SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

Similar documents
SIWAREX JB stainless steel with ATEX. certificate. Weighing systems. SIWAREX JB stainless steel with ATEX certificate.

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

Installation manual plugs and connectors with screw connection (16/32 A)

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Operating Instructions VEGAMET 381

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Siemens Drives & PLCs

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

B63/ NS MS. EtherNet/IP LINK

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

PHOENIX CONTACT - 12/2007

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

FDS / FDS-R / FDS-PS

SMARTLINE RM76 Supplementary instructions

Operating Manual -ENGLISH- Page 1 KWG-ISO

PHOENIX CONTACT - 01/2008

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

PI-EX-ME-2NAM/COC-120VAC

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Zener Barriers Bulletin 937Z

PI-EX-ME-2NAM/COC-24VDC

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Documentation KL channel Digital Output Terminal, 24 V DC, 2 x 4 A/1 x 8 A. Version: Date:

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

SolConeX extra-low voltage flange socket

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Siemens Industrial s

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

Manual Release 09/2002. cm-lon FOR LOGO! Communication with LOGO! with LON systems

Accessories for stand-alone gird inverter SMART LOAD 6000

Indication and adjustment. LG Remote Interface Operating Instructions 06/2015

Type 6150 AS-Interface Module. Type 3372 Electropneumatic Actuator with AS-interface module. Mounting and Operating Instructions EB 6150 EN

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Operating Instructions

Network nodes with gateway

TRIO-DIODE/12-24DC/2X10/1X20

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

5 B&W Rear View System Camera

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Analog display for resistance current

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

SolConeX Wall-Mounted Socket, 16 A

GV150 / GV151 Impulse amplifier and splitter for incremental encoder signals

FLEX Ex Spring Clamp Terminal Base

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

PTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21

Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date:

C9900-P223 and C9900-P224

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

PHOENIX CONTACT - 05/2007

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Accessories for Sunny Central COMMUNICATION CABINET (COM-C)

SUBCON-PLUS-PROFIB...

6173 AG GJB A0138

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date:

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Redundancy unit CP-A RU

C9900-P208 and C9900-P209

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

Operating Instructions

Series 3730 Type Electropneumatic Positioner

Model 4001A Modular System Bin Operating and Service Manual

EX-RC1 Remote I/O Adapter

Intrinsically safe batch controller Batching Master 110i

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Operating instructions

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

C4-TOP Manual (3.0E)

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

Operating Instructions

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

MACX MCR-EX-SD LP(-SP)

BK MIKRO. Air Barrier Adapter. Assembly Instructions Issue 1.00 dated

PNEUMATIC CRIMPER PC 12-8B OPERATING MANUAL

MINI MCR-SL-CVS NC

Transcription:

s SIWAREX JB Aluminum Housing Instruction Manual Edition 03/2006

Table of Contents Table of Contents... 2 Warning and Safety Terms... 3 General... 4 1 Technical Description... 5 1.1 Area of Application... 5 1.2 Structure... 5 1.3 System Configuration... 6 2 Installation/Assembly... 7 2.1 Installation... 7 2.2 Connection... 7 2.3 Installation... 11 2.4 Spring Terminal Connection Technique... 13 3 Commissioning... 14 4 Technical Data... 15 4.1 Functional Data... 15 4.2 Device Version... 15 4.3 Explosion Protection... 15 4.4 Electromagnetic Compatibility... 16 4.5 Dimensions... 16 5. Care and Maintenance... 17 6. Ordering Data... 18 A5E00400544B 2

Warning and Safety Terms DANGER Means, that death, severe injury to persons or damage to equipment will be caused if the respective safety measures have not been taken. WARNING Means, that death or severe injury can be caused if the respective safety measures are not taken. CAUTION With a warning triangle means that failure to take the necessary precautions may lead to minor injury. CAUTION Without a warning triangle means that failure to take the necessary precautions may lead to property damage. IMPORTANT Means that failure to observe the appropriate instructions may lead to an undesirable result or condition. NOTE Means a note of a possible benefit if recommendations are followed. Qualified personnel as referred to in the safety instructions in this manual and on the product itself are individuals who are familiar with the installation, assembly, initial start-up and operation of this product. They must be authorized and qualified to install, start and maintain devices, systems and circuits in accordance with national safety rules and regulations. Copyright Siemens AG 2006 All rights reserved Circulation or duplication of this document, utilization and disclosure of its contents are not permitted unless explicitly approved. Offenders will be liable for damages. All rights reserved, including rights created by granting of patents or registration of a utility model or design. Disclaimer We have tested the contents of this document for compatibility with the hardware and software described. This does not exclude the possibility of discrepancies, in which case we do not guarantee the complete compatibility of this document. The information in this document is assessed regularly and any necessary corrections are included in the next revision. We are grateful for any suggestions for improvement. Siemens AG Automation and Drives Process Instrumentation and Analytics D-76181 Karlsruhe Siemens AG 2006 Subject to technical changes A5E00400544B 3

