1. Overview Thank you for purchasing this ubisys ZigBee Router. You have decided for a high-quality product with first-rate support! This reference ma

RN-171-EK Evaluation Board

ZICM357SPx Thermostat Application Note: ESI

User Manual ZLOCK. ZigBee device for door lock. Revision: 2.0 date: 05/26/2016 Status: Approved Reference : UM_ZLOCK_ _001_02_00

USER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H. SW version 3.n

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

Installation Guidelines for KODAK SA101 Alarm System

Squid.link Gateway. The heart of wireless solutions. Bridging multiple wireless protocols. Smart home Energy management Home security Healthcare

USER MANUAL Mobeye CM-Guard CM2000

C24 Installation and Activation

GW-USB-05. User's Guide. FW v1.07. IQRF USB Gateway MICRORISC s.r.o. User_Guide_GW-USB-05_ Page 1

Application Note AN013

CTS-iCPE Gateway Controller User s Manual Version: Revision B1

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

ZIGBEE UNIVERSAL DIMMER D1(-R) REFERENCE MANUAL

EAGLE-200. Intelligent Control Gateway. User Manual

Technology Update: A Standard Modular Interface for Residential Devices

RN-134. WiFly GSX Super Module SuRF Board. Features. Description. Applications. ~ page 1 ~ rn-134-ds v1.

Automatic Phone-Out Home Monitoring System

5.1 Configure each Sensor Pin Rename Set Rules Export Data Switching Nodes... 25

ZIGBEE POWER SWITCH S1(-R) REFERENCE MANUAL

Colour Graphic Terminal User Manual. Rev 3.1

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 3/3/2011

Home Automation Gateway HA102

USER GUIDE EDBG. Description

Quick start: Panic Watch EU

Z-Stack Home TI-RTOS Developer s Guide

Access control panel U-Prox IC E (Elevator control)

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 1/24/2011

EZY SWITCH. SMS-8 System Monitor Installation Manual Applicable for firmware version 1.1 or above

JVA SMS Gateway User Manual

EVOHD. Programming Guide. Version

Mesh networking with ZigBee. A dive into the ZigBee ecosystem

AN4872 Application note

Contents About This Guide Audience Revision History

KCS TraceME TM-202 / R9C5 GPS / GPRS / SMS / RFID module, OEM Version

Wireless Expansion Module V2.0 OMN-RCV3. Reference & Installation Manual. Stand-Alone System

ZIGBEE UNIVERSAL DIMMER D1(-R) REFERENCE MANUAL

Carrier ComfortChoice Touch ZigBee Certified Thermostat Technical Specifications

Bosch solution 6000 cheat sheets

Table 1: Device summary Part numbers Device info (stored in register 0xF0 and 0xF1) Comment SPIRIT1QTR 0x0130 Cut 3.0

Contents. 4. Disarming the Control Panel How to Disarm with a User Code How to Disarm using a Key-Switch or Remote...

Latest functions of the SmartLiving firmware version 5.10

EDBG. Description. Programmers and Debuggers USER GUIDE

_A_en_LED63VG VOICE GUIDE KEYPAD LED63VG

AN1117: Migrating the Zigbee HA Profile to Zigbee 3.0

Radiocrafts Embedded Wireless Solutions

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

GPRS Pager 3 INSTALATION AND USER MANUAL

Firmware Flash Upgrade Wizard. User Manual

Instruction Manual Power plug Model number: STW-W3350WU

Lumina Version 2.15 Firmware Release

Wireless Expander Eclipse WL Installation and Programming Manual

A1000 GSM ALARM DEVICE

Smart Meters and Home Automation

Embit Binary Interface - WMBus Specific Documentation. embit s.r.l.

USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

Embit Binary Interface - IEEE Specific Documentation. embit s.r.l.

