NOW A PRODUCT! 1 /4 DIN PROCESS CONTROLLER. Single Loop Profile Controller (optional) NEMA 4X Front Panel PowerTune. The Interface Solution Experts

Similar documents
1/4 DIN PROCESS CONTROLLER

NOW A PRODUCT! 1/4 DIN Auto/Manual Station. The Interface Solution Experts. The Interface Solution Experts. PS532 V6 March 2017

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

MODCELL 2050R Single Loop Controllers

Eclipse Combustion Universal Digital Controller

UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

/8 DIN Motorized Valve Controller

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

Universal power supply

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

UDC1200 & UDC1700 Universal Digital Controllers Series Micro-Pro Specifications

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

Universal Process Controller

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

/8 DIN Universal Process Indicator

Temperature/Process Controllers Manual

SX90 Process Controller

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

STA SIL 2 and SIL 3 Capable Programmable Current/Voltage and RTD/Thermocouple Safety Trip Alarms

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

DPR 100 A/B Analog Scales

Trident and Trident X2 Digital Process and Temperature Panel Meter

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

LAUREL ELECTRONICS, INC.

Wall-/Pipe Mounted Universal Process Indicator

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

TCS. Description. Features. IECEx. Temperature Concentrator System Multi-Channel Transmitter

Digital Indicator Solutions

HIT/HIX HART Isolator

ControlMaster CM10, CM30 and CM50 Universal process controllers, 1 /8, 1 /4 and 1 /2 DIN

Zenex-ultra Ultra Precision (0.01 C) Self-Tune PID Temperature Controller with Programmable Timer

100mm Process Indicator Recorder

Omni + User Manual. Dual Setpoint Temperature Controller with Programmable Input & TIMER. Omni 96+ Omni 72+ Omni 48+ TMR TMR TMR

C160 Wall-/Pipe Mounted Universal Process Indicator

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

The CAL range of temperature controllers

ControlMaster CM10, CM30 and CM50 Universal process controllers, 1 /8, 1 /4 and 1 /2 DIN

PD765 TRIDENT. Trident Series Process & Temperature Meters.

CHLORINATION/DECHLORINATION CONTROLLER USER'S MANUAL

dual-line 6-dIGIt process MeteR

PXR Series Advanced Self-Tuning Temperature and Process Controllers

FICHA TÉCNICA DE PRODUTO

Omni. User Manual. Economic Self-Tune PID Temperature Controller. Omni 96. Omni 72 72X72. Omni ~ 265 V AC SUPPLY

OLS VT10 SERIES STANDARD DUAL DISPLAY PID AUTOTUNE RAMP-TO-SETPOINT ULC, UL, CE (4810) AUTO / MANUAL 15 SECURITY OPTIONS UNIVERSAL INPUT

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

PD765 TRIDENT. Trident Series Process & Temperature Meters.

LED indicators for normal/fault operating conditions, setup mode, loss of analog signal, and solid-state motor control output.

Temperature, Process &

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

DIGITAL INDICATING CONTROLLER

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

1 2 F C MAN 1 2 ALM DI RSP OUT FUNCTION SET UP. Figure 1 - UDC3000 Versa-Pro Controller

Temperature Measurement

SINGLE-CHANNEL PROCESS INDICATOR series 8001

ProVU 4 Advanced Temperature & Process Controller

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Integrated Multi-Function

SIY. New. Features! Features. PC-Programmable Signal Isolator/Converter

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

UDC2500 Universal Digital Controller. Specification. Overview. Features. Analog Inputs January 2009 Page 1 of 14

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

When these are combined with the Accutune III tuning with fuzzy logic overshoot suppression, the result is price/performance leadership.

DUAL-LINE TEMPERATURE METER

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

UDC 3500 FEATURES AND BENEFITS

HIGH-VOLTAGE DC METER

F 1559 % ALM RSP OUT SP Features

P/N /02 Rev. C ECO # Model 1440 Microprocessor-based Temperature Controller Installation and Operation Manual

Control IT. /16 DIN Controller/Alarm Unit. Data Sheet SS/C50_7 C50. C50 the 1 /16 DIN controller to suit your simplest applications

Simplified information where and how you want it.

