digital reading micropipettes

Similar documents
Sapphire pipettes. Your Power for Liquid Handling.

Operating instructions Models 926, 936 and 956. Acura electro. your electronic choice

Thermo Scientific Finnpipette Novus Single and Multichannels

VIAFLO Fixed and Adjustable Spacing Electronic Pipettes

XLS+ Pipettes. Trust Your Data Extraordinary Tools for Exceptional Results

Sapphire Pipettes. Your Power for Liquid Handling.

ErgoOne Pipettes: Overview

VIAFLO 96 VIAFLO 384. Microplate Pipetting Easy and Affordable

VIAFLO 96 VIAFLO 384 Microplate Pipetting Easy and Affordable

VIAFLO 96 VIAFLO 384. Microplate Pipetting Easy and Affordable

Sartorius Biohit Picus Electronic Pipettes

VIAFLO 96 VIAFLO 384 Microplate Pipetting Easy and Affordable

The Peak of Pipetting

Automated Liquid Handling. Smart Benchtop System for Your Lab GeneTheatre

Automated Liquid Handling. Smart Benchtop System for Your Lab GeneTheatre

Liquid Handling Systems MICROPIPETTES

Simple, intuitive, and compact. Liquid Handling Station

Disposable Glassware CO R N I N G A N D P Y R E X D I S P O S A B L E G L A S SWA R E D I G I TA L ST I R R I N G H OT P L AT E S...

Product Overview. your solutions

VWR HOMOGENIZERS. Precision and reliability. Benchtop and Handheld Homogenizers. Effectively and efficiently homogenize your sample

Tecan Cavro components overview. Tecan Cavro innovation is everywhere

Product Overview. Tecan Cavro Components Tecan Cavro innovation is everywhere

Universal Fit. Pipette Tips.

Tecan Cavro components overview TECAN CAVRO INNOVATION IS EVERYWHERE

Thermo Scientific Matrix Hybrid Pipette User Manual

T H E TITRE CRYOVIAL FAMILY THE C RYO V I A L FA M I LY C RYOVIAL. Reaching the highest levels of quality

Preliminary Lab Exercise Part 1 Calibration of Eppendorf Pipette

solarus HiClass Titration.

Part Number Product Description LAB M.N.

Sample Storage STORAGE BOXES & RACKS

Picus & Picus NxT Electronic Pipette User Manual

A 2 O Advanced Automated Osmometer

eprep Sample Preparation Workstation

Access. for Acoustic Sample Management. Acoustic Sample Management BROCHURE TRANSFORMING SAMPLE MANAGEMENT WITH ACOUSTIC LIQUID HANDLING

Mini Vortex Mixers Heavy-Duty Vortex Mixers Microplate Vortex Mixers Multi-Tube Vortex Mixers. Vortex Mixers

BioPette E Single and 8-channel Electronic Pipettes Operation Manual Version: 2.7

A 2 O Advanced Automated Osmometer

A 2 O Advanced Automated Osmometer

fluidhandling 96 and 384 channel liquid handling Reagent dispensing Non-contact acoustic dispensing Accessories and consumables

VWR HOMOGENIZERS. Benchtop and Handheld Homogenizers. Effectively and efficiently homogenize your sample. Precision and reliability

FULLY AUTOMATED 2 MICROPLATE ANALYZER

other sizes available on request

HandyStep electronic Repetitive Pipette

Rotor-stator Homogenizers

MINISCAN INSTRUCTIONS

SymBiot I Sample Workstation

Eclipse Earth Friendly Pipette Tip Refill

Now with the new CryoCube F740 series. Store More. The Eppendorf ULT Freezer Racking System

Plastic Consumables and General Laboratory Equipment

CryoClear. Cryogenic Vials. Innovation. for the long-term storage of your precious samples.

