ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL

Similar documents
ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL

SBLM-2-1x## Message Sign

AEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS

SERIES 208 INSTALLATION & OPERATING MANUAL

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Installation & Operation

VADDIO /CANON BU-SERIES PTZ CAMERAS

MODEL 715AN QUADRATURE DEGREES COUNTER

The AF Counter Timer with PP D or PP A Firmware

Microframe Corporation

AE21 SERIES DISPLAY CONTROL TERMINAL

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

AEXX-349 SERIES REMOTE DISPLAYS

EVERSAN. Instruction Manual MODEL 9007/9008 TENNIS SCOREBOARD. Address: 34 Main Street, Whitesboro, NY 13492

AUD-340 Installation Guide

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

Ratio Feeder Series J+ Advanced Pumper Controller

High Voltage DC Meter

EVERSAN. MODEL 9658 EVERSAN PERIOD INDOOR/OUTDOOR MULTI-FUNCTION SCOREBOARD. Instruction Manual

Digital Lighting Systems, Inc.

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

XL SERIES REMOTE DISPLAYS OWNERS MANUAL. MANUAL NO Rev. B November

MODEL 9386 MULTI-SPORT TIMER

2645 Series Counter Timers with 4 Tall Digits AF , AF , AF , AF

1:N REDUNDANT SWITCHING UNIT REMOTE CONTROL TERMINAL

Air Hockey v7.0 Controller PCB Air Hockey 10v Transformer

PD1100 STAND-ALONE PROGRAMMING & USER S GUIDE. use the freedom

ELECTRO-MECH SCOREBOARD CO.

UET Series Torque Analyzer Operations Manual

MODEL 9360-SO SOCCER SCOREBOARD

CARE AND MAINTENANCE

DT 200. Data Terminal Operators Manual Version 1.E 03/15/2010 Program S200001x

AE14-503J SERIES PRODUCTION DISPLAY SYSTEM

SBLM- User's Guide. Matko Message Center Help v1.1

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE

AUD-220 Installation Guide

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Model DMX24DIM Installation and Operations Manual

Keypad Lock. Operation and Service Manual. Order parts online

OPERATING MANUAL FOR SMIT-301MH STREAM SELECTOR

Industrial SBU Product User s Manual

MAXIMA + Series ROTARY LEVEL CONTROL

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

Model HM-535 Power Supply Installation and Service Instructions

About this Manual. Description

KNOX VIDEO RS16x16HB Routing Switcher. KNOX VIDEO RS16x16HB Routing Switcher SECTION 2. INSTALLATION

FA-2448 SIX POSITION Filter Wheel

VK-3iX WARRANTY REGISTRATION FORM

8 Button IP Controller Installation and Operation Manual AV-IP-C8-WH

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

LNX Series Motor and Drives

Installation Manual. Alpha 4000 RGB Signs. Before you begin

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

I/O SIGNAL CONDITIONER

11 Serial Communications

1 Overview. 2 Specifications. Product Installation Document

Model DS100 Scale Indicator

OPERATING INSTRUCTIONS AND SERVICE MANUAL BASKETBALL SHOTCLOCK MODEL MP-5299

RS-422 Code-Operated Switches

Digital Lighting Systems, Inc.

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

INSTALLATION PROCEDURE FOR THE INNOVEC IPT POWERED PRINTING TOTALISOR

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

AL-Series INSTRUCTION MANUAL AL-311 AL-201S. American Weigh Scales, Inc. Analytical Balances American Weigh Scales, Inc. pcs% kgct.

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE

EMS Electrical Management System

MODEL 714AN QUADRATURE COUNTER DESIGN CONCEPTS INC

OZONE SWITCH Model OS-6. OS-6 Features

3 Input Multiplexer Operation Manual

Service Instructions. Conductor 420

ELECTRO-MECH SCOREBOARD CO.

7561-PSD Manual Portable Battery Powered Indicator

Digital Lighting Systems, Inc.

Installation OVERVIEW

Copyright Western Scale Co. Limited. All rights reserved.

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

ELECTRO-MECH SCOREBOARD CO.