PLC PL User Manual

PRO-EC44 Single or two loop advanced controller with graphic display

High Voltage DC Meter

Inform IT Single Pen Circular Chart Recorder

353 RetroPAK Controllers

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

EZ-ZONE PM PANEL MOUNT CONTROLLER

Environmental Chamber Programmer/Controller

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

Isolated Process Current Input with Loop Power 7B35

Tempco Instruction Manual

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

i8 Series from $240 1/8 DIN Temperature/Process & PID Controllers

500 SERIES. Hardware Installation and Modification Manual. Process Controllers. for Electronic Products Series 531, 532, 535, 545, 555 Model 2

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

Contents. Temperature & Process Measurement Indicators Setup Guide

Strip Chart Recorders Specification Sheet

JUMO Quantum PID100/PID200/PID300

PD7000. PROVU Dual-Line 6-Digit Temperature Meter SERIES.

MLC 9000 Bus Compatible PID

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

PID with. Controllers W A T L O W CPC400 SERIES. Multi-Loop

Transcription:

NOW A 5 3 5 The Interface Solution Experts PRODUCT! 5 3 5 1 /4 DIN PROCESS CONTROLLER Single Loop Profile Controller (optional) NEMA 4X Front Panel PowerTune The Interface Solution Experts www.miinet.com PS535 V8 March 2017

DESCRIPTION The 535 is a 1/4 DIN single loop process controller (SLC) designed to control any analog process variable (temperature, pressure, flow, level, etc.) in batch and continuous processes. The 535 s outstanding feature mix enables it to bring processes under control faster, more accurately and easily than competitive SLC s, PLC, and PC based control systems. PowerTune Adaptive Tune modifies PID parameters to eliminate oscillation or drift when load changes occur. Adaptive tune works automatically without disturbing the process. PowerTune Functions PowerTune Powerback reduces or eliminates SP overshoot at power up or after setpoint changes. PowerTune Pretune gets process up and running quickly and accurately. Optimal pretune performance is achieved by selecting a pretune algorithm appropriate for your process. The 535 is widely considered to be a best-in-class instrument due to three fundamental strengths. PowerTune Pretune automatically sets: 1) Initial PID parameters 2) Adaptive Tuning parameters 3) Powerback parameters Rugged Construction NEMA 4x front panel Thick damage resistant keys EMI/RFI resistance Input/output isolation Operator Interface 3 line vaccum flourescent display English prompts/messages Key color state indication Tuning and Control Algorithms Powertune - Adaptive tuning Powertune - Pretuning Powertune - Powerback anti overshoot 8 stored PID sets Multiple output algorithms Pretune Powerback Normal Opertion Four Field changeable output module locations (ma, Relay, SSR, DC, Logic, Loop Power) Two Universal (U, ma, RTD, T/C) PV inputs Load Chage Adaptive Tune Option board I/O RSP 5 contact inputs Actuator Slideware Expanded information about these strengths is detailed throughout this brochure. Optional RS 485 Communications Module Socketed PROM 10 year lithium battery for memory retention Page 2 PS535 V8

FEATURE ILLUSTRATION Compression gasket for reliable NEMA 4X Seal Extra large dedicated PV indication is viewable from a distance in all light conditions Extra large mounting lip to compensate for off size panel cutouts Optically correct, high contrast/low glare filter provides crisp reading even in sunlight Recessed location for engineering unit label Two nine character alpha numeric displays indicates prompts in English Recessed location for loop tag information Backlit keypad provides view ability in dark areas Red under key LED provides clear state indication (A/M, RSP) from a distance PS535 V8 Custom built vacuum florescent display with two full alpha-numeric lines and dedicated x-large PV readout Thick silicone rubber keys provide excellent feel and damage resistance Page 3