Modbus Map: Automatic Generator Start (AGS) Device

RN-174 WiFly Super Module

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

1. General Description

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

DC connector: 5VDC, 2,5A, round; 2,1x5,5x10 mm, inside positive External power supply: AC 230V 50/60Hz, 5V 2,5A out

Important Notice. Customer Information. 2 WisDom User Manual

AN4820 Application note

AN0512 Channel capacity in ranging applications

PWRguard PLUS Spring City Drive Waukesha, WI

Application Note: JN-AN-1123 ZigBee PRO Application Template

M-BUS-2. User Manual LORAWAN CONVERTER.

Modbus Map: System Control Panel (SCP) Device

Legal Notice. Page 2. Copyright MMB Research Inc. 2014

Zigbee protocol stack overview

Application Note: JN-AN-1122

UCM/KNX2 - Comfort to KNX Interface

HAN Device Validation Program. March 31, 2015

Study of Smart Home System based on Zigbee Wireless Sensor System. Jie Huang 1

XT30/XT50 PROGRAMMING PART 1. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 1. Accessing the Programmer

INT-KSG Keypad Quick user s guide

FIBARO SINGLE SWITCH

RC1140-RC232 Firmware Product Change Notification

LoRaWAN Pressure / Level and Temperature Sensor

STSW-BLUENRG1-DK. BlueNRG-1, BlueNRG-2 DK SW package

RN-174. WiSnap M2 Super Module. Features. Description. Applications. ~ page 1 ~ rn-174-ds v1.1 6/1/2011

Total Coach System. for Foretravel Users Manual. SilverLeaf Electronics, Inc Ferry St SW Albany, OR (888)

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 4/20/2011

NX-2192E PINPOINT SYSTEM

Universal Z-Wave Key Pad

Davide Quaglia Assistant CS depart University of Verona, Italy

DM3 Standard Component Interface Messages

NXP Smart Washing Machine Solution

IR868LR - IRUS915LR Programming manual

Transcription:

Key Fob ZHKF-101 Technical manual Revised 21.03.2016

Content 1 Cautionary notes... 5 2 Features... 6 2.1 Key Fob ZHKF-101... 6 2.2 Key features... 6 3 Endpoints... 7 3.1 ZigBee Device Object (ZDO)... 7 3.2 IAS Zone... 7 3.3 Develco Utility... 7 4 Supported Clusters...9 4.1 IAS Zone Device EP 0x23... 9 4.1.1 Basic Cluster id 0x0000... 9 4.1.1.1 Attribute...9 4.1.1.2 Manufacture Specific Attribute...9 ZCL header setting Manufactor code for Develco Products is 0x1015...9 4.1.2 Identify Cluster id 0x0003... 9 4.1.2.1 Attribute...9 4.1.2.2 Commands...9 4.1.3 Power Configuration - Cluster id 0x0001... 10 4.1.3.1 Attribute... 10 4.1.4 IAS Zone - Cluster id 0x0500... 10 4.1.4.1 Attribute... 10 4.1.4.2 Commands... 10 4.1.5 IAS ACE - Cluster id 0x0501... 11 4.1.5.1 Commands... 11 5 MMI user guide...12 5.1 General... 12 5.2 Arm Home... 12 5.3 Arm All... 12 5.4 Arm Night... 12 2

5.5 Disarm... 12 5.6 Panic... 13 5.7 Arming response... 13 5.8 Pairing a new device... 13 5.9 Pairing a used device (factory reset)... 13 6 General network behaviour... 14 6.1 Installation... 14 6.2 Normal Keep alive... 14 6.2.1 Network lost... 14 6.3 Low battery... 15 7 Specifications... 16 8 Contact Information...17 9 About Develco Products A/S... 18 3

Copyright Develco Products A/S All rights reserved. Develco Products assumes no responsibility for any errors, which may appear in this manual. Furthermore, Develco Products reserves the right to alter the hardware, software, and/or specifications detailed herein at any time without notice, and Develco Products does not make any commitment to update the information contained herein. All the trademarks listed herein are owned by their respective owners. RoHS 4