LX.5 (SFOC 1.25) High packing density. High performance. High reliability. High safety. High flexibility

Reagent Transfer User Guide

Dell keyboards, mice and more

A world of cryogenic equipment STORAGE BOXES INVENTORY RACKINGS CRYOVIALS ACCESSORIES

Technical Data. Items supplied: Transferpette S, adjustable volume, conformity certified, performance certificate, shelf/rack mount and silicone oil.

Magnetic Immunoassay Reader Operator Manual

The Homogenizer Company


The Homogenizer Company 2015 CATALOG

*T310-10A, 10ml vial has a polyethylene cap.

Laboratory Line. Multipurpose Laboratory Equipment. > For all kinds of laboratories > Robust and versatile > Equipment in HUMAN quality

Reconstitution Application Guide

TOP SELLING MODEL. Classic swivel USB drive with silver clip. Available in 5 colors: white, orange (021), blue (286C), black and red (185C).

B

Features Sealed Construction for Automatic Soldering. Contact form. Operating Force SPST- NO SPST- NO SPST- NO SPST- NO SPST- NO SPST- NO SPST- NO

Vial block. Power switch

Gilson Pipetman Starter Kits

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

Cryogenic Storage Systems

Customer Responsibilities

SPECS

PRESTIGE ASCEND CONSOLES PRESTIGE

Transferpette S. Pipettes & Tips. The Transferpette S the performance standard in pipetting

14. Chromatography Syringes/Microlitre Syringes

Operating Manual. Midi Plus Electronic Pipetting Controller

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

PRODUCT FEATURES AND HIGHLIGHTS

HEINE Veterinary ENT diagnostic instruments

Introduction to Humanscale Products

Bruker BioSpin FLOW NMR. Racks & Accessories Catalog. Version. NMR Spectroscopy. think forward

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system

Catalog 2015/2016. THINK! Development and production of customized products. Liquid handling products. Labware for general lab applications

Advancing Cancer Diagnostics Improving Lives. Leica RM2235. The Manual Rotary Microtome For Outstanding Durability, Precision, and Comfort

Interactive furniture DESIGNED FOR

Total Flexibility. Proven Quality.

User s Guide. connected

Facemask. Multi-Adjustable. Discover The Ideal Choice to Achieve Maximum Class III Compliance HEADGEAR PRODUCTS. Exclusive Patient Comfort Design

MAGNIFIERS & TASK LAMPS FOR INDUSTRY

SOLUTIONS RECERTIFICATION CALIBRATION AND UV/VIS REFERENCE MATERIALS. Photometric and Wavelength Accuracy Reference Material Set

QUICKStart Guide APT Versions 3.0 through 3.3

PRESTIGE SIGHT-LINE CONSOLES PRESTIGE. Sight line

Thermo Scientific GENESYS UV-Vis Spectrophotometer Accessories. Make the most of every sample

Sterilization Trays Containers Stringers

MAKE THE CHANGE FOR BETTER NEONATAL SCREENING. Introducing the new AutoDELFIA immunoassay system for newborn screening

CLAMPS & SUPPORTS CATALOG

ipod Docking Kit MOBILE ELECTRONICS Easily connects to your vehicles vent louvers for a quick and easy mounting solution.

Cavro robotics overview EXCELLENCE IN THE WORLD OF OEM COMPONENTS

HEINE Veterinary ENT diagnostic instruments

ELECTRONIC CATALOGUE CUSTOMER S AMENDMENTS ISSUE 1 January 2011 Page 1 of 9 pages

QX Series Cordless Torque Multiplier

Transcription:

Acura manual your expectations our tradition digital reading micropipettes The Acura manual pipette line is crafted with the same attention to detail that has been the hallmark of this line since its inception. Introducing a streamline design with an easy to read volume window, it also features a number of innovations making high-performance pipetting safe and easy. The Acura line features: Digital display window for permanent volume visibility User-friendly design Lightweight Ultra-soft, effortless activation Innovative tip ejection Swift-set user calibration system Entirely autoclavable at 121 C/250 F The Acura manual models 815 825 835 fixed micro macro 855 multi

