiII-Series Printer Quick Reference Guide

TMA Standard Operating Procedure [Updated April 30, 2015]

Nanosight NS300 NBTC User Instructions

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply

LECO (TruSpec CN) - Quick Reference Guide

Removal and Installation8

ph600 2-wire ph/orp Transmitter

Operating Manual TifMan Operating Software For Dripper Test Bench

CR-40ATA - CR-60ATA CR-40ATAV CR-40AT CR-60AT CR-40ATV

TD2100 Electric Gummed Tape Dispenser Owner s Manual

Unpacking and Installing the Flora 2512 UV Printer. Steps 1: Unscrew the 10mm bolts holding the top. Then remove the top and put in a safe place.

OPERATING INSTRUCTIONS

POLOS CPK WAFER SPINNER SOP

Samsung Galaxy S10 Front-Facing Camera

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

Magnetic Immunoassay Reader Operator Manual

Zeiss Z.1 Lightsheet. Quick-Start Guide

3000 CONTROLLER TRAINING MANUAL. April 26, 2012 Software Version

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

Prepulse Inhibition (PPI) Boxes

Operation Guide CT100

USER GUIDE TO BECKMAN COULTER FC500

MacBook Pro 13" Touch Bar Late 2016 Display Assembly Replacement

Transcription:

High-Temperature Susceptometer (Kappabridge) [Kappa] Room 262 (Kappa) Sensitivity 4 10 8 SI; Frequency: 920 Hz Temperatures: ambient to 1000 K Several hours/sample ( 200 mg chip or powder) for complete temperature sweep See IRM Quarterly, Spring 1994, Vol. 4, No. 1 (magnetic quantities and units) See IRM Quarterly, Summer 1994, Vol. 4, No. 2 The Kappabridge consists of a measurement station, an electronics box, numerous sample holders, a computer, a furnace control box, cooling water and pumps under the table, various small tools, and supplies. Contents: Part 1. Room-Temperature Bulk Susceptibility Measurement Part 2. Anisotropy of Magnetic Susceptibility Part 3. Temperature Dependence of Susceptibility Part 4. Calibration Appendix A. Using Kappabridge offline (without computer) Appendix B. IRM sample Coordinate System Appendix C. 15-Position AMS Measurement Scheme - 1 -

Part 1: Room-Temperature Bulk Susceptibility Measurement PART 1. ROOM-TEMPERATURE BULK SUSCEPTIBILITY MEASUREMENT I. SAMPLE PREPARATION 1) Your sample should fit into one of the plastic sample handlers for the Kappabridge. If necessary, pick a plastic sample holder from the cardboard box on the Bartington table in Room 288. You may also use a standard straw/gelcap. II. INSTRUMENT SET-UP 1) Make sure the cylindrical plastic spacer is in place in the measuring space. 2) Turn on the Kappabridge by setting its power switch to the on position (toggle switch at lower right corner of electronics box). 3) Zero the meter: With the range set to 1 (left side of the electronics box) and no sample in the measurement space, adjust the large knob on the measurement box until the needle on the Re ( Real ) meter on the electronics box reads in the middle. III. CONTROL PROGRAM 1) Start the program by clicking on the Kappa_bulk.exe icon on the desktop. 2) Select the proper User and Specimen ID from the database. 3) The software volume-normalizes the data, so a volume is required. If you need to add or revise the specimen volume, you may do so at this time. 4) Measure the empty sample holder: a. Set Range to 1 b. When green ready light is lit on the control box, click the Holder measure button. c. Insert empty sample holder quickly into measurement space. d. When machine beeps, quickly remove holder. e. If you are using plastic boxes, you may include an empty box to further correct your data. 5) Range check. To test that the instrument is set on the proper range, place your sample in the sample holder and then: a. When green ready light is lit on the control box, click the Range Test button. b. Insert sample quickly into measurement space. c. When machine beeps, quickly remove sample. d. Repeat as necessary, adjusting the range switch on the instrument to get the largest possible value on the LED display (full-scale is ±1999). 6) Take measurement. Repeat Steps 5a 5c, but use the Measure button. - 2 -

IV. SHUTTING DOWN IRM Users Manual Instruments: High-Temperature Susceptometer (Kappabridge) Part 1: Room-Temperature Bulk Susceptibility Measurement 1) Turn off the Kappabridge by setting its power switch to the off position (toggle switch at lower right corner of electronics box). 2) Remove the cylindrical plastic spacer from the bottom of the measuring space using the suction-cup toy. - 3 -

