NGBASE-T Cabling Requirements

Similar documents
Category 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

ISO/IEC TR Guidance on 40GBASE-T T Cabling

Fiber Backbone Cabling in Buildings

40G BASE-T Cabling Infrastructure. Allan Nielsen Standards Manager

Highlights: ISO/IEC SC25/WG3 Meeting Geneva: Sep Customer Premises Cabling -

Physical Layer changes coming to a network near you, soon! Wayne Allen Regional Marketing Engineer Fluke Networks

New standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks

ISO/IEC 11801: (E)

History Channel. 10G Ethernet on Copper

Fiber Optic Cabling Systems for High Performance Applications

Fiber backbone cabling in buildings

Ethernet The Next Generation

100 GBE - WHAT'S NEW AND WHAT'S NEXT

PREPARING FOR FUTURE STRUCTURED CABLING REQUIREMENTS IN THE DATA CENTER: 40/100 GIGABIT ETHERNET AND BEYOND

Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions. Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions

Frequently Asked Questions (FAQs) Siemon 10G ip Solutions

Data center applications standards reference guide

Standards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee

Certification for 10G copper cabling

Wideband Multimode Fiber What is it and why does it make sense?

Proposed PHY Objectives

10G Ethernet Over Structured Copper Cabling

INTERNATIONAL STANDARD

Optics Modules and Cables Data Sheet

FTTE Revisited for New Technologies

Ethernet evolution: what s new and what s next

Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only

IEEE Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3

Corrigendum 1 to Amendment 2 1 ISO/IEC ISO/IEC (second edition 2002) Information technology Generic cabling for customer premises

IEEE GBASE-T Study Group Closing Plenary Meeting Report

Optical Fiber Networks: Industry. and New Options for Networks

Cisco 100GBASE QSFP-100G Modules

Trends in Data Centre

DC Center Copper Cabling up to 40Gbase-T. Halim Senjaya

History of Standards

Standards Update. by Paul Kish NORDX/CDT

Optical Trends in the Data Center. Doug Coleman Manager, Technology & Standards Distinguished Associate Corning Optical Communications

Arista 400G Transceivers and Cables: Q&A

ExtremeSwitching TM. 100Gb Ethernet QSFP28 Transceivers and Cables. Product Overview. Data Sheet. Highlights. 100Gb Ethernet QSFP28 SR4 MMF

Cisco 100GBASE QSFP-100G Modules

Testing Considerations for Beyond 10Gigabit Ethernet. Erin Hallett

IEEE P802.3ba 40 GbE and 100 GbE Standards Update

40 Gigabit over copper - Thorsten Punke Marketing Manager ANZ TE Connectivity

Fiber in Data Centers What s Next? Srinivasan B, RCDD

NGEAB-T Use Cases. Berlin, Germany February Chris DiMinico MC Communications/Panduit

Objectives for Next Generation 100GbE Optical Interfaces

Updated Test Data for Channels based on Proposed Category 8.2 Connectivity IEC Augmented RJ45

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

40 GbE: What, Why & Its Market Potential

Optics Modules and Cables Data Sheet

LAN Standards, News & Trends Update 2017 June 15, 2017

ProCurve Mini-GBICs. Used with the following

Copper Cabling Standards

The AMP NETCONNECT Category 6 Cabling System

1 of 5 12/31/2008 8:41 AM

ISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies.

New Data Center and Transport Interconnect Technology

Ethernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement

Dell Networking Optics and Cables Connectivity Guide

TIA TR-42 Liaison to IEEE

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure

A Fork in the Road OM5 vs. Single-Mode in the Data Center. Gary Bernstein, Sr. Director, Product Management, Network Solutions

10 Gigabit Ethernet and Future Cabling for Offices + Data Centres

Proposal for an initial draft of a 10GBASE-CX4 PMD January 6, 2003

Everything you wanted to know about cabling, but were afraid to ask

Single-pair cabling channel specifications

Fast Lanes and Speed Bumps on the Road To Higher-Performance, Higher-Speed Networking

Cable into the Future: Industrial Ethernet with 10 Gbps

within IEEE Alan Flatman LAN Technologies

Cisco MDS 9000 Family Pluggable Transceivers

Leaders in the Advancement of Multimode Fiber. Fiber Future and Beyond

Key Items: - Customer Premises Cabling - 1 ISO/IEC SC25/WG3 Meeting Milan: Sep 2015

Connect to tomorrow. Standards. Decoding. Very high throughput Wi-Fi and the Internet of Things the impact on cabling system design.