General Intended Utilization Intended utilization means that this product is only to be utilized within the limitations defined in the technical specifications and purposes of use in this operating manual. There are no dangers associated with this device when conforming with the safety notes and the intended utilization. The fail-safe and secure operation of this device depends on proper transportation, storage, installation and assembly as well as on careful operation and commissioning. Proper operation of this device can only be ensured if the specifications provided in the technical data are observed. Improper handling can cause death, bodily harm and damage to equipment. Notes on Product Liability We expressly point out that the nature of the product is described exclusively and conclusively in the sales contract. The content of this product documentation is not part of an earlier or existing agreement, promise or legal relationship and neither shall it change any of these. All Siemens obligations ensue from the respective contract of sale which also contains the full and exclusively valid liability regulation. The provisions about product liability specified in the contract of purchase are not extended or limited by the information provided in this document. Delivery Notes The respective scope of delivery is listed on the enclosed shipping documents according to the valid contract of sale. Please observe the instructions printed on the packaging when opening. Check that the delivered goods are complete and undamaged. In particular, compare the order number on the type plate with the order data. Please read this manual before starting work! It contains important instructions and data which guarantee the general safety and functionality of this device when observed. This considerably simplifies handling of this product and leads to reliable measuring results. A5E00400544B 4

1 Technical Description 1.1 Area of Application The SIWAREX JB junction box made of die-cast aluminum serves for connecting load cells with the weigh module. Up to four load cells can be connected in parallel in one junction box (fig. 1-1). Another junction box must be connected in parallel by a cross connection in case of more than 4 load cells (fig. 1-2). Load cells with wire strain gages in 4 and 6-wire technology can be connected in parallel. The cable connection from the junction box to the weigh module and between two junction boxes must be made in 6-wire technique. The SIWAREX JB junction box may only be used with low voltages of 30 V. 4/6 JB 6 6 W 4/6 JB 6 W JB = Load Cell JB = Junction Box W = Weigh module = Load Cell JB = Junction Box W = Weigh module Fig. 1-1 Connection principle of 4 load cells Fig. 1-2 Connection principle of 8 load cells 1.2 Structure The housing is made of a heavy duty, powder-coated die-cast aluminum AlSi12. It consists of bottom part and lid. It is dustproof and splash proof according to the IP 66 degree of protection. The cables are fed into the housing through screw cable glands. High electromagnetic compatibility (EMC) is only achieved by the large area of the shield in the screw cable gland. The screw cable glands are made of nickel-plated brass. The electrical conductors are wired by spring terminals. The spring terminal technology guarantees vibration-free, maintenance-free connections. The contact reliability is permanently guaranteed. A potential equalization line can be connected via a PAL terminal. A5E00400544B 5

Revision 03.06 Technical Description 1.3 System Configuration The SIWAREX JB junction box is used in technical weighing systems for parallel connection of up to four wire strain gage load cells. If more than four load cells are to be connected to a weigh module, several junction boxes can be connected to each other by cross connections. Load cells can be connected in 4 and 6-wire technology. The technical data of the weigh module and load cells used must be observed with the maximum number of load cells. The total resistance of the parallel switched load cells must be in the range of the permissible load resistance of the weigh module. The junction box is connected with the weigh module with a signal cable. A shielded cable with six wires must be used as the signal connection. We recommend the SIWAREX cable Li2Y2x0,75St+2x(2x0,34St)-CY: 7MH4 702-8AG, orange coated, for standard applications or 7MH4 702-8AF, blue coating, for Ex-applications. The maximum cable length between load cells and weigh module can be found in the technical data of the weigh module. Intermediate elements such as Ex disconnectors must be taken into account. A5E00400544B 6

2 Installation/Assembly 2.1 Installation The SIWAREX JB junction box may only be installed and connected by qualified personnel. 2.2 Connection The connection of load cells with 4 or 6-wire technique to a weigh module must be made according to the wiring diagrams in fig. 2-1 or fig. 2-2, page 8. Analogously, several load cells are also connected in parallel. The pinout of the terminals is shown in fig. 2-3, page 9. Four terminals are connected in signal blocks with a plug-in bridge. The cable shields in the EMC screw cable glands should cover a large area (fig. 2-4, page 9). EMC cable glands and sealing plugs are delivered with the junction box. They should be mounted according to the number of load cells. Unused openings in the housing should be sealed with sealing plugs. The pinout of the screw cable glands is shown in fig. 2-5, page 10. When connecting load cells using 4 wires, two bridges are absolutely necessary: Bridge 1: Bridge 2: EXC- to SENSE- EXC+ to SENSE+ IMPORTANT If the two bridges EXC-/SENSE- and EXC+/SENSE+ are missing in load cells in 4-wire technology, this can be signaled by the weigh module as a wire break. A5E00400544B 7

Revision 03.06 Installation/Assembly Fig. 2-1 Load cell connection by 4-wire technique Fig. 2-2 Load cell connection by 6-wire technique A5E00400544B 8