Acura manual your expectations our tradition Engineered ergonomics and design The greatest challenge for our engineers was integrating new high-tech materials with an already proven ergonomic design. The resulting pipette is an instrument that offers comfort, durability and superior performance. Most comfortable pipetting Ergonomic shape, lightweight feel, and ultra-soft plunger travel are key elements of the new Acura family. 815 fixed 825 micro Smart and reliable volume adjustment State-of-the-art micrometric volume settings are achieved smoothly and precisely by turning the push button. Finely machined click-stops and a free rotating cap prevent any unwanted volume alterations from occurring. Digital display offers superior visibility Located on the front of the instrument, the display window allows the volume settings to be visible at all times during the pipetting process. Acura 815 1 µl to 10 ml Fixed volume unlimited The air displacement fixed volume pipettes come with all of the great features today's scientist expects from their pipettes. These include a slim ergonomic design, ultra-soft plunger stroke, autoclavability, and much more. The models are available in ultra-micro volumes (1, 5, and 10µL), micro volumes (20-1000µL), and macro volumes (2, 2.5, 5 and 10 ml). 0.1 2 µl 0.5 10 µl 1 10 µl 2 20 µl 5 50 µl Performance 2 Tip ejection easier than ever Ergonomically positioned, the large surface, soft-padded ejector button provides easy tip disposal. JusTip System In addition to easy tip ejection, the shaft height adjustment system called Justip, allows the user to utilize a wide selection of different brands of tips by adjusting the height shaft. Volume Inaccuracy Imprecision µl (E%) (CV%) 1 < +/- 2.0 % < 1.0 % 5 < +/- 1.4 % < 1.0 % 10 < +/- 0.7 % < 0.7 % 10Y < +/- 0.7 % < 0.8 % 15 < +/- 0.7 % < 0.5 % 20 < +/- 0.7 % < 0.5 % 25 < +/- 0.7 % < 0.6 % 30 < +/- 0.7 % < 0.6 % 40 < +/- 0.7 % < 0.5 % 50 < +/- 0.7 % < 0.4 % 60 < +/- 0.7 % < 0.5 % 70 < +/- 0.7 % < 0.4 % 75 < +/- 0.7 % < 0.4 % 80 < +/- 0.7 % < 0.35 % 90 < +/- 0.7 % < 0.3 % 100 < +/- 0.7 % < 0.3 % 120 < +/- 0.7 % < 0.4 % 150 < +/- 0.7 % < 0.3 % 200 < +/- 0.7 % < 0.3 % Volume Inaccuracy Imprecision µl (E%) (CV%) 250 < +/- 0.7 % < 0.4 % 300 < +/- 0.7 % < 0.4 % 400 < +/- 0.7 % < 0.3 % 500 < +/- 0.7 % < 0.3 % 600 < +/- 0.7 % < 0.3 % 700 < +/- 0.7 % < 0.2 % 750 < +/- 0.7 % < 0.2 % 800 < +/- 0.7 % < 0.2 % 900 < +/- 0.7 % < 0.2 % 1000 < +/- 0.6 % < 0.2 % Volume Inaccuracy Imprecision 6 ml (E%) (CV%) 2 < +/- 0.8 % < 0.5 % 2.5 < +/- 0.8 % < 0.5 % 5 < +/- 0.7 % < 0.4 % 10 < +/- 0.5 % < 0.2 % Workstation 337 Stable, sturdy universal pipette workstation can accommodate 7 single-channel micropipettes. Available in five attractive colors: grey, blue, yellow, green & rose.