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

Sidewinder Pumps Inc. AC Timer/Controller

Rack Mount Power Supplies

ICM-25 INPUT CONTROL MODULE, 25 INPUTS RS-232(SERIAL) OUTPUT

INSTRUCTION MANUAL. Digivac 760 Series. Models 100Led P / P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro

Four IFB. Multi Line Phone Bridge. User Guide. JK Audio. Warranty

Getting Started with your D3000M Series Module

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

SI3300. user and installation manual. 4-20mA/DC-Digital Display

EP/2 Installation Instructions

DSP 4x4 Operation Manual

HIGH-VOLTAGE DC METER

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

MimioDisplay 550T, MimioDisplay 650T MimioDisplay 700T, and MimioDisplay 840T. MimioDisplay. Installation Guide. mimio.com

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Microframe Corporation

1:N REDUNDANT SWITCHING UNIT BROADBAND SERIES

Transcription:

ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL. 60101 www.electronicdisplays.com ED206/406-115 4D N1 - KY DESCRIPTION: 2.25 in. or 4.0 in. high, red 7 segment display; Programmable up/downtimer by a preset time. Serial interface (RS485) from EDI supplied Keypad. Easy to program protocol (See Appendix E). Power: 120VAC @ 60Hz. Battery Back-up to retain information. NEMA 1 rated enclosure w/ power supply. OPERATION: This display will count by a preset value at a preset time. (Example count by 1 every second). Factory set to increment by 1 every second. It can also be programmed to count by any number at any time interval. See Appendix E for protocol information. The keypad also allows the user to run/hold the display, reset to 0 or preset to a number. This board is addressable with a two-digit address(01). Addressing is required to communicate with the displays. There are 3 inputs located inside the right side of the display for wiring contact closure switches. The user has the option of wiring switches to the inputs or using the serial controlled run/hold. INPUT OPERATION: IN1 This is the Run / Hold input. Apply a momentarily short between Vext and IN1 to toggle the Run / Hold status. IN2 This will reset the display to 0 IN3 This input is the Up / Down select. Hard wired internally to for up-timing mode. If the jumper is removed, the display will operate in down-timing mode. If there are any questions or comments regarding this order, please call our Toll-free number: 1-800 - 367-6056

Unpacking Instructions: A copy of these instructions is packed with each unit. Open carefully to avoid scratching the unit s paint and plastic lens or cutting the line cord. Mechanical Mounting Instructions: This unit is equipped with two rivnuts in the top of the unit for mechanical mounting purposes. The bolts that are screwed into these rivnuts are standard 5/16 by 1 ¼ bolts. To avoid damaging the rivnuts, do not tighten these bolts more than 10 ft/lbs. Power Requirements: This unit is equipped with a standard, eighteen-gauge, three-wire line cord that is designed to be plugged into a standard, 120 VAC, 60 Hertz, grounded outlet. The maximum current draw for this unit (at 120 VAC) is _1.0 Amperes. Signal Requirements: If your unit has serial input (either RS-232, RS-422, RS-485, etc.), the standard communication format for this unit is 1200 bits per second (baud rate) with one start bit, eight data bits, no parity, and one stop bit per character. The expected sequence of characters is specified in a later section of this manual entitled Protocol. Product Components: See appendix A. Wiring Diagram: See appendix B. Label Definitions: The following page shows some commonly used labels and their definitions. Not all of these labels will be found in your unit. LABEL DEFINITION IN1, IN2, IN3, IN4 RX+ RX- AC Optically coupled input, active high, requires 12 milli-amperes of current to activate. Positive side of balanced data line for RS-422 or RS-485 serial input signals Negative side of balanced data line for RS-422 or RS-485 serial input signals Typically 10 to 12 VAC from EDI supplied transformer

Power-up Response: Upon power up, the unit will show the last value displayed before shipping. A battery back-up circuit retains the pre-loaded information. Unit will power up incrementing once per second. See Appendix E for details on protocol. Addressing: 1200; no parity; 8 data bits; 1 stop bit. Set to address 01. Protocol: See Appendix E Keyboard Input: APPENDIX E: COMMON ASCII CHARACTERS: All messages to these displays are made up of combinations of standard ASCII characters. The 16-key keypad supplied by Electronic Displays, Inc on the remote control panel generates one character per key. ASCII CODE KEYPAD LABEL VALUE (decimal) FUNCTION STX A 2 Start of text, also known as a Control B, this character must be the first character of each message ETX LF D B 3 10 End of text, also known as a Control C. Line Feed, also known as a Control J, this character is used as the last character of some setup messages. CR C 13 Carriage Return, also known as a Control M and as Enter, this character is also used as the last character of some setup messages. 0 thru 9 0 thru 9 48 thru 57 These are the standard ASCII printable decimal digit characters. They are used as both address characters and data characters. Variable Rate Timer Display: This display is capable of receiving three types of messages.