TOP (as viewed from back of controller) CONTACT INPUTS LINE 90-250Vac OPTIONAL ACTUATOR 24Vac or dc SLIDEWARE NEUTRAL FEEDBACK X OUT 1 OUTPUT 1 OUT 1+ OUT 2 X OUTPUT 2 OUT 2+ OUT 3 OUTPUT 3 OUT 3+ 1 2 3 4 5 6 10 11 12 13 14 7 15 + 8 16 EARTH DIN 9 17 GND S/W 1 S/W 2 S/W 3 RSP } RSP+ OUT } 4 OUT 4 + - GND DIN 1 DIN 2 DIN 3 DIN 4 DIN 5 COLD JUNC COLD JUNC+ 18 19 20 21 22 23 25 26 27 28 29 30 31 24 32 } } not used COMM RS 485 COMM+ PV2 UNIVERSAL PV INPUT 2 PV2+ } RTD 3RD PV1 UNIVERSAL PV INPUT 1 PV1+ OUTPUT 4 REMOTE SET POINT INPUT Input Functions PV Input (Universal) RSP Input (Optional) Contact Inputs (Optional) PV1 PV2 Switch on demand Range Activate RSP PV1 PV2 Switch on PV1 failure Bias Trip to Manual PV1 - PV2 Gain Lock in Manual mode PV1 + PV2 Local SP Tracking Select Alternate SP (1-8) Average of PV1, PV2 Select Alternate PID (1-8) High Select Low Select Acknowledge Alarm Inhibit Integral Control Invert Control Action Inhibit Adaptive Tuning Emulate Front panel Keys Digital Input for Data Acquisition Output Functions Outputs are plug-in modules. Types include: Analog (ma), Mechanical Relay, Solid State Relay, DC Logic, and Loop Power. Output 1 Output 2 Output 3 Output 4 Control Second Control Alarm Alarm Alarm Retransmission Retransmission Retransmission RS 485 Driver RS 485 Driver RS 485 Driver Loop Power Loop Power Page 4 PS535 V8

INPUT FUNCTIONS PROCESS VARIABLE Two universal inputs are available. Any input type may be field selected via jumper. Dual inputs may be used to: Select input on demand Switch upon failure Derive a PV by subtracting (PV1 - PV2) Derive a PV by adding (PV1 + PV2) Derive a PV by averaging (PV1 + PV2)/2 Select highest PV Select lowest PV THERMOCOUPLES RANGE F RANGE C B 104 to 3301 40 to 1816 E 454 to 1832 270 to 1000 J 346 to 1832 210 to 1000 K 418 to 2500 250 to 1371 N 328 to 2372 200 to 1300 R 32 to 3182 0 to 1750 S 32 to 3182 0 to 1750 T 328 to 752 200 to 400 W 32 to 4172 0 to 2300 W5 32 to 4172 0 to 2300 Platinel II 148 to 2550 100 to 1399 RTDs RANGE F RANGE C 100ohm Pt.(DIN) 328 to 1562 200 to 850 328.0 to 545.0 200.0 to 285.0 100ohm Pt.(JIS) 328 to 1202 200 to 650 328.0 to 545.0 200.0 to 285.0 100ohm Pt.(SAMA) 328 to 1202 200 to 650 328.0 to 545.0 200.0 to 285.0 Transmitter Signals Input Range Milliamps DC 4 to 20 0 to 20 Voltage DC 1 to 5 0 to 5 Millivolts DC 0 to 10 0 to 30 0 to 60 0 to 100 25 to 25 ACCURACY TYPICAL MAXIMUM LINEAR(Voltage) ± 0.025% of full scale ± 0.100% of full scale (Current) ± 0.050% of full scale ± 0.150% of full scale RTD 1 ± 0.050% of span ± 0.150% of span 0.1 ± 0.095% of span ± 0.225% of span THERMOCOUPLE J, K, N, E (> 0 C) ± 0.060% of span ± 0.150% of span J, K, N, E (< 0 C) ± 0.150% of span ± 0.375% of span T (> 0 C) ± 0.100% of span ± 0.250% of span T (< 0 C) ± 0.250% of span ± 0.625% of span R, S (> 500 C) ± 0.150% of span ± 0.375% of span R, S (< 500 C) ± 0.375% of span ± 0.925% of span B (> 500 C) ± 0.150% of span ± 0.375% of span B (< 500 C) ± 0.500% of span ± 1.000% of span W, W5 & Platinel II ± 0.125% of span ± 0.325% of span Display accuracy is ± 1 digit. These accuracy specifications are at reference conditions (25 C) and only apply for NIST ranges. Detailed accuracy information is available upon request. LINEARIZATION Thermocouple and RTD inputs are automatically linearized. Transmitter inputs may be linearized with a square root function or user-defineable 15-point straight line linearization function. INPUT IMPEDANCE Current Input: 250ohms Thermocouples: 10Mohms Voltage Input: 1Mohm RTDs: 10Mohms UPDATE RATE Input is sampled and output updated 10 times per second. Display is updated five times per second. TRANSMITTER LOOP POWER Isolated 24Vdc (nominal) loop power supply is available if a loop power module is installed in an output socket not used for control. Capacity is 25mA. INPUT SIGNAL FAILURE PROTECTION When input is lost, output is commanded to a predetermined output ( 5 to 105%). Thermocouple burnout is selectable for upscale or downscale. INPUT FILTER Single pole lowpass digital filter with selectable time constant from 0 to 120 seconds. CALIBRATION Comes fully calibrated from the factory and continuously calibrates itself for component aging due to temperature and time, except for the reference voltage. Field calibration can be easily performed in the field with a precision multimeter and thermocouple simulator. Process variable offset and gain factors are provided to correct for sensor errors. SETPOINT SELECTION A remote setpoint input is available. Signal is 0 20/4 20mAdc or 0 5/1 5Vdc (jumper selectable). Signal may be ratioed and biased. Eight local setpoints may be stored in memory. Setpoint selection is made via SET PT key or digital contact(s). DIGITAL INPUTS A set of five external dry contacts or open collector transistor driven inputs are available. Each can be configured to perform one of the following functions: Select remote setpoint Select either direct or reverse Select manual control control action Select second local setpoint Addressable through serial Select a second set of PID values communications only Acknowledge alarms Inhibit the reset term Simulate DISPLAY, FAST, and Lock controller in manual MENU keys mode Disable adaptive tuning In addition, if the set of five digital inputs is installed, four may be designated to select one of eight local setpoints (and associated PID set, if desired ) via a binary coded decimal (BCD) input. PS535 V8 Page 5