Acura 825/835 Adjustable volume micro and macropipettes Equipped with a precision digital display, the new line is continuously adjustable down to very precise volume resolutions. Single-handed volume setting is easy if the other hand is not free. Measuring unknown volumes by aspiration is also possible with a high degree of accuracy. Click-stops, together with a freely rotating smartie-plunger button cap ensure the stability of settings while pipetting. A total of 8 micropipettes ranging from 0.1 to 1000 µl; and 2 macropipettes, 0.5-5 ml and 1-10 ml models, are available. 835 macro Swift-set calibration The swift-set user calibration system - with integrated key and locking mechanism - makes tedious calibration procedures a thing of the past. Simple yet precise, this adjustment procedure is in full compliance with international standards and recommendations. 10 100 µl 20 200 µl 100 1000 µl 0.5 5 ml 1 10 ml Easy to change color coding The Acura pipettes have a colorcoded display window and a removable smarties button cap. Need more than one color or multiple cap colors for lab or department identification? Choose from 14 colors, or pick the smartie mix which contains all of these available colors. Macropipettes maxi advantages The 835 models can accommodate nozzle filters for added protection against liquid fill and contamination. Workstation 340 Convenient workstation holds 3 Calibra or Acura, multior single-channel pipettes. Performance Volume Inaccuracy (E%) Imprecision (CV%) range Min. vol. Min. vol. Min. vol. Min. vol. Micropipettes 0.1-2 µl < +/- 6.0 %* < +/- 2.0 % < 5.0 %* < 1.5 % 0.5-10 µl < +/- 2.5 %** < +/- 1.0 % < 1.8 %** < 0.5 % 1-10 µl *** < +/- 2.5 % < +/- 1.0 % < 2.5 % < 0.7 % 2-20 µl < +/- 2.5 % < +/- 1.0 % < 1.7 % < 0.5 % 5-50 µl < +/- 1.5 % < +/- 1.0 % < 1.0 % < 0.5 % 10-100 µl < +/- 1.5 % < +/- 0.8 % < 1.0 % < 0.2 % 20-200 µl < +/- 1.5 % < +/- 0.8 % < 0.6 % < 0.2 % 100-1000 µl < +/- 1.5 % < +/- 0.5 % < 0.5 % < 0.2 % Macropipettes 0.5-5 ml < +/- 1.5 %* < +/- 0.6 % < 0.6 % < 0.4 % 1-10 ml < +/- 0.8 %** < +/- 0.5 % < 0.4 % < 0.2 % * At 0.5 µl. Indicative data at 0.2 µl: E <+/- 12 %, CV < 8 % ** At 1.0 µl. Indicative data at 0.5 µl: E <+/- 5 %, CV < 3 % Optional adapter-nozzle allows for the use of Pasteur pipettes on 5 ml model, in addition to Polypropylene tips (Accessories sold separately). Minimum maintenance/sterilization Shock, heat, chemical, and UV light resistance is provided by carefully selected materials and superior construction techniques. Consequently, maintenance requirements are virtually non-existent. Thorough cleaning and sterilization can be achieved by autoclaving the instrument fully assembled (121 C, 20 minutes). 3