Part 2: Anisotropy of Magnetic Susceptibility PART 2. ANISOTROPY OF MAGNETIC SUSCEPTIBILITY I. SAMPLE PREPARATION 1) Your sample should fit into one of the plastic sample handlers for the Kappabridge that allow for sample rotation. Draw a single arrow on the top of your sample that corresponds to the x-axis. See the diagram on the wall, or in Appendix B, for the IRM s orientation scheme. II. INSTRUMENT SET-UP 1) Put the cylindrical plastic spacer into bottom of the measuring space. 2) Turn on the Kappabridge by setting its power switch to the on position (toggle switch at lower right corner of electronics box). 3) Zero the meter: With the range set to 1 (left side of the electronics box) and no sample in the measurement space, adjust the large knob on the measurement box until the needle on the Re ( Real ) meter on the electronics box reads in the middle. III. USING THE CONTROL PROGRAM 1) Start the control program by double-clicking on the KLY2AMS.exe icon on the computer desktop. 2) Select the proper User and Specimen ID from the database. 3) The software volume-normalizes the data, so a volume is required. 4) Measure the empty sample holder: a. Set Range to 1 b. When green ready light is lit on the control box, click the measure empty holder button. c. Insert empty sample holder quickly into measurement space. d. When machine beeps, quickly remove holder. 7) Range check. To test that the instrument is set on the proper range, place your sample in the sample holder and then: a. When green ready light is lit on the control box, click the Range Test button. b. Insert sample quickly into measurement space. c. When machine beeps, quickly remove sample. d. Repeat as necessary, adjusting the range switch on the instrument to get the largest possible value on the LED display (full-scale is ±1999). - 4 -

Part 2: Anisotropy of Magnetic Susceptibility 8) Take measurements: a. Place sample in holder in position 1 (see diagram on wall or Appendix C). b. When green ready light is lit on the control box, click the Measure next button. c. Insert sample quickly into measurement space. d. When machine beeps, quickly remove sample. e. Repeat steps 8b 8d for positions 2 15. f. To repeat a particular measurement position, click the appropriate Repeat Measurement box. 9) Click the Compute button to calculate tensor fit and anisotropy parameters. The data may be viewed plotted on a stereonet by clicking the Details button. 10) All positions, or select positions may be re-measured at this time. Click Compute again when you are done. 11) Save data: when satisfied with the results, click the Save button. IV. SHUTTING DOWN 1) Exit the control program. 2) Turn off the Kappabridge by setting its power switch to the off position (toggle switch at lower right corner of electronics box). - 5 -

Part 3: Temperature Dependence of Susceptibility PART 3. TEMPERATURE DEPENDENCE OF SUSCEPTIBILITY I. SAMPLE PREPARATION 1) Your sample should fit into the small test tubes that go inside the furnace. Small chips or powders ( 100 mg or so) should be weighed beforehand. You may want to take a difference weight between the empty sample tube and the full one. You can fill the test tube to a height of about 1 cm or less. Rock chips are generally more stable than powders. II. INSTRUMENT SET-UP 1) Make sure the cylindrical plastic spacer is not in the measuring space. If it is, remove it with the appropriate tool. 2) Turn on the Kappabridge by setting its power switch to the on position (toggle switch at lower right corner of electronics box). 3) Turn on the furnace control box with its power switch (upper right). Water should start circulating through the system and the green Cooling light should come on. If it does not, see IRM staff for assistance. 4) Zero the meter: With the range set to 1 (left side of the electronics box) and no ample in the measurement space, adjust the large knob on the measurement box until the needle on the Re ( Real ) meter on the electronics box reads in the middle. 5) Remove the furnace from its storage holder, and place it in the transport ring above the measurement space, being careful of the hoses and wires. The keyway on the furnace fits into the nub on the left side of the ring. 6) Slide your test tube (with sample) into the black plastic collar, and then replace the whole assembly into the furnace. 7) Gently insert the thermocouple until it touches the sample. 8) (OPTIONAL) If using argon to prevent sample oxidation: a. Gently insert the argon tube. b. Open the valve on the argon bottle in the corner. Make sure that the pressure regulator is set at the marked value. c. Check the flow gauge (sitting on bench top); adjust the flow with the black knob to approximately 100 cc/minute. - 6 -

