BE Battery Emulator KEY FEATURES FUNCTIONAL DESCRIPTION kw. 2 Quadrant Power Supply. Regenerative up to 100% rated power

Similar documents
B2C Bidirectional Battery Charger

Product Catalogue. v 1.0

LEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads

LEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)

Technical Data SINVERT PVS2000

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

MasterNOVA. MasterNOVA (3/1) MasterNOVA 250i - 600i (3/3) MasterNOVA Pro /3)

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

UPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications

THOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems

SMARTONLINE E3 UPS SYSTEMS

Liebert NX - Next Generation UPS for protecting your Business Critical Systems. AC Power Systems for Business-Critical Continuity

Kohler EW 6000TX. Transformer-based. (UPS kVA)

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

REGENERATIVE LOAD ERI SERIES

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

REGENERATIVE LOAD ERI SERIES

LAB-SCUBI SINGLE CHANNEL BIDIRECTIONAL PSU

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126

MP7. Uninterruptible Power Supply

SLI 15 INVERTER SERIES, 1500 W

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

Features. Description. Applications

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

MODULAR GRID-TIE SOURCE/SINK

Circuit Breaker Analyzer & Timer CAT66

LAB-HPP COMPACT HIGH POWER DC SOURCES

Modular three-phase UPS system. Conceptpower DPA kva True modular UPS system for critical applications

Programmable laboratory power supplies direct from the manufacturer

Circuit Breaker Analyzer & Timer CAT65

MUST 900 UPS. Finally the benefits of Modular ups are for all. 3 Phase Modular. Hot swappable, scalable 30kVA to 900kVA

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

LXM28AU07M3X motion servo drive - Lexium 28 - single and three phase V W

aentron Energy System 1 to 900 Vdc

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UPS Sentry MPS. SENTRY MPS is also compatible with different battery technologies: openvase lead acid and AGM and Gel VRLA, NiCd.

Est FlexiPower Maxi UPS FPX Maxi kVA

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

UPS TRIFASE kVA Rev. 8 Serie TPH IGBT

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

TopCon TC.GSS. the compact bidirectional process power supply

LOW POWER PLA SERIES. Interfaces. Electronic DC Loads

1. Introduction External description Front and Rear Panel The LCD screen Alarm Conditions...6

Liebert GXT MT kva

Circuit Breaker Analyzer & Timer CAT31

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications.

3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A

Tel: AC Power for Business-Critical Continuity TM

Modular UPS S KVA

5 MICROMASTER 420 specifications

Est ComPower Mini. Compact UPS kva

SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

CPS kVA TRIFASE EN50171

Circuit Breaker Analyzer & Timer CAT126

UPS EVO DSP TM ON LINE TM/TT. UPSman

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva

ATV1200A kv kva

TECHNICAL DESCRIPTION

Critical Power 2017 Catalogue

LAB-DSP HIGH DENSITY DC POWER SOURCE

Schneider Electric Easy UPS 3S

LED Driver Linear / area fixed output

Liebert NXr Series 30kVA to 160kVA. AC Power for Business-Critical Continuity TM

SATURN DATACENTER & SERVERS TELECOMMUNICATION DEVICE INDUSTRIAL APPLICATION TRANSPORTS. Smart Energy Solutions

the Centric 300 An advanced modular UPS up to 1800kVA/kW

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

LED Driver Compact fixed output

AC-DC Converter REC /60-K20

AB Axis Industries. Use

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

Single phase UPS. Applications. Highlights. 1ph from 450 VA to 10 kva. Home Office Computers and peripherals Networks and servers Small data centers

LED Driver Linear / area fixed output

SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase. online

SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)

PEL Series 60kVA. Regenerative AC Load Bank THE POWER TEST EXPERTS.

DSP Control. 0.9 Output Power Factor. Wide Input Range. High Efficiency Mode(ECO) Frequency Converter Mode. Input THDi<5% Output THDv<2%

DPS SERIES DC POWER SUPPLIES

SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

POWER ELECTRONICS / SD700 SERIES SD700 VARIABLE SPEED DRIVES

LBC Series 3-phase PSU / Battery Charger

DRTS 33. The new generation of advanced three phase relay test set

GAMATRONIC, A SolarEdge Division.

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

DACS ELECTROSYSTEMS PVT.LTD

ZP120N Online UPS. High Power Intensity. Flexibility. High efficiency with low heat dissipation. Smart Energy Solutions

Transcription:

A is a power electronics device that behaves as a real battery pack. CINERGIA s is based on a regenerative power supply. When emulating a battery charge, the energy will be injected back to the electrical grid consuming a sinusoidal current with unity power factor and low harmonic distortion. Using a will save space in the laboratory, avoiding safety issues of real batteries and allow a high flexibility in the tests. FUNCTIONAL DESCRIPTION Operation modes: -Constant Voltage (CV) -Static -Dynamic Three channels: The three channels can be configured independently, allowing emulation of different batteries at the same time The three channels can be configured in parallel, emulating one single battery with 3 times the rated current capabilityv Static mode: the emulated battery voltage will depend on the open-circuit voltage and internal charge and discharge virtual resistance. KEY FEATURES 6.75 160 kw 2 Quadrant Power Supply Regenerative up to 100% rated power 1 channel Output: 0 to 750V, 0 to ±555A 3 channels Output: 0 to 750V, 0 to ±A/ch Constant Voltage, Static, and Dynamic modes Dynamic mode: the emulated battery voltage will depend on the State Of Charge, rate of discharge and internal charge and discharge virtual resistance. CINERGIA Pintor Roig i Soler, 10 08916, Badalona, BARCELONA cinergia@cinergia.coop T. +34 934 864 358