1 Cautionary notes Develco Products A/S reserves the right to make changes to any product to improve reliability without further notice. Develco Products A/S does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under patent rights or the rights of third parties. 5

2 Features 2.1 Key Fob ZHKF-101 The Key Fob is a ZigBee HA IAS ACE device. The devices can be used as a remote control for an Intruder Alarm System. The Key Fob has four buttons (Arming, Disarming, Night-arming, and Panic). It is battery powered with two standard AAA batteries. Any changes on the key-inputs will be reported. 2.2 Key features Key features are: IAS Ancillary Control Equipment (ACE). Certified ZigBee Home Automation application profile ZigBee PRO is supported RoHS compliant according to the EU Directive 2002/95/EC. Standard ZigBee Home Automation security and stack settings are used. 6

3 Endpoints The device implements the following standard HA devices on different end points. 3.1 ZigBee Device Object (ZDO) End point number 0x00 Application profile Id 0x0000 Application device Id 0x0000 Supports all mandatory clusters 3.2 IAS Zone End point number 0x23 Application profile Id 0x0104 (Home Automation) Application device Id 0x0402 The following clusters are supported on IAS Zone end point Server side IAS Zone Identify Basic Power Configuration Mandatory Optional Client side IAS ACE None 3.3 Develco Utility Application profile Id 0xC0C9 (Develco Products private profile) Application device Id 0x0001 Private profile for internal Develco Products use only. The DevUtil end point support a Develco products specified bootloader. New firmware can be downloaded to the device using the SmartAMM server + SmartAMM client tool. 7

Reference documents: 053474r18ZB_CSG-ZigBee-Specification.pdf 075123r03ZB_AFG-ZigBee_Cluster_Library_Specification.pdf 053520r27ZB_HA_PTG-Home-Automation-Profile.pdf 075356r15ZB_ZSE-ZSE-AMI_Profile_Specification.pdf They can all be downloaded from: http://www.zigbee.org/products/downloadzigbeetechnicaldocuments.aspx 8

4 Supported Clusters The ZCL General Function Domain clusters in this section are implemented as server clusters. Refer to ZigBee Cluster Library Specification. http://www.zigbee.org/specifications.aspx 4.1 IAS Zone Device EP 0x23 The IAS Zone end point contains the following clusters. 4.1.1 Basic Cluster id 0x0000 4.1.1.1 Attribute Id# Name Type Range Man/Opt Relevance and ref. 0x0 ZCLVersion Uint8 Type range M 0x4 ManufacturerName String 0-32 byte O 4.1.1.1.1 0x5 ModelIdentifier String 0-32 byte O 4.1.1.1.2 0x7 PowerSource 8 bit enum Type range M 4.1.1.1.1 ManufacturerName Develco Products A/S 4.1.1.1.2 ModelIdentifier ZHKF101 4.1.1.2 Manufacture Specific Attribute Id# Name Type Range Man/Opt Relevance and ref. 0x8000 PrimarySwVersion OctetString M SW version ZCL header setting Manufactor code for Develco Products is 0x1015 4.1.2 Identify Cluster id 0x0003 4.1.2.1 Attribute Id# Name Type Range Man/Opt Relevance and ref. 0x0000 IdentifyTime Uint16 Type range M 4.1.2.2 Commands The identify cluster has 2 commands as server. 9

Id# Name Payload Man/Opt Relevance and ref. 0x00 Identify Uint16 - Identify Time (seconds) M 0x01 Identify Query none M The identify cluster has 1 command as client. Id# Name Payload Man/Opt Relevance and ref. 0x00 Identify Query Response Uint16 - Identify Time (seconds) M 4.1.3 Power Configuration - Cluster id 0x0001 The power configuration cluster is described in ZigBee Cluster Library Specification 4.1.3.1 Attribute Id# Name Type Range Man/Opt Relevance and ref. 0x0020 BatteryVoltage Uint8 0x00-0xFF O Note: The attribute BatteryVoltage is measuring the battery voltage, in units of 100mV. 4.1.4 IAS Zone - Cluster id 0x0500 The IAS Zone cluster is described in ZigBee Cluster Library Specification 4.1.4.1 Attribute Id# Name Type Man/Opt Relevance and ref. 0x0000 Zone State 8-bit Enumeration M 16-bit 0x0001 Zone Type Enumeration M 0x0002 Zone Status Uint16 M Hard coded to Not Enrolled The following bits are supported: Bit3: Battery Bit4: Supervision reports Bit5: Restore reports Bit6: Trouble 4.1.4.2 Commands The identify cluster has 2 commands as server. 10