Overcoming the Testing Challenges of 40G and Beyond. Eric Farst Channel Sales Manager

IEEE P802.3ba 40 GbE and 100 GbE Standards Update

Data Center High Speed Migration: Infrastructure issues, trends, drivers and recommendations

Fibre Channel over Ethernet and 10GBASE-T: Do More with Less

Industry Standards Activity Overview

Testing Parallel Optics

INTERNATIONAL STANDARD

The Impact of Emerging Data Rates on Layer One Fiber Cabling Infrastructures. Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress

Dr. Paulo Marin, EE/BSc, MSc, PhD. Electrical Engineer, ICT Consultant

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

IEEE Liaison report (Oct ) T v000 Tom Palkert, Macom

Higher Speed Ethernet Update

The AMP NETCONNECT Category 6 Cabling System

LAN Standards, News & Trends. Herbert V. Congdon II, PE Tyco Electronics Updated: October 10, 2008

Qualified Partner Programme QPP. Cat.6 Channel Meassurement Issues Felice Guarna

Introduction to Key Principles of Telecommunications Cabling

InstaPATCH Cu Cabling Solutions for Data Centers

Classical Ethernet (10 Mbps)

Cabling Infrastructure

Cisco 10GBASE SFP+ Modules

25GSMF Study Group: Work Items and Goals for Jan Meeting

Ronald Tellas, Technology and Applications Manager, Enterprise Networking

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

Optical Fiber for Today s Premises Applications

Simplify Fiber Optic Cabling Migrations with a Multi-Path System

Uniprise Structured Cabling Solutions Guide

Transcription:

NGBASE-T Cabling Requirements Dr. T. C. Tan, DMTS, CommScope Labs B.Sc (Eng), DIC, PhD, CEng, FIET White paper www.commscope.com

Contents Contents Contents 2 1.0 Introduction 3 2.0 IEEE 802.3 NGBASE-T Study Group 4 3.0 TIA Copper Cabling Sub-Committee (TR-42.7) 5 4.0 ISO/IEC Joint Technical Committee 1 Sub-Committee 25 Work Group 3 (JTC1 SC25 WG3) Cabling Committee 6 5.0 Cabling Architecture 7 6.0 Conclusion 7 www.commscope.com 2

1.0 Introduction NGBASE-T stands for Next Generation BASE-T, an Ethernet application beyond 10 Gb/s over twisted pair or balanced cabling. The Institute of Electrical and Electronics Engineers (IEEE) 802.3 NGBASE-T Call-for-Interest (CFI) was announced in July 2012, which led to the formation of a Study Group to investigate and possibly develop this technology. The main application for this technology is in the Data Center (DC) environment for server-to-switch connections within a row, typically referred to as end-of-row or middle-of-row architectures. Table 1 provides the options available for Information Technology (IT) managers to choose when looking to deploy 40 and 100 Gigabit Ethernet (40GbE and 100GbE) technology today. Table 1: 40GbE and 100GbE Options Interfaces IEEE Standard Supported Media 40GBASE-SR4 802.3ba Multimode Fibre @ 850 nm (4 Lanes) 40GBASE-LR4 802.3ba Singlemode Fibre @ 1310 nm (CWDM) 40GBASE-FR 802.3bg Singlemode Fibre @ 1550 nm (Serial) 40GBASE-KR4 802.3ba Backplane (4 Lanes) 40GBASE-CR4 802.3ba Twinax Cable (4 Lanes) 100GBASE-SR10 802.3ba Multimode Fibre @ 850 nm (10 Lanes) 100GBASE-LR4 802.3ba Singlemode Fibre @ 1310 nm (CWDM) 100GBASE-ER4 802.3ba Singlemode Fibre @ 1310 nm (CWDM) 100GBASE-CR10 802.3ba Twinax Cable (10 Lanes) SFP+ Direct Attach Cable None Fibre Cable Note: CWDM Coarse Wavelength Division Multiplexing Table 2 provides the various 40GbE and 100GbE technologies in development by IEEE at the present moment. Table 2: 40GbE and 100GbE Technologies in Development Interfaces IEEE Standard Supported Media 40GBASE-ER4 802.3bm Singlemode Fibre @ 1310 nm (CWDM) 100GBASE-SR4 802.3bm Multimode Fibre @ 850 nm (4 Lanes) 100GBASE-xxxx 802.3bm Singlemode Fibre at 500 metres 100GBASE-KR4 802.3bj Backplane (4 Lanes) 100GBASE-CR4 802.3bj Twinax Cable (4 Lanes) 100GBASE-KP4 802.3bj Legacy Backplane (4 Lanes) Notes: CWDM Coarse Wavelength Division Multiplexing xxxx Not defined yet. Depends on choice of technology Hence the IEEE 802.3 NGBASE-T Study Group will initially focus on developing a 40GBASE-T application. A previous white paper 1 published by the author provided a simple explanation for predicting the critical frequency for 40GBASE-T to be 1.6 GHz. Taking into account the IEEE request for 25% excess frequency for cabling specifications, the required next-generation cabling requirements would be specified to 2 GHz frequency. 1 The Future of Balanced (Twisted Pair) Cabling T. C. Tan, 21st August 2012 This paper will provide an update on the latest IEEE development for NGBASE-T and the associated cabling specifications development in the Telecommunications Industry Association (TIA) in the United States (US) and in the International Organization for Standardization (ISO)/ International Electrotechnical Committee (IEC) in support of this application. www.commscope.com 3