Part 3: Temperature Dependence of Susceptibility III. USING THE CONTROL PROGRAM 1) Before starting, make sure you have a user folder in the /Usr/Guest/ directory. 2) Start the control program by typing double-clicking on the Curie Temp in English icon. 3) Use the function (F) keys to change parameters for your run. Typically, the only parameters you will want to change are the minimum and maximum temperatures for your experiment. (The absolute maximum temperature that the Kappabridge can reach is 700 C.) Leave the other values unchanged. Press F5 when ready to continue. 4) Enter filename: a. If necessary, select F5 to change directory (e.g. Guest/Julie/). b. Enter filename, keeping in mind that you must adhere to the DOS filename conventions (maximum 8 characters). A.cur extension will automatically be added to the filename. 5) When a blank plot appears on the screen, register your choices with the function (F) keys: a. Press F3 to test the range. After the measurement is made, adjust the range switch if necessary to get a value on the LED display between ±1000 and ±1500 (full-scale is ±1999; initial values between ±1000 and ±1500 allow for a moderate increase without going off-scale). Repeat this step as many times as necessary. b. Make sure the temperature reading at the top of the screen is something reasonable (i.e. near room temperature). If it is not, see the IRM staff for assistance. c. Press F5 to start the heating run. 6) The program will plot the data in real time. Use the function (F) keys to change run parameters at any time. a. Press F1 to reset temperature range. b. Press F5 to stop the run at any time. 7) Check data and instrument occasionally to make sure that the background signal doesn t drift out of range (Step II-4) and/or the measured susceptibility doesn t increase out of range (Step III-5). If either of these things happens, you will not acquire meaningful data. You may change the range setting and/or re-zero the bridge while the wait light is on between measurements. 8) When the run is finished, you will be prompted to press enter to return to DOS. 9) Use the Kappa_high_T_ferret program to upload data to the database. Susceptibility values in the raw data file are in quasi-volume-normalized SI units, assuming a sample volume of 10 cm 3 = 10 6 m 3. When uploaded to the database, a proper volume (or mass) normalization will be made using the volume (or mass) you have supplied. - 7 -

Part 3: Temperature Dependence of Susceptibility IV. REMOVING SAMPLES 1) Carefully remove the argon tube and return it to its holster. Close the valve on the argon tank. 2) Remove the thermocouple and return it to its holster. 3) When the sample is cool enough (< 50 C), remove the sample holder test tube by lifting the black plastic collar at the top of the furnace. 4) Cleaning up: a. Remove your sample from the test tube. b. Carefully and thoroughly clean the test tube with water and alcohol (and acetone, if necessary), using the test tube brush and the Q-tips to get it clean. Rinsing with alcohol will allow it to dry faster than if water is left in the tube. c. Carefully mop off the temperature sensor with alcohol. d. Citrate-bicarbonate-dithionate (CBD) solution may also be used for occasional cleaning of the test tubes and thermocouples. V. SHUTTING DOWN 1) Turn off the furnace control box with its power switch (upper right). 2) Remove the furnace from the transport ring, and replace the furnace into its storage holder, being careful of the hoses and wires. 3) Turn off the Kappabridge by setting its power switch to the off position (toggle switch at lower right corner of electronics box). - 8 -

Part 4: Calibration PART 4. CALIBRATION Periodic calibrations are done by IRM staff; visitors generally do not need to do this. 1) Set range to 5. 2) When the ready light comes on, press the start/reset button. 3) Insert the standard [ ETALON No. 157, R=5, Xn=167 ] quickly into the measurement space. 4) At the beep, quickly remove the standard. 5) If the LED display does not read 1167 (within 1%, i.e., between 1155 and 1179), adjust the calibration screw (lower left corner) with the small screwdriver and repeat steps 2-5 as necessary. - 9 -

Appendix A: Using Kappabridge Offline APPENDIX A: USING KAPPABRIDGE OFFLINE (WITHOUT COMPUTER) 1. When ready light on, press start/reset button. 2. Insert sample quickly 3. When machine beeps, quickly remove sample. 4. Adjust range switch as necessary to get largest possible value on LED display (full-scale is +-1999. Repeat as necessary. 5. Calculate (by hand) value of raw susceptibility by multiplying number on LED display with appropriate factor noted on range setting. 6. Repeat for blank sample holder and subtract from raw measurement. 7. The susceptibility thus obtained will be in micro-si, assuming your sample is 10 cm 3. If it is not, you must un-normalize by 10 cm3 and then re-normalize either by mass or by volume. Example: Let s assume that 8.13 g of a typical lake sediment has been repacked into a P1 box with a volume of 5.28 cm 3. Suppose that, using range 3 (and therefore multiplier 0.2), an empty P1 box (with sample holder) measures 26 on the LED readout (plastic is diamagnetic), and the box with the sample in it measures 1508. These numbers would yield the following susceptibilities: volume susceptibility: k = (0.2)(1508 26)(10 6 SI)(10.0 cm 3 ) 5.28 cm 3 = 5.81 x 10 4 SI mass susceptibility: χ = (0.2)(1508 26)(10 6 SI)(10 5 m 3 ) 0.00813 kg = 3.77 x 10 7 m 3 kg 1 Note that these exact equations are only correct if both the sample and the blank (empty sample holder) are measured on the same range. If not, you must use the appropriate range multiplier for each measurement, and then subtract. - 10 -

Appendix B: IRM Sample Coordinate System APPENDIX B: IRM SAMPLE COORDINATE SYSTEM - 11 -

Appendix C: 15-Position AMS Measurement Scheme APPENDIX C: 15-POSITION AMS MEASUREMENT SCHEME - 12 -