OUTPUT FUNCTIONS OUTPUT MODULES The controller can have a total of four control outputs, alarm outputs and/or loop power modules installed. There are five types of output modules which can be configured to suit your particular application. The modules may be ordered factoryinstalled, or they may be installed in the field. Analog module: Either 0-20mA or 4-20mA (front panel selectable) into a load up to 1000ohms. Accuracy ±15 microamps@25 C. Mechanical relay module: SPDT electromechanical relay. Resistive load rated at 5 amps at 120/240Vac. Normally open or normally closed selection is made by jumper. Output 4 is rated at 0.5 amps at 24Vac and is always normally open. Solid state relay (triac) module: Resistive load rated at 1 amp at 120/240Vac. Output 4 is rated at 0.5 amps at 24Vac. These outputs are normally open. DC logic (SSR drive) module: On voltage is 17Vdc (nominal). OFF voltage is less than 0.5Vdc. (Current limited to 40mA.) Loop power supply module: Current is limited to 25mA@24V. Control Outputs Up to two output modules may be designated for control. Any combination of output modules, with the exception of the loop power supply module, may be used. Duplex control is available if output modules are installed in the first and second output sockets. Position proportioning control with feedback is available if mechanical or solid state relay modules are installed in the first two output sockets, and the slidewire feedback option is installed. Slidewire feedback range is 0 to 1050ohms. "Velocity position proportioning control is available by installing mechanical or solid state relay modules in the first two output sockets. A special time based algorithm controls an electric actuator without the slideware feedback signal. Staged (split range) outputs are available if analog modules are installed in the first and second output sockets. This algorithm will allow the output range to be split between the two outputs. CONTROL ALGORITHM PID, P with manual reset, PI, PD with manual reset, and On-Off are selectable from the front panel. Duplex outputs each use the same algorithm, except On-Off may be used with PID. The PID algorithm used is non-interacting. TUNING PARAMETERS Proportional Band: 0.1 to 999% of input range Integral: 1 to 9999 seconds/repeat Derivative: 0 to 600 seconds Manual Reset/Load Line: 0 to 100% output Cycle Time: 0.3 to 120 seconds On-Off Deadband: up to 15% of input range (in eng. units) Up to eight sets of PID values may be stored in memory and selected automatically, based on setpoint value, process variable value, or the corresponding local setpoint (SP1 SP8) Retransmission Output Based on available outputs (any socket not used for control), up to two different variables can be simultaneously programmed for retransmission. Each precise, 16-bit resolution output may be scaled for any range. Variable selection includes: PV, SP, RAMP, SP, and OUTPUT. Transmitter Loop Power Isolated 24Vdc (nominal) loop power supply is available if a loop power module is installed in an output socket not used for control. Capacity is 25mA. Two or four wire transmitters can be powered. ALARMS The 535 controller has two software alarms. High and low alarms may be sourced to: Process Variable High Process Variable Low Process Variable High & Low Deviation from S.P. Band around S.P. Rate of Change Manual Control Module Remote S.P. Control Output If an alarm is tripped, the alarm message will show, the ACK key will illuminate (if acknowledgeable) and the ALM icon will light. If the alarm is tied to the first available non-control output, the 1 below the ALM icon will light. Similarly, if the alarm is tied to the second non-control output, the 2 below the ALM will light. The availabilty of outputs determines how many alarms can be tied to relays. Up to two alarm outputs are available if an associated mechanical, solid state relay or DC logic module is installed in any output socket not used for control. Global Alarm feature allows one or more of the internal software alarms to be tied to the same single, physical output. The acknowledge key is active for alarms associated with either loop. Page 6 PS535 V8