Id# Name Payload Man/Opt Relevance and ref. 0x00 Zone Status Change Notification Uint16 bit mask M The following bits are supported: Bit3: Battery Bit4: Supervision reports Bit5: Restore reports Bit6: Trouble When the battery is below 2.2 VDC Bit3: Battery is set high and Zone Status is transmitted to the coordinator. 4.1.5 IAS ACE - Cluster id 0x0501 The IAS ACE cluster is described in ZigBee Cluster Library Specification. The Cluster is implemented as a client cluster. 4.1.5.1 Commands The IAS ACE cluster has 2 commands as client. Id# Name Payload Man/Opt Relevance and ref. 0x00 Arm Uint16 bit mask M 0x04 Panic M Triggered when pressing the Arm, Disarm and Night arm buttons. Triggered when pressing the Panic button The Arm mode client command can contain the following values Arm Mode - Field Value Meaning Relevance and ref. 0x00 Disarming 5.5 Disarm 0x01 Arm Day/Home Zones Only 5.2 Arm Home 0x02 Arm Night/Sleep Zones Only 5.4 Arm Night 0x03 Arm All Zones 5.3 Arm All 11

5 MMI user guide 5.1 General User sees green LED shortly blinking after pressing any button this gives a visual feedback of successful pressing. Visual feedback when long key press time has expired. The feedback for long key press is a new green led blink. 5.2 Arm Home User presses Home ARM button Green led blinks shortly User releases Home ARM button Device sends Arm Day/Home Zones Only command Use case 5.7 Arming response is activated 5.3 Arm All User presses Home ARM button Green led blinks shortly After 3s green led blinks shortly to indicate long press User releases Home ARM button Device sends Arm All Zones command to backend Use case 5.7 Arming response is activated 5.4 Arm Night User presses Night ARM button Green led blinks shortly User releases Night ARM button Device sends Arm Night/Sleep Zones Only command to backend Use case 5.7 Arming response is activated 5.5 Disarm User presses DISARM button Green led blinks shortly User releases DISARM button Device sends Disarm command to backend Use case 5.7 Arming response is activated 12

5.6 Panic User presses PANIC button Green led blinks shortly After 2s green led blinks shortly to indicate long press User releases PANIC button Device sends Panic command to backend If command is delivered to backend, green led turns on for 1 second If command is not delivered to backend within 5s, the red led blinks quickly 3 times 5.7 Arming response Arm response code All Zones Disarmed Only Day/Home Zones Armed Only Night/Sleep Zones Armed All Zones Armed Invalid Arm/Disarm Code No response within 5s Blink pattern green led turns on for 1 second red led turns on for 1 second red led turns on for 1 second red led turns on for 1 second red led blinks quickly 3 times red led blinks quickly 3 times 5.8 Pairing a new device User presses any button to activate the device to start searching for networks User sees red LED slow blinking for while network search If no network is found within 15min, the device stops blinking and goes to sleep this use case can then be reinitiated at any time pressing any key If network found, the device stops blinking Pairing process requires no additional user interactions 5.9 Pairing a used device (factory reset) User inserts batteries into a device Within the first 60s, the user presses and holds upper right (DISARM) button Green LED blinks shortly After 5 seconds, the red led blinks fast Menu factory reset is selected. The user SHALL releases the DISARM button The device is reset to factory default 13