Pipette Tips Tips without filter Cat. No. Size Color Sterile Autoclavable Packaging Case Microtips with Flat Tip for Gel Sequencing (*0.2mm, **0.4mm) 851176 *0.1-10 µl Natural 2 rack/cs, 100/rack 200 851178 **0.1-10 µl Natural 4 rack/cs, 200/rack 800 Microtips (*Short, **Long) 851172 *0.5-10 µl Natural Yes 10 rack/cs, 100/rack 1000 851174 **0.1-10 µl Natural 4 rack/cs, 200/rack 800 Microtips W851239-01 1-10 µl Natural 10 rack/cs, 96/rack 960 W851239-02 1-10 µl Natural Sterile 10 rack/cs, 96/rack 960 W851239-03 1-10 µl Natural Bulk 1000 851246 1-200 µl Natural Yes 10 rack/cs, 96/rack, 960 851247 1-200 µl Natural Sterile Yes 10 rack/cs, 96/rack 960 851248 1-200 µl Natural Yes Bulk 1000 851271 2-200 µl Yellow Yes Bulk 1000 851272 2-200 µl Yellow Yes 10 rack/cs, 96/rack 960 851276 100-1000 µl Blue Yes Bulk 1000 851277 100-1000 µl Blue Yes 10 rack/cs, 96/rack 960 Macrotips 851355 0.2-2 ml Natural Yes Bulk 250 851357* 1-5 ml Natural Yes Bulk 250 W851362** 1-5 ml Natural Yes Bulk 500 W851363** 1-5 ml Natural Yes 2 rack/cs, 50/rack 100 851358 2-10 ml Natural Yes Bulk 100 Pasteur Pipettes & Adapter for Macropipettes 357331 146 mm Glass Yes 5 pack/cs, 200/pack 1000 357335 228 mm Glass Yes 5 pack/cs, 200/pack 1000 W820023 Adapter PVDF 1/case 1 Protection Filters for Macropipettes W851341 2 ml Cellulose Bulk 250 W851342 5 ml Cellulose Bulk 100 851346 10 ml PP Fibers Bulk 250 Tips with filter Cat. No. Size Color Sterile Autoclavable Packaging Case Microtips with Flat Tip for Gel Sequencing (0.2mm, 0.4mm) 851179-01 0-100 µl Natural Sterile Individually Wrapped 1000 851179-02 0-100 µl Natural 10 rack/cs, 96/rack 960 851181-01 0-300 µl Natural Bulk 1000 851181-02 0-300 µl Natural 10 rack/cs, 96/rack 960 851181-03 0-300 µl Natural Sterile Individually Wrapped 1000 851181-04 0-300 µl Natural Sterile 10 rack/cs, 96/rack 960 851180-01 0-1000 µl Natural Sterile Individually Wrapped 1000 851180-02 0-1000 µl Natural 10 rack/cs, 96/rack 960 4

Acura 855 Multichannel micropipettes The comprehensive Acura manual line offers 8- and 12-channel models with volumes ranging from 0.5 to 350 µl. These multi-channel instruments extend pipetting possibilities to high-throughput microplates while maintaining the same features as the single-channel Acura pipettes. 855 multi Optimal working position In addition to ergonomic design, the multi-channel volumetric modules can be rotated to select the best working position. 0.5 10 µl 5 50 µl 20-200 µl 40 350 µl Adjustable tip ejector Position of tip ejector can be adjusted in seconds with a 4 mm span to perfectly match to tips used. The specially designed shape of ejector head adds to the effortless sequential tip ejection process. Performance Volume Inaccuracy (E%) Imprecision (CV%) range Min. vol. Min.vol. Min. vol. Min.vol. 0.5-10 µl < +/- 3.5 %* < +/- 1.5 % < 3.0 % < 1.0 % 5.0-50 µl < +/- 1.0 % < +/- 0.8 % < 1.0 % < 0.4 % 20-200 µl < +/- 0.9 % < +/- 0.7 % < 0.6 % < 0.3 % 40-350 µl < +/- 1.0 % < +/- 0.8 % < 0.6 % < 0.3 % All purpose reservoirs Ideal for multi-channel pipettes, the reagent reservoirs come in various shapes and configurations. Workstation 340 Convenient workstation for 3 Calibra or Acura, multior single-channel pipettes. 5