2.0 IEEE 802.3 NGBASE-T Study Group The NGBASE-T Study Group has adopted the following objectives: Support full duplex operation only Preserve the 802.3 Ethernet frame format utilizing the 802.3 MAC Preserve the minimum and maximum frame size of current 802.3 standard Support a BER 10-12 at MAC/PLS interface Support a data rate of 40G at the MAC/PLS service interface Support auto-negotiation Support Energy Efficient Ethernet Support local area networks using point-to-point links over structured cabling topologies, including directly connected link segments Do not preclude meeting FCC and CISPR EMC requirements Define a link segment based upon copper media specified by ISO/IEC SC25 WG3 and TIA TR42.7 meeting the following characteristics: -- 4-pair, balanced twisted pair copper cabling -- Up to 2 connectors -- Up to at least 30 m Define a single 40 Gb/s PHY supporting operation on the link segment At the January 2013 meeting, CommScope demonstrated a proof-of-concept solution for a viable 40GBASE-T channel by utilizing prototype (TIA) RJ-45 connectors and balanced twisted pair cables. The complete cabling channels consist of the following: One long and one short channel Horizontal cable Two RJ-45 outlets Two double-ended RJ-45 plug patch cords Cabling Channel under test RJ-45 cord RJ-45 outlet cable PL Long: 24 meters PL Short: 3 meters (PL: Permanent Link) RJ-45 outlet RJ-45 cord Long Channel: 30 meters, Cords = 3 meters Short Channel: 5 meters, Cords = 1 m Figure 1: Proof-of-Concept cabling channel demonstrated to IEEE NGBASE-T Study Group The channel parameters were measured to a frequency of 2 GHz and include insertion loss (IL), return loss (RL), near-end crosstalk (NEXT) and attenuation-to-crosstalk ratio far end crosstalk (ACR-F). This parameter was formerly known as equal level far end crosstalk (ELFEXT). This contribution 2 demonstrated the technical feasibility of the proposed TIA cabling systems and is a step along the path toward a viable 40GBASE-T solution for DC applications. Two aspects outlined by this proof-of-concept include the widely accepted RJ-45 connectors and the bandwidth capability of proposed TIA cabling. So far, two cabling companies have demonstrated prototype (TIA) connectors and one has demonstrated (TIA) cable to the NGBASE-T Study Group. 2 Structured Cabling Channel Demonstration by CommScope Wayne Larsen, IEEE NGBASE-T SG January 2013, Larsen_01_0113_NGBT It is very likely that this Study Group will proceed to become a Task Force and standardization work on 40GBASE-T will then commence after this Task Force formation. www.commscope.com 4