Revision 03.06 Installation/Assembly Fig. 2-3 Terminal block Fig. 2-4 Shield in the screw cable gland A5E00400544B 9

Revision 03.06 Installation/Assembly EPD W W = Load cell Input W = Output to weigh module, to the Ex barrier or other junction box EPB = Equipotential bonding connection Fig. 2-5 Pinout of the screw cable glands A5E00400544B 10

Revision 03.06 Installation/Assembly 2.3 Installation The SIWAREX JB junction box can be mounted in any position. It should preferably be mounted horizontally. It is fixed with four M6 cylinder head screws. The dimensions of the fastening holes are shown in fig. 2-6, page 12. CAUTION Please check before closing the cover that there is no dirt or cable scraps in the housing that could cause malfunctions or short circuits. CAUTION The device protection degree is only guaranteed when the housing is closed. The lid must be mounted, necessary cable glands must be mounted and tightened. Unused openings for screw cable glands must be sealed with the sealing plugs provided. Please check that the sealing surfaces are clean and the o-rings are correctly in place on screw cable glands and sealing plugs. A5E00400544B 11

Revision 03.06 Installation/Assembly Fig. 2-6 Dimensions of the fastening holes A5E00400544B 12

Revision 03.06 Installation/Assembly 2.4 Spring Terminal Connection Technique A screwdriver with a maximum blade width of 2.5 mm is required to connect the cables. It is pressed into the rectangular opening (1). This opens the spring bracket. The stripped cable is pushed through the round opening to the stop (2). The cable is contacted tightly in the spring bracket by pulling out the screwdriver (3). (Fig. 2-7) Fig. 2-7 Connection of spring terminals The cables are stripped 8 to 9 mm. (Fig. 2-8) 8-9 mm Fig. 2-8 Stripping length IMPORTANT With smaller cable cross sections there is a danger of the stripped wire being snapped off when inserting in the terminal. The line is then connected to the insulation. The result is contact problems. Crimp-on sleeves prevent these problems. The following cables can be connected. 0.08 to 1.5 mm 2 / AWG 28 to 16: Single-wire, multi-wire, fine-wire also with tinned single wires, fine-wire stranded wire compressed and fine wire with gas-tight crimp-on pin cable shoe. 0.08 to 1 mm 2 / AWG 28 to 18: Fine wire with gas-tight crimped on end sleeves. A5E00400544B 13

3 Commissioning Since the junction box is a passive component the instruction manual of the weigh module should be observed primarily for commissioning. A5E00400544B 14

4 Technical Data 4.1 Functional Data Environmental temperature: -30 C to +85 C Storage temperature: -40 C to +90 C Protection: IP 66, DIN 60529 Freedom of vibration of the terminals: Conforming with DIN VDE 0611 11/77: 12 Hz and 50 Hz, Amplitude 1 mm Insulation resistance of the terminals: 10 12 Ohm cm 4.2 Device Version Housing dimensions (LxWxH): 220 x 120 x 81 mm 3 Housing material: aluminum AlSi12 Weight: approx. 2 kg Color: anthracite, Siemens color 614 Electrical connection: Spring terminal connection 1.5/1 mm 2 Screw cable glands: Load cells: 4x M16 x 1.5 5 to 10 mm Signal cable: 2x M20 x 1.5 7 to 12 mm 4.3 Explosion Protection The junction box is simple electrical equipment in accordance with EN 60079-14 or EN 50020. It may be used in hazardous areas also for connecting intrinsically safe circuits. The terminals meet the requirement for separating intrinsically safe circuits creep and air gap > 6 mm. WARNING To be observed when using in hazardous areas: - The regulations governing the installation and operation of devices in explosive areas that are in force in the country of use. - In EU countries, the laws passed in the relevant country to enforce EU Directive 1999/92/EC - The regulations for erecting electrical installations in areas with a risk of explosion DIN EN 60079-14 (VDE0165) or DIN EN1127-1. - EC Type Examination Certificate All work on electrical circuits for systems where there is a risk of explosion must be performed by qualified personnel. A5E00400544B 15

Revision 03.06 Technical Data 4.4 Electromagnetic Compatibility The SIWAREX JB junction box meets the following EMC requirements: EN 61326: 1999 EN 45501: 1992 NAMUR NE21: 2004 To maintain EMC, e.g. an EMC-compatible laying of cables (also inside cabinets!) must be observed. the signal cable must be laid separately from cables with voltages > 60 V or high currents. the vicinity of large electrical installations must be avoided. 4.5 Dimensions Fig. 4-1 Dimensions A5E00400544B 16

5. Care and Maintenance The junction box is maintenance-free. The clamping force of the spring terminals always remains constant. CAUTION Do not apply the jet of a high-pressure cleaner directly to the junction box. A5E00400544B 17

6. Ordering Data Name: SIWAREX JB junction box aluminum housing Order number: 7MH4 710-1BA A5E00400544B 18