CONCEPTUAL SCHEMATIC GRID AC EQUIPMENT UNDER TEST (EUT) BACK-TO-BACK TOPOLOGY Recommended The equipment is formed by two IGBT-based power stages: a grid-side Active Rectifier producing sinusoidal currents with low harmonic distortion and close to unity power factor; and three output converters generating three independent channels. Thanks to the bidirectionality of this topology the test energy can be injected back to the grid. TECHNICAL DIAGRAM AC IN (GRID side) OUT (EUT side) 3P+ N 3CH-COM filter -U -U filter CH1 CH2 CH3 Com_neg Current Drivers x 6 Voltage Drivers x 6 sensor x 2 Current Voltage DSP control CAN DSP control Voltage HMI MODBUS/TCP ETHERNET AC Input is connected to the grid (isolation transformer with neutral is recommended) Output is connected to the Equipment Under Test (EUT) and can be used as: - Independent channels mode: three 2Q channels with a common negative - Parallel channels mode: one 2Q channel (3 times rated current per phase)

USER INTERFACE CABINET Local 3.2 Touchscreen panel Remote Control port: LAN Ethernet with Modbus/TCP protocol. Digital IO port: -4 digital inputs -3 relay outputs -1 Emergency stop Cooling The power supply is air-cooled internally. Mechanical housing The power supplies are housed in compact cabinets with wheels up to 120kVA for easier transportation. Optional analog port: -1 analog input 0-10V -3 analog outputs 0-10V Optional communications: RS485, RS232, CAN, LabView SOFTWARE INTERFACE Windows 7/10 user interface for remote operation and data acquisition. STATIC MODE The battery is emulated through a simplyfied model based on fixed Voc and charge/discharge resistors. Voc Rch Rdisch + Vout - DYNAMIC MODE A model based on battery manufacturer data allows realistic voltage and SOC behaviour. OPERATION AREA: 1/3 CHANNELS 800.0 700.0 600.0 Output voltage (V) 500.0 400.0 300.0 Minimum voltage at rated power 200.0 100.0-1ch mode 0.0-3ch mode 0 3ch mode 1ch mode Output current (A)

RANGE AND SPECIFICATIONS MAGNITUDE VALUE ower (grid side) 7.5kVA-200kVA Input side (GRID side) AC Voltage Rated 3x400Vrms+Neutral+Earth Voltage range +15% / -20 % Rated AC Current Depends on model (see table) 10-290Arms per phase Frequency 48-62Hz THDi (at rated power) <3% Power Factor Typical at rated power 0.99 Configurable by user 0-1 (capacitive/inductive) Efficiency (at rated power) >92% Overload 125% for 10 min / % for 60 s Output side (EUT side) Voltage Channel-Com_neg 20 to 750V ( 60kVA) Channel-Com_neg 40 to 750V (>60kVA) Minimum voltage at rated power1 320V Current Parallel channels mode 0 to ±555A global Independent channels mode 0 to ±A per channel Overcurrent 110% during 1 min Operation Modes Range2 Resolution3 Ripple3 Constant Voltage 5-100% <±0.1% <1% Static 5-±100% <±0.1% <1% Dynamic 5-±100% <±0.1% <1% Response time Rated resistance load 1-5ms (10-90%) General Measurements User interface Input Voltage (Vrms) and Current (Irms) Input and Output Power Output Voltage and Current Temperatures 3.2 Touchscreen Local Control port: 4 digital inputs, 3 relay outputs (Option for AIO) Communication Port: Ethernet (Optionals: RS485, RS232, CAN) Communication Protocol: Modbus/TCP 10-90% (Absolute maximum, without condensation) 5-35 ºC (Absolute maximum) Forced air Over Current, Over Voltage, Shortcircuit, Overtemperature Humidity Temperature Cooling Protections Standards CE Marking Safety EN-62040-1-2, EN-60950-1 : EN-62040-2 1 Below minimum voltage the power is limited by the rated current of the unit. Contact us for further detail 2 Range is related to rated values of each model as defined in table MODELS 3 Resolution and ripple are related to the FS of each model. Contact us for further information.

MODELS REFERENCE 7.5 10 15 20 30 40 50 60 80 100 120 160 200 RATED kva 7.5 10 15 20 30 40 50 60 80 100 120 160 200 kw 6.75 9 13.5 18 27 36 45 54 72 90 108 128 160 GALVANIC ISOLATION (recommended) RATED CURRENT Independent mode Parallel mode 0-750v 0-750v ±10A ±15A ±20A ±25A ±30A ±38A ±47A ±57A ±105A ±130A ±130A ±155A ±A ±30A ±45A ±60A ±75A ±90A ±115A ±140A ±180A ±315A ±390A ±390A ±465A ±555A WEIGHT kg 265 290 290 540 550 DIMENSIONS DxWxH (mm) 770x450x1100 880x590x1320 850x900x2000 REFERENCE RECOMMENDED CIRCUIT BREAKER WEIGHT kg DIMENSIONS DxWxH (mm) IT7.5 IT10 IT15 IT20 IT30 IT40 IT50 IT60 IT80 IT100 IT120 IT160 IT200 Type C - 25A Type C - 25A Type C - 32A Type C - 40A Type D - 80A Type D - 100A Type D - 125A Type D - 160A Type D - 200A Type D - 250A Type D - 315A Type D - 400A Type D - 500A (*) The transformer is delivered in a stand-alone cabinet IP23 174 217 280 381 435 458 514 612 753 Inside the cabinet 595x415x708 (*) 789x490x865 (*) 964x684x1252 (*) 1192x744x1430 (*) OPTIONS Galvanic Isolation (recommended) Isolation monitor Isolated analog inputs RS485, RS232, CAN Labview drivers