PROFILE CONTROL OPTION The 535 Profile Controller s unique operator interface makes it simple to set up and operate while retaining powerful profile functions detailed below. The 535 can store 20 recipes, with a sample shown below. Recipes are selectable via front panel, contact inputs, or serial communications. Recipes may be linked to create extra-long recipes. Set Point Time 200 180 160 140 120 100 80 60 40 20 Segment Event 1 Event 2 Guaranteed soak function insures soak set point has been achieved before soak segment starts Changes in ramp or soak segment possible while profile is running. Segment can be skipped while running. Ramps and soaks can be time or rate based Time base can be hrs:min or min:sec Recipes may be linked or repeated 99 times :20 :40 1:00 1:20 1:40 2:00 2:20 2:40 3:00 3:20 3:40 4:00 Ramp 1 Soak 1 Ramp 2 Ramp 3 Soak 3 Ramp 4 on Events can be used in ramp or soak segments Maximum 12 ramps and 12 soaks per recipe Last segment event can stay energized after profile is completed Event 3 on on PID Set 1 2 2 2 2 3 Ramping SP can automatically select alternate PID sets Up to three relay type events to outputs are available for equipment sequencing Power Restoration Modes: 1) RESUME recipe where it left off 2) HOLD at last SP prior to power loss 3) ABORT recipe 4) RESTART recipe Outputs 2-4 Event outputs SP retransmission to slave controller Alarm output Second Control output Line Power Out 1 Out 2 Out 3 Special Profile I/O Out 4 } Contact Inputs: Start Recipe Hold Recipe Reset Recipe Skip to next segment Abort Recipe Recipe 1-7 selection RS 485: All profile configuration and operation are accessible through serial communication PS535 V8 Page 7