3.0 TIA Copper Cabling Sub-Committee (TR-42.7) In October 2012, the TIA TR-42.7 sub-committee selected as the nomenclature for the next-generation balanced twisted-pair cabling specifications under development. This specification was first proposed by CommScope in February 2012. Although the proposal did not explicitly specify the requirement for shielding, it is clear from the alien crosstalk specification that the minimum cabling construction design will include an overall shield (F/ UTP). In addition, as with current published TIA standards, the proposed draft standard requires cabling components to be backward compatible with lower categories of cabling. A matrix of backward-compatible mated component performance is provided in the draft standard and this is shown in Figure 2. Category of Modular Connecting Hardware Performance A Cat 8 Category of Modular Plug and Cord Performance A Cat 8 A A A Cat 8 Figure 2: TIA matrix of backward compatible mated component performance www.commscope.com 5

4.0 ISO/IEC Joint Technical Committee 1 Sub-Committee 25 Work Group 3 (JTC1 SC25 WG3) Cabling Committee In November 2012, ISO/IEC JTC1 SC25 WG3 proposed a draft technical report (PDTR) ISO/IEC 11801-99-1 entitled Information technology Guidance for balanced cabling in support of at least 40 Gbit/s data transmission. This PDTR document proposed two channel classes, namely Class I and Class II, which specified to 1.6 GHz with 2 GHz under consideration. Class I minimum cabling construction design will be F/UTP and Class II will be of x/ftp design. However, at a recent meeting in Mexico, ISO/IEC JTC1 SC25 WG3 agreed to adopt.1 and.2 as the nomenclatures for the next-generation components respectively for Class I and Class II channels. The proposed nomenclatures are now closely harmonized with the proposed TIA. However, there is also an identical requirement in the current published ISO/IEC IS 11801 cabling standard with regard to backward compatibility of different performance categories. The standard defines backward compatibility to mean that the mated plugs and jacks connections from different categories shall meet all of the requirements for the lower category component. Unfortunately, this will not be the case with the newly adopted nomenclatures as shown in Figure 3. The cabling industry will eventually have to come to terms with this situation for the sake of standards harmonization. Category of Modular Connecting Hardware Performance Category of Modular Plug and Cord Performance A Cat 7 Cat 7 A Cat 8.1 Cat 8.2 A Cat 7 Cat 7 A Cat 8.1 Cat 8.2 A A A A A A A A A Cat 7 Cat 7 A Cat 7 Cat 7 Cat 7 A A Cat 7 A A A Cat 8.1 Cat 8.1 Cat 7 Cat 7 A Cat 8.1 Cat 8.2 Figure 3: Matrix of backward-compatible mated component performance using the new Category nomenclatures from ISO/IEC JTC1 SC25 WG3 www.commscope.com 6

5.0 Cabling Architecture As stated, the main application for this technology is in the DC environment for server-to-switch connections within a row, described as end-of-row or middle-of-row architecture design. In response, the NGBASE-T Study Group has adopted a 30-meter, 2-connection channel model in order to reduce the complexity and associated power consumption of 40GBASE-T transceiver. Hence, this objective suits many DC designs that are now based on modular POD (Performance Optimized DC) or portable containerized designs. However, this objective deviates greatly from the familiar 100-meters, 4-connections cabling channel model that has been adopted by all currently published cabling standards. This will eventually be resolved in the various cabling standards committees, and it remains to be seen whether this dramatic change in architecture will be widely adopted by the cabling standards. Again, the industry will have to come to terms with this change when planning the migration to 40GBASE-T. 6.0 Conclusion IEEE 802.3 will soon commence standardization work on 40GBASE-T. This standard is likely to be referred to as IEEE 802.3bq and may take several years to complete. The cabling standards committees are in the early stages of developing balanced twisted-pair cabling specifications to support this application. The recent CommScope proof-of-concept contribution to the IEEE NGBASE-T Study Group has demonstrated the technical feasibility of the proposed TIA cabling systems utilizing the widely accepted RJ-45 connectors and has overcome a major challenge in developing cabling components to such a high frequency. In addition, the recent ISO/IEC JTC1 SC25 WG3 adoption of.1 and Category 8.2 as the nomenclatures for the next-generation components can be seen as a major achievement in paving the way for closer harmonization with the TIA proposal. www.commscope.com Visit our Web site or contact your local CommScope representative for more information. 2013 CommScope, Inc. All rights reserved. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. WP-106703-EN (3/13) www.commscope.com 7