Performance. Reliability. Simplicity. A smarter grid requires an intelligent recloser.

Similar documents
Effective May 2018 Supersedes October 2017

Elastimold Molded Vacuum Recloser - MVR

VisoVac padmount fault interrupter

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

Types R, RV, RX, VW, VWV, W, WV time- current curves

S&C IntelliRupter PulseCloser Outdoor Distribution (15.5 kv and 27 kv)

COOPER POWER SERIES. Visible-Break switch accessory operation instructions. Padmounted switchgear MN285011EN

Technical specifications for 5 ka, normal-duty distribution 4.5 kv and 5

S Reclosers Types NOVA 15, NOVA 27, and NOVA 38; Three-Phase Microprocessor-Controlled; Installation and Operation Instructions.

COOPER POWER. Types GN3E and GN3VE electronically controlled, manually closed sectionalizers SERIES. Sectionalizers Catalog Data CA270001EN

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module

COOPER POWER SERIES. Fusing Equipment Catalog Data CA132064EN. Effective February 2018 Supersedes January 2014 (240-50)

Innovation for MV distribution

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

Form 4A, Form 4C, Form 4D, Form 5, Form 5/TS, Form 6, Form 6-TS, FX, FXA, FXB, and SPEAR recloser controls time-current curves

SecTER cabinet COOPER POWER SERIES. Sectionalizing Cabinets Catalog Data CA901001EN. General. Optional features

Communications Point Data Base for Communications Protocol 2179

ELSP current-limiting backup fuse

SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch

S Reclosers Types NOVA 15, NOVA 27, and NOVA 38; Three-Phase Microprocessor-Controlled; Installation and Operation Instructions

COOPER POWER. UltraSIL polymer-housed VariSTAR IEEE surge arresters; normal-duty (5 ka), heavyduty, and riser pole (10 ka) for MV systems to 36 kv

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

COOPER POWER SERIES. 600 A U-OP visible break connector system operation instructions. Deadbreak Apparatus Connectors MN650022EN

Electrical solutions. Eaton and Cooper. united. Energizing. a world that demands more

S Sectionalizers Types TVS15 and TVS27 Time Voltage Sectionalizer Installation and Operation Instructions. Contents

Solid Dielectric Switchgear

Automation, Protection, Switching Applications

Solid Dielectric Switchgear Catalog S-trid13

COOPER POWER SERIES. DC motor operator control installation and operation instructions. Padmounted Switchgear MN285018EN

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Products Portfolio. Pole mounted Vacuum Recloser

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

ASCO SERIES 300 Manual Transfer Switch Solutions

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN

2.1 The NOVA-TS Triple-Single Recloser and Form 6-TS control shall be designed in accordance with the following standards as applicable:

Leverage substation gateway hardware to host a substation HMI and reduce costs

Vacuum-Break Switches

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

The Leviton Load Center THE FUTURE MADE CURRENT

Remote contact signaling available. visual status indication

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

LineScope. Smart Power Monitor. Bulletin DB50C18. US Patent Nos , , and B2

COOPER POWER SERIES. Data center solutions Envirotran HDC transformers deliver superior reliability and efficiency for substantial savings everyday

4-20mA SERIES Single or Dual Axis MEMS Inclinometer

DAS three-phase, vacuum-break distribution automation switch and idc control

ELSP current-limiting backup fuse

PROFIBUS Discrete I/O Modules

Diamondback. Solid Dielectric Load Break Switch Catalog. Distributed By;

Underground Distribution Switchgear

SVX9000 Adjustable Frequency Drives. Modular, Configurable, Compact

Innovative Solutions for Industrial Control

InHand Wireless. As an important sector of smart grid building, smart distribution network faces the

COOPER POWER SERIES. Fiber-optic/RS-232 communications module installation and operation instructions. Voltage Regulators MN225020EN

1492-SP Supplementary Protectors

NU-LEC. Loop Automation. Reclosers & Sectionalizers

Reclosers. Functional Specification Guide PS280026EN. Form 6 Rack/Yard-Mount Recloser Control

Figure 1. Storm Trapper H. E. arrester, external mount. Figure 2. Storm Trapper H.E. arrester, metal enclosed. use in Storm Trapper H.E. arresters.