GENERAL SPECIFICATIONS CONTROLLER ARCHITECTURE The 535 Controller hardware can be configured as follows: Inputs: Two univeral process variable inputs are standard. Available options include: remote setpoint, slidewire feedback and 5 digital inputs. Outputs: Four outputs are available. See Ordering Information. RS-485 Communications: Available as option with any configuration. SERIAL COMMUNICATIONS Isolated serial communications is available using an RS-485 interface. Baud rates of up to 19,600 are selectable. The protocol supports CRC data checking. If communications are lost, a time-out feature will command the controller to a particular control mode and specific setpoint or output if desired. Outputs 2-4 and digital inputs can act as host-controlled I/O independent of the controller s function. The PV may be sourced via this interface. May be installed in the field. DIGITAL DISPLAYS Upper display: five-digit, seven-segment. Used exclusively for displaying the process variable value. Height is 15mm (0.6 in.). 2nd display: nine-character, 14-segment alphanumeric. Used for displaying setpoint, deviation, output value, slidewire position (actual valve position) and configuration information. Height is 6mm (0.25 in.). 3rd display: nine-character, 14-segment alphanumeric. Used for indicating which loop is displayed and for displaying alarm messages and configuration information. Height is 6mm (0.25 in.). All displays are vacuum fluorescent. Color is blue-green. STATUS INDICATORS There are two types of indicators: icons and illuminated keys. ALM 1 and ALM 2 icons: alarm 1 and alarm 2 status. OUT 1 and OUT 2 icons: control output 1 and control output 2 status. MAN key illuminated: controller is in manual control mode. ACK key illuminated: alarm may be acknowledged. SET PT key illuminated: setpoint other than primary local setpoint is active. MENU key illuminated: controller is in configuration mode. MOUNTING Panel-mounted. WIRING CONNECTIONS 29 screw terminals in the rear of the instrument. WEIGHT Approximately 1 kg (2.2 lbs.). AMBIENT TEMPERATURE Operative Limits: 0 to 50 C (32 to 122 F). Storage Limits: 40 to 70 C ( 40 to 158 F). RELATIVE HUMIDITY 10 to 90%, non-condensing. VOLTAGE AND FREQUENCY Universal power supply: 90 to 250Vac, 48 to 62Hz. 24V (AC or DC power optional). NOISE IMMUNITY Common mode rejection (process input): >120 db. Normal mode rejection (process input): >80 db. AC line is double filtered and transient protected. Snubbers are provided for each relay output. ISOLATION Inputs and outputs are grouped into the following blocks: Block 1: process variable Block 2: outputs 1, 2, and 4 Block 3: communications, set of five digital inputs, output 3 (Earth Ground) Block 4: remote setpoint Each block is electrically isolated from the other blocks to withstand a HIPOT potential of 500Vac for 1 minute or 600Vac for 1 second, with the exception of blocks 1 and 4, which are isolated to withstand a HIPOT potential of 50 volts peak for 1 minute between each other. Inputs and outputs are not isolated from other inputs and outputs within the same block. CONSTRUCTION Case: flame resistant ABS Chassis assembly: plug-in type. Keys: silicone rubber with diffusion printed graphics. NEMA rating: front panel conforms to NEMA 4X when instrument is properly installed. AGENCY APPROVALS LISTED Process Control Equipment (Heavy Industrial) 4N66 (Available as an option) MEMORY RETENTION Lithium battery maintains all programming for approximately ten years. POWER CONSUMPTION 15VA at 120Vac, 60Hz (typical). Page 8 PS535 V8

SECURITY There are two levels of access: restricted and full. A configurable code is used to enter the full access level. Functions not available in the restricted level are configurable. Six different groups of parameters can be restricted. PROFILE CONTROLLER OPTION When a 535 is specified as a profile controller, the SET PT (setpoint key) is replaced at the factory with a RUN key to facilitate operation. Setpoint access is available through use of the DISPLAY key. All functions are described in the manual supplement. The 535 with profile option, provides full ramp and soak capability with the following features: 20 RECIPES/PROGRAMS Up to 20 recipes/programs may be stored in memory and recalled by number through the front panel keys, digital inputs or RS-485 Communications. 24 SEGMENTS PER RECIPE 12 ramps and 12 dwells may be programmed for each recipe. Programming a dwell time of OFF effectively skips the dwell allowing 2 consecutive ramps of different rates. Recipes may be linked if more than 24 segments are necessary. GUARANTEED SOAK WITH ADJUSTABLE HYSTERESIS When activated, dwell time doesn t start until the ramp setpoint has been achieved within the specified hysteresis (a positive or negative deviation from the dwell setpoint). 3 EVENT OUTPUT CAPABILITY Up to 3 event outputs, programmable per segment, may be selected depending on the availability of controller outputs. The 535 has 4 outputs. If 1 is used for control, 3 are available for events. Likewise, if 1 is for control and 1 for an alarm, 2 are available for events. These outputs are available to turn on fans, start another process and perform other functions. RAMPS PROGRAM IN TIME OR RATE A ramp can be programmed to take place over a specific amount of time or be based on the rate of change of the PV per hour. If time based, the time to reach setpoint must be between 0:01 and 99:59 (hours:minutes). If rate based, the setpoint must be reached at a rate between 9999 and 9999 engineering units per hour. DUAL TIME BASE Two modes are available, Hours:Minutes or Minutes:Seconds MULTIPLE CYCLES, 1 99 PER EACH RECIPE Recipes may be programmed to automatically repeat up to 99 times. RECIPE LINKING All 20 recipes may be linked to form a new longer version. For example, select recipe 4 to automatically follow recipe 2. REMOTE FUNCTIONS VIA DIGITAL INPUT Using the optional digital inputs, the following functions may be remotely activated: Start, Hold, Reset, Abort and Segment advance. MODIFY RECIPES WHILE RUNNING Individual recipes may be modified by the operator while running. REMOTE RECIPE CHOICE VIA DIGITAL INPUT Using the optional digital inputs, recipes 1-7 may be selected remotely. POWER RESTORATION MODES Four different power restoration modes are available. Upon power failure and subsequent return, the controller can either: 1) Resume a recipe where it left off 2) Return to the last output of the recipe and hold it 3) Abort the recipe 4) Start a new recipe automatically. TIE PID SETS TO RECIPES OR SEGMENTS Any one of eight PID sets may be tied to each recipe or segment to optimize control. MASTER/SLAVE CAPABILITY The 535 with profile controller option can retransmit the ramping setpoint to up to four 535s with remote setpoint creating a master/ slave relationship. With this capability, 5 loops, each running the same recipe, can be controlled. SEGMENT ADVANCE The operator may advance through the program segments while a recipe is running. MOUNTING AND DIMENSIONS PS535 V8 Page 9