1 - Preset Message: The most common type of message is the preset message. This allows the user to start the display at some value other than zero. The display can also be preset to zero if the user desires (there is a control panel switch which will reset the display to zero). The protocol for a preset message is as follows: <STX> <2-digit address> <1-digit to 16-digit preset value> <CR> NOTE: While a leading zero is required in the address field, leading zeros are not required in the preset value field. To set the display to 45 from a telnet or other terminal window, type the following sequence of keys: <CONTROL B><01><45><ENTER> KEYPAD EXAMPLES: To set the display to 45 from an EDI supplied keypad, send the following sequence of keys. <A 0 1 4 5 C> 2 - Time Interval Message: The user has the ability to select how often the display increments from as fast as 100 times per second to as slow as once per 99 hours in increments. The protocol for a time interval message is as follows: <STX> <2-digit address> <2-digit hours> <2-digit minutes> <2-digit seconds> <1-digit tenths of seconds> <1-digit hundredths of seconds> <ETX> NOTE: The format for entering data is HH:MM:SS:TH NOTE: While a leading zero is required in the address field, leading zeros are not required in the time increment value field. To set the display to increment every 24 hours from a TELNET or other terminal window, type the following sequence of keys: <CONTROL B><01><24000000><CONTROL C>

To set the display to increment every 5 minutes and 30 seconds from a TELNET or other terminal window, type the following sequence of keys: <CONTROL B><01><00053000><CONTROL C> KEYPAD EXAMPLES: To set the display to increment every 24 hours an EDI supplied keypad, send the following sequence of keys. <A 0 1 2 4 0 0 0 0 0 0 D> To set the display to increment every 5 minutes and 30 seconds from an EDI supplied keypad, send the following sequence of keys. <A 0 1 0 0 0 5 3 0 0 0 D> 3 - Size/Increment Message: The program that controls this display is capable of driving a display that is from one digit to sixteen digits long. Before the display can operate properly, it must know how many digits are in the display. This information was entered at the factory and is stored in non-volatile memory. The same message that specifies the length of the display also specifies how much to change the display by each time that the time interval expires (see 2 Time Interval Message on previous page). This increment value can be from one to as large a number as the display has digits. The protocol for a size/increment message is as follows: <STX> <2-digit address> <2-digit display size> <1-digit to 16-digit increment value> <LF> (from 5 to 8 characters total) NOTE: While a leading zero is required in the address field, and is required in the display size field, leading zeros are not required in the increment value field. Examples: To cause a four digit display to increment by 10 for each time interval from a TELNET or other terminal window, press the following sequence of keys: <CONTROL B><01><0410><CONTROL J>

Examples: To cause a six digit display to increment by 1 for each time interval from a TELNET or other terminal window, press the following sequence of keys: <CONTROL B><01><061><CONTROL J> KEYPAD EXAMPLES: To cause a nine digit display to increment by 1 for each time interval from an EDI supplied keypad, send the following sequence of keys. <A 0 1 0 9 1 B> To cause a nine digit display to increment by 5 for each time interval from an EDI supplied keypad, send the following sequence of keys. <A 0 1 0 9 5 B> Service: There are no parts in your unit classified as user serviceable parts. The plastic or glass cover can be cleaned using a soft cloth and a gentle glass cleaning solution. Warranty: The standard warranty for all products is one year on all parts and labor at our facilities. All products are designed and manufactured by Electronic Displays Inc. If you need assistance, please call or FAX us and we will be happy to provide technical assistance. If you feel that your unit needs repair, please call us first and then ship the unit to: Electronic Displays Inc. 135 South Church Street Unit A Addison, Ill. 60101 Attn: Repair department Our telephone number is: (630) 628-0658 Our FAX number is: (630) 628-0936 PROUDLY MADE IN THE U.S.A.