Compact Coded Magnetic Safety Interlock Switch and Control Units

SERIES SD3800 / SD3810 SPECIFICATION

COMPACT SUBSTATION WITH 34.5kV GIS (GAS-INSULATED SWITCHGEAR. Cleverson Shindi Takiguchi S&C Electric Europe LTd. Cape Town/WC South Africa

Applying branch circuit breakers and supplementary protectors in North America

100mm Process Indicator Recorder

Recp HG Ig SGL 20A 125V 2P3W STR B&S or

TRANS-GUARD EXT CURRENT-LIMITING BACKUP FUSE 46KV - 138KV SYSTEMS

Amphenol Offers Wide Range of Connectors to Smart Building Market Connectors designed for optimal performance in demanding environments

Descriptive bulletin. OVR outdoor vacuum reclosers kv Innovative designs ensure system reliability

OSM PRODUCT GUIDE. OSM AUTOMATIC CIRCUIT RECLOSER 15kV, 27kV & 38kV Models

S&C M Series Switch Operator. Sophisticated Microprocessor Control of Overhead Distribution Switches

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

APL/UPL, 205/295 Series Magnetic Circuit Protectors

COOPER POWER SERIES. Ethernet communications module installation and operation instructions. Voltage Regulators MN225033EN

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

Compact plugs and receptacles standard or high temperature rated

power pazifik MV Switchgear Secondary Distribution Networks Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv

Form 6 Pole Mount Microprocessor-Based Recloser Control Technical Specifications

The Leviton Load Center THE FUTURE MADE CURRENT

GridShield outdoor vacuum reclosers kv Making distribution networks more reliable

Specifications. S&C Line-Rupters. For Line and Cable Switching. Outdoor Transmission (115 kv through 230 kv) Conditions of Sale

Prefabricated power solutions

Datasheet - AZ 16-02ZVK

Specifications. S&C Regulator Bypass Switches Type XL (Sequenced) and Type NL (Nonsequenced) Outdoor Distribution (14.

Magnetic Style Safety Interlock Switches

Datasheet - AZ 15 ZVRK

Air-insulated medium-voltage secondary distribution switchgear

Korry 1380 high-performance switch with oversized display for master caution and warning systems

CL-7 Microprocessor-Based Voltage Regulator Control and Accessories

Description GFCI HG ST DUPLEX 20A 125V BR Long Description GFCI HG ST Duplex 20A 125V BR

WIRELESS SERIES Single or Dual Axis MEMS Inclinometer

Datasheet - AZ 15 ZVK

COOPER POWER SERIES. Type GN3E and GN3VE sectionalizers installation and operation instructions

Sensors and Systems. Short Form. that protect your plant...

Sensors and Systems. Short Form. that protect your plant...

Extensive range of QPL standard and custom audio connectors trusted by our fighting forces for 35 years. MIL-DTL audio connectors

Each VariSTAR Type AZU arrester must pass the following production tests: 100% Physical Inspection 100% Leakage Current Test 100% RIV Test

FISCHER MINIMAX TM SERIES

1.4. Electronic Products. Contents Description E33 esm Keypad Multiplexed Switch Module Product Selection...

S HORT FORM. Catalog

Circular M8/M12 Interconnect Solutions for Industrial applications

Transcription:

NOVA NX-T recloser with Form 6 control COOPER POWER SERIES Performance. Reliability. Simplicity. A smarter grid requires an intelligent recloser.

Evolving technology requires smarter solutions up and down the line INTEGRATED ACCURATE SITE-READY WEATHERPROOF FLEXIBLE COMPACT ROBUST 2 EATON NOVA NX-T recloser with Form 6 control