Order Output 1: Control Code None 0 Mechanical Relay (5 amp) 1 Analog (milliamp) 2 Solid State Relay (triac) (1 amp) 3 DC Logic (SSR drive) 4 Output 2: Control, Alarm, or Retransmission None 0 Mechanical Relay (5 amp) 1 Analog (milliamp) 2 Solid State Relay (triac) (1 amp) 3 DC Logic (SSR drive) 4 Output 3: Control, Alarm, Retransmission, or Loop Power None 0 Mechanical Relay (5 amp) 1 Analog (milliamp) 2 Solid State Relay (triac) (1 amp) 3 DC Logic (SSR drive) 4 Loop Power 5 Output 4: Alarm, Retransmission, or Loop Power None 0 Mechanical Relay (0.5 amp, 24V) 1 Analog (milliamp) 2 Solid State Relay (triac) (0.5 amp, 24V) 3 DC Logic (SSR drive) 4 Loop Power 5 Options Enter 0 if not desired Slidewire Feedback for Position Proportioning Output A 24 (AC or DC) Operation F Slidewire and 24 (AC or DC) )Operation G Remote Setpoint Profile Controller Option Remote Setpoint and Profile Set of Five Digital Inputs D Certification H Five Digital Inputs and Certification J 535 0 0 B C E Serial Communications Enter 0 if not desired RS-485 Serial Communications S Note 1: Capability for position proportioning output is specified by ordering 535-11xxAxxx00, 535-33xxAxxx00, or 535-44xxAxxx00. Note 2: Capability for velocity proportioning output is specified by ordering 535-11xxxxxx00, 535-33xxxxxx00, or 535-44xxxxxx00. Note 3: Up to two outputs may be used for alarms. Note 4: All outputs are interchangeable modules. Note 5: The mechanical relay and solid state relay modules are derated to 0.5 amp at 24Vac when used as the fourth output. The Interface Solution Experts www.miinet.com United States info@miinet.com Tel: (818) 894-7111 FAX: (818) 891-2816 Australia sales@mooreind.com.au Tel: (02) 8536-7200 FAX: (02) 9525-7296 Belgium info@mooreind.be Tel: 03/448.10.18 FAX: 03/440.17.97 The Netherlands sales@mooreind.nl Tel: (0)344-617971 FAX: (0)344-615920 China sales@mooreind.sh.cn Tel: 86-21-62481120 FAX: 86-21-62490635 United Kingdom sales@mooreind.com Tel: 01293 514488 FAX: 01293 536852 Specifications and information subject to change without notice. Printed in U.S.A.