6 General network behaviour 6.1 Installation When the device is virgin and powered for the first time it will start looking for a ZigBee PAN Coordinator or router to join. The device will scan each ZigBee channel starting from 11 to 24. The LED will flash once every second until it joins a device. #Scan mode - 1 #Sleep mode #Scan mode - 2 #Sleep mode #Scan mode - 2 Scan all 16 ZigBee channel until join network or 15 MCU is in sleep mode (Radio off) 15 minutes Scan all 16 ZigBee ch x 1 or until join network MCU is in sleep mode (Radio off) 15 minutes Scan all 16 ZigBee ch x 1 or until join network ~ 30 seconds minutes ~ 30 seconds The device will start up using scan mode 1. To increase battery lifetime when the device is joining a network for the first time a scan mode 2 will be used after scan mode 1 has expired. Scan mode 1 it will only be executed one time when the device is powered. If the user invokes EZ-mode it will start scanning the next 3 minutes In section 5 MMI it is explained how to put the device into a join or leave network mode. Network settings are stored in NV-memory are after a power cycle the device re-join the same network. If the device has to join a new PAN coordinator the MMI menu supports a Reset To Factory Fresh Settings mode. This will erase all current network information. 6.2 Normal Keep alive The device is sending a keep alive message to the PAN coordinator every 15 minute to verify that the device is still connected to the network. 6.2.1 Network lost If no keep alive responses are received 5 times in a row (Worst case 1h15m), the devices will start scanning as specified in the table below. When the device is in scan mode the LED will flash once every second until it re-joins the network. According to the ZigBee specification TX is NOT allowed to be enabled all the time and a TX silent period has to be defined. #Scan mode - 1 #Sleep mode #Scan mode - 2 #Sleep mode #Scan mode - 2 14

Scan current ch 3 times Scan remaining 15 MCU is in sleep mode (Radio off) 15 minutes Scan current ch 3 times Scan remaining 15 MCU is in sleep mode (Radio off) 15 minutes Scan current ch 3 times Scan remaining 15 ch 1 ch 1 time ch 1 time time Scan all 16 ch 3 times 6.3 Low battery The current battery voltage can be read from the power configuration cluster described in section 4.3.1. The attribute BatteryVoltage is measuring the battery voltage, in units of 100mV. 15

7 Specifications Dimensions Colour Battery Battery life 72 x 30 x 18 mm Black 2 x AAA, exchangeable Up to 2 years Operation temperature 0 to + 50 C Sensitivity Output power -92 dbm +3 dbm 16

8 Contact Information Technical support: Please contact Develco Products for support. products@develcoproducts.com Sales: Please contact Develco Products for information on prices, availability, and lead time. 17

9 About Develco Products A/S Energy efficiency, Savings & Comfort Develco Products provides communication systems for AMR, AMI and Smart Metering. Develco Products presents a complete solution facilitating the remote control of appliances via intelligent electricity meters or gateways also capable of communicating with other meters. SmartAMM SmartAMM is a modular concept securing a flexible and forward-looking Smart House solution. SmartAMM makes it possible to monitor and control your home s electrical appliances and energy consumption via smart meters. SmartAMM combines automated meter reading with home automation, and includes: AMR (Automated Meter Management) for existing metering solutions AMR for meter manufacturers Communication modules for integration in meters or appliances (ZigBee, Z-Wave, PLC, GPRS, GSM and others) Data concentrators with back-office communication (GPRS, SMS, Internet, Fiber, PLC) Home Automation Benefits Cheap and reliable metering Reduced energy consumption Optimized energy consumption (peak level out) Avoidance of blackouts Sale of extra services: o Readout of several meters by diverse manufacturers and types (water, heating, gas, electricity) o Surveillance o Alarms Selected cases DONG Energy Gas (AMR of gas meters via GPRS data concentrator) Dong Energy Power (control and alarm via SmartRead power meter) EnergiMidt (SmartAMM concept covering metering (water & heating) and energy display via power meters as well as home automation. Everything integrated into one module and installed in the Echelon PLC power meter). 18