Tighter O&M budgets, less time and more demands Utilities balance the need for reliable power against these realities every day. From installation and configuration to routine operation and maintenance, efficiency requires convenient product designs, hardened technologies and intelligent, communicating products. On an increasingly complex grid, it s all critical to system reliability. Eaton s Cooper PowerE series NOVAE NX-T recloser is designed with three goals in mind: Enhance sensing performance The NOVA NX-T recloser is a fully integrated solution with highly accurate, resistive source-side and optional loadside sensors, achieving ±2% accuracy across the full rated temperature range. Ensure reliability The NOVA NX-T recloser protects all sensitive control electronics in an IP43-rated enclosure. MIL-SPEC twist/lock connectors positively seal out moisture, and Eaton s proven epoxy insulation solution withstands extreme environmental temperature ranges. Simplify configuration and use From standard site-ready designs to large reflective 360-degree-viewable position indicators, every aspect of the NOVA NX-T recloser is designed for ease of configuration, installation, operation and control. EATON NOVA NX-T recloser with Form 6 control 3

Innovation from Eaton The NOVA NX-T recloser is founded on decades of industry leadership and proven solid epoxy design and vacuum interrupter technology. All key components from the microprocessor-based control to the integrated resistive voltage sensors, a robust magnetic actuator, the weather-resistant connector system, and the 360-degree position indicator are purpose built. Integrated six-sensor solutions through 38 kv, with 16 ka ratings through 27 kv. Exclusive resistive sensing for reliability and accuracy The NOVA NX-T recloser is the only integrated six-sensor resistive-sensing solution, enabling the accuracy and distribution system reliability critical to smart grid applications. Engineered specifically for this recloser, these high-integrity sensors are fully integrated with the tank. The complete system from sensors to control is ±2% accurate across temperatures from 40 C to +55 C. 4 EATON NOVA NX-T recloser with Form 6 control

A perfect connection every time Eaton s MIL-DTL-38999 Series IV Breech-Lok connectors positively lock cables in place with a simple 1/4-turn twist/lock mechanism. See, feel and hear when a positive connection has been made. The result is a MIL-SPEC solution that ensures the integrity of the connection and provides an unprecedented level of protection from the elements. Moisture and temperature protection A universal junction box integrated into the galvanized steel frame consolidates cables and protects connections from the elements. Also, wiring terminations to sensors are sealed inside the tank, providing a robust connection point. An IP43-rated control enclosure positioned at the lineman level protects sensitive electronics, and a time-tested epoxy insulation system withstands extreme temperature fluctuations all of which make the NOVA NX-T recloser an ideal choice for harsh environments. EATON NOVA NX-T recloser with Form 6 control 5

Visual verification from the ground level A quick glance at the underside of the NOVA NX-T recloser identifies the interrupter position. Red indicates closed green indicates open. Large, highly reflective surfaces are visible from any angle, even on the darkest nights or from the road during inclement weather...when it matters most. Mechanical safety interlock An integral safety interlock mechanically prevents contacts from closing when the operating handle is in the open position. IP43-rated enclosure All electronic components are located in an IP43-rated control box at lineman level to enhance serviceability. 6 EATON NOVA NX-T recloser with Form 6 control

Form 6 control proven, and utility SCADA ready Interfacing with the NOVA NX-T recloser and programming different schemes is simplified with an intuitive HMI and ProView application software. Configure and control on-site or remotely. Form 6 control Overcurrent protection IdeaE WorkbenchE custom logic tool Event simulation Sync-check Under/over frequency Discrete SCADA Time-saving, site-ready configurations Pre-wired tanks with sensors, arresters and PTs are convenient options that make the compact and lightweight NOVA NX-T recloser ready to lift to the pole. Pre-tested assemblies on a standardized frame system are ready for power connections in parallel in-line, perpendicular in-line, tri-mount or vertical phase-over-phase configurations. EATON NOVA NX-T recloser with Form 6 control 7

NOVA NX-T recloser options and accessories Terminals Eyebolt (standard) Two- or four-hole flat pad Stud-style, 1.125 threaded terminals Wildlife guards snap-fit installation Arresters/PTs or mounting provisions Source/load-side voltage sensors 5 A auxiliary switch Factory assembly options phase/ground leads and full site-ready designs Extended BIL Substation frames/brackets For Eaton s Cooper Power series product information, visit Eaton.com/cooperpowerseries Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No. BR280001EN / Z19879 August 2017 Eaton is a registered trademark. All other trademarks are property of their respective owners. Follow us on social media to get the latest product and support information.