Acura manual your expectations our tradition Acura 825 adjustable volume micropipettes & Acura 835 adjustable volume macropipettes Cat. No. Volume Division Tip style case 825 micropipettes W810300 0.1-2 ul 0.002 ul 10 ul 1 W810302 0.5-10 ul 0.01 ul 10 ul 1 W810304 1.0-10 ul 0.01 ul 200 ul 1 W810306 2.0-20 ul 0.02 ul 200 ul 1 W810308 5.0-50 ul 0.1 ul 200 ul 1 W810310 10.0-100 ul 0.1 ul 200 ul 1 W810312 20.0-200 ul 0.2 ul 200 ul 1 W810314 100.0-1000 ul 1.0 ul 1000 ul 1 835 macropipettes W810316 0.5-5 ml 0.01 ml 5 ml 1 W810318 1.0-10 ml 0.01 ml 10 ml 1 Acura 855 multichannel micropipettes Cat. No. Volume Division Tip style case 8-channel W810600 0.5-10 ul 0.01 ul 10 ul 1 W810602 5.0-50 ul 0.1 ul 200 ul 1 W810603 20.0-200 ul 0.2 ul 200 ul 1 W810604 40.0-350 ul 0.4 ul 350 ul 1 12-channel W810606 0.5-10 ul 0.01 ul 10 ul 1 W810608 5.0-50 ul 0.1 ul 200 ul 1 W810609 20.0-200 ul 0.2 ul 200 ul 1 W810610 40.0-350 ul 0.4 ul 350 ul 1 Accessories Cat. No. Description case Smartie Plunger Caps W820000 White Smarties 6 W820001 Grey Smarties 6 W820002 Vanilla Smarties 6 W820003 Lemon Smarties 6 W820004 Yellow Smarties 6 W820005 Orange Smarties 6 W820006 Red Smarties 6 W820007 Rose Smarties 6 W820008 Pink Smarties 6 W820009 Purple Smarties 6 W820010 Ice Blue Smarties 6 W820011 Blue Smarties 6 W820012 Mint Smarties 6 W820013 Green Smarties 6 W820014 Assorted color Smarties 14 Your local distributor Acura 815 fixed volume micropipettes & Acura 835 fixed volume macropipettes ordering information Cat. No. Volume Tip style case 815 micropipettes W810000 1 ml 10 ul 1 W810002 5 ml 10 ul 1 W810004 10 ml 10 ul 1 W810006 15 ml 200 ul 1 W810008 20 ml 200 ul 1 W810008 25 ml 200 ul 1 W810010 30 ml 200 ul 1 W810012 40 ml 200 ul 1 W810014 50 ml 200 ul 1 W810016 60 ml 200 ul 1 W810018 70 ml 200 ul 1 W810020 75 ml 200 ul 1 W810022 80 ml 200 ul 1 W810024 90 ml 200 ul 1 W810026 100 ml 200 ul 1 W810028 120 ml 200 ul 1 W810030 150 ml 200 ul 1 W810032 200 ml 200 ul 1 W810034 250 ml 1000 ul 1 W810036 300 ml 1000 ul 1 W810038 400 ml 1000 ul 1 W810040 500 ml 1000 ul 1 W810042 600 ml 1000 ul 1 W810044 700 ml 1000 ul 1 W810046 750 ml 1000 ul 1 W810048 800 ml 1000 ul 1 W810050 900 ml 1000 ul 1 W810052 1000 ml 1000 ul 1 835 macropipettes W810056 2.0 ml 5 ml 1 W810058 2.5 ml 5 ml 1 W810060 5.0 ml 5 ml 1 W810062 10.0 ml 10 ml 1 Accessories Cat. No. Description case Work Station Model 340 - fits 3-multi or single-channel W851369 Work Station 1 Universal Work Station Model 337-7-single channel pipettes W851361 Light Grey 1 W851354 Ice Blue 1 W851356 Vanilla Yellow 1 W851359 Mint Green 1 W851360 Rose 1 Pasteur Pipette Adaptor Nozzle W820023 5 ml Acura 835 1 Reservoirs W851364 V-Shape, PP, 70 ml 20 W851365 V-Shape, PP, 140 ml 20 W851239 8 channel, 40 ml 10 W851368 12 channel, 40 ml 10 Warranty 3 year limited warranty. See package insert for complete warranty terms and operational instructions. Acura and Calibra are registered trademarks of Socorex ISBA. JusTip is a trademark of Socorex ISBA. 6 1501 North 10th Street, Millville, NJ 08332-2038 1.800.225.1437 1.856.825.1100 www.wheatonsci.com WSP Lit No